Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED PDS 04122021 Conf Room Permit Cert Unlocked
I I I I I I St. Lucie County BOCC - - - - - - - - - - - - - - - - - - - - - - - - 2300 Virginia Avenue 1 ' Fort Pierce, Florida 34982 1 F H WALL AT CORNER I I CORRIDOR I T: 772.462.1100 I I I I I I I I I ROOF PAIR 30 DOORS TO MATCH BUILDING/CODE ° CONFERENCE ROOM FF COMBINATION WAITING ' ❑ I I I RECEPTACLE, EXISTd0J CTWME��S MECHANICAL I ELE AT R USB TR T RO M RI G 1 NEW WALLS 1 FLOORENTRA C I LOB Y TUN L Y I CONSTRUCTION , Y I RECEPTACLEEr I T - (EXISTING) FF7 General Contractor: ❑ I - I- - - - I - - ENLARGED T E T LLI ENLARGED , I_LI 1 FFI s� of o CONFERENCE I o, CONFERENCE 1 El EE EV OR — — — — w ROOM � ROOM OMEN'S CE Q I 628 SF I Q TO I I 1 d MEN'S 1 20'-4" I 1 - - - - - - ROOF - I EXIST'G. FLOOR ROOF CORRIDOR _ OUTLET ECEPTI N I 1 1 AREA OFI FIC I o - - 1 1 J - FOR - - - - NFEREN E 1 EXIST'G. 1 l<eyplan: U - - - - - - = DEPARTMENT OFFICES I I 1 1 DEPARTMENT OFFICES u — — — — — —E — — ILI I I I I I I I I I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � - - - - - - - - - - Existing Building Plan 1/32" = V-0" Improvements Plan 1/8" = 1'-0" Electrical Plan - - - - - - - - - - � - - - - - - - - - - - - - - _ � _ = Area of Improvements I I I Issues: 1 I No.: Date: Description: CORRIDOR I = 1 A 03.31.2021 REVIEW/COMMENT p--,\ ROOF I ❑° ❑° I A 04.09.2021 REVIEW/COMMENT II ------- - ❑ - - - - - - � - � - - � ; i 01 04.12.2021 PERMIT 1 -� �_____ I 4a------ PH , 4N'S 1 17� FV1 �_ i_ II � ------------ I ❑ — — — 1 ' 1 � 60„ I I C TOD L WALLS, DOORS, TO WE MECHANICAL I I ELE AT R RI 1 ❑° ❑° � BE REMOVED (TYP.) �i I FE FIRE ENTCRBA v Ro M EXTINGUISHER TUN G L W MEWS O NOTE: CEILING GRID _ _ o EI TO REMAIN AS IS ii MAXIMUM ° ❑ TO TO DO SO I I T ❑-4 TRAVEL Y OI =___-- - - - I D EPARTMENT - - - - - - - - - - - - - - - _ -- ---------------- _ DISTANCE FICESI ----- -- ------------ ° E EV OR F — — LL 1 � I EMERGENCY _ _ _ _ ❑❑ O I LIGHTING OMEN'S 0l �I I wl I w EMERGENCY ° TO W I G O O Q ® EXIT MEWS ROOF or NO : DROPPED CEILING Q PLEN UM TO COMPLY WITH ROOF ®E LAJ CORF IDOR I NEC300.20 AND NEC I � 300.21 I 103' AITING Project: � - � - � � � © XIST'G. � FE EN E p IMMER PH I o PH0 C) 3 IDS S FF ES J DE P RTMENT O�FICES PDS OFFICES o [FJI - - - - - - - - - - - - - - - - - — - - 1 Conference Room P 3ff} 3-WAY FLOURESCLNT FIXTURE PHIOTOSENSOR (2 'EYEBALL' F XTURE Planning and �l MER —L8D-CQNNECT TO ------- i E ti O 1 DIMMER SVyIT H 1 Development ----------------ILI- - -- ---- _f�=L_- I AIR SUPPLI� I - I Services E-1_ AIRRETURI`�l _ _ Fort Pierce, Florida Demolition Plan 1/8" = 1'-0" Life Safety Plan 1/32" = V-0" Reflected Ceiling Plan 1/8" = V-0° DEMOLITION NOTES: CODES REVIEW: CHAPTER 13 ENERGY EFFICIENCY 1. THIS DEMOLITION PLAN SHOWS GRAPHIC AND WRITTEN INFORMATION THE SCOPE OF WORK CONSISTS OF THE RECONFIGURATION OF AN EXISTING FLORIDA BUILDING CODE - ACCESSIBILITY, 7TH EDITION (2020) CONFERENCE ROOM, RECEPTION AREA AND OFFICE INTO A LARGER CONCERNING THE EXISTING SPACE. THIS IS INCLUDED AS CONFERENCE ROOM (628 SF) AND WAITING AREA (255 SF). THE OCCUPANCY NFPA 1 , FIRE CODE, FLORIDA EDITION Drawing Title: "INFORMATION ONLY" REPRESENTING AVAILABLE RECORD IS CONSIDERED TO BE BUSINESS GROUP 'B'. THE WORK CONSISTS OF FASTEN METAL TRACK TO INFORMATION OF THE ORIGINAL LEASE DRAWINGS PLUS FIELD INTERIOR IMPROVEMENTS, INCLUDING ELECTRICAL AND MECHANICAL. CHAPTER 1 ADMINISTRATION ACOUSTICAL CEILING GRID PDS NOTATIONS. SOME MODIFICATIONS MAY HAVE BEEN MADE AND NOT SECTEW CODES REFERENCED: CHAPTER 61O CLASSIFICATION N 1 .14 PLAN IOF OCCUPANCY CONFERENCE ROOM SHOWN. THIS INFORMATION IS FOR THE CONTRACTOR'S REFERENCE SECTION 6.1 CLASSIFICATION OF OCCUPANCY AS MAY BE USEFUL. FLORIDA BUILDING CODE 7TH EDITION (2020) 6.1 .11 BUSINESS IMPROVEMENTS FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020): CHAPTER 10 GENERAL SAFETY REQUIREMENTS 2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NFPA 1, NFPA 101 CHAPTER 14 MEANS OF EGRESS Drawn: Issue Date: DETERMINE THE SCOPE OF WORK REQUIRED. CHAPTER 20 OCCUPANCY FIRE SAFETY PWJ 04.12.2021 SYNOPSIS OF APPLICABLE CODES CHAPTERS/SECTIONS: SECTION 20.13 BUSINESS OCCUPANCIES 3. THE CONTRACTOR SHALL EXAMINE THE EXISTING BUILDING AND WORK FLORIDA BUILDING CODE - EXISTING, 7TH EDITION (2020) NFPA 101, LIFE SAFETY CODE, FLORIDA EDITION Checked: Scale: SHOWN BY ALL CONTRACT DOCUMENTS TO DETERMINE THE SCOPE OF DEMOLITION REQUIRED WHETHER SPECIFICALLY SHOWN OR NOT. CHAPTER 6 CLASSIFICATION OF WORK CHAPTER 4 GENERAL SECTION 603 ALTERATION - LEVEL 2 4.5.3 MEANS OF EGRESS = Project No.: Sheet No.: 4. REFER TO MECHANICAL&ELECTRICAL DEMOLITION NOTES AND MEP CHAPTER 7 ALTERATIONS - LEVEL 1 CHAPTER 6 CLASSIFICATION OF OCCUPANCY AND (D DOCUMENTS FOR EXTENT OF DEMOLITION OF THOSE SYSTEMS. CHAPTER 8 ALTERATIONS - LEVEL 2 HAZARD OF CONTENTS W 6.1 CLASSIFICATION OF OCCUPANCY A- 1 FLORIDA BUILDING CODE - BUILDING, 7TH EDITION (2020) 6.1 .11 BUSINESS O 5. PROTECT ALL EXISTING STRUCTURE, SYSTEMS, FINISHES AND CHAPTER 7 MEANS OF EGRESS z GENERAL CONSTRUCTION THAT ARE TO REMAIN THROUGHOUT THE ALUM. STUDS 16" O.C. WITH 1/E = J CHAPTER 2 DEFINITIONS 7.3 CAPACITY OF MEANS OF EGRESS DRYWALL EACH SIDE O w COURSE OF THE WORK TO PREVENT DAMAGE OR LOSS. CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION TABLE 7.3.1.2 OCCUPANT LOAD FACTOR O SECTION 304 BUSINESS GROUP B BUSINESS150 SF GROSS 6. CONTRACTOR IS TO VERIFY UTILITY LINE LOCATIONS AND MAINTAIN CHAPTER 10 MEANS OF EGRESS 7.6 MEASUREMENT OF TRAVEL DISTANCE TO EXITS Q THE ATTACHED PLANS HAVE BEEN DESIGNED FOR AND ARE SECTION 1004 OCCUPANT LOAD REFERENCE LIFE SAFETY PLAN IN COMPLIANCE WITH THE 7TH EDITIONS OF THE FLORIDA THOSE THAT SERVE OTHER PARTS OF THE BUILDING THAT ARE NOT 2 BUILDING CODE AND FLORIDA FIRE PREVENTION CODE. 1004.1 DESIGN OCCUPANT LOAD CHAPTER 10 INTERIOR FINISH, CONTENTS, AND FURNISHINGS DESIGN IS SITE SPECIFIC AND NOT VALID WITHOUT THE AFFECTED BY THE DEMOLITION. X TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER 10.1 GENERAL O AUTHORIZED SIGNATURE AND SEAL OF A REGISTERED OCCUPANT (REFERENCE LIFE SAFETY PLAN) 10.1.1 APPLICATION If: ARCHITECT.THESE NOTES ARE PART OF THE 7. PRIOR TO INTERRUPTING OR OTHERWISE AFFECTING ANY SUCH CONFERENCE ROOM 20 SF NET PROVISIONS IN THIS CHAPTER SHALL APPLY D_ CONSTRUCTION DOCUMENTS.DO NOT SCALE THESE OPERATING SYSTEM, UTILITY OR SERVICE, CONTRACTOR SHALL ALLOWING FOR TABLE 600 SF/20 = 30 OCCUPANTS CHAPTER 39 EXISTING BUSINESS OCCUPANCIES D_ DRAWINGS,USE FIGURED DIMENSIONS ONLY.IF A Q DISCREPANCY OCCURS,CONTACT THE ARCHITECT FOR CONSULT WITH OWNER'S REPRESENTATIVE TO ESTABLISH A SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS 39.1 GENERAL REQUIREMENTS CLARIFICATIONS. MUTUALLY SATISFACTORY SCHEDULE FOR CUT OVER, CUT OFF TABLE 1006.2.1 SPACES WITH ONE EXIT OR 39.1.1 APPLICATION DISRUPTION OR OTHER CHANGE IN THE OPERATION OF THE AFFECTED EXIT ACCESS DOORWAY PROVISIONS OF THIS CHAPTER SHALL APPLY CHAPTER 11 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION METAL TRACK WITH 3/4 TRACK SYSTEM, UTILITY OR SERVICE. CHAPTER 12 INTERIOR ENVIRONMENT FAST PINS EVERY 12" O.C. y SECTION 1210 SURROUNDING MATERIALS Q 8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE ° y IN ACCORDANCE WITH THAT TRADE'S BEST INDUSTRY STANDARDS. ° Pets° o VINYL BASE (TYP.) �0° 9. NOISE AND DUST IS NOT TO BE DISRUPTIVE TO THE OCCUPIED AREA OF �� o S°o O THE BUILDING. PROVIDE TEMPORARY PARTITIONS AS REQUIRED. ° o b o o ®®Jte: 10. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER SO O° AS NOT TO DAMAGE FINISHES OR EQUIPMENT TO REMAIN. �'� 202 Q 04.12.2021 Typical Wall Section Peter W. Jones Date Yp 3/4" = 1'-0" AR0017858