HomeMy WebLinkAboutInsulation Cert Mar 06 18, 12:OOa JWN Builders LLC, 28719500 PA
t
INSULATION INSTALLATION CERTIFICATE
JWN Builders,LLC
TO: LDT BLOCK: SECTION:
10B#: 111179 JOB NAME:
JOB ADDRESS: 387 Nettles Blvd
ky The undersigned hereby c4rtlfaes that.insulation has been installed atthe above described property as M41"
follows
1. Exterior CBS walls have been insulated with............................Check one ( }Spray on cellulose
to a thickness of N/A inches,which thickness,according to the ( )Fiberglass blankets
manufacturer, CFI ( )Aluminum Foil
i Density N1A will yield an"R"value of 9 QO Block Fil
Exterior Frame walls have been insulated with............................Check one ( )Spray on cellulose
to a thickness of 625 inches,which thickness,according to the ()0 Fiberglass blankets
manufacturer, Certainteed (
_ ... _ )Alminurn F0d
-- Density W A Willyielda"Rvalue of )Other
_
---... ..
19 ( )Other spray Foam
2. Main Ceilings have been insulated with......................-.Check one ( )Fiberglass blankets
to a thickness of 5 5 inches,which thickness;according to the ( )FibergIass loose fill
manufacturer, SES Sucraseal ( )Aluminum Foil
Density N/A will yield an"R"value of 21 Q()Spray Foam
Ceifnga Cathedral have been insulated with.......................Check one ( )Fiberglass blankets
to a thickness of inches,which thickness,according to the ( )Fiberglass loose 1611
manufacturer, { )Aluminum Foil
Density N/A. will yield an"R"value of ( )Other celua-
3. Interior knee walls have been insulated with.................................Check one ( )Fiberglass blankets
to a thickness of5.5 inches,which thickness,according to the ( }Polyurethane
manufacturer, SES Sucraseal ( )Spray on cellulose
Density NIA will yield an`,R"value of 21 (X)Other Spray Foam
4. Garage partition walls of conditioned living areas have been
insulated with........... :.- . ,... ., . . ............................:Check one p()Fiberglass blankets
to a thickness of 3.5 inches,which thickness,according to the ( )Spray on cellulose
manufacturer, Cerlainteed ( )Polyurethane
Density NIA will yield an`W value of 13 ( )Met Aluminum Foil
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating
different tenants shall be insulated as follows-Frame/Metal stud walls R-1 I(Min.);CBS or Concrete walls
R-3(Min.);by Energy Code requirements. See Energy Code Rev.1/87,paragraph 903.2(b),.on page 9-17,
latest edition. These"minimums levels of insulation"are not included in the Energy Calculations,butshall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed-on site insulation shall be the P-C.F.
(Ib/113)average of three(3)"DRY SAMPLES"of actual installatio
MER Enterprises LLC � ,\ �
Insulation Contractor Insulation Contractor Signature
MCIN6231 12/19/17
Insulation Contractors CC# Date of Certification
IZU
Builder's Name-Builder's CC# N P c
m �„t14th r a
tir�T�s� KELLYLYOUNG
7REVED -,'4, d Notary public Slate of Florida
Cm ^jy Cc-tnm.Exp!r'-s Jul 1.2018
6 2018Commission-Ff 13810'
ST. tyt pLFi1116€If1g