Loading...
HomeMy WebLinkAboutAERIAL PRECAST CONCRETE & STRUCTURAL STEELLOT 5 LOT MIRANDA RESIDENCE 5 - DIAMONDS SANDS, IENSEN BEACH, FL AERIAL PRECAST CONCRETE & STRUCTURAL STEEL MDP ENGINEERING State of Florida CA #6918 Registered Engineer #32563 (954) 243-4595 �Ovl LOT 5 MIRANDA RESIDENCE LOT 5 - DIAMONDS SANDS, JENSEN BEACH, FL INDEX TITLE...............................................................................................1 INDEX.............................................................. ................................ 2 JOISTCALC............................ :...................................................... 3 i I BEAMCALCS............................................................................................16 COLUMN CALCS......................... !............................................................ 36 CONNECTION CALCS...................................................................39 O W , doy.- /q'� AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, JOIST CALC 1 of 13 /�I� 3200 BURRIS ROAD SERIAL PRECAST CONCRETE JENSEN BEACH FL 11/1104 UPDATI ' Design: T.D.Y. Date: 08/21/19 DAVIE, FLORIDA 33314 e srRucruwALsrEEL T 954-321-0200 • F 954.321.0093 ° (2ND FLOOR) Checked: Date: sea,Ore*%%AERIALFLOOR SHOP DWGSLAF-2oleawe-Mian"Rau—waccaxsuidc�g1A-DI74.orwfl-)A�J r0.0 1 DESIGNPLANET Programmed by: Fuat Omadi, P.E P, P2 P3 INPUT 1 JOIST NO 1 J1=D17 4.0' (2nd floor); SPAN Manual input governs—> 4.000 14 t ♦ QI Q2 103 1 SLAB WIDTH 4.0 Ft DL+LL 1.14 k x2 1.14 k JOIST DEPTH ! 17- . DL+Wind 0.62 k 0.62 k Uniform Point Loads Applied at top_ Dist. From left support SERVICE DEAD LOAD' 65 78 Psf Pt: �. SERVICE LIVE LOAD 40 64 Psf P2:.: WIND LOAD(gross Uplift) P3: TOTAL LOAD=DL+LL 568 Plf Point Loads Applied at bolt. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) 312 Pif Qt: r F y (BOTi. ANGLES) 50 Ksi Q2: ' Fc' 3 Ksi 03: DESIGN OF BOTTOM CHORD P'tl'Yr i i �MIDSRANI MAX. MOMENT 566 Ft-Lbs TENSION AT BOTTOM CHORD ! 400 Lbs As req'd = Max(Tu/0.9*Fy AND Tu/0.75*Fu) 0.009 in2 OK As ( 2L'S) 2L-lxlxl/8 —_-- As=0.46 -- 1n2 TOP CHORD NONE DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) 1136 Lbs REACTION (DL+Wind) 624 Lbs LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) 1136 Lbs Diagonal Length 19.04 in. END DIAGONAL Tension bar i a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 0.17 k / 0.578 = 0.29 k As=F/ r2x(0.60 fvll = 0.14 / 36.0 = MAX. QTY MARK DEPTH BASE 1 J1-D17 4.0' (2nd floor). 17 in 1 4.0 Ft F(wind case)= 0.09 k / 0.58 = 0.16 k 0.00 in2 (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING V's 2L-1xlx1/8 NONE 1 (2) 1/2 1/2" *) Use the same up to the centedne,`'/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1 D17 SP J1 D17 = GIRDER JOIST. ie: SPA D17 (SRINDICATES SPECIAL JOIST) i AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS 1 JOIST CALC 2 of 13 A�qC 3200 BURRIS ROAD' 4ERIAL PRECAST CONCRETE ' JENSEN BEACH; FL 11/1/04 UPDATE DAVIE, FLORIDA 33314 s srRucrulv+LsrEEL__. T 954-321-0200 • F 954-321-0093 (2ND FLOOR) Design: T.D.Y. Date: 08121/19 Checked: Date: ShmD.W-IAERIAL FLOOR SHOP OWGS1AF-201WAS-Mh1A.R.1d—,1APGCMC1U.4t Cak112 J143171/.75Rbd W.YalG+ fty Denim DFSIGNPI ANFT Proarammed bv: Fuat Omarli. P.E INPUT JOIST NO SPAN . SLAB WIDTH JOIST DEPTH P, P2 _ P3 1 1 1 2 J1-Di1714.75' (2nd floor). Manual input governs—'> 14.750 ` 14.75 V t ♦ Q, Q2 Q3 4.0 Ft DL+LL 4.19 k x2 t 4.19 k 17" • DL+Wind 2.30 k 2.30 k Uniform Point. Loads Applied at top Dist. From left support SERVICE DEAD LOAD 65 78 Psf Pj: SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (80T7. ANGLES) Fe' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD AS reqd = Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length i— P3- ; 568 Plf Point Loads Applied at bott. Dist. From left support 312 Plf Q{ 50 Ksi Q2: 3 Ksi Q3: 14618 Ft-Lbs 10319 Lbs 0.229 in2 OK r I2L-lxlxl/8 As=0.46 .NONE END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 3.22 k / 0.578 = 5.57 k As=F/ 12x(0.60 fv)l = 2.78 / 36.0 = MAX. QTY MARK DEPTH BASE 2 J1-D1714.75' 2nd floor . 17 in 1 14.8 Ft 4189 Lbs 2301 Lbs 19.04 in F(wind case)= 0.08 in2 -w n2 1.77k /0.58= 3.06k (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAIN G Vs 2L-1xix1/8 NONE (2) 1/2 5/8" 1/2" *) Use the same up to the centerine; /L *) Symmetrical configuration shall`apply, after the centerline Abreviation: i N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1 D17 SP J1 D17 = GIRDER JOIST ie: SPA D1 7 (SP INDICATES SPECIAL JOIST) 0 A AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, JOIST CALC 3 r of 13 3200 BURRIS ROAD JENSEN BEACH FL 11/1/04 UPDATI AL \ERIPRECAST CONCRETE DAVIE, FLORIDA 33314 ' Design: T.D.Y. Date: 08/21/19 STRUC7URALSTEEL T 954-321-0200 • F 954-321-0093 (2ND FLOOR) 9 Checked: Date: L1Shop Dia hplAERIAL FLOOR SHOP DWGSIAF-20151Lo15-Mianda RmW=dAPC CakslJoisl CaMp J4-017 ISISMW fo4gslGr 4Uaip ULbIUNF'LANtI Nrogrammea by: t-uat umant, r.t. PI 02 P3 INPUT i JOIST NO 3 J2-D1716.75' (2nd floor), -- SPAN Manual input governs—> 16.750 116.75 w t ♦ Q, Q2 Q3 t SLAB WIDTH 4.0_Ft DL+LL 4.76 k x2 4.76 k JOIST DEPTH 17" • DL+Wind 2.61 k 2.61 k Uniform Point Loads Applied at top Dist. From left support SERVICE DEAD LOAD 65 78 Psf Pj: SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) P3: TOTAL LOAD=DL+LL 568 Plf Point Loads Applied at bott. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) 312 Plf QI: Fy (BOTT. ANGLES) 50 Ksi . Q2: Fc' 3 Ks! Q3: DESIGN OF BOTTOM CHORD `@ MIDSPANI MAX. MOMENT TENSION AT BOTTOM CHORD As reld = Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length 18839 Ft-Lbs 13298 Lbs 0.296 in2 OK 2L-lxlxl/8 As=OA6 n2 NONE END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 3.79 k / 0.578 = 6.55 k As=F/ 12x(0.60 full = 3.28 / 36.0 = MAX. QTY MARK DEPTH BASE 3 J2-D1716.75' (2nd floor). � 17 in 1 16.8 Ft 4757 Lbs 2613 Lbs 11.1 — 19.04 in F(wind case)= 0.09 in2 2.08 k / 0.58 = 3.60 k (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING VS 2L-lxlxl/8 NONE 1 (2) 1/2 3/4" 5/8" 1/2" *) Use the same up to the centedne,` /L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1D17 SP J1 D17 = GIRDER JOIST le: SPJ1D1 i (SP INDICATES SPECIAL JOIST) d AERIAL PRECAST CONCRETE, LLC AL 3200 BURRIS ROAD AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 dT sTRucruRALSTEEL� T 954-321-0200 • F 954-321.0093 LOT 5 DIAMONDS SANDS, JENSEN BEACH, FL (2ND FLOOR) JOIST CALC 4 of 13 1111104 UPDATE T.D.Y. Date: 09/21/19 Checked: : Date: z%smcoTawk¢,werUnLFLOOR SHOP owcswF•soleuas-mma«wwewrcca<suarcakuaoesip DESIGNPLANET Programmed by: Fuat Omarli, P.E. P1 P2 P3 INPUT 4 JOIST NO 4 J2-I)17 20.75' (2nd floor).__ SPAN Manual input governs—',,> 20.750 120.75 t * Q1 Q2 103 SLAB WIDTH r. 4.0 Ft DL+LL 5.89 k x2 f 5.89 k JOIST DEPTH 12" DL+Wind 3.24 k 3.24 k Uniform Point, Loads Applied at top Dist. From left support SERVICE DEAD LOAD 65 78 Psf, P1: SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (901T. ANGLES) Fc' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD A, q'd= Max(Tu/0.9*Fy AND. Tu/0.75*Fu ) As ( 2L s ) Ito] all: IfWAD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length III Plf Point Loads Applied at bott. Dist. From left support 312 Plf Q1: I 50 Ksi Q2: i--- 3 Ksi Q3: • I 29157 Ft-Lbs 20582 Lbs 0.457 in2 OK 2L-1x1x1/8 As=0.46 . n2 NONE i 5893 Lbs 3237 Lbs END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 4.92 k / 0.578 = As=F/ 12x(0.60 fv11= I 8.52 k 4.26 / 36.0 = MAX. QTY MARK DEPTH BASE ' 4 J2-D17 20.75'(2nd floor). j 17 in 20.8 Ft 5893 Lbs 19.04 in 7 ' F(wind case)= 0.12 in2 2.70 k 10.58 = 4.68 k (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING Vs 2L-1xlx1/8 NONE (2) 1/2 3/4" 1 5/8" 5/8", *) Use the same up to the centedne,` /L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH SP J1 D17 = GIRDER JOIST le: J1D17 ie: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) 1. AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, JOIST CALC 5 of 13 OF .rwel3200 BURRIS ROAD AERIAL PRECAST CONCRETE JENSEN BEACH FL 11/1/04 UPDATE DAVIE, FLORIDA 33314 e srRucruRALsrEEL T 954-321-0200 • F 954-321-0093 (2ND FLOOR Design: T.D.Y. Dale: 08121l19 Checked: Date: Z%ShapDr—plAERIAL FLOOR SHOP OWGSIAFQ0191 05•Mud. R.id—.IAPC Cal.W.sl Qa If5 SPXD1711.R(2M rw).&IG-4 Dag" nFSIGNPI ANFT Pmarammed bv: Fuat Omadi. P.E. P1 P2 P3 INPUT JOIST NO 5 SPJ1-D1711.0' (2nd floor SPAN Manual input governs—> 11.000 Ill t ♦ Q1 Q2 Q3 t SLAB WIDTH 4.0 Ft DL+LL 4.18 k x2 4.18 k JOIST DEPTH 17- . DL+Wind 2.77 k 2.77 k Uniform Point Loads A_p_plie_d_ at top Dist. From left support SERVICE DEAD LOAD 105 126 Psf P1: ; SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) P3: — TOTAL LOAD=DL+LL 760 Pif Point Loads Applied at bott. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) ! 504 Plf 01: .: F Y (BOTi. ANGLES) 50 Ksi Q2: --.----� FG' 3 Ksi Q3: ; DESIGN OF BOTTOM CHORD ;.' '@ MIDSPAN MAX. MOMENT 10653 Ft-Lbs TENSION AT BOTTOM CHORD 7520 Lbs A,,�q.d = Max(Tu/0.9*Fy AND Tu/0.75*Fu) - 0.167 in2 OK As ( 21-'s ) ( I zL-iXixi/s---As=G.46 — -- � n2 TOP CHORD I NONE ---------- --- DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) 4180 Lbs REACTION (DL+Wind) 2772 Lbs LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) 4180 Lbs Diagonal Length 19.04 in END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 2.88 k / 0.578 = 4.99 k As=F/ 120.60 fv11= 2.49 / 36.0 = MAX' QTY MARK DEPTH BASE 5 SPJ1-D1711.0' 29d floor). 17 in I 11.0 Ft F(wind case)= 1.91 k / 0.58 = 3.31 k 0.07 in2 (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING Vs 2L-1xlx118 NONE 1 (2); 1/2 5l8" 1/2" *) Use the same up to the centedne,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1D17 SP J1 DI = GIRDER JOIST ie: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) 0 AERIAL PRECAST CONCRETE AERIAL PRECAST CONCRETE, LLC 3200 BURRIS ROAD DAVIE, FLORIDA 33314 ! LOT 5 DIAMONDS SANDS, JENSEN BEACH, FL JOIST CALC 6 of 1111104 13 UPDATE Design: T.D.Y. Date: 08/21/19 T954-321-0200 • F 954-321-0093 (2ND FLOOR) Checked: Date: Z%Sh0P DrabpIAERIAL FLOOR SHOP OWGS%F-20101L0t5-wanda Raid—e'APC CaksU0kl Cakg6 SPJ2-D17 WS'(2W Dore AslGraviy Design DESIGNPLANET Programmed by: Fuat Omadi, P.E. P, P2 P3 INPUT i JOIST NO 6 SPJ2-D1716.75' (2nd-floor). SPAN Manual input governs—> 16.750 ' 16.75 'rt ♦ Q, Q2 Q3 t SLAB WIDTH 4.0 Ft DL+LL 6.37 k x2 6.37 k JOIST DEPTH 17" • DL+Wind 4.22.k 4.22 k Uniform Point Loads Applied at top Dist. From left support r— SERVICE DEAD LOAD 105 126 Psf Pj: SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) P3: ; TOTAL LOAD=DL+LL 760 Plf Point Loads Applied at bott. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) 504 Plf Qj: ; F y (BOTi. ANGLES) 50 Ksi Q2: FC 3 Ks! Q3: ' DESIGN OF BOTTOM CHORD Y' ,, @ MIDSPAN MAX. MOMENT 25207 Ft-Lbs TENSION AT BOTTOM CHORD 17793 Lbs As,.q•d= Max(Tu/0.9*FyAND Tu/0.75*Fu) 0.395 in2 OK As ( 21-'s) zL-lxlxl/s — — — As=o.46 =_n2 TOP CHORD [NONE - -------------..--- - DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 5.07 k / 0.578 = 8.77 k As=F/ (20.60 f0I = 4.38 / 36.0 = MAX. QTY MARK DEPTH BASE 6 SPJ2-D1716.75' 2nd floor)., 17 in 1 16.8 Ft 6365 Lbs 4221 Lbs VV LYV 19.04 in F(wind case)= 3.36 k / 0.58 = 5.81 k 0.12 in2 (2) 112 T BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING V's 2L-1xlx1/8 NONE 1 (2) 1/2 3/4" 5/8" 1/2" *) Use the same up to the centerine,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NO./ JOIST DEPTH ie: J1 D17 SP J1 D17 = GIRDER JOIST ie: SPJ1 D11(SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC /-PC LOT 5 DIAMONDS SANDS, JOIST CALL 7 Of 13 3200 BURRIS ROAD AERIAL PRECAST CONCRETE JENSEN BEACH, FL 11/1/04 UPDATE DAVIE, FLORIDA 33314 Design: T.D.Y. Date: 08/21119 a STRUCTURALSTEEL A T 954-321-0200 • F 954-321-0093 (2ND FLOOR) I � Checked: Date: z1snaFN—plAERIALFLOOR SHOP oWWff-zmeuas-M:1"mR aaacc�sUastMWSw:-0n20.75'thAH,M.Asp yD«i DESIGNPLANET Programmed by: Fuat Omadi, P.E. P1 P2 P3 INPUT i JOIST NO 7 SPJ2-D17 20.75' (grid floor . SPAN Manual input governs-,> 20.750 20.75 7 t '� Q1 Q2 Q3 1 SLAB WIDTH 4.0 Ft DL+LL 7.89 k x2 7.89 k JOIST DEPTH _ 17" DL+Wind 5.23 k 5.23 k Uniform Point Loads Applied at top Dist. From left support SERVICE DEAD LOAD 105 126 Psf Pj: SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (BOTT. ANGLES) F' J DESIGN, OF BOTTOM CHORD i MAX. MOMENT TENSION AT BOTTOM CHORD AS req'd = Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) 760 Pif Point Loads Applied at bott. Dist. From left support 504 Plf Qj:_ 50 Ksi Q2: 3 Ksi Q3: a :�@ MIDSPAN / 39013 Ft-Lbs 27539 Lbs 0.612 1n2 OK 2L-1.5 X 1.5 X 1/8 As=0.71 -- — T n2 TOP CHORD I NONE DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) 7885 Lbs REACTION (DL+Wind) 5229 Lbs LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) 7885 Lbs Diagonal Length 19.04 in END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 6.59 k / 0.578 = 11.40 k F(wind case)= As=F/ f2x(0.60 fv)) = 5.70 / 36.0 = 0.16 in2 QTY MARK DEPTH MAX. BASE 7 SPJ2-D17 20.75' 2nd floor)., 17 in 1 20.8 Ft IV 4.37 k 10.58 = 7.56 k (2) 112 - cIL BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING VS 2L-•L5 x 1.5 x 1/8 ' NONE (2)', 1/2 3/4" 3l4" 5/8" *) Use the same up to the centedne,'/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 DI = JOIST NOJ JOIST DEPTH SP J1 D17 = GIRDER JOIST ie: J1D17 le: SPJ1D11 (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, JOIST CALC 6 of 13 /-PC 3200 BURRIS ROAD 1 11/1/04 UPDATE kERIA.L PRECAST CONCRETE JENSEN BEACH FL e srRucruFuu STEEL DAVIE, FLORIDA 33314 ' Design: T.D.Y. Date: 08/21/19 T 954-321.0200 • F 954-321-0093 (3RD FLOOR) Checked: Date: 'ZAShap Drax XAERIAL FL00R SH0P DWGSIAF-2019LLa15-MhWa RmWmce1APC CeksUdst CekipA-DI78.26 ryd ffw).dsroaw yDes n DESIGNPLANET Programmed by: Fuat Omadi, P.E. P7 P2 P3 INPUT JOIST NO 8 J1 -DI 7 6.25' (3rd floor►___.., SPAN Manual input governs--> 6.250 6.25 'W It ♦ Q, Q2 Q3 t SLAB WIDTH 4.0 Ft DL+LL 1.78 k x2 1.78 k JOIST DEPTH 17- - DL+Wind 0.98 k 0.98 k Uniform Point Loads _Applied at top Dist. From left support SERVICE DEAD LOAD 65 78 Psf Pj: .: SERVICE LIVE LOAD 40 64 Psf P2: : WIND LOAD(gross Uplift) P3: TOTAL LOAD=DL+LL 568 Plf Point Loads Applied at bolt. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) 312 Plf Qj: Fy IBM. ANGLES) 50 KSI Q2: DESIGN OF BOTTOM CHORD MAX. MOMENT 2749 Ft-Lbs TENSION AT BOTTOM CHORD 1941 Lbs , ASfe,fd= Max(Tu/0.9*Fy AND Tu/0.75*Fu) 0.043 in2 OK As ( 2L'S) 2L-lxlxl/8 As=0.46 --- n2 TOP CHORD I NONE DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) _ 1775 Lbs REACTION (DL+Wind) 975 Lbs LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) 1775 Lbs P Diagonal Length 19.04 in END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 0.80 k / 0.578 = 1.39 k As=F/ [2x(0.60 f0l = 0.70 / 36.0 = QTY MARK DEPTH MAX. BASE 8 J1-D17 6.25' 3rd floor). 17 in 1 6.3 Ft F(wind case)= 0.44 k / 0.58 = 0.76 k 0.02 in2 (2) 1/2 Y BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING V's 2L-lxlxl/8 NONE (2) 1/2 1/2" *) Use the same up to the centedne,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH SP J1 D17 = GIRDER JOIST ie: A D17 ie: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) i AERIAL PRECAST CONCRETE, LLC 3200 BURRIS ROAD AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 i a STRUCTURAL STEEL— T 954-321-0200 • F 954.321-0093 LOT 5 DIAMONDS SANDS, JENSEN BEACH, FL (3RD FLOOR) JOIST CALC 9 of 13 1111104 UPDATE Design: T.D.Y. Date: 08/21/19 Checked: Date: 2:IShap DMMngS'AERIAL FLOOR SHOP DWGSIAF.201SU5-MhWa Resides OPC CatsUasl CakgBJIVI 14.15(3rd Aw).xls"ty Design DESIGNPLANET Programmed by: Fuat Omani, P.E. Pf P2 P3 INPUT JOIST NO 9 J1-D;1714.75' (3rd floor)_, _, SPAN Manual input governs—? 14.750 ' 14.75 • t * QI Q2 Q3 SLAB WIDTH _ 4.0 Ft DL+LL 4.19 k x2 f 4.19 k JOIST DEPTH 17" w DL+Wind 2.30 k 2.30 k Uniform Point Loads Applied at top Dist. From left support SERVICE DEAD LOAD 65 78 Psf PI: SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (1307. ANGLES) Fc;' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD AS req'd = Max(Tu/0.9*Fy AN D-Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WES DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length P3. 568 Pif Point Loads Applied at bolt. Dist. From left support 312 Plf Qj: 50 Ksi Q2: _ 3 Ksi Q3: ' ,y„@rINIDSPAN 14618 Ft-Lbs 10319 Lbs 0.229 in2 OK 2L-lxlxl/8 As=0.46 n2 n NONE 4189 Lbs 2301 Lbs 4189 Lbs 19.04 in END DIAGONAL Tension bar a. = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 3.22 k / 0.578 = 5.57 k As=F/ f2x(0.60 fv)1= 2.78 / 36.0 = QTY MARK DEPTH MAX. BASE 9 J1-D1714.75'(3rd floor). 17 in 1 14.8 Ft F(wind case)= 1.77 k / 0.58 = 3.06 k 0.08 in2 (2) 1/2 T BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 I REMAING V's 2L-1xlxv8 NONE 1 (2) 1/2 5/8" 1/2" * } Use the same up to the centerine,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: - N/G= Not Good J1 D17 = JOIST NO./ JOIST DEPTH ie: J1 D17 SP J1 D17 = GIRDER JOIST ie: SPJ1 D11(SP INDICATES SPECIAL JOIST) L AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, JOIST CALL 10 of 13 PC 3200 BURRIS ROAD 1111104 UPDATE AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 JENSEN BEACH, FL Design: T.D.Y. Date: 08/21/19 �e sTRU(TURALSTEEL I T 954-321-0200 • F 954-321.0093 (3RD FLOOR) Checked: Date: ZLShcp DmsinpIAERIAL FLOOR SHOP MOAF-20191otS- Miaada Resideme1AP0C*5WoistC*q10 ZD1720.25(9rd 0oar).tlslGrev6y D.n UESIUNF'LANIL I Nrogrammea Dy: Fuat urnanl, v.t. P, P2 P3 INPUT i �, 4 JOIST NO 10 J2•12117 20.25' (3rd floor). SPAN Manual input governs--> 20.250 2a25 - t * Q, Qz Q3 ? SLAB WIDTH 4.0 Ft DL+LL 5.75 k ` x2 5.75 k JOIST DEPTH 17" - DL+Wind 3.16 k 3.16 k Uniform Point Loads Applied at to Dist. From left support SERVICE DEAD LOAD 65 78 Psf P{ SERVICE LIVE LOAD 40 64 Psf P2: WIND LOAD(gross. Uplift) P3: TOTAL LOAD=DL+LL 568 Plf Point Loads Applied at bott. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) 312 Plf Q{ 7 F y (BOTT. ANGLES) 50 Ks! Q2: _ ' Fc' j 3 Ksi Q3: ! ' DESIGN OF BOTTOM CHORD , @ MIDSPAN MAX. MOMENT TENSION AT BOTTOM CHORD As req'd = Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length 27868 Ft-Lbs 19671 Lbs 0.437 in2 OK 2L-1x1x1/8 As=0.46 n2 rNONE ----- � i END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 4.78 k / 0.578 = 8.27 k As=F/ 12x(0.60 fv)l = 4.14 / 36.0 = MAX. QTY MARK DEPTH BASE 10 J2-D17 20.25' 3rd floor). 17 in 20.3 Ft 5751 Lbs 3159 Lbs 19.04 in F(wind case)= 2.63 k % 0.58 = 4.54 k 0.11 in2 (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 ' V4 V5 V6 REMAING V's 2L-lxlxl/8 NONE (2) 1/2 3/4" 5/8" 1/2" - *) Use the same up to the centedne,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH SP J1 D17 = GIRDER JOIST ie: J1D17 ie: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) L AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, JOIST CALC 11 of 13 !r� 3200 BURRIS ROAD PRECAST CONCRETE JENSEN BEACH, FL 11/1/04 UPDATI .ERIAL DAVIE, FLORIDA 33314 T 954-321-0200 • F 954.321-0093 (3RD FLOOR) Design: T.D.Y. Date: 08/21/19 Checked: Date: t1SheP Dra4V%AER1AL FLOOR SHOP DWG=F-201911ot 5. Wanda RmidmelAPC Cekribisl Ca411 J3-D1721.75(9d ftwodslGreviy Dno UtSwNrLANtI rrogrammea Dy: r-uat umanl, r.t. P1 P2 P3 INPUT i JOIST NO 11 J3-D17 21.75' (3rd floor)___-. SPAN Manual input governs—> 21.750 ' 217s V t * Q, Q2, Q3 t SLAB WIDTH 4.0 Ft DL+LL 6.18 k x2 6.18 k JOIST DEPTH 17" . DL+Wind 3.39 k 3.39 k j Uniform Point Loads Applied at top Dist. From left support SERVICE DEAD LOAD 65 78 Psf Pj: SERVICE LIVE LOAD 40 64 Psf P2: • WIND LOAD(gross Uplift) P3: I TOTAL LOAD=DL+LL 568 Plf Point Loads Applied at bolt. Dist. From left support TOTAL LOAD=DL-WL( Negative=Net Uplift) 312 Plf Qj: Fy (BOTT. ANGLES) 50 Ksi Q2: Fc' 3 Ksi Q3: DESIGN OF BOTTOM CHORD :. '@'MIDSPANs MAX. MOMENT 31871 Ft-Lbs TENSION AT BOTTOM CHORD 22497 Lbs A., Max(Tu/0.9*Fy AND Tu/0.75*Fu) 0.500 in2 OK As ( 2L's) 2L-1.5 X 1.5 X 1/8 —--As=0.71 -----� n2 TOP CHORD NorvE DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) 6177 Lbs REACTION (DL+Wind) 3393 Lbs LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) i 6177 Lbs Diagonal Length 19.04 in END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 5.21 k / 0.578 = 9.01 k As=F/ 120.60 fv)1= 4.50 / 36.0 = MAX. QTY MARK DEPTH BASE 11 J3-D17 21.75' 3rd floor). 17 in 1 21.8 Ft F(wind case)= 2.86 k / 0.58 = 4.95 k 0.13 in2 (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V7 V2 V3 V4 V5 V6 REMAING VS 21--1.5 X 1.5 X 118 NONE 1 (2) 1/2 3/4" 1 5/8" 5/8" 1/2" *) Use the same up to the centerine,`'/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NO./ JOIST DEPTH ie: A D17 SP J1 D17 = GIRDER JOIST le: SPA D1 i (SP INDICATES SPECIAL JOIST) JOIST CALC 12 Of 13 AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS, lvvoa UPDATE /�PIC 3200 BURROS ROAD JENSEN BEACH FL AERIAL PRECAST CONCRETE DAME, FLORIDA 33314 a 512ucruRA M'l I T 954-321-0200 • F 954-321-0093 ; (3RD FLOOR) Design: T.D.Y. Date: 08/21/19 Checked: Date: 7 %Shap Dm ig0AERIAL FLOOR SHOP OWGSIAF-20191Lat 5 -Wanda ResidewelAPC CaksUoist Cate SPAZ1711.0' (3N noa).x6JGrevny Design NPLANET Programmed by: Fuat Omarli, P.E. P, P2 P3 INPUT JOIST NO 12 SPJ1i D1711.0' (3rd, floor). _ SPAN Manual input governs—> 11.000 ill t ♦ Q, Q2 93 f SLAB WIDTH 4.0 Ft DL+LL 4.18 k x2 4.18 k JOIST DEPTH 17" - DL+Wind 2.77 k 2.77 k Uniform Point Loads A_Dplied at top Dist. From left support SERVICE DEAD LOAD 105 126 Psf PI: w SERVICE LIVE LOAD 40 64 Psf P2: j— WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (9017. ANGLES) Fc' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD Asreq'd= Max(Tu/0.9*FyAND 'Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar a = arctan(d/ 24")=.35.31 F=(R-Vo)/sin a= . 2.88 k / 0.578 = As=F/ 12x(0.60 fv)1= P3: . 760 Plf Point Loads Applied at bolt. Dist. From left support 504 Plf Qj: 50 Ksi Q2: C 3 Ksi Q3: �- MODS i 10653 Ft-Lbs 7520 Lbs 0.167 in2 OK r2L-lxlxl/s As=OA6 n2 NONE 4.99 k 2.49 / 36.0 = , QTY MARK DEPTH BASE 12 SPA-D1711.0' (3rd floor).! 17 in 11.0 Ft 4180 Lbs 2772 Lbs 19.04 in F(wind case)= 0.07 in2 1.91 k /0.58= 3.31 k (2) 112 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING VS2L-1x1x1/9 NONE (2) 1/2 . 5/8" 1/2" *) Use the same up to the centedne,' /L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good AD17 = JOIST NOJ JOIST DEPTH SP AD17 = GIRDER JOIST ie: J1D17 ie: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC LOT 5 DIAMONDS SANDS JOIST CALC 13 of 13 /-P 3200 BURRIS ROAD 11/1/04 UPDATE AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 JENSEN_BEACH, FL _STRUCTURALSTEEL T 954.321-0200 • F 954-321-0093 (3RD FLOOR) Design: T.D.Y. Date: 08/21/19 & Checked• Date: 71ShaP DrrI&WIAERIAL FLOOR SHOP DYM%F-2019%d5-Miinda ResidencelAPC CeksVoisl Cekg13 SPJ2-D1720.75' (3rd IWor).ilsj raft Design INPUT JOIST NO 13 SPJ2-D17 20.75' (3rd flo_ o),._ SPAN Manual input govems--> 20.750 20.75 'w t SLAB WIDTH _ 4.0 Ft JOIST DEPTH 17" V Uniform SERVICE DEAD LOAD 105 126 Psf SERVICE LIVE LOAD 40 64 Psf WIND LOAD(gross Uplift) DESIGNPLANET Programmed by: Fuat Omadi, P.E. P1 P2 P3 l 1 l Q1 Q2 Q3 DL+LL 7.89 k x2 t 7.89 k DL+Wind 5.23 k 5.23 k Point Loads Applied at top Dist. From left support P2: P3: TOTAL LOAD=DL+LL 760 Plf, Point Loads Applied at bolt. Dist. From left support TOTAL LOAD=DL-WL( Negative =Net Uplift) 504 Plf Q1: Fy (607. ANGLES) 50 KSI Q2: r Fc- 3 Ksi' Q3: DESIGN OF BOTTOM CHORD @ MIDSPAN I - MAX. MOMENT TENSION AT BOTTOM CHORD As req'd = Max(Tu/0.9*Fy AND Tu10.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar 39013 Ft-Lbs 27539 Lbs 0.612 in2 OK zL-is x is x its AS=o.n — n2 NONE T a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 6.59 k / 0.578 = 11.40 k As=F/ 12x(0.60 fv)1= 5.70 / 36.0 = MAX. QTY MARK DEPTH BASE 13 SPJ2-D17 20.75' (3rd floor). 17 in 20.8 Ft 7885 Lbs 5229 Lbs I OOU LU.J 19.04 in F(wind case)= 4.37 k / 0.58 = 7.56 k 0.16 in2 (2) 1/2 C/L BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING Vs 2L-1.5 X 1.5 X 1/8 NONE (2) 1/2 314" 3/4" 5/8" *) Use the same up to the centedne,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST N0./ JOIST DEPTH SP J1 D17 = GIRDER JOIST ie: J1D17 ie: SPA D1 i (SP INDICATES SPECIAL JOIST) Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copvdght ENERCALC. INC. 1983-2019, Build: 10.19.1.27' . 1 DESCRIPTIO B-1 CODE REFERENCES Calculations perAISC 360-10, IBC 2015; CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7716 Material Properties Analysis MethoAllowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling . E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending 0(39.287) L(22.156) D(0.1 ..-D(0.65�_IJOA) a- ---a 3) L(0.08) W 14x82 Span = 14.50 ft [� I Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.670, L = 0.410 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.130, L = 0.080 k/ft, Extent = 0.0 --» 8.50 ft, Tributary,Width = 1.0 ft Uniform Load : D = 0.650, L = 0.40 k/ft, Extent = 8.50 --» 14.50 ft, Tributary Width = 1.0 ft Point Load : D = 39.287, L = 22.156 k @ 7.750 ft DESIGN SUMMARY ° .. _.__...__ .. Maximum Bending Stress Ratio - 0.766: 1 Maximum Shear Stress Ratio = _. _... ....... - - ... 0.321 : 1 ........ Section used for this span W14x82 Section used for this span W14x82 Ma: Applied 265.557 k-ft Va : Applied 46.784 k Mn / Omega : Allowable 346.806 k-ft Vn/Omega,: Allowable 145.860 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 7.747ft Location of maximum on span . 14.500 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.119 in Ratio = 1,465 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.329 in Ratio = 529 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 __.... ........ ... ._....... ... .... _._.._.. _ _............... .... ...c.. -. ..._._.._... Maximum Forces &Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values • Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb .Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 14.50 ft 1 0.489 0.205 169.76 169.76 579.17 346.81 1.00 1.00 29.87 218.79 145.86 +D+L+H Dsgn. L = 14.50 ft 1 0.766 0.321 265.56 265.56 579.17 346.81 1.00 1.00 46.78 218.79 145.86 +D+Lr+H Dsgn. L = 14.50 ft 1 0.489 0.205 169.76 169.76 579.17 346.81 1'.00 1.00 29.87 218.79 145.86 +D+S+H Dsgn. L = 14.50 ft 1 : 0.489 0.205 169.76 169.76 579.17 346.81 1.00 1.00 29.87 218.79 145.86 +D+0.750Lr+0.750L+H Dsgn. L = 14.50 ft 1 0.697 0.292 241.61 241.61 579.17 346.81 1.00 1.00 42.56 218.79 145.86 +D+0.750L+0:750S+H Dsgn. L = 14.50 ft 1 0.697 0.292 , •241.61 ;241.61 579.17 . 346.81 1.00 1.00 42.56 218.79 145.86 +D+0.60W+H Dsgn. L = 14.50 ft 1 0.489 0.205 169.76 169.76 579.17 346.81 1.00 1.00 29.87 218.79 145.86 +D+0.750Lr+0.450W+H Project Title: Engineer: MARIO DI PRIETO• Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-1 Load Combination Max Stress Ratios Summary of Moment Values 'Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max, VnxVnx/Omega Dsgn. L = 14.50 ft 1 0.489 0.205 169.76 169.76 579.17 346.81 1.00 1.00 29.87 218.79 145.86 +D+0.750S+0.450W+H Dsgn. L = 14.50 ft 1 0.489 0.205 169.76 169.76 579.17 346.81 1.00 1.00 29.87 218.79 145.86 +0.60D+0.60W+0.60H Dsgn. L = 14.50 ft 1 0.294 0.123 101.85 101.85 579.17 346.81 1.00 1.00 17.92 218.79 145.86 +D+0.70E+0.60H Dsgn. L = 14.50 ft 1 0.489 0.205 169.76 169.76 579.17 346.81 1.00 1.00 29.87 218.79 145.86 +D+0. 750 L+0. 750 S+0. 5250 E+H Dsgn. L = 14.50 ft 1 0.697 0.292 241.61 241.61 579.17 346.81 1.00 1.00 42.56 218.79 145.86 +0.60D+0.70E+H Dsgn. L = 14.50 ft 1 0.2941 0.123 101.85 101.85 579.17 346.81 1.00 1.00 17.92 218.79 145.86 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L+H 1 0.3290 7.416 0.0000 0.000 Vertical Reactions Support notation : Far left is #' Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 39.593 46.784 Overall MINimum 14.264 16.917 +D+H 25.329 29.867 +D+L+H 39.593 46.784 +D+Lr+H 25.329 29.867 +D+S+H 25.329 29.867 +D+0.750Lr+0.750L+H 36.027 42.555 +D+0.750L+0.750S+H 36.027 42.555 +D+0.60W+H 25.329 29.867 +D+0.750Lr+0.450W+H 25.329 29.867 +D+0.750S+0.450W+H 25.329 29.867 +0.60D+0.60W+0.60H 15.197 17.920 +D+0.70E+0.60H 25.329 29.867 +D+0.750L+0.750S+0.5250E+H 36.027 42.555 +0.60D+0.70E+H 15.197 17.920 D Only 25.329 29.867 Lr Only L Only 14.264 16.917 S Only W Only E Only H Only • f Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beare Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO 13-2 CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis MethoAllowable Strength Design Fy : Steel Yield 50.0 ksi Beam,Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending I�„ -,•. , ,,, fly. W 14x34 Span = 20.750 ft )plied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 1.340, L = 0820 k/ft, Tributary Width = 1.0 It DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Ma: Applied Mn / Omega: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection .... _..... _ ...._.. Maximum Forces & Stresses for L 0.867: 1 Maximum Shear Stress Ratio = W14x34 Section used for this span 118.082 k-ft Va : Applied 136.228 k-ft Vn/Omega : Allowable +D+L+H Load Combination 10.375ft Location of maximum on span Span # 1 Span # where maximum occurs 0.348 in Ratio= 714>=360. 0.000 in Ratio = 0 <360 0.932 in Ratio = 267 >=180 0.000 in Ratio = 0 <180 0.286 : 1 W14x34 22.763 k 79.80 k +D+L+H 0.000 ft Span # 1 Load Combination Segment Length Span # Max Stress Ratios M V Mmax + Summary oT moment values Mmax - Ma Max Mnx Mnx/Omega Cb Rm oummary of oncdi odium, Va Max VnxVnx/Omega +D+H Dsgn. L = 20.75 ft 1 0.543 0.179 73.95 73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +D+L+H Dsgn. L = 20.75 ft 1 0.867 0.285 118.08 118.08 227.50 136.23 1.00 1.00 22.76 119.70 79.80 +D+Lr+H Dsgn. L = 20.7&.ft 1 0.543 0.179 73.95 73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +D+S+H Dsgn. L = 20.75 ft 1 0.543 0.179 73.95 73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +D+0.75OLr+0.750L+H Dsgn. L = 20.75 ft 1 0.786 0.259 107.05 107.05 227.50 136.23 1.00 1.00 20.64 119.70 79.80 +D+0.750L+0.750S+H Dsgn. L = 20.75 ft 1 0.786, 0.259 107.05 107.05 227.50 136.23 1.00 1.00 20.64 119.70 79.80 +D+0.60W+H Dsgn. L = 20.75 ft 1 0.543 0.179 73.95 73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +D+0.75OLr+0.450W+H Dsgn. L = 20.75 ft 1 0.543 0.179 73.95 73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +D+0.750S+0.450W+H Dsgn. L = 20.75 ft 1 0.543 0.179 73.95 73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +0.60D+0.60W+0.60H Dsgn. L = 2015 ft 1 0.326, 0.107 44.37 44.37 227.50 136.23 1.00 1.00 8.55 119.70 79.80 +D+0.70E+0.60H Dsgn. L = 20.75 ft 1 0.543' 0.179 73.95 •73.95 227.50 136.23 1.00 1.00 14.26 119.70 79.80 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 20.75 ft 1 0.786' I 0.259 107.05 107.05 227.50 , 136.23 1.00 1.00 20.64 119.70 79.80 Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build: 10.19.1.27 . �.� DESCRIPTIO B-2 �.� Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M I V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +0.60D+0.70E+H I - Dsgn. L = 20.75 ft 1 0.326 •0.107 44.37 44.37 227.50 136.23 1.00 1.00 8.55 119.70 79.80 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L+H 1 0.9324 10.434 0.0000 0.000 Vertical Reactions Support notation : Far left is #, Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 22.763 22.763 Overall MINimum 8.508 8.508 +D+H 14.255 14.255 +D+L+H 22.763 22.763 +D+Lr+H 14.255 14.255 +D+S+H 14.255 14.255 +D+0.750Lr+0.750L+H . 20.636 20.636 +D+0.750L+0.750S+H 2O.636 20.636 +D+0.60W+H 14.255 14.255 +D+0.750Lr+0.450W+H 14.255 14.255 +D+0.750S+0.450W+H 14.255 14.255 +0.60D+0.60W+0.60H 8.553 8.553 +D+0.70E+0.60H 14.255 14.255 +D+0.750L+0.750S+0.5250E+H 2O.636 20.636 +0.60D+0.70E+H 8.553 8.553 D Only 14.255 14.255 Lr Only L Only 8.508 8.508 S Only W Only E Only H Only I Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beare Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-3 CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis MethoQN11owable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending D 0.22 L 0.13 _DL0.65� L 0(_.4L- 4 W 14x30 1�5 Span =16.0ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Uniform Load : D = 0.480, L = 0.290 k/ft, Extent = 0.0 --» 7.750 ft, Tributary Width = 1.0 ft Uniform Load : D = 0.220, L = 0.130 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.650, L = 0.40 k/ft, Extent = 7.750 - > 16.0 ft, Tributary Width = 1.0 ft DESIGN SUMMARY ' ' • Maximum Bending Stress Ratio = 0.353: 1 Maximum Shear Stress Ratio = 0.146 : 1 Section used for this span W14x30 Section used for this span W14x30 Ma: Applied 41.652 k-ft Va : Applied 10.914 k Mn / Omega: Allowable 118.014 k-ft Vn/Omega : Allowable 74.520 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 8.366ft Location of maximum on span 16.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.084 in Ratio = 2,289> 360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.228 in Ratio = 843 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 16.00 ft 1 0.223 0.092 26.30 26.30 197.08 118.01 1.00 1.00 6.88 111.78 74.52 +D+L+H Dsgn. L = 16.00 ft 1 0.353 0.146 41.65 41.65 197.08 118.01 1.00 1.00 10.91 111.78 74.52 +D+Lr+H Dsgn. L = 16.00 ft 1 0.223 0.092 26.30 26.30 197.08" 118.01 1.00 1.00 6.88 111.78 74.52 +D+S+H Dsgn. L = 16.00 ft 1 0.223, 0.092 26.30 26.30 197.08 118.01 1.00 1.00 6.88 111.78 74.52 +D+0.750Lr+0.750L+H Dsgn. L = 16.00 ft 1 0.320 0.133 37.82 37.82 197.08 118.01 1.00 1.00 9.91 111.78 74.52 +D+0.750L+0.750S+H Dsgn. L = 16.00 ft 1 0.320 0.133 37.82 37.82 197.08 118.01 1.00 1.00 9.91 111.78 74.52 +D+0.60W+H - Dsgn. L = 16.00 It 1 0.223 0.092 26.30 26.30 197.08 118.01 1.00 1.00 6.88 111.78 74.52 +D+0.750Lr+0.450W+H Dsgn. L = 16.00 ft 1 0.223 0.092 26.30 26.30 197.08 118.01 1.00 1.00 6.88 111.78 74.52 +D+0.750S+0.450W+H Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copvdght ENERCALC. INC. 1983-2019, Build: 10. 19.1.27 . DESCRIPTIO B-3 Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega Dsgn. L = 16.00 ft 1 0.223 0.092 26.30 26.30 197.08 118.01 1.00 1.00 6.88 111.78 74.52 +0.60D+0.60W+0.60H Dsgn. L = 16.00 ft 1 0.134 0.055 15.78 15.78 197.08 118.01 1.00 1.00 4.13 111.78 74.52 +D+0.70E+0.60H Dsgn. L = 16.00 ft 1 0.223 ' 0.092 26.30 26.30 197.08 118.01 1.00 1.00 6.88 111.78 74.52 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 16.00 ft 1 0.320 0.133 37.82 37.82 197.08 118.01 1.00 1.00 9.91 111.78 74.52 +0.60D+0.70E+H Dsgn. L = 16.00 It 1 0.134 0.055 15.78 15.78 197.08 118.01 1.00 1.00 4.13 111.78 74.52 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. °+° Defl Location in Span +D+L+H 1 0.2277 8.091 0.0000 0.000 Vertical Reactions Support notation : Far left is #, Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 9.796 10.914 Overall MINimum 3.594 4.034 +D+H 6.202 6.881 +D+L+H 9.796 10.914 +D+Lr+H 6.202 6.881 +D+S+H 6.202 6.881 +D+0.750Lr+0.750L+H 8.897 9.906 +D+0.750L+0.750S+H 8.897 9.906 +D+0.60W+H 6.202 6.881 +D+0.750Lr+0.450W+H 6.202 6.881 +D+0.750S+0.450W+H 6.202 6.881 +0.60D+0.60W+0.60H 3.721 4.129 +D+0.70E+0.60H 6.202 6.881 +D+0.750L+0.750S+0.5250E+H 8.897 9.906 +0.60D+0.70E+H 3.721 4.129 D Only 6.202 6.881 Lr Only L Only 3.594 4.034 S Only W Only E Only H Only LSteel Beam DESCRIPTIO B-4 .I CnDF RFFFRFNr-F-R Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Software copyright ENERCALC, INC. 1983-2019, Build: 10.19.1.27 . Calculations per AISC 360-10, IBC 2015,! CBC 2016, ASCE 7-10 Load Combinatio SSet : ASCE 7-16 Material Properties Analysis Methodallowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending I D(0.12) L(0.07) D(13 (8:q L -951 D(0.65 L 0.4 D(13.18jC(r38b� rrm� W 14x90 rrm� Span = 27.750 ft Applied Loads __............ ..... ...... _....... -......_ Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.670, L = 0.410 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.650, L = 0.40 k/ft, Extent = 0.0 --» 20.750 ft, Tributary Width = 1.0 ft Uniform Load : D = 0.120, L = 0.070 k/ft, Extent = 20.750 -» 27.750 ft, Tributary Width = 1.0 ft Point Load : D = 4.167, L = 2.295 k @ 1.750 ft Point Load : D = 13.180, L = 1.386 k @ 21.0 ft Point Load : D = 13.20, L = 8.80 k @ 0.250 ft DESIGN SUMMARY • - . _..._.._.. Maximum Bending Stress Ratio = .............. .... ..... _ _ ......._..--- .................. 0.686: 1 Maximum Shear Stress Ratio = 0.499 :1 Section used for this span W14x90 Section used for this span W14x90 Mai: Applied 261.789 k-ft Va : Applied 61.443 k Mnl/ Omega - Allowable 381.642 k-ft Vn/Omega.: Allowable 123.20 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 14.826ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.395 in Ratio = 842 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 1.279 in Ratio = 260 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination I Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +D+L+H Dsgn. L = 27.7 Ti 1 0.686 0.499 261.79 261.79 637.34 381.64 1.00 1.00 61.44 184.80 123.20 +D+Lr+H i Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +D+S+H 1 Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +D+0.750Lr+0.750L+H Dsgn. L = 27.75 ft 1 0.633 0.454 241.52 241.52 .637.34 381.64 1.00 1.00 55.90 184.80 123.20 Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr:MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-4 Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+0.750L+0.750S+H Dsgn. L = 27.75 ft 1 0.633 0.454 241.52 241.52 637.34 381.64 1.00 1.00 55.90 184.80 123.20 +D+0.60W+H Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +D+0.750Lr+0.450W+H Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +D+0.750S+0.450W+H Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +0.60D+0.60W+0.60H Dsgn. L =; 27.75 ft 1 0.285 0.191 108.59 108.59 637.34 381.64 1.00 1.00 23.57 184.80 123.20 +D+0.70E+0.60H - Dsgn. L = 27.75 ft 1 0.474 0.319 180.98 180.98 637.34 381.64 1.00 1.00 39.29 184.80 123.20 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 27.75 ft 1 0.633 0.454 241.52 241.52 637.34 381.64 1.00 1.00 55.90 184.80 123.20 +0.60D+0.70E+H Dsgn. L = 27.75 It 1 0.285 0.191 108.59 108.59 637.34 381.64 1.00 1.00 23.57 184.80 123.20 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+° Defl Location in Span +D+L+H 1 1.2786 14.113 0.0000 0.000 Vertical Reactions Support notation : Far left is #, Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 61.443 37.170 Overall MINimum 22.156 10.493 +D+H 39.287 26.677 +D+L+H 61.443 37.170 +D+Lr+H 39.287 26,677 +D+S+H 39.287 26.677 +D+0.750Lr+0.750L+H 55.904 34.547 +D+0.750L+0.750S+H 55.904 34.547 +D+0.60W+H 39.287 26.677 +D+0.750Lr+0.450W+H 39.287 1 26.677 +D+0.750S+0.450W+H 39.287 26.677 +0.60D+0.60W+0,60H 23.572 16.006 +D+0.70E+0.60H 39.287 26.677 +D+0.750L+0.750S+0.5250E+H 55.904 34.547 +0.60D+0.70E+H 23.572 16.006 D Only 39.287 26.677 Lr Only L Only 22.156 10.493 S Only W Only E Only H Only Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam I Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . 11 DESCRIPTIO B-5 CODE REFERENCES Calculations per AISC 360-10, IBC 2015„ CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis MethoiAllowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis : Major Axis Bending I D(0.48) L(0.43) W 14x22 Span = 17.50 ft Applied Loads Service loads enteredj. Load Factors will be applied for calculations. Beam, self weight calculated and added to loading Uniform Load : D = 0.220, L = 0.130 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.480, L = 0.430 k/ft, Extent = 0.0 - > 4.250 ft, Tributary Width = 1.0 ft DESIGN SUMMARY Maximum Bending Stress Rafio = ... 0.225: 1 Maximum ShearStress Ratio = .._ _._-. 0.106 :1 Section used for this span W14x22 Section used for this span W14x22 Ma: Applied 18.646 k-ft Va : Applied 6.653 k Mn / Omega: Allowable 82.834 k-ft Vn/Omega : Allowable 63.020 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 7.500ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.069 in Ratio = 3,025-360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.182 in Ratio = 1151 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces'Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 17.50 ft 1 0.140 0.062 11.56 11.56 138.33 82.83 1.00 1.00 3.91 94.53 63.02 +D+L+H Dsgn. L = 17.50 ft 1 0.225 0.106 18.65 18.65 138.33 82.83 1.00 1.00 6.65 94.53 63.02 +D+Lr+H Dsgn. L = 17.50 ft 1 0.140 0.062 11.56 11.56 138.33 82.83 1.00 1.00 3.91 94.53 63.02 +D+S+H Dsgn. L = 17.50 ft 1 0.140 0.062 11.56 11.56 138.33 82.83 1.00 "1.00 3.91 94.53 63.02 +D+0.750Lr+0.750L+H Dsgn. L = 17.50 ft 1 0.204 0.095 16.87 16.87 138.33 82.83 1.00 1.00 5.97 94.53 63.02 +D+0.750L+0.750S+H Dsgn. L = 17.50 ft 1 0.204 0.095 16.87 16.87 138.33 82.83 1.00 1.00 5.97 94.53 63.02 +D+0.60W+H Dsgn. L = 17.50 ft 1 0.140' 0.062 11.56 11.56 138.33 82.83 1.00 1.00 3.91 94.53 63.02 +D+0.750Lr+0.450W+H Dsgn. L = 17.50 ft 1 0.140 0.062 11.56 11.56 138.33 82.83 1.00 1.00 3.91 94.53 63.02 +D+0.750S+0.450W+H Dsgn. L = 17.50 ft 1 0.140 0.062 11.56 11.56 138.33 82.83 1.00 1.00 3.91 94.53 63.02 +0.60D+0.60W+0.60H Dsgn. L = 17.50 ft 1 0.084 0.037 6.93 6.93 138.33 .82.83 1.00 1.00 2.35 94.53 63.02 +D+0.70E+0.60H I ' • Project Title: Engineer:. MARIO DI PRIETO Project ID: APC19-097 , Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Bearn Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-5 Load Combination Max Stress Ratios Summary of'Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega Dsgn. L = 17.50 ft 1 0.140 0.062 11.56 11.56 138.33 82.83 1.00 1.00 3.91 94.53 63.02 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 17.50 ft 1 0.204 0.095 16.87 16.87 138.33 8.2.83 1.00 1.00 5.97 94.53 63.02 +0.60D+0.70E+H Dsgn. L = 17.50 ft 1 0.084 0.037 6.93 6.93 138.33 82.83 1.00 1.00 2.35 94.53 63.02 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. 'Y' Defl Location in Span +D+L+H 1 0.1824 8.500 0.0000 0.000 Vertical Reactions Support notation : Far left is #' Values in KIPS Load Combination Support 1 2 VVCldll IVIAAMIUIII U.UJJ J.f" Overall MINimum 2.346 1.359 +D+H 3.910 2.365 +D+L+H 6.653 I 3.725 +D+Lr+H 3.910 2.365 +D+S+H 3.910 ! 2.365 +D+0.750Lr+0.750L+H 5.967 3.385 +D+0.750L+0.750S+H 5.967: 3.385 +D+0.60W+H 3.910 2.365 +D+0.750Lr+0.450W+H 3.910 2.365 +D+0.750S+0.450W+H 3.910 2.365 +0.60D+6.60W+0.60H 2.346 1.419 +D+0.70E+0.60H 3.910 2.365 +D+0.750L+0.750S+0.5250E+H 5.967 3.385 +0.60D+0.70E+H 2.346 1.419 D Only 3.910 2.365 Lr Only L Only 2.743 1.359 S Only W Only E Only H Only I Steel Beam DESCRIPTIO B-6 Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE'(LOT 5) ENERCALC, INC. 1983-2019, Build:10.19.1.27 . CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Methodallowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending L0.359 ) W 14x30 'Span = 21.750 ft ... _.. ...... .... )plied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0,130, L = 0.080 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.130, L = 0.080 k/ft, Extent = 15.0 -->> 21.750 ft, Tributary Width = 1.0 ft Point Load : D = 2.365, L = 1.359 k @ 15.50 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.268: 1 Maximum Shear Stress Ratio = _• 0.087 :1 Section used for this span W14x30 Section used for this span W14x30 Ma: Applied 31.593 k-ft Va : Applied 6.461 k Mn / Omega: Allowable 118.014 k-ft Vn/Omega : Allowable 74.520 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 15.474ft Location of maximum on span 21.750 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.105 in Ratio = 2,493>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.298 in Ratio = 876 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 21.75 ft 1 0.173 0.056 20.38 20.38 197.08 118.01 1.00 1.00 4.17 111.78 74.52 +D+L+H Dsgn. L = 21.75 ft 1 0.268 0.087 31.59 31.59 197.08 118.01 1.00 1.00 6.46 111.78 74.52 +D+Lr+H Dsgn. L = 21.75 ft 1 0.173 0.056 20.38 20.38 197.08 118.01 1.00 1.00 4.17 111.78 74.52 +D+S+H Dsgn. L =. 21.75 ft 1 0.173 0.056 20.38 20.38 197.08 118.01 1.00 1.00 4.17 111.78 74.52 +D+0.750Lr+0.750L+H Dsgn. L = 21.75 ft 1 0.244 0.079 28.79 28.79 197.08 118.01 1.00 1.00 5.89 111.78 74.52 +D+0.750L+0.750S+H Dsgn. L = 21.75 ft 1 0.244 0.079 28.79 28.79 197.08 118.01 1.00 1.00 5.89 111.78 74.52 +D+0.60W+H Dsgn. L = 21.75 ft 1 0.173 0.056 20.38 20.38 . 197.08 118.01 1.00 1.00 4.17 111.78 74.52 +D+0.750Lr+0.450W+H Dsgn. L = 21.75 ft 1 0.173 0.056 20.38 20.38 197.08 118.01 1.00 1.00 4.17 111.78 74.52 +D+0.750S+0.450W+H Dsgn. L = 21.75 ft 1 0.173 , 0.056 20.38 20.38 197.08 118.01 1.00 1.00 4.17 111.78 74.52 Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build: 10.19.1.27 . DESCRIPTIO B-6 Load Combination Max Stres's Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +0.60D+0.60W+0.60H Dsgn. L = 21.75 ft 1 0.104 0.034 12.23 12.23 197.08 118.01 1.00 1.00 2.50 111.78 74.52 +D+0.70E+0.60H Dsgn. L = 21.75 ft 1 ; 0.173 0.056 20.38 20.38 197.08 118.01 1.00 1.00 4.17 111.78 74.52 +D+0.750L+0.7508+0.5250E+H Dsgn. L = 21.75 ft 1 0.244 0.079 28.79 28.79 197.08 118.01 1.00 1.00, 5.89 111.78 74.52 +0.60D+0.70E+H Dsgn. L = 21.75 ft 1 0.104 0.034 12.23 12.23 197.08 118.01 1.00 1.00 2.50 111.78 74.52 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L+H 1 0.2981 11.496 0.0000 0.000 Vertical Reactions Support notation : Far left is #, Values in KIPS Load Combination Support 1 Support 2 Overall MAXimi m 3.900 6.461 Overall MINimum 1.344 2.295 +D+H 2.556 4.167 +D+L+H 3.900 6.461 +D+Lr+H 2.556 4.167 +D+S+H 2.556 4.167 +D+0.750Lr+0.750L+H 3.564 5.888 +D+0.750L+0.750S+H 3.564 5.888 +D+0.60W+H 2.556 4.167 +D+0.750Lr+0.450W+H 2.556 4.167 +D+0.750S+0.450W+H 2.556 4.167 +0.60D+0.60W+0.60H 1.533 2.500 +D+0.70E+0.60H 2.556 4.167 +D+0.750L+0.750S+0.5250E+H 3.564 5.888 +0.60D+0.70E+H 1.533 2.500 D Only 2.556 4.167 Lr Only j L Only 1.344 2.295 S only W Only E Only H Only d � Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam DESCRIPTIO B-7 CODE REFERENCES Software INC. 1983-2019, Build:10.19.1.27 . Calculations per AISC 360-10, IBC 2015, ,CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis MethoAllowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending D(0.13) L(0.08)(3.371) L(0.35) D(3.426 tqO.2 11 D(0.13) L(0.08) W14x53 Span = 20.0 ft ... ....... )plied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.740 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.130, L = 0.080 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.130, L = 0.080 k/ft, Extent = 0.0 - > 5.250 ft, Tributary Width = 1.0 ft Uniform Load : D = 0.130, L = 0.080 k/ft, Extent = 16.250 --» 20.0 ft, Tributary Width = 1.0 ft Point Load : D = 3.126, L = 0.210 k @ 16.750 ft Point Load: D=3.371, L = 0.350 k @ 4.750 ft DESIGN SUMMARY ■ .... Maximum Bending Stress Ratio = . ....-.. 0.307: 1 Maximum Shear Stress Ratio = 0.142 : 1 Section used for this span W14x53 Section used for this span W14x53 Ma: Applied 66.678 k-ft Va : Applied 14.566 k Mn / Omega: Allowable 217.315 k-ft Vn/Omega : Allowable 102.860 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 9.600ft Location of maximumon span 20.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.029 in Ratio = 8,287>=360- Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.317 in Ratio = 757->=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +D+L+H Dsgn. L = 20.00 ft 1 0.307, 0.142 66.68 66.68 362:92 217.32 1.00 1.00 14.57 154.29 102.86 +D+Lr+H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +D+S+H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +D+0.750Lr+0.750L+H Dsgn. L = 20.00 ft 1 0.3001 0.138 65.17 65.17 362.92 217.32 1.00 1.00 14.22 154.29 102.86 Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr:MIRANDA RESIDENCE (LOT5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build: 10.19.1.27 . DESCRIPTIO 13-7 Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnxtOmega +D+0.750L+0.750S+H Dsgn. L = 20.00 ft 1 0.300 0.138 65.17 65.17 362.92 217.32 1.00 1.00 14.22 154.29 102.86 +D+0.60W+H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 `60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +D+0.750Lr+0.450W+H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +D+0.750S+0.450W+H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +0.60D+0.60W+0.60H Dsgn. L = 20.00 ft 1 0.167 0.077 36.39 36.39 362.92 217.32 1.00 1.00 7.91 154.29 102.86 +D+0.70E+0.60H Dsgn. L = 20.00 ft 1 0.279 0.128 60.65 60.65 362.92 217.32 1.00 1.00 13.18 154.29 102.86 +D+0.750 L+0.750S+0.5250 E+H Dsgn. L = 20.00 ft 1 0.300 0.138 65.17 65.17 362.92 217.32 1.00 1.00 14.22 154.29 102.86 +0.60D+0.70E+H Dsgn. L = 20.00 ft 1 0.167 0.077 36.39 36.39 362.92 217.32 1.00 1.00 7.91 154.29 102.86 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L+H 1 0.3170 9.943 0.0000 0.000 Vertical Reactions Support notation : Far left is # Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 14.441 - 14.566 Overall MINimum 1.494 1.386 +D+H 12.947 13.180 +D+L+H 14.441 14.566 +D+Lr+H 12.947 13.180 +D+S+H 12.947 13.180 +D+0.750Lr+0.750L+H 14.067 14.220 +D+0.750L+0.750S+H 14.067 14.220 +D+0.60W+H 12.947 13.180 +D+0.750Lr+0.450W+H 12.947 13.180 +D+0.750S+0.450W+H 12.947 13.180 +0.60D+0.60W+0.60H 7.768 7.908 +D+0.70E+0.60H 12.947 13.180 +D+0.750L+0.750S+0.5250E+H 14.067 14.220 +0.60D+0.70E+H 7.768 7.908 D Only 12.947 13.180 Lr Only L Only 1.494 1.386 S Only W Only E Only H Only Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beare Software copyright ENERCALC, INC. 1983-2019, Build: 10.19.1.27 . DESCRIPTIO B-8 CODE REFERENCES Calculations per.AISC 360-10. IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis MethoAllowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending 0 0.75).. a W14x43 \ j Span = 7.0 ft )plied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.10, L = 0.060 k/ft, Tributary Width = 1.0 ft Uniform Load: D = 0.750 k/ft, Tributary Width = 1.0 ft DESIGN SUMMARY s - __ _._._....__..---...--.._.. Maximum Bending Stress Ratio = _...__.._. _._....._. _.__.._......._........ 0.034: 1 Maximum Shear Stress Ratio = - -- - - _............ 0.040 :1 , . Section used for this span W14x43 Section used for'this span W14x43 Ma: Applied 5.837 k-ft Va : Applied 3.336 k Mn / Omega: Allowable 173.653 k-ft Vn/Omega : Allowable 83.570 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 3.500ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.000 in Ratio = 0 <360 - Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.004 in Ratio = 20159 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 7.00 ft 1 0.031 0.037 5.47 5.47 290.00 173.65 1.00 1.00 .3.13 125.36 83.57 +D+L+H Dsgn. L = 7.00 ft 1 0.034 0.040 5.84 5.84 290.00 173.65 1.00 1.00 3.34 125.36 83.57 +D+Lr+H Dsgn. L = 7.00 ft 1 0.031 0.037 5.47 5.47 290.00 173.65 1.00 1.00 3.13 125.36 83.57 +D+S+H Dsgn. L = 7.00 ft 1 0.031 0.037 5.47 5.47 290.00 173.65 1.00 1.00 3.13 125.36 83.57 +D+0.750Lr+0.760L+H Dsgn. L = 7.00 ft 1 0.033 0.039 5.75 5.75 290.00 173.65 1.00 1.00 3.28 125.36 83.57 +D+0.750L+0.750S+H Dsgn. L = 7.00 ft 1 0.033 0.039 5.75 5.75 290.00 173.65 1.00 1.00 3.28 125.36 83.57 +D+0.60W+H Dsgn. L = 7.00 ft 1 0.031. 0.037 5.47 5.47 290.00 173.65 1.00 1.00 3.13 125.36 83.57 +D+0.750Lr+0.450W+H Dsgn. L = 7.00 ft 1 0.031 0.037 5.47 5.47 290.00 173.65 1.00 1.00 3.13 125.36 83.57 +D+0.750S+0.450W+H Dsgn. L = 7.00 ft 1 0.031 0.037 5.47 5.47 290.00 173.65 1.00 1.00 3.13 125.36 83.57 +0.60D+0.60W+0.60H Dsgn. L = 7.00 ft 1 0.019 0.022 3.28 3.28 29.0.00 173.65 1.00 1.00 1.88 125.36 83.57 +D+0.70E+0.60H Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr:MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC. INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-8 Load Combination Max Stress Ratios Summary of Moment Values Summary, of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega Dsgn. L = 7.00 ft 1 0.031 0.037 5.47 5.47 290.00 173.65 1.00 1.00 3.13 125.36 83.57 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 7.00 ft 1 0.033 0.039 5.75 5.75 290.00 173.65 1.00 1.00 3.28 125.36 83.57 +0.60D+0.70E+H Dsgn. L = 7.00 ft 1 0.019 0.022 3.28 3.28 290.00 173.65 1.00 1.00 1.88 125.36 83.57 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L+H 1 0.0042 3.520 0.0000 0.000 Vertical Reactions I Support notation : Far left is #' Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 3.336 3.336 Overall MINimum 0.210 0.210 +D+H 3.126 3.126 +D+L+H 3.336 3.336 +D+Lr+H 3.126 3.126 +D+S+H 3.126 3.126 +D+0.750Lr+0.750L+H 3.283 3.283 +D+0.750L+0.750S+H 3.283 3.283 +D+0.60W+H 3.126 3.126 +D+0.750Lr+0.450W+H 3.126 3.126 +D+0.750S+0.450W+H 3.126 3.126 +0.60D+0.60W+0.60H 1.875 1.875, +D+0.70E+0.60H 3.126 3.126 +D+0750L+0.750S+0.5250E+H 3.283 3.283 +0.60D+0.70E+H 1.875 1.875 D Only 3.126 3.126 Lr Only, L Only 0.210 0.210 S Only W Only E Only H Only Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Seam Software copyright ENERCALC, INC. 1983-2019, Build: 10. 19. 1.27 . DESCRIPTIO B-9 CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Methodallowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending 1 _D(0.75_) .._._._.. .. s W 1 4x43 n Span = 7.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beare self weight calculated and added to loading Uniform Load: D = 0.170, L = 0.10 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.750 k/ft, Tributary Width = 1.0 ft DESIGN SUMMARY .... ........ -----..__...__._._..._._.-....._... .-_.--- _.._.._.... Maximum Bending Stress Ratio -- Section used for this span Ma: Applied Mn / Omega: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Maximum Forces & Stresses for Load Combination Segment Length +D+H Dsgn. L = 7.00 ft +D+L+H Dsgn. L = 7.00 ft +D+Lr+H Dsgn. L = 7.00 ft +D+S+H Dsgn. L = 7.00 ft +D+0.750Lr+0.750L+H Dsgn. L = 7.00 ft +D+0.750L+0.750S+H Dsgn. L = 7.00 ft +D+0.60W+H , Dsgn. L = 7.00 ft +D+0.750Lr+0.450W+H Dsgn. L = 7.00 ft +D+0.750S+0.450W+H Dsgn. L = 7.00 ft +0.60D+0.60W+0.60H Dsgn. L = 7.00 ft +D+0.70E+0.60H 0.037: 1 . Maximum Shear Stress Ratio = W14x43 Section used for this span 6.511 k-ft Va : Applied 173.653 k-ft Vn/Omega : Allowable +D+L+H Load Combination 3.500ft Location of maximum on span Span # 1 Span # where maximum occurs 0.000 in Ratio = 0 <360 0.000 in Ratio = 0 <360 0.005 in Ratio = 18073 >=180 0.000 in Ratio = 0 <1.80 Combinations inc Ci imm�ro of Mnmai ]esian C 0.045 :1 W14x43 3.721 k 83.570 k +D+L+H 0.000 ft Span # 1 Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega 1 0.034 0.040 5.90 5.90 290.00 173.65 1.00 1.00 3.37 125.36 83.57 1 0.037 0.045 6.51 6.51 290.00 173.651.001.00 3.72 125.36 83.57 1 0.034 0.040 5.90 5.90 290.00 173.651.001.00 3.37 125.36 83.57 1 0.034 0.040 5.90 5.90 290.00 173.651.001.00 3.37 125.36 83.57 1 0.037 0.043 6.36 6.36 290.00 173.651.001.00 3.63 125.36 83.57 1 0.037 0.043 6.36 6.36 290.00 173.651.001.00 3.63 125.36 83.57 1 0.034 0.040 5.90 5.90 290.00 1713.651.001.00 3.37 125.36 83.57 1 0.034 0.040 5.90 5.90 290.00 173.651.001.00 3.37 125.36 83.57 1 0.034 0.040 5.90 5.90 290.00 173.651.001.00 3.37 125.36 83.57 1 0.020, 0.024 3.54 3.54 290.00 173.651.001.00 2.02 125.36 83.57 i Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-9 Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx1Omega Dsgn. L = 7.00 ft 1 0.034 0.040 5.90 5.90 290.00 173.65 1.00 1.00 3.37 125.36 83.57 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 7.00 ft 1 0.037 0.043 6.36 6.36 290.00 173.65 1.00 1.00 3.63 125.36 83.57 +0.60D+0.70E+H Dsgn. L = 7.00 ft 1 0.020 0.024 3.54 3.54 290.00 173.65 1.00 1.00 2.02 125.36 83.57 Overall Maximum Deflections Load Combination Span Max.'-" Defl Location in Span Load Combination Max. 'W' Defl Location. in Span +D+L+H 1 0.0046 3.520 0.0000 0.000 Vertical Reactions Support notation : Far left is #' Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 3.721 3.721 Overall MINimum 0.350 0.350 +D+H 3.371 3.371 +D+L+H 3.721 3.721 +D+Lr+H 3.371 3.371 +D+S+H 3.371 3.371 +D+0.750Lr+0.750L+H 3.633 3.633 +D+0.750L+0.750S+H 3.633 3.633 +D+0.60W+H 3.371 3.371 +D+0.750Lr+0.450W+H 3.371 3.371 +D+0.750S+0.450W+H 3.371 3.371 +0.60D+0.60W+0.60H 2.022 2.022 +D+0.70E+0.60H 3.371 3.371 +D+0.750L+0.750S+0.5250E+H 3.633 3.633 +0.60D+0.70E+H 2.022 2.022 D Only 3.371 3.371 Lr Only L Only 0.350 0.350 S Only W Only E Only H Only Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software Lic # : KVI]'06011297; copyright ENERCALC, INC. 1983-2019, Build: 10.19.1.27 "L14eq!"e ; Aerial P.iecast Concretetl•C, KwW0'14R2 'i DESCRIPTIO B-10 CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis MethoAllowable Strength Design Fy : Steel Yield 50.0 ksi Beam Bracing Beam is Fully Braced against lateral -torsional buckling E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending U U. I-q L U. 1 D 0.64 ,L(0.39) ` ` W14x43 ��) 7iy-r, 4A Span = 14.750 ft JJ i f l Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to -loading Uniform Load : D = 0.540, L = 0.330 k/ft, Tributary Width = 1.0 ft Uniform Load : D = 0.640, L = 0.390 k/ft, Extent = 0.0 - > 7.750 ft, Tributary Width = 1.0 ft Uniform Load : D = 0.170, L = 0.10 k/ft, Extent = 7.750 - > 14.750 ft, Tributary Width = 1.0 ft Uniform Load D = 0.750 k/ft, Tributary Width = 1.0 ft Point.Load : D = 12.947, L = 1.494 k @ 7.750 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.670: 1 Maximum Shear Stress Ratio = 0.305 :1 Section used for this span W14x43 Section used for this span W14x43 Ma: Applied 116.335 k-ft Va : Applied 25.452 k Mn / Omega: Allowable 173.653 k-ft Vn/Omega : Allowable 83.570 k Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span 7.754ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection - Max Downward Transient Deflection 0.065 in Ratio = 2,743 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.337 in Ratio = 526 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega +D+H Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 83.57 +D+L+H Dsgn. L = 14.75 ft 1 0.670 0.305 116.34 116.34 290.00 173.65 1.00 1.00 25.45 125.36 83.57 +D+Lr+H Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 83.57 +D+S+H Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 83.57 +D+0.750Lr+0.750L+H , Dsgn. L = 14.75 ft 1 0.639 0.288 111.01 111.01 290.00 173.65 1.00 1.00 24.07 125.36 83.57 +D+0.750L+0.750S+H Dsgn. L = 14.75 ft 1 0.639 0.288 111.01 111.01 290.00 173.65 1.00 1.00 24.07 125.36 83.57 +D+0.60W+H Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Beam Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO B-10 Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 83.57 +D+0.750Lr+0.450W+H Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 83.57 +D+0.750S+0.450W+H Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 .83.57 +0.60D+0.60W+0.60H Dsgn. L = 14.75 ft 1 0.328 0.143 57.03 57.03 290.00 173.65 1.00 1.00 11.95 125.36 83.57 +D+0.70E+0.60H Dsgn. L = 14.75 ft 1 0.547 0.238 95.05 95.05 290.00 173.65 1.00 1.00 19.91 125.36 83.57 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 14.75 ft 1 0.639 0.288 111.01 111.01 290.00 173.65 1.00 1.00 24.07 125.36 83.57 +0.60D+0.70E+H Dsgn. L = 14.75 ft 1 0.328 0.143 57.03 57.03 290.00 173.65 1.00 1.00 11.95 125.36 83.57 Overall Maximum Deflections Load Combination Span , Max. "" Defl Location in Span Load Combination Max. °+° Defl Location in Span +D+L+H 1 0.3365 7.375 0.0000 0.000 Vertical Reactions Support notation : Far left is # Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 25.452 23.391 Overall MINimum 5.537 4.547 +D+FI 19.915 18.844 +D+L+H 25.452 23.391 +D+Lr+H 19.915 18.844 +D+S+H 19.915 18.844 +D+0.750Lr+0.750L+H 24.068 22.254 +D+0.750L+0.750S+H 24.068 22.254 +D+0.60W+H 19.915 18.844 +D+0.750Lr+0.450W+H 19.915 18.844 +D+0.750S+0.450W+H 19.915 18.844 +0.60D+0.60W+0.60H 11.949 11.307 +D+0.70E+0.60H 19.915 18.844 +D+0.750L+0.750S+0.5250E+H 24.068 22.254 +0.60D+0.70E+H 11.949 11.307 D Only 19.915 18.844 Lr Only L Only 5.537 4.547 S Only W Only E Only H Only Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Column Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . I, DESCRIPTIO SC1 Code References Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: ASCE 7-16 General Information Steel Section Name: HSS6x4x1/2 Overall Column Height 13.0 ft Analysis Method : Allowable Strength Top & Bottom Fixity. Top & Bottom Pinned Steel Stress Grade A500GradeCFy=.50ksiCarbonSteel Brace condition for deflection (buckling) along columns Fy : Steel Yield n 50.0 ksi X-X (width) axis: E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y-Y Axis = 13.0 ft, K = 1.0 Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 13.0 ft, K = 1.0 Applied Loads S6rvice loads entered. Load Factors will be applied for calculations. AXIAL LOADS... Axial Load at 13.0 ft, D = 39.287, L = 22.156 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.6743 : 1 Maximum Load Reactions . . Load Combination +D+L+H Top along X-X 0.0 k Location of max.above base 0.0 ft Bottom along X-X 0.0 k At maximum location values are ... Top along Y-Y 0.0 k Pa: Axial 61.443 k Bottom along Y-Y 0.0 k Pn / Omega: Allowably 106.985 k Ma-x :Applied , 0.0 k-ft Maximum Load Deflections ... Mn-x / Omega: Allowable 36.427 k-ft Along Y-Y 0.0 in at for load 'combination O.Oft above base Ma-y : Applied 0.0 k-ft Mn-y / Omega: Allowable 27.445 k-ft Along X-X 0.0 in at O.Oft above base for load combination PASS Maximum Shear Stress Ratii 0.0 : 1 Load Combination Location of max.above base 0.0 ft At maximum location values are ... Va : Applied 0.0 k Vn / Omega: Allowable 0.0 k ` Load Combination Results Maximum Axial + Bendino Stress Ratios Maximum Shear Ratios Load Combination Stress RatioStatus Location Cbx Cby <xLx/Rx <yLy/Ry Stress RatidStatus Location +D+H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+L+H 0.574 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+Lr+H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+S+H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.750Lr+0.750L+H 0.523 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.750L+0.750S+H 0.523 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.60W+H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.750Lr+0.450W+H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.750S+0.450W+H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +0.60D+0.60W+0.60H 0.220 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.70E+0.60H 0.367 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +D+0.750L+0.750S+0.525 0.523 PASS 0.00 ft 1.00 1.00 75.00 104.00 0.000 PASS 0.00 ft +0.60D+0.70E+H 0.220 PASS 0.00 ft 1.00 1.00 75.00 ,104.00 0.000 PASS 0.00 ft Maximum Reactions I Note: Only non -zero reactions are listed. Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top +D+H 39.287 +D+L+H 61.443 +D+Lr+H 39.287 A- , Project Title: Engineer: MARIO 01 PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) Steel Column Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.27 . DESCRIPTIO SC1 Maximum Reactions Note: Only non -zero reactions are listed. Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top +D+0.750Lr+0.750L+H 55.904 +D+0.750L+0.750S+H 55.904 +D+0.60W+H 39.287 +D+0.750Lr+0.450W+H 39.287 +D+0.750S+0.450W+H. 39.287 +0.60D+0.60W+0.60H 23.572 +D+0.70E+0.60H 39.287 +D+0.750L+0.750S+0.5250E+H 55.904 „ +0.60D+0.70E+H 23.572 D Only 39.287 Lr Only i L Only 22.156 S Only W Only E Only H Only Extreme Reactions Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction, Mx - End Moments k-ft My - End Moments Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top Axial @ Base Maximum 61.443 Minimum Reaction, X-X Axis Base Maximum 39.287 " Minimum 39.287 Reaction, Y-Y Axis Base Maximum 39.287 " Minimum 39.287 Reaction, X-X Axis Top Maximum 39.287 " Minimum 39.287 Reaction, Y-Y Axis Top Maximum 39.287 " Minimum 39.287 Moment, X-X Axis Base Maximum 39.287 " `.Minimum 39.287 Moment, Y-Y Axis Base ' Maximum 39.287 Minimum 30.287 Moment, X-X Axis Top Maximum 39.287 " Minimum 39.287 Moment, Y-Y Axis Top Maximum 39.287 " Minimum 39.287 I _ Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection +D+H 0.0000 in 0.000 ft 0.000 in +D+L+H 0.0000 in 0.000 ft 0.000 in +D+Lr+H 0.0000 in 0.000 ft 0.000 in +D+S+H 0.0000 in 0.000 ft 0.000 in +D+0.750Lr+0.750L+H 0.0000 in 0.000 ft 0.000 in +D+0.750L+0.750S+H 0.0000 in 0.000 ft 0:000 in +D+0.60W+H 0.0000 in 0.000 ft 0.000 in +D+0.750Lr+0.450W+H 0.0000 in 0.000 ft 0.000 in ' +D+0.750S+0.450W+H 0.0000 in 0.000 ft 0.000 in +0.60D+0.60W+0.60H 0.0000 in 0.000 ft 0.000 in +D+0.70E+0.60H 0.0000 in 0.000 ft 0.000 in +D+0.750L+0.750S+0.5250E+H 0.0000 in 0.000 ft 0.000 in +0.60D+0.70E+H 0.0000 in 0.000 ft 0.000 in D Only 0.0000 in 0.000 ft 0.000. in Lr Only 0.0000 in 0.000 ft 0.000 in L Only 0.0000 in 0.000 ft 0.000 in S Only 0.0000 in 0.000 ft 0.000 in Distance 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 A 0.000 ft 0.000 ft . p Project Title: Engineer: MARIO DI PRIETO Project ID: APC19-097 Project Descr: MIRANDA RESIDENCE (LOT 5) LSteel Column Software copyright ENERCALC,INC. 1983-2019,Build:10.19.1.27 . DESCRIPTIO SC1 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance W Only 0.0000 in 0.000 ft 0.000 in 0.000 ft E Only 0.0000 in 0.000 ft 0.000 in 0.000 ft H Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Steel Section Properties : HSS6z4xl/2 Depth = 6.000 in I xx = 34.00 in^4 J = 40.300 in^4 Design Thick = 0.465 in S xx = 11.30 in"3 Cw = 17.80 inA6 Width = 4.000 in R xx = 2.080 in Wall Thick = 0.500 in Zx = 14.600 inA3 Area = 7.880 inA2 1 yy = 17.800 inA4 C = 17.800 in^3 Weight = 28.430 plf S yy = 8.890 inA3 R yy = 1.500 in Zy = 11.000 in^3 Ycg = 0.000 in Sketches +Y 6t.JJJk .i el JJ]4 I J, I +X l i I I �f i I t f i S .�. y � "�,% }ate/--� i A' � ! F � P • s � [.'�° � �� i rtt i sa ..:: � .�Fi br�P'n, - - /l-`� : � • r(r/ � _I( f i' �� �d� f..��/ :� � e� 1�� I ~ AQ ° / � -----'--- - --------- -'-- / 14-1 - - --`- - `--- --'- -----`---- - � -^� ~ -�~7^ --^^-' ------~~ ----- ---------- Al ~ ^~___-- --------_ .. ' (~ - - - `-- l� -- - - - ^ - -7- ----- ^--`^--~~~'-~-^-~-'- -- ---' ~'---_- -- - _ _--- 1Z