HomeMy WebLinkAboutEnergy CodeC.
F:LORoi A ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: REBECCA DRAWDY
Builder Name:
Permit Office:
Street:
City, State, Z.ST. LUCIE COUNTY, FL,
Permit Number:
Jurisdiction: ,
Owner:
Design Location: FL, Fort Pierce
1. New construction or ebsting New ( From Plans)
9. Wall Types (1674.0 sgft.)
a. Concrete Block - Ext Insul, Exterior
Insulation Area
R=4.0 1674.00 ftz
2. Single family or multiple family Single-family
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R=
4.. Number of B,edrogms 2
d. NIA
10. Ceiling Types (2509.01sgft.)
R=
Insulation Area
5. Is this a worst case? No
a. CathedrallSingle Assembly (Unvented) R=20.0 2509.00 ftz
6. Conditioned floor area above grade (ft2) 2509
b. NIA
c. NIA
R= ftz
R= ftz
Conditioned floor area below grade (ftz) 0
11. Ducts
R f 2
6 201
7. Windows(271.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
a. U-Factor. Sgl, U=0.55 271.00 ftz
SKGC: SHGC=0.50
12. Cooling systems
kBhAr Efficiency
b. U-Factor: N/A
a. Central Unit
39.0 SEER:16.00
SHGC:
c. U-Factor: WA
13. Heating systems
kBtuRir 'Efficiency
SHGC:
WA ft=
a. Electric Heat Pump
34.0 HSPF:7.70
d. U-Factor:
SHGC:
Area Weighted.Average.Overhang.Depth: 2.000 ft.
14. Hot water systems
Area Weighted Average SHGC: 0.500
a. Natural Gas Tankless
Cap: 1 gallons
8. Floor Types (2509.0 sgft.) Insulation Area
EF: 0.590
a. Slab -On -Grade Edge Insulation R=0.0 2509.00 ftz
b. Conservation features
b. N/A R= ftz
iP
None
None
R=
c. NIA
15. Credits
__ ___ .__.__._ .. _ -._ _-•-- _
_
Total Proposed Modified Loads: 29.76
PASS
Glass/Floor Area: 0.108 Total Standard Reference Loads: 43.68
I hereby certify that the plans and specifications covered by
Review of the plans and'
OoaE Srq?�
ti
this calculation are in compliance with the Florida Energy
s specifications covered by this
P
,, . -
Code
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
PREPAUD BY
this building will be inspected for
......._c
DATE:
compliance with Section' 553.908
1 hereby certify that this bog, as designed, is in compliance
il 'n
Florida Statutes.
rtiCO0 WE
with the Florida Ener de
BUILDING OFFICIAL:
OWNER/AGENT:
DATE:
DATE:
611I2015 9:01 PM Ener9YG g au e® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
2
Address Type:
Street Address
Title: REBECCA DRAWDY
Bedrooms:
2509
Lot #
Building Type: User
Conditioned Area:
1
Block/SubDivision:
Total Stories:
Owner:
Worst Case: No
PlatBook:
# of Units: 1
BuGder Name:
Rotate Angle: 0
Street:
County:
ST. LUCIE COUNTY
Permit Office:
Cross Ventilation:
City, State, Zip:
ST. LUCIE COUNTY,
Jurisdiction:
Whole House Fan:
FL,
Family Type: Single-family
New/E)dsting: New (From Plans)
Comment:
CLIMATE
/
V
Design Location
FL, Fort Pierce
IECC
TMY Site Zone
FL ST_LUCIE_CO_INTL 2
Design Temp
97.5 % 2.5 %
39 90
Int Design Temp Heating
Winter Summer Degree Days
70 75 722
Design Daily Temp
Moisture Range
62' Low
BLOCKS
Number
N
Name
Area Volume
-
1
Blockl
2509 22581
SPACES
Number
1
Name
Main
Area Volume Kitchen Occupants
2509 22581 Yes 2
Bedrooms
2
InfilID Finished
1 Yes
Cooled Heated
Yes Yes
FLOORS
# Floor Type Space Perimeter R Value
1 Slab -On -Grade Edge Insulatio Main 195 ft 0
Area
2509 fe
---
Tile Wood Carpet
0 0 1
ROOF
/
V
# Type
Roof
Materials Area
Gable Roof
Area Color
Solar I '
Absor.'
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1 Hip
Composition shingles 2718 ftx
I
0 tta Medium 0.96
No 0.9
No 20 22.6
ATTIC
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0
2509 ft=
N N
CEILING
Space
# Ceiling Type
1 Cathedral/Single Assembly (Unvented) Main
R-Value
20
Area
2509 ftz
Framing Frac
0.11
Truss Type
Wood
m"21LE F COPY
6/1/2015 9.01 PM EnergyGauge®USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 2 of 5
h
WALLS
r
Cavity Width Height
Sheathing
Framing Solar
Below
Adjacent S ace
PEt
In Area.
Maim-
Eractifin Ahnnr
Gradeu
1 N
Exterior Concrete Block - Ext Insul Main
4 54 g
486.0 ft2
0
0 0.75
0
2 E
Exterior Concrete Block - Ext Insul Main
4 40 9
360.0 fN
0
0 0.75
0
3 S
Exterior Concrete Block - Ext Insul Main
4 50 9
450.0 ft'
0
0 0 75
0
4 W
Exterior Concrete Block - Ext Insul . Main
4 42 9
378.0 iI2
0
0 0.75
0
DOORS
1
#
Ornt Door Type Space
Storms
U.-Value
Ft
Width
In
Height
Ft In
Area
1
S Insulated Main
None
.46 6
6 8
40 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Overhang
/
V #
Wall
Omt ID Frame Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1
N 1 Metal Single (Tinted) Yes
0.55 0.5
80.0 ft2 2 ft 0 in
6 It 0 in
Drapes/blinds
None
2
N 1 Metal Single (Tinted) Yes
0.55 0.5
20.0 ft2 2 ft 0 in
6 ft 0 in
Drapes/blinds
None
3
N 1 Metal Single (Tinted) Yes
0.55 0.5
15.0 fe 2 ft 0 in
7 ft 0 in
Drapeslblinds
None
4
E 2 Metal Single (Tinted) Yes
0.55 0.5
75.0 ft2 2 It 0 in
7 ft 0 in
Drapesiblinds
None
5
E 2 Metal Single (Tinted) Yes
0.55 0.5
9.0 IF 2 ft 0 in
7 It 0 in
Drapes/blinds
None
6
S 3 Metal Single (Tinted) Yes
0.55 0.5
72.0 ft2 2 ft 0 in
7 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Walll Height
Exposed Wall Insulation
1
462 ft2 462 It'
22 ft
9 it
11
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Best Guess .0005
3290.6 180.65 339.74 .365
8.7434
HEATING SYSTEM
#
System Type Subtype,
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump None
HSPF:7.7
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Air Flow
SHR Block
Ducts
1
Central Unit None
SEER:16
39 kBtu/hr 1170 cfm
0.75 1
sys#1
6/1/2015 9:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
HOT WATER SYSTEM
- System Type
SubType
Location EF Cap Use SetPnt
Conservation
Natural Gas
rl
Tankless
Garage 0.59 1 gal 60 gal 120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
C
System Model # Collector Model # Area
Volume
FEF
t # Company Name
ftz
None None
DUCTS
— SuPPiY —
— Return —
Air 1 CFM 25
Handler TOT
CFM25
OUT
QN
# Location R-Value Area
Location Area Leakage Type
1 Attic
6 201 fiz
Attic 20 ft� Default Leakage
Main (Default) (Default)
J�at
TEMPERATURES
pProgramableThermostat: N
Ceiling Fans:
Cooling [[ ]]Jan [[jFeb
Jan [X] Feb
L j Mar
Mar
r Ma X Jun [X] Jul
[ ] AP y 4 Jun [[ Jul
Apr May
[X] Aug [X] Sep
11 Aug Sep
Se
[ ] Oct
lLxjl Oct
Oct
L j Nov
[[xll Nov
X Nov
Dec
Dec
H Dec
Heating [X]
Feb
X Mar
X
11
Apr May Jun Jul
Lix11 [
[[ ]1
[[ Aug P
Venting [[ )1 Jan [[ ]j
Thermostat Schedule: HERS 2006 Reference
Hours
7 1 8
9
10
11
12
Schedule Type
1
2 3 4 5 6
Cooling (WD) AM
78
78 78 78 78 78
78 78 78 78 78
78 78
78 j 78
78
78
78
78
78
78
78
78
PM
Cooling (WEH) AM
78
78
78 78 78 78 78
78 78 78 78
78 78
78 78
78
78
78
78
78
78
78
78
PM
78
78
Heating(WD) AM
68
68 68 68 68 68
68 68 68 68
68 68
68 68
68
68
68
68
68
68
68
68
PM
68
68
Heating(WEH) PM
68
68 68 68 68 68
68 68
68
68
68
68
Y
61112015 9:01 PM
ErwgyGaugeo USA - RaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
,,FORM 405-19- Florida Code Compliance Checklist
+ Florida Department of Business and Professional Regulations
Rocirlantini Whnip Building Performance Method
ADDRESS: PERMIT #:
ST. LUCIE COUNTY, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Air leakage
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
and cooling system. Where forced -air furnace is primary system,
controls
programmable thermostat is required. Heat.pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation systems shall not exceed the minimum ASHRAE 62 level.
ventilation
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
swimming Pools
403.9
Pool. pumps and pool pump motors with a total horsepower (HP) of. = 1
HP shall have the capability of operating at two or more speeds. Spas
& Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Cooling/heating
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires 'separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
R-19 space permitting.
LCei±ling�s/kne�ewalls�405-�2*.I
6/112015 9:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
w `ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 68
The lower the EnergyPerformance Index, the more efficient the home.
ST. LUCIE COUNTY, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (W)
7. Windows"
Description
a. U-Factor:
Sgl, U-0.55
SHGC:
SHGC=0.50
b. U-Factor:
NIA
SHGC:
c. U-Factor:
NIA
SHGC:
d. U-Factor:
NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
Single-family
1
2
No
2509
Area
271.00 ft2
ft2
ft2
ft2
2.000 ft.
0.500
8. Floor Types Insulation Area
a. Slab -On -Grade Edge insulation R=0.0 2509.00 ft2
b. NIA R= ft2
c. WA R= ft2
9. Wall Types
Insulation
a. Concrete Block - Ext insul, Exterior
R=4.0
b. NIA
R=
c. NIA
R=
d. N/A
R=
10. Ceiling Types
Insulation
a. Cathedral/Single Assembly (Unvented) R=20.0
b. N/A
R=
c. WA
R=
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
1.2. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Natural Gas
I
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. j
Builder Signature: Date:
/FLp
Cit Zip:
Address of New Home: �8LP% S y
Area
1674.00 ft2
ft2
ft2
ft2
Area
2509.00 ft2
ft2
ft2
R ft2
6 201
kB.tulhr . Efficiency
39.0 SEER:16.00
kBtulhr Efficiency
34.0 HSPF:7.70
Cap: 1 gallons
EF: 0.59
None
tiO��HE STq��O
♦,),COD W6'�J�.4
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
`"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software