BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL10674-R16
Application Type Revision
Code Version 2020
Application Status Pending FBC Approval
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation
Report
Robert J.M. Nieminen
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10674_R16_COI_2020_01_COI_NIEMINEN.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2019
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/11/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Summary of Products
FL #Model, Number or Name Description
10674.1 Owens Corning Asphalt Roofing Shingles and
Starters
3-tab, 4-tab, laminated, starter and hip & ridge shingles
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Installation Instructions
FL10674_R16_II_2020_12_11_FINAL_ER_OC_ASPHALT SHINGLES_FL10674-
R16.pdf
Verified By: Robert J. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10674_R16_AE_2020_12_11_FINAL_ER_OC_ASPHALT SHINGLES_FL10674-
R16.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by
phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must
provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply
a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
Evaluation Report O37940.02.12-R11
FL10674-R16
Date of Issuance: 02/06/2012
Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 12/11/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2018 NEMO ETC, LLC
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 2 of 10
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5, R905.2.4 Material standard ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019
3. REFERENCES:
Entity Examination Reference Date
Owens Corning Declaration Equivalency Declaration 08/06/2019
PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014
UL LLC (TST9628) Physical Properties Classification letter 10/02/2015
PRI (QUA9110) Quality Control Service Confirmation 04/05/2020
PRI (QUA9110) Quality Control Florida BCIS Current
4. PRODUCT DESCRIPTION:
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type Product Plant(s) Material
Standard Description
Accessory
Starter
Strips
Starter Strip Shingle H-TX, OR
ASTM D3462 starter strips for asphalt roof shingles Starter Strip Plus MN, OR
SRS TopShield Starter MN, OR
Starter Shingle Roll NH ASTM D1970 mineral-surfaced, fiberglass-reinforced,
self-adhering SBS modified bitumen starter
Asphalt
Shingles
Supreme® GA, CA, CO, I-TX, NJ, OH,
TN, OR, IL ASTM D3462 fiberglass reinforced 3-tab asphalt
roof shingles
Berkshire® MN ASTM D3462 fiberglass reinforced, 4-tab asphalt
roof shingles
Duration® Premium CA, OR
ASTM D3462 fiberglass reinforced, laminated
asphalt roof shingles
Duration® Premium COOL CA
TruDefinition® Duration® IN, CA, CO, I-TX, FL, NJ, OH,
MN, OR, GA, IL, TN TruDefinition® Duration®
Designer Color Collection
Oakridge® GA, IN, CA, CO, H-TX, I-TX,
FL, NJ OH, TN
TruDefinition® Oakridge® H-TX, I-TX
WeatherGuard® HP TN
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 3 of 10
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type Product Plant(s) Material
Standard Description
Hip and
Ridge
Shingles
Berkshire® Hip and Ridge
Shingles with Sealant MN
ASTM D3462 fiberglass reinforced, hip and ridge
asphalt roof shingles
DuraRidge® Hip and Ridge
Shingles with Sealant MN
ProEdge® GA, CA, OH, OR
WeatherGuard® HP Hip and
Ridge Shingles TN
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES
Product FBC Table 1507.2.7.1 or R905.2.6.1
Supreme®
ASTM D3161(F) & ASTM D7158(H)
Berkshire®
Duration® Premium
Duration® Premium COOL
TruDefinition® Duration®
TruDefinition® Duration® Designer Color Collection
Oakridge®
TruDefinition® Oakridge®
WeatherGuard® HP
5.5.1 Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 4 of 10
TABLE 2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE
Type Product FBC Table 1507.2.7.1 or R905.2.6.1
Starter Strips
Starter Strip Shingle
ASTM D3161, Class F Starter Strip Plus
SRS TopShield Starter
Hip & Ridge
Shingles
Berkshire® Hip and Ridge Shingles with Sealant
ASTM D3161, Class F DuraRidge® Hip and Ridge Shingles with Sealant
ProEdge®
WeatherGuard® HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6. INSTALLATION:
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer’s minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer’s published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear-off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Figure 1: Minimum Nailing, Starter Strip
Figure 2: Minimum Nailing, Starter Strip Plus
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 5 of 10
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Figure 3: Starter Shingle Roll
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire® shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Figure 4: Minimum Nailing, Supreme
(Standard Size)
Figure 5: Minimum Nailing, Supreme
(Metric Size)
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 6 of 10
6.3.1.2 Berkshire®:
Figure 6: 5-Nail Pattern, Berkshire
Figure 7: 6-Nail Pattern, Berkshire
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 7 of 10
6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition® Duration® Designer Color
Collection:
Figure 9: Standard 4-Nail Pattern, Duration
Figure 10: 6-Nail Pattern, Duration
Figure 11: Mansard or Steep Slope Pattern, Duration
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 8 of 10
6.3.1.4 TruDefinition® Oakridge®, Oakridge®:
Figure 12: Standard 4-Nail Pattern, Oakridge
Figure 13: 6-Nail Pattern, Oakridge
Figure 14: Mansard or Steep-Slope Pattern, Oakridge
6.3.1.5 WeatherGuard® HP:
Figure 15: 6-Nail Pattern, WeatherGuard HP
Figure 16: Mansard or Steep-Slope Pattern, WeatherGuard HP
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 9 of 10
6.4 HIP AND RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant:
Figure 17: Isometric View, Berkshire and DuraRidge
Figure 18: Plan View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles:
Figure 19: Isometric View, WeatherGuard HP Hip and Ridge
Figure 20: Plan View, WeatherGuard HP Hip and Ridge
NEMO|etc.
NEMO ETC, LLC Evaluation Report O37940.02.12-R11
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 10 of 10
6.4.1.3 ProEdge®:
Figure 21: Isometric View, ProEdge
Figure 22: Plan View, ProEdge
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC– QUA9110 ; (813) 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -