Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
-0 TMOVE- . 0 TAG: All dimensions are in inches 1 o 0 > ♦ AIRFLOW � l HORIZ. RIGHT 21.00 1.06 .09 1 HEATER K.O. D IDISCHARGE OPENING TA048-SQ-217.00 4Ton Convertible Air Handler oA TWE048 P 130A/F \ \ File copy DOWNFLOW 4.65 6 -�1 5.75 AIRFLOW 1.06 TOP VIEW LOW VOLTAGE 5.75 HEATER AIRFLOW It r 72 �i 2.42 �2.56 212 r L 1.48 I J _1-I I 423 2.50 CIRCUIT BREAKER IT 0 - 12.00 G -® I � 2.00 GAS LINE SEE TABLE 1 � O O AIRFLOW ll i HORQ LEFT / \ / 6.30 LIQUID LINE 3/4-14 TAPERE PIPE THREAD A SEE TABLE !Al 2.81 / \ \ VLOW VOLTAGE \ \ / \ \ , 3.49 5.23 718 DIA. HOLE FOR Tr H ELECTRIC POWER SUPPLY 3.88 SIDE VIEW WHEN HEATERS ARE NOT USED FILTER ACCESS C' SUB BASE .61 �.61 -{[- 19.34 -1 {-,.DS VERTICAL UPFLOW RETURN E OPENING .61 1 BOTTOM VIEW FILTER LATCHES From Dwg. No. 21 D800261 Rev. 6 Flow GAS LIQUI Model No. A B C D E F G H J LINE LINE Control SIZE SIZE TWE048P130A 57.9 27.12 26 23.88 24.78 26.13 TXV 3.21 1.48 7.7 1 Braze Braze © American Standard Inc. 1993 GENERAL DATA • • MODEL TWE048P130A/F RATED VOLTS/PH/HZ. 208-230/1/60 RATINGS ) See O.D. Specifications INDOOR COIL — Type Plate Fin TM Rows —F.P.I. 4 - 14 Face Area (sq. ft.) 6.19 Tube Size (in.) 3/8 copper Refrigerant Control TXV NonBleed Drain Conn. Size (in.) © 3/4 NPT INDOOR FAN — Type Centrifugal Diameter -Width (In.) 10 x 10 No. Used 1 Drive - No. Speeds Direct - 3 CFM vs. in. w.g. O See Fan Performance No. Motors — H.P. 1-1/2 Motor Speed R.P.M. 1080 Volts/Ph/Hz 20.0-230/1 /60 F.L. Amps - L.R. Amps 3.1 - 6.6 . FILTER - Furnished? Yes Type Recommended Throwaway Lo. Vel. (No: Size-Thk.) 1 - 20 X 25 - 1 in. Hi Vel. (No.-Size-Thk.) REFRIGERANT (R-22) Ref. Line Connections Brazed Coupling or Conn. Size — in. Gas 1 1/8 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H X W X D Crated (in.) 53 1/2 x 28 1/2 x 23 1/2 WEIGHT Shipping (Lbs.) / Net (Lbs) 188 / 173 TABLE 1 TWE048P WIRING DATA (Unit and Heater With Single Point Power to Heater and Indoor Blower Motor) Capacity @ Minimum Circuit Stages Number Heater Contains Maximum Overload 240 V Rated Amp city or of Amps per Circuit Circuit protection Heater KW BTUH Voltage 208 240 Steps Circuits 208 240 Breakers 208 240 Model No. 4,8 16,400 208-240/1/60 26 29 1 1 17.3 20 No 30 30 BAY96X1405 5.76 19,600 208-240/1/60 30 34 1 1 20.8 24 No 30 35 BAY96X1406 7.68 26,200 208-240/1/60 39 .44 1 1 27.7 32 No 40 45 BAY96X1408,8F 9.6 32,800 208-240/1/60 48 54 1 1 34.7 40 No 50 60 BAY96X1410,10F 9.6 32,800 208-240/1/60 48 54 1 1 34.7 40 Yes 50 60 BAY96X1410A 10.56 36,100 208-230/1/60 52 60 1 1 38.1 44 No 60 60 BAY96X1411 10.56 36,100 208-240/1/60 52 60 1 1 38.1 44 Yes 60 60 BAY96X1411A 1536 52,400 208-240/1/60 48/26* 54/30* 2 2 34.7/20.8* 40/24* Yes 50/30* 60/30* BAY96X1415 19.20 65,500 208-240/1/60 48/43* 54/50* 2 2 34.7/34.7* 40/40* Yes 50/45* 60/50* BAY96X1419 21.12 72,100 208-240/1/60 48/52* 54/60* 2 2 34.7/41.6* 40/48* Yes 50/60* 60/60* BAY96X1421 25.92 88,500 208-240/1/60 48/52/22* 54/60/25* 3 3 34.7/41.6/17.3* 40/48/20* Yes 50/60/25* 60/60/25* BAY96X1426 10.56 36,100 208-240/3/60 34 38 1 1 24.2 28 No 35 40 BAY96X3411 15.36 52,400 208-240/3/60 45 52 1 1 36 41.6 No 45 60 BAY96X3415 NOTES: * Circuit 1/Circuit 2/Circuit 3 CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electric Codes. SPRESSURE DROP FOR ELECTRIC HEARS IN AIR HANDLER MODELS NUMBER OF RACKS 1 2 3 4 5 AIRFLOW CFM AIR PRESSURE DROP INCHES W.G. 600 0.01 0.02 0.02 700 0.01 0.02 0.02 800 0.02 0.03 0.03 0.04 900 0.03 0.03 0.04 0.05 1000 0.04 0.04 0.05 0.06 1100 0.04 0.05 0.06 0.07 0.08 1200 0.05 0.06 0.07 0.08 0.09 1300 0.06 0.07 0.08 0.09 '0.11 1400 0.07 0.08 0.10 0.11 0.13 1500 0.08 0.09 0.11 0.13 0.15 1600 0.09 0.10 0.12 0.15 0.17 1700 0.10 0.11 0.14 0.17 0.19 1800 0.11 0.13 0.16 0.19 0.21 1900 0.13 0.15 0.18 0.21 0.23 2000 0.14 0.17 0.20 0.23 0.26 AIR FLOW PERFORMANCE TWE048PI30AfF EXTERNAL STATIC PRESSURE (INCHES OF WATER) VERTICAL (See Notes) HORIZONTAL (See Notes) 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED LO HI MED LO HI MED LO HI MED LO r12.0 0.77 0.64 0.65 0.77 0.66 0.64 0.44 0.83 0.73 0.71 0.45 1300 0.85 0.65 0.51 0.82 0.51 0.16 0.72 0.58 0.53 0.00 1400 0.75 0.52 0.34 0.71 0.33 0.83 0.60 0.40 0.28 1500 0.65 0.38 0.10 0.60 0.00 0.74 0.46 0.00 0.71 1600 0.54 0.22 0.48 0.64 0.28 0.60 1700 0.43 0.00 0.36 0.54 0.02 0.48 1800 0.31 0.23 0.43 0.36 1900 0.19 0.08 0.21 0.23 2000 0.05 0.08 0.09 2100 HEATER RACKS HEATER NO.OF MODEL NO. RACKS BAY96X1405 1 BAY96X1406 2 BAY96X1408 2 BAY96X1410 2 BAY96X1411 3 BAY96X1415 3 BAY96X1419 4 BAY96X1421 4 BAY96X1426 5 BAY96X3411 3 BAY96X3415 3 NOTES: Vertical: With filter, no horizontal drip tray. Small apex baffle Subtract 0.06" W.G. for downflow. Horizontal: As shipped but without filter Subtract 0.05" W.G. for horizontal left From Dwg. No. 21A800383 Rev. 0 3 Mechanical Specifications FEATURES AND GENERAL INFORMATION —These blowercoil COIL — Aluminum fin surface is mechanically bonded to 3/8 inch units are completely factory assembled including coil, condensate OD copper tubing. Coils are factory pressure and leak tested. drain pan, fan, motor, filters and controls in an insulated casing that FAN — The blower housing is forward curved, dynamically bal- can be applied in horizontal or vertical configuration.The "F" model indicates a Florida model which requires 4.2 "R" value insulation. perm with a 3 speed direct drive fan motor. The fan motor is permanently lubricated. The TWE-P line of air handlers provides exclusive compact size combined with 6-way convertibility in sizes up to 5 ton. The unit ships in the right hand horizontal configuration and con- verts to vertical upflow just by standing the unit on end. No tools required. Simple coil rotation provides downflow and horizontal left applications. CASING — These models have a rugged galvanized sheet metal and steel frame construction. The casing is painted with an enamel finish. The casing is insulated and provides knockouts for electrical power and control wiring. REFRIGERANT CIRCUITS — The TWE-P units havea single refrigerant circuit. The TWE030P through TWE063P refrigerant circuit is controlled by a factory installed non -bleed thermal expan- sion valve (TXV). Since the Trane Company has a policy of continuous product improvement, it reserves the right to change spectfications and design without notice. Technical Literature - Printed in U.S.A. The Trane Company Unitary Products Group 6200 Troup Highway Tyler, TX 75707-9010 An American -Standard Company 4 CONTROLS— Low voltage terminal board, fan contactor, and plug in module for accessory electric heat control is included. TWE-C models also have a check valve. FILTERS — Standard size filters are included. The T VE030P through,TWE063P have standard size throwaway filters. ELECTRIC HEATERS — Heaters for the TWE-P air handlers are available in a wide range of capacities and voltages with various staging options, and plug-in control wiring. Heaters fit inside the internal compartment. Library Product Literature Product Section Unitary Product Split System Air Handler Model TWE048 — 4 Ton Literature Type Submittal Sequence 217.00 Date September 1993 File No. PL-UN-S/SP-TWE048-SQ-217.00 9/93 Supercedes New P.I.