Donald J. Nuelle P.E. Date: 8/09/17
11634 SW Rowena Street
Port St. Lucie, FI 34987
JWN Builders, LLC
1701 SE Carvalho Street
Port St. Lucie, FL 34983
Attn: James Newman
RE: Regan Lot 387, Nettles Blvd.
Permit# 1'705'0084
Dear Mr. Newman,
I have reviewed your request to investigate the omission of the masonry
"ladder" reinforcement called for on the plans. Given the fact that this is a (4)
course high wall with a 16" bond beam and the whole wall being poured solid
with no cavity caps, I can approve the construction of this segment of the
masonry wall with no horizontal mortar reinforcement. Please insure the
remainder of the structure is constructed with the horizontal reinforcement as
called for on the plans.
This lower 4 course section of the structure is approved without the
"ladder" horizontal masonry reinforcement.
If you or any other affected party have any questions or require additional
information, please contact me at (561)-629-6975.