Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, - ENERGY CALC
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TINDALL RESIDENCE Builder Name: Street: 11652 ORANGE AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(3801.5 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead Age=0.0 3505.50 ft2 b. Frame - Wood, Adjacent R=11.0 296.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 10. Ceiling Types (3710.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3710.00 ft2 6. Conditioned floor area above grade (ft2) 3710 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(465.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 175 a. U-Factor: Sgl, U=0.31 280.00 ft2 b. Sup: Attic, Ret: Attic, AH: AHU CLST 6 125 SHGC: SHGC=0.19 b. U-Factor: Sgl, U=0.33 128.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 42.0 SEER:16.00 b. Central Unit 17.7 SEER:16.00 c. U-Factor: Sgl, U=0.30 45.00 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 12.00 ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 7.116 ft. Area Weighted Average SHGC: 0.201 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (3710.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3710.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.125 Total Proposed Modified Loads: 113.01 PASS Total Baseline Loads: 113.64 I hereby certify that the plans and specifications covered by Review of the plans and t � G this calculation are in compliance with the Florida Energy specifications covered by this l� Code. calculation indicates compliance G'00 with the Florida Energy Code. D BY: PREPARED BY: Before construction is completed DATE: R this building will be inspected for �N E S compliance with Section 553.908 0� I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes.ti' C7 ��i,�p� �.�`�•••�` OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY GFiEGKLIST REPORT PROJECT Title: TINDALL RESIDENCE Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 3710 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 11652 ORANGE AVEN Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL , New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2493 32886 2 AHU 2 1217 12170 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 MUD ROOM 175 1750 No 0 1 No Yes Yes 2 UTILITY RM 100 1000 No 0 1 Yes Yes Yes 3 POWDER RM 36 360 No 0 1 No Yes Yes 4 M WIC 1 126 1260 No 0 1 No Yes Yes 5 M W IC 2 99 990 No 0 1 Yes Yes Yes 6 M TOILET 35 350 No 0 1 Yes Yes Yes 7 M BATH 220 2200 No 0 1 Yes Yes Yes 8 MASTER BEDROO 270 2700 No 0 1 Yes Yes Yes 9 KITCHEN 334 5511 No 0 1 Yes Yes Yes 10 LIVING/DINING 770 12705 No 0 1 Yes Yes Yes 11 PANTRY 104 1040 No 0 1 Yes Yes Yes 12 FOYER 120 1980 No 0 1 Yes Yes Yes 13 DEN 104 1040 No 0 1 Yes Yes Yes 14 BEDROOM 4 225 2250 No 0 1 Yes Yes Yes 15 WIC 4 54 540 No 0 1 Yes Yes Yes 16 HALL 4 42 420 No 0 1 Yes Yes Yes 17 AHU CLST 18 180 No 0 1 No Yes Yes 18 TOILET 24 240 No 0 1 No Yes Yes 19 HALL CLST 18 180 No 0 1 No Yes Yes 20 HALL 3 72 720 No 0 1 No Yes Yes 21 SINKS 4 72 720 No 0 1 No Yes Yes 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY GFiEGKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 BATH 4 54 540 No 0 1 Yes Yes Yes 23 WIC 3 54 540 No 0 1 Yes Yes Yes 24 BEDROOM 3 210 2100 No 0 1 Yes Yes Yes 25 BATH 3 109 1090 No 0 1 Yes Yes Yes 26 BEDROOM 2 232 2320 No 0 1 Yes Yes Yes 27 CLST 2 33 330 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MUD ROOM 1 ft 0 175 ft2 1 0 0 2 Slab -On -Grade Edge Insulatio UTILITY RM 8 ft 0 100 ft2 1 0 0 3Slab-On-Grade Edge Insulatio POWDER RM 1 ft 0 36 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio M W IC 1 1 ft 0 126 ft2 1 0 0 5SIab-On-Grade Edge Insulatio M WIC 2 20 ft 0 99 ft2 1 0 0 6 Slab -On -Grade Edge Insulatio M TOILET 12 ft 0 35 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio M BATH 20 ft 0 220 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulatio MASTER BEDRO 27 ft 0 270 ft2 ___ 1 0 0 9 Slab -On -Grade Edge Insulatio KITCHEN 16 ft 0 334 ft2 1 0 0 10SIab-On-Grade Edge Insulatio LIVING/DINING 35 ft 0 770 ft2 1 0 0 11SIab-On-Grade Edge Insulatio PANTRY 13 ft 0 104 ft2 1 0 0 12SIab-On-Grade Edge Insulatio FOYER 16 ft 0 120 ft2 1 0 0 13SIab-On-Grade Edge Insulatio DEN 13 ft 0 104 ft2 1 0 0 14SIab-On-Grade Edge Insulatio BEDROOM 4 30 ft 0 225 ft2 1 0 0 15SIab-On-Grade Edge Insulatio WIC 4 15 ft 0 54 ft2 1 0 0 16SIab-On-Grade Edge Insulatio HALL 4 4 ft 0 42 ft2 ___ 1 0 0 17SIab-On-Grade Edge Insulatio AHU CLST 1 ft 0 18 ft2 1 0 0 18SIab-On-Grade Edge Insulatio TOILET 1 ft 0 24 ft2 ___ 1 0 0 19SIab-On-Grade Edge Insulatio HALL CLST 1 ft 0 18 ft2 1 0 0 20SIab-On-Grade Edge Insulatio HALL 3 1 ft 0 72 ft2 ___ 1 0 0 21SIab-On-Grade Edge Insulatio SINKS 4 1 ft 0 72 ft2 1 0 0 22SIab-On-Grade Edge Insulatio BATH 4 6 ft 0 54 ft2 ___ 1 0 0 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 23SIab-On-Grade Edge Insulatio WIC 3 6 ft 0 54 ft2 1 0 0 24SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 210 ft2 1 0 0 25SIab-On-Grade Edge Insulatio BATH 3 23 ft 0 109 ft2 1 0 0 26SIab-On-Grade Edge Insulatio BEDROOM 2 29 ft 0 232 ft2 1 0 0 27SIab-On-Grade Edge Insulatio CLST 2 1 ft 0 33 ft2 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 4297 ft2 1084 ft2 Light N 0.2 No 0.9 No 20 30.3 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3710 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MUD ROOM 0 Blown 175 ft2 0.1 Wood 2 Under Attic (Unvented) UTILITY RM 0 Blown 100 ft2 0.1 Wood 3 Under Attic (Unvented) POWDER RM 0 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) M WIC 1 0 Blown 126 ft2 0.1 Wood 5 Under Attic (Unvented) M WIC 2 0 Blown 99 ft2 0.1 Wood 6 Under Attic (Unvented) M TOILET 0 Blown 35 ft2 0.1 Wood 7 Under Attic (Unvented) M BATH 0 Blown 220 ft2 0.1 Wood 8 Under Attic (Unvented) MASTER BEDRO 0 Blown 270 ft2 0.1 Wood 9 Under Attic (Unvented) KITCHEN 0 Blown 334 ft2 0.1 Wood 10 Under Attic (Unvented) LIVING/DINING 0 Blown 770 ft2 0.1 Wood 11 Under Attic (Unvented) PANTRY 0 Blown 104 ft2 0.1 Wood 12 Under Attic (Unvented) FOYER 0 Blown 120 ft2 0.1 Wood 13 Under Attic (Unvented) DEN 0 Blown 104 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 4 0 Blown 225 ft2 0.1 Wood 15 Under Attic (Unvented) WIC 4 0 Blown 54 ft2 0.1 Wood 16 Under Attic (Unvented) HALL 4 0 Blown 42 ft2 0.1 Wood 17 Under Attic (Unvented) AHU CLST 0 Blown 18 ft2 0.1 Wood 18 Under Attic (Unvented) TOILET 0 Blown 24 ft2 0.1 Wood 19 Under Attic (Unvented) HALL CLST 0 Blown 18 ft2 0.1 Wood 20 Under Attic (Unvented) HALL 3 0 Blown 72 ft2 0.1 Wood 21 Under Attic (Unvented) SINKS 4 0 Blown 72 ft2 0.1 Wood 22 Under Attic (Unvented) BATH 4 0 Blown 54 ft2 0.1 Wood 23 Under Attic (Unvented) WIC 3 0 Blown 54 ft2 0.1 Wood 24 Under Attic (Unvented) BEDROOM 3 0 Blown 210 ft2 0.1 Wood 25 Under Attic (Unvented) BATH 3 0 Blown 109 ft2 0.1 Wood 26 Under Attic (Unvented) BEDROOM 2 0 Blown 232 ft2 0.1 Wood 27 Under Attic (Unvented) CLST 2 0 Blown 33 ft2 0.1 Wood --=020 12:03 PM EnergyGauge@ USA 6.0.02 Rev. 1) - FlaRes2017 FBC 6th Edition 2017 Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowo OrntIn Space In 1 S Garage Frame - Wood MUD ROOM 11 13 0 10 0 130.0 ft2 0 0.1 0.2 0 2 W Exterior Concrete Block - Polyst*ITALITY RM 0 8 0 10 0 80.0 ft2 0 0 0.2 0 3 S Garage Frame - Wood UTILITY RM 11 10 0 10 0 100.0 ft2 0 0.1 0.2 0 4 S Exterior Concrete Block - Polystyr&4 WIC 2 0 9 0 10 0 90.0 ft2 0 0 0.2 0 5 W Exterior Concrete Block - Polystyr&4 WIC 2 0 11 0 10 0 110.0 ft2 0 0 0.2 0 6 N Exterior Concrete Block - PolystyrkbTOILET 0 5 0 10 0 50.0 ft2 0 0 0.2 0 7 W Exterior Concrete Block - PolystykbTOILET 0 7 0 10 0 70.0 ft2 0 0 0.2 0 8 N Exterior Concrete Block - PolystyrdO BATH 0 12 0 10 0 120.0 ft2 0 0 0.2 0 9 W Exterior Concrete Block - PolystyrdO BATH 0 8 0 10 0 80.0 ft2 0 0 0.2 0 10 N Exterior Concrete Block - PolystMASTER BE 0 15 0 10 0 150.0 ft2 0 0 0.2 0 11 E Exterior Concrete Block - PolystM"TER BE 0 9 0 10 0 90.0 ft2 0 0 0.2 0 12 W Exterior Concrete Block - Polysty"TER BE 0 3 0 10 0 30.0 ft2 0 0 0.2 0 13 E Exterior Concrete Block - PolystyrKhTCHEN 0 2 0 16 6 33.0 ft2 0 0 0.2 0 14 S Exterior Concrete Block - PolystyrIOTCHEN 0 14 0 16 6 231.0 ft2 0 0 0.2 0 15 W Garage Frame - Wood KITCHEN 11 4 0 16 6 66.0 ft2 0 0.1 0.2 0 16 S Exterior Concrete Block - PolystWNG/DINT 0 35 0 16 6 577.5 ft2 0 0 0.2 0 17 N Exterior Concrete Block - PolystyrR ANTRY 0 13 0 10 0 130.0 ft2 0 0 0.2 0 18 N Exterior Concrete Block - PolystyreFOYER 0 12 0 16 6 198.0 ft2 0 0 0.2 0 19 E Exterior Concrete Block - PolystyreFOYER 0 2 0 16 6 33.0 ft2 0 0 0.2 0 20 W Exterior Concrete Block - PolystyreFOYER 0 2 0 16 6 33.0 ft2 0 0 0.2 0 21 N Exterior Concrete Block - PolystyrenDEN 0 13 0 10 0 130.0 ft2 0 0 0.2 0 22 E Exterior Concrete Block - Polystt EDROOM 4 0 15 0 10 0 150.0 ft2 0 0 0.2 0 23 S Exterior Concrete Block - PolysitjiEDROOM 4 0 15 0 10 0 150.0 ft2 0 0 0.2 0 24 S Exterior Concrete Block - PolystyrerW IC 4 0 6 0 10 0 60.0 ft2 0 0 0.2 0 25 W Exterior Concrete Block - PolystyrerW IC 4 0 9 0 10 0 90.0 ft2 0 0 0.2 0 26 W Exterior Concrete Block - PolystyreNALL 4 0 4 0 10 0 40.0 ft2 0 0 0.2 0 27 E Exterior Concrete Block - PolystyreBATH 4 0 6 0 10 0 60.0 ft2 0 0 0.2 0 28 E Exterior Concrete Block - PolystyrerW IC 3 0 6 0 10 0 60.0 ft2 0 0 0.2 0 29 E Exterior Concrete Block - PolysitjiEDROOM 3 0 14 0 10 0 140.0 ft2 0 0 0.2 0 30 N Exterior Concrete Block - PolystyreBATH 3 0 15 0 10 0 150.0 ft2 0 0 0.2 0 31 E Exterior Concrete Block - PolystyreBATH 3 0 8 0 10 0 80.0 ft2 0 0 0.2 0 32 N Exterior Concrete Block - Polys*EDROOM 2 0 17 0 10 0 170.0 ft2 0 0 0.2 0 33 E Exterior Concrete Block - PolysitjiEDROOM 2 0 3 0 10 0 30.0 ft2 0 0 0.2 0 34 W Exterior Concrete Block - PolysWDROOM 2 0 9 0 10 0 90.0 ft2 0 0 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated MUD ROOM None .17 2 8 8 21.3 ft2 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Wall # Ornt ID Frame Panes 1 W 2 Vinyl Low-E Single 2 N 8 Vinyl Low-E Single 3 W 9 Vinyl Low-E Single 4 N 10 Vinyl Low-E Single 5 S 14 Vinyl Low-E Single 6 S 16 Vinyl Low-E Single 7 S 16 Vinyl Low-E Single 8 N 17 Vinyl Low-E Single 9 N 18 Vinyl Low-E Single 10 N 18 Vinyl Low-E Single 11 N 21 Vinyl Low-E Single 12 E 22 Vinyl Low-E Single 13 E 29 Vinyl Low-E Single 14 N 30 Vinyl Low-E Single 15 N 32 Vinyl Low-E Single # Floor Area 1 690 ft2 Ceiling Area 690 ft2 WINDOWS Orientation shown is the entered, Propo NFRC U-Factor SHGC I Yes 0.25 0.23 Yes 0.3 0.21 Yes 0.3 0.21 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.33 0.22 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.31 0.19 Yes 0.3 0.21 Yes 0.31 0.19 GARAGE Exposed Wall Perimeter 27 ft INFILTRATION sed orientation m Overhang p Area Depth Separation Int Shade Screening Y 12.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 Y 15.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 Y 15.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 Y 36.0 ft2 1 ft 0 in 1 ft 4 in None None Y 20.0 ft2 12 ft 0 in 1 ft 4 in None None Y 32.0 ft2 12 ft 0 in 1 ft 4 in None None Y 128.0 ft2 12 ft 0 in 1 ft 4 in None None Y 24.0 ft2 10 ft 0 in 1 ft 4 in None None Y 16.0 ft2 10 ft 0 in 1 ft 4 in None None Y 32.0 ft2 10 ft 0 in 1 ft 4 in None None Y 24.0 ft2 10 ft 0 in 1 ft 4 in None None Y 30.0 ft2 1 ft 0 in 1 ft 4 in None None Y 30.0 ft2 1 ft 0 in 1 ft 4 in None None Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None Y 36.0 ft2 1 ft 0 in 1 ft 4 in None None Wall H loft Wall Insulation 11 # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .000386 3754.7 206.13 387.65 .158 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 2 Central Unit/ Split Singl SEER: 16 17.7 kBtu/hr 531 cfm 0.8 2 sys#2 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 Wall H loft Wall Insulation 11 # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .000386 3754.7 206.13 387.65 .158 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 2 Central Unit/ Split Singl SEER: 16 17.7 kBtu/hr 531 cfm 0.8 2 sys#2 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage Garage (Default) (Default) 1 1 2 Attic 6 125 ft2 Attic 13 ft2 Default Leakage AHU CLST (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan F eb Mar pr May Jun Oct Nov Dec H �X� IM �X� �X� Jun Jul j Aug r Sep �X� Oct NovOct FFeb JJanan eb Venting Maar r Apr May Jun [ Jul lX� lX� Aug [ Sep l lx Nov lXDDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MUD ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER RM Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 4 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 SINKS 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 12/8/2020 12:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.