HomeMy WebLinkAboutLUCAS UNVENTED ATTIC20210423FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
, ST. LUCIE COUNTY, FL,
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=5.0
2520.00 ft2
b. Frame - Wood, Adjacent
R=13.0
300.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
2
d. N/A
R=
ft2
11. Ceiling Type and insulation level
insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0
1777.00 ft2
6. Conditioned floor area (ft2)
1777
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows" Description
Area
12. Ducts, location & insulation level
Z
R ft
a. U-Factor: S I, U=1.04
g
264.00 ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 355.4
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
44.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
31.0
COP:1.00
Area Weighted Average Overhang Depth:
9 9
6.727 ft.
Area Weighted Average SHGC:
0.250
8. Skylights Description
Area
15. Hot water systems
Cap:
50 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.97
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1777.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be Installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/23/2021 10:49 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
OwnerName:
# of Units:
BuilderName:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
LUCAS
User
PAUL LUCAS
1
Detached
New (From Plans)
Bedrooms: 2
Conditioned Area: 1777
Total Stories: 1
Worst Case: No
RotateAngle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street:
County: St. Lucie
City, State, Zip: ST. LUCIE COUNTY,
FL,
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1777 17770
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
ZONE 1
1777 17770 Yes 2
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation ZONE 1 252 ft 0
1777 ft2
-__- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Metal 1987 ft2 0 ft2 Medium
N
0.96 No 0.9 No 20 26.57
ATTIC
V #
T
Type
Ventilation Vent Ratio 1 in
( )
Area
RBS IRCC
1
Fullattic
Unvented 0
1777 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
UnderAttic (Unvented)
ZONE 1 20 Blown
1777 ft2 0.11 Wood
4/23/2021 10:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4