Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's (2) y He C - - wrightsoft Project 'Summary Date: p�' Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772-466-6799 Fax 772-466-6796. Email:QUICKCALCS@AOL.COM Project Inf . • - • • For: THE GRAND CARLTON `W`Y�NNE DEVELOPMENT, FT. PIERCE,.FL Notes: Design • • Weather Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70: OF Inside db. 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 .Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh Method Simplified Latent Cooling Equipme.ntload Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent(0 cfm) 0 Btuh Heatingg . Cooling (none) Area e 1446. 1446 Equipment latent load 5521 Btuh Volume(ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary- Make . Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating.input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27. °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50: in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=32 OF Backup: Input=7 kW, Output=23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft` 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N - wrigntsoft° Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:.OUICKCALCS@,AOL.COM 1 Room name Entire House BEDROOM 2 Eposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A flocs =:0143 n: -4:00. 2,55 503 465 1862 1184 72 72- 288 183 :4A5 tom;. . 0 770 "n' 21;56 19.31 38 0'. 815 730. . 0 0. «0.. :,,.0 13AAocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1Aclom 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13AAocs 0.143 se 4.00, 2.55 34 34 136 86 0 0 0 0 13AAocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 t-G 1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A-4ocs 0143 w 4.00 2.55 310 237 949 603 104 72 288 183 1Ac1om 1,270 ::w. 35:56. 55.21 32 2 1140 1770 - 32 2 1140 1770 4A5:2om :;0:770 w 21:56 19:31 41: 41 :880: - 788`;: _0 - 0: 0._ 0 P 12C-0sw. 0.091 2.55 1.28 192 192 469 246 0 0 0 0 C , 16A0md -232 1446 : 1446 1295 3354`..:.: 297 297 266 689. F- 22A tpI 0.989 - - 27.69 0.00 1446 156 4325 0 297 49 1357 0. 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a), Infiltration . 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal(lines 6 to 13) 17848 17520 5053 4925 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 66M 7325 Air required(cfm) 1160 1160 328 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wr.ightsoft` 2017-Apr-11 06:29:38 Lek Right-Suite®Universal 201117.0.14 RSU08101 Page 1 ...uick CalcslDocuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N - -wrightsofts Right-M Worksheet Job: Entire House Date` QUICK CALLS, INC. By. 317 ST.LUCIE LN.,F.T.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS ,AOL.COM 1 Room name WIC KITCHEN 2 E)posed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ft2 172.0 ft2 Ty Construction LI-value Or HTM Area (ft2) Load Area (ftz) Load number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A�ocs ;0143 `n 4.00 `2.65 0. 0 0 :'. 0 O i 0 0 0. . 4A5 tom; O.T70 n' _ 21:56 19:31 _ 0 0 .: '. 0 0 0_ 0 0 ... p. 13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 -G IA-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 T---D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W , ': 13A-4ocs 0143 se 4.00 2.55 0 0 0. 0 0 0 0 . 0 13AAocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 t-G 1Aclom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A46cs .0143 w 4:00 2.55 0 0 0 .0 0 0 0 0 1A-clom: 1270 w : 35 56• 55.21 0 0 p. 0 0 p p p 4A52om::,:. A770 .w 21.56_. -19.31 0 0-. 0 p 0,.: 0 > '0 0 P. 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C ",16A30md:," 0 032.,-'-. 0p90 2,32` 54 54 48: 125 ' 172, _. 172 .,': .154 ;399 F 22A-tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 1171 317 311 12 a) Infiltration 0 6 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal pines 6 to 13) 48 117 317 2311 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49%1 100 1126 Total room load 64 174 418 3437 Air required(cfm) 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrigF�tsoft'. Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N 9 wrightsoft' Right-J®Worksheet Job: Entire House Date: By: v DICK CALCS Q , INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772.46M796 Email:QUICKCALCS@/\OL.COM 1 Room name BATH BEDROOM 2 2 E)q)osed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ftz Ty Construction U-value Or HTM Area (ft2) (ft') Load number (Btuh/ft2°F) (Btuhlft2) or perimeter (ft) (Btuh s) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y✓ 13A-0acs b' 143 n; 4:00 „2.55 40 40 160 102 128. 128 513 326 t--G "4A52om ". : 0770 n :. 2156 .`19.31. 0 0 . 0. 0` ::0' : 0... 0 :0. 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 1N . 13A4ocs 0143 se .4.00 2.551. 0 0 0 . 0 1 34 34 _ 136 86 W 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 I -G 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13AAocs .0 143 W. 4'00. .255 0 0 0 0 0 0 0 0 1Ac1am ,: 1 270 w-. 35.56 55.21 .0 0 0 0 0 .. 0 0 0 4A5 tom ,0 770 .w'. .21:56 _ :19:.31 0 0 0 - 0 0.- 0 0 p P 12C-0sw. 0.091 - 2.55 1.28- 0 0 0 0 0 0 0 0 C . ;;96.A-30md' ::.:. 0.032. ".0.90 `232 ,. •.•:45 45," .:.` -40. 104 7.204: 204 182 ::477 F 22A tpl 0.989 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED exursion -16 -85 Envelope loss/gain 339 196 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal Qines 6 to 13) 425 214 3571 3498 Less extemal load. 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 1 32% 49%1 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required(cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual.J 8th Ed. Qom. -IF[F wr.ightsoft 2017-Apr-11 09:29:38 .4C�A Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N ~ wrightsoft' Right�-J0 Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@\OL.COM 1 Room name LAUNDRY GREAT/DINING 2 Bq)osed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft= 526.0 ft2 Ty .Construction U-value. Or HTM Area number (Btuh/ftz°F (ft) Load Area (ft� Load (Btuh/ft Y) or perimeter (ft) (Btuh) or perimeter , (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grass N/P/S Heat Cool 6 13A flocs 0143 n` 400 2;55 0 0 0 0 ;;' 255 217 :869 552 . 4A5 tom:: 0.770 n 21:56 19:31 0 0 0 0 38' :.`0- 815. .. 730. 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W - 13A-4ocs 0.143 'se 4.00 Z65 0 0 0 0 0 0 0 0 V�! 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 -a 1Aclom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs. 0143 w 4.00 2.55 0 0 0 •0 206 165 661 420, 1A�1om 1-270 .w 35.56 65.21 0 0 - 0 0 %0 t) - 0 0 4A5 tom' :.0 770:„wW 21:56 . '19:31 " 0 0 :.' 0.: 0 . 41 4.1 680 788 P 12C-0sw 0.091. - 2.55 1.28. 56 56 143. 72 0 0 0 0 C. 16A.30fndi.;'. 0`032 0.90 '2.32 42 .. 42 38 97 526,` 526 r'4Z1 , 1220. F 22A-tpl. 0.989 - 27.69 0.06 42 6 1W 0 526 47 1302 0 6 c)AED excursion j� 668 Envelope loss/gain 539 270 4997 4379 12 a), Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 643 298 5994 5112 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 .Subtotal 643 298 5994 5112 1151 Duct loads 1 32% 49%1 204 145 32% 49% 1899 2490 Total room load 846 443 7892' 7602 Air required(cfm) 42 20 390 338 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrightsof - Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page A ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=M a J8 Front Door faces: N 9e 4 - 1-wrightsoft, Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. ay- 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 I Room name FOYER M.BAT{ 2 .Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/ 001 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2'F) (BtuIVft2) or perimeter (ft ) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0acs 0 143 n :4 00 :.',2 55 8 8.:. 32 ?0 0 p 0:, V.. 0 ,4A5 tom 0:770 n .. ._21 56 19.31 0_ . ... . :p 0 13A-4ocs 0.143 a 4.00 Z55 48 27 108 69 6 0 0 0 --G 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11130 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A46cs 0:148 se 4.00 2.55 0 0 0 0 0 0 0 . 0 V!1 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 60. 57 228 145 �-�G IA-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13AA00s 0143 w 4.00 2.65 0 0 0 ..0 0 0 0 0 1A-c16m 1.276 -w :35 56 55 21 0 - 0. - 0- 0 0 p 0: 0' 4A"r2om 0 to::w:- 21 56 .. ,_ 19 31.. 0 0.'. U 0 _ 0 0 P 12C-0sw 0.091 - 2.55. 128 72 72 183 92 0 0 0 0 C 16A=30md'.<. 0:032 0Ml . .1' 32 50: 50 . 45, 116 . 56 56 56 '.. .- 130 F. 27A-tPl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6. 6 c)AED excursion -89 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other p p Subtotal(lines 6 to 13) 913 529 885 . 516 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 1 Duct loads 321/6 49%1 289 258 320/6 491/6 280 251 Total room load 1202 787 1166 768 Air required(cfm) 59 35 58 34 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed ACCA weiyhtsoft- Right-Suite®Universal 2017 17.0,14 RSU08101 M17-Apr-11 09:29:38 ...nick CalcslDoeumentslTHE GRAND CARLTON-1446,rup Cato=MJ8 Front Door faces: N Page 5 wri htsoft Duct.System Summary Job: 9 Entire House Bate. y QUICK CALCS,INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:-772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@/\OL.COM Project Information For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT PIERCE, FL i, Heating. Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available.static pressure .0.50 :in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250%0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length.(TEL) 176 ft Supply Branch Detail Table Design gn Htg Clg Design . Dlam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl . Ln (ft) Ln (ft) Trunk BATH h .560 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM-A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.Ot OxO VIFx 23.3 115.0 st1 M.BAn+A h 768 58 34 0 0 Ox0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0. 135.0 st2 Supply , b - Trunk Htg. pig Design_ Veloc Diam H x W Duct . Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st-1 Peak AVF 1043 1691 0.285 1020 %0 0 x 0 VinlFlx Wri htsoft° 9 Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-1109:29:38Page 1 �'� ...uick Calcs\Documents\THE GRAND CARLTON4446.rup Calc=MJ8 Front Door faces: N e Return Branch Detail Table Grille Htg CIg TEL Design Veloc Diam. H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) . Opening (in) Mati Trunk rb1 OxO . 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft' 2017-Apr-1109:29:38 ^.. 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ACC ...uick Calcs\Documents\THE GRAND CARLTONA446.rup Calc=MJ8 Front Door faces: N