Loading...
HomeMy WebLinkAboutPermit Worksheets PERMIT WORKSHL11- 1 I page•i or PERMIT NUMBER ® R[qEA`'-D New Home Used Home �4g O 9 Installer THOMAS GRUNDEL License# IH1025148 1017 Home installed to the Manufacturer's Installation Manual 19 Address of home 860 NETTLES BLVD Home is installed in accordance with Rule 15-C being installed Single wide Wind Zone 11 Wind Zone Ill Manufacturer JACOBSEN Length xwidth 20X37/38 Double wide ® Installation Decal# TBD NOTE: if home is a single wide fill out one half of the blocking plan Triple/Quad Serial# if home is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home(new or used) PIER SPACING TABLE FOR USED HOMES where the sidewall ties exceed 5 ft 4 in. Installer's initials TG Load Footer bearing size 16"x 16" 18 1/2"x 18 20"x 20" 22"x 22" 24"X 24" 26"x 26" • Typical pier spacing (256) 1/2"(342) (400) (484)* (576)` (67G) lateral capacity (sq in) 2' 6' ps 4 Show locations of Longitudinal and Lateral Systems 1500 ps longitudinal (use dark lines to show these locations) ps 2500 ps 3000 ps ps * interpolated from Rule 15G1 pier spacing table. PIER PAD SIZES POPULAR PA®SIZES `R I-beam pier pad size 17X22.5 Pad Size Sq In x16 Perimeter pier pad size 16X16 16x18 Other pier pad sizes� 16 x22.5 (required bythe mfg.) x L.L.. 13 4 x264 Draw the approximate locations of marriag 20x2T400 wall openings 4 foot or greater. Use this x 4 marriage wall piers within 2'of end of home per Rule 15C i• symbol to show the piers. x25 1=F9fl8 24 x24 Listall marriage wall openings greater than 4 fool 26 x and their pier pad sizes below. ANCHORS Opening Pier pad size -r-r-r-r 1-'1-7-r-r-r- -7-r-r-r-1--1-I-T-r-r- Oft X 5ft I 1 1 1 1 1 I 1 1 1 1 1 1 I 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 -------- r—r—r+n'- rY—;—,—'I-7'r-1 1 1 1 i-7—;—r—t'—;—,— —7—r—;—1`—i'Y—;—q—,--r"1 1-5 17X22.5 —�_1_�_ I I I I 1 ul 1 --1-i 1 1 1 L_�__I-J_J1 1_L-L_l_J_J_1_L_L-I-J_I IL J_1_L_L_L_�_J_1 J-1_L_L-1L FRAMETIES 1 1 1 1 1 1 1 1 1 I 1 I 1 1 1 1 1 1 1 L_L_1_-I-J L_L_L_I_..1_..,-1-y_L_h-)--i_.1-;-L_1-_L-I_...,_.�_;-L_L-{-_I-J_J_;-i-L•-L_I. 1 1 1 ' ' ' ' 1 ' 1 ' 1 1 1 1 ' 1 ' 1 ' 1 within 2'of end of home X r-r'-�-�--1-•r�`-`t'-r-r�-�-r-r-r-r-1--1-�-7-*-r-�-t--1-i-7-*-r-r-1-'+-y-7-r-r-r-1 1 1 I 1 1 (IC I I 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 t 1 I 1 1 I I 1 1 spaced at 5'4"oc X 1 1 1 1 1 4.• 1 I 1 1 1 1 1 I 1 1 I � 1 1 I 1 I 1 � 1 I I- 1 I 1 1 I , 1 1 1 r-r-r-,--t-_�• r- 1--r-,-�-T-p-r-�-�;-;- ,-r-�-r-r i-;- ,-r-r-, -r-1- -7-^-,--r-1 J_J_1_!_L—!J_J_J_1_L_L_t!_!_J_1_L_!^�_J_!_!_S_L_L_1—_I_! TIEDOWNCOMPONENTS OTHER TIES 1 1 t -iI �1 1 f I I 1 1 1 1 I 1 1 1 1 I 1 1 1 1 1 I 1 1 1 1 1 1 1 1 Number L�.1_ 1-J_J_1_1 L_1_J-J..1_L_L_L_I_J_J_1_L_L_L-1_J-J_1_L_L_L.1_J_J_i_L_L_L� ' 1 t 1 Longitudinal Stabilizing Device(LSD) Sidewall 1--1--+--t—+—*—�-1---1--+—•+—y—�—r-1--1—�—ti—t—r—�—r-1--,—�—?—r-1--s..—r-1--1—;—r—r—r-1--1 Manufacturer OLIVER Longitudinal I I I I I I I I I I t t l l l l l l 1 1 1 1 1 1 1 1 1 I 1 1 1 I 1 Longitudinal Stabilizing Device w/Lateral Arms Marriage wall r-1._r_I_-,_'l_Y-�-^1--1--1�'1-'�-T-r-r-f—t-'l-'1-•/-r-r-I--r'l-l-'f-t-r�l-•-1--1-•1-7-r^r-1 ... 1 t 1 1 1 1 1 1 1 1 1 I 1 1 1 I 1 1 1 I 1 1 1 1 I 1 1 1 1 1 1 1 1 1 I 1 1 Manufacturer --. ... Shearwall r-r-r-1-v^T-r-r-r-r'Y-•7-7-T-r-r`I--1-1-7`r-r-r-rl-l-T-r-r-r-r�-�-T-r-r-r-1 PERMIT WORKSHEET I page c or z PERMIT NUMBER IN Site Preparation ' POCKET PENETROMETER TEST Debris and organic material removed YES The pocket penetrometer tests are rounded down to 1500 psf Water drainage: Natural Swale Pad X-Other or check here to declare 1000 lb.soil without testing. X X 15�j X 15QS Fastening multi wide units 15Q� Floor: Type Fastener. LAG Length: 6" Spacing: 24" Walls: Type Fastener: LAG Length: Spacing: 24" POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: GALV Length: Spacing: For used homes a min. 30 gauge, 8"wide,galvanized metal strip 1. Test the perimeter of the home at locations. will be centered over the peak of the roof and fastened with galv. roofing nails at 2"on center on both sides of the centerline. 2. Take the reading at the depth of the footer. Gasket(woathorproofing roquiromont) 3. Using 500 lb. increments,take the lowest reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip X 15(d X 15ki X 15Qd of tape will not serve as a gasket. Installer's initials TG TORQUE PROBE TEST Type gasket FOAM Installed: The results of the torque probe test is 285 inch pounds or check Pg. Between Floors Yes X here if you are declaring 5'anchors without testing .. Atest Between Walls Yes X showing 275 inch pounds or less will require 5 foot anchors. Bottom ofridgebeam Yes X Note: Astate approved lateral arm system is being used and 4 ft. anchors are allowed atthe sidewall locations. I understand 5 ft Weatherproofing anchors are required at all centerline be points where the torque test reading is 275 or less and where the mobile home manufacturer may The bottom board will be repaired and/or taped. Yes X Pg. requires anchors with 4000 lb holding capacity. Siding on units is installed to manufacturer's specifications. Yes X _ TG Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water. Yes X ALL TESTS MUST BE PERFORMED BY LICENSED INSTALLER Miscellaneous Installer Name THOMAS GRUNDEL Skirting to be installed. Yes X No Dryer vent installed outside of skirting. Yes X N/A Date Te.stee3 Range downflow vent installed outside of skirting. Yes X N/A �U Drain lines supported at4 foot intervals. Yes X Electrical crossovers protected. Yes X r 1 Other: J Li Electrical onnect electrical conductors between multi-wide units, but not to the main power ource. Thi�n�des the bonding wire between mult-wide units. Pg. _ Installer verifies all information given with this permit worksheet ��✓ Plumbing is acc r to and true ased on the onnect al I sewer drains to an e>asting sewer tap or septic tank. Pg. manufacturer's in ation instruc s and pr, ule 15C-1 &2 Installer Signature ' onnect all potable water supply piping to an e>asting water meter,water tap,or other Date rJnr+c�r+rlen4nieter cnnnly cic femc Pn 11 Page 1 Residential Heat Loan and Heat Gain Calculation 51512017 In accordance with ACCA Manual J Report prepared I ly; Central Air Systems Inc. For: Baungartner 880 Nettles Bivd Jensen Beach,fl Design Condrdo i Fort Pierce Indoor: Outdoor: Summer mperature: 70 Summer temperature: 90 Winter to perature: 70 Winter temperature: 42 Relative i irnidl1y: 55 Summer grains of molsture: 127 Daily temperature rangeMedium Building Campo r ent Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (STUN) Duct 1,703 0 1,703 611 Floors 683 0 583 1.048 Walls 2,348 0 2,348 2,786 Ceilings 2,149 0 2,149 1,368 People 1,500 1,150 2,650 0 Fireplaces 0 0 0 a . Misc 1,200 0 1,200 0 Windows 8,189 0 8,189 3,580 Doors 0 0 0 0 Glassdoors 0 0 0 .0 Skylights 0 0 0 0 Infiltration 1,056 2,187 3,243 3,430 Whole House 18,728 3,337 22,065 12,823 (2 tons) HVAC-Cale Rai i ential 4.0 by HVAC Computer Systems Ltd. f 1. Laud Cdudatbneam eatinretN OM1Iy,eetwl beds trmy tlsty due to weeihs erW oaMWCllon dMtareturoa {•' J PY ++'d SZ096E3'T 9S za��a i�n0 ti 7 WU :IT G T Oz Bo EEW V Et,*zT LT9Z16R/RR agATgnqN