Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning &Development Services Department ` Building & Code Regulations Division }. 230,E Virginia Avenuet'Fort Pieice, 1711` `34§k' :'(7.7r�) t { = Certifitation for Design Load Compliance ,, v ;1-, �' s Loi:,5� Diamond Sands Miranda Res t Project Name: . '' Project Address + i Permit #: J Occ aric T e ConstructiYn up Y,. - YP 4 Ty`P� 1 � INSTRUCTIONS FOR USE: • This certification, must be com leted, signed, and,sealed b thfess onaof record:e'desi n ro' f ' • Subrrrit (2) copies fn residentiel,,(3) copies-#tir;comMercial with all perKt �t`applications involving,the following': g o "New Residences (single or multi familv7 o ,.Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note ­. Form -not requir,,ed:for. interior renoj ation provided thaitino ext,,., r structuwal e errfe 4t pre�effec ed°and., certain minor building peymits at the discretion of the local:bur1dmg official. Contact,the #'above fort restions DESIGN. PARAMETERS AND ASSUMPTIONS USED: (complete al('that 6pply) 1. DESIGN CODE: Florida 201 7_ Code,j fifth Edition wit(r 20 jSup`{�leirients using ASCE 7=1b°. 2' Structure Designed as (check one) x Enclosed_ . _Par'trally Enclosed` '° F Operr (o7` 3. Risk Category: I 1 11L Hi' IV Exposure Category' Design Wind Velocity 170 ';' 'm)h •.ASD x I RFp ^ bndZdmedtr. 8�,;�aft,,� 5 r 5. IVIearl:Roof Height ' 0 ft Roof. P[tch 5- -12 _Parapet s r 6. Com6onents & Cladding Desrgn Pressures Used: (PSF, based on 10sgft @ t5 MF}H„clearly'(abcIf0.` ab6plydn�b�p/er,ipgs) ZoneJ1: see, plans ZQ�n'e 2 seeplans` Zone 3:`see piaris Zone-ee`pins Z ne 5 see plans'Garage se"n�`' 7. Design Load :Flgor: 40� S Roof/Dead 25 6 (?SF. Roof/Line{- 30 Balcony 50 .,-,pock--'11Qn�' P.SFDeck� 50 4 PSF Stairs 60-PSFence'u D+One ` ' .CtQ� F "PSF Railings QS . . , 8. Were Shear Walls Gon5ldered For Structure? x" Yes Notpplrcable Explair#Nlhy(Vot 9. Is A Continuous "Load Path Prbvided7 ,X Yes Not Appl+Fable Explain`Why Not: 10. Design Soil Bearing Pressure {�IImB _ PSF Soil Test Reports Subm►tted? x '- Ye DESiGN PROFESSIO'NAL':CER7`IFICATION STATEMENT.. I certify tha't;•.to the'best of Yiy'knoWledg4 and belief, th'e attached plans& specificatioos have been designed to '" corricurrentp`oLuciepwtl'epicb)e'struturalportionsof thebuilding codes elwith y t County. I also -c ifythat'str"uctural elements depicted on:these_'plans provid4adequate rebistance to'the dEsFgn forces speVifie ��`� �� ... - • • GSA, ��'% Robert E. �Agsten 111 a .;� 7 ' (P 43205 GA" 8340 OGENg Print Name F '`Celt#,,& -•Co. CeTt-,Auth. o. 4 Agsten Engineering; Inc_,: ram, 3000 FLorida.�Blvd. '#206-, _Delia Bead' FL ;33483 Signaur91 Date, a Seal Y J ��0'• Company Name & Addiess� -