HomeMy WebLinkAboutSoil Nuclear GuageV
9
k
1A
V
a
if
Soil Nuclear Gauge
Report Date: 8/6/2015
Test Method: ASTM D 6938
Port, St. Lucie
FBPE CA # 4930
521 NW Enterprise. Drive
Port.. St. Lucie, FL 34986.
Phone: 772-9243575 Fax:712-924.3586
Client:
Project:
Rebecca Percy
13-0217.01
11298 Muller Road
11298 Muller Road
Fort Pierce, FL 34945
Fort Pierce, Florida
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
MIn1Max
Comp.
(%)
Remark
1
8%6/15
P-1
NIA
9.5
1.12.'0
10.1
107.4
12
- 96
951105
Pass
2
8/6/15
1 P-1
N/A
9.5
112.0
10.1
108.3
12
97
95 / T05
Pass
- Test Information
Test #
Test Location
Elevation
,Reference
Gauge
Make I Model I SN
Field Technician
1
Below Slab Grade: Addition, Foundation • Pad, East End
01- d
Teoxler T3430 22260
Thomas; Kenneth
2
Below t31ab.Grade: Addition,, Foundation Pad, WestEnd
0-1
TroxlerT3430 22260
Thomas, Kenneth'
Remarks
Comments
Related.Tests.
Pass: Tests results comply with specifications
Tests are "Direct Transmission"_(Mettrotl A)'unless probe depth is'noted as "Backscatter".
Gauge calibration data.on•file with the -testing agency.
i Test #
I Related Test #
Test Type
Test Reports shall not.be.reproduced, except in full, without the written approval of GFA International Inc.
Q v 04
edo
�r
_ onald"W Mo'Ier, RE. 4
tofessiorlalEirr r�# 60�'
�5+1
o of Florida
1 o N P` �� Page 1 of 1
OI:Ilit6��