HomeMy WebLinkAboutEngineering Letter 11 1 _ ' 11111 00� Y Donald J. Nuelle P.E. Date: 8/09/17 11634 SW Rowena Street Port St. Lucie, FI 34987 JWN Builders, LLC 1701 SE Carvalho Street Port St. Lucie, FL 34983 Attn: James Newman RE: Regan Lot 387, Nettles Blvd. Permit# 1'705'0084 Dear Mr. Newman, I have reviewed your request to investigate the omission of the masonry "ladder" reinforcement called for on the plans. Given the fact that this is a (4) course high wall with a 16" bond beam and the whole wall being poured solid with no cavity caps, I can approve the construction of this segment of the masonry wall with no horizontal mortar reinforcement. Please insure the remainder of the structure is constructed with the horizontal reinforcement as called for on the plans. This lower 4 course section of the structure is approved without the "ladder" horizontal masonry reinforcement. If you or any other affected party have any questions or require additional information, please contact me at (561)-629-6975. r , 1 e � r� r 76 ti Don J elle`P,IE 52046° � r 1 1