Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
KSM PILE INSTALLATION INSPECTION
� � e u' OIL & '' U KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P 0. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772)'589-6469 September 9, 2019 ` RECErv61).----_ Joseph Miranda 9224 ,Bay Drive SEP j 6 po,g Surfside, FL 33154 sr. Lucie Count Y, Permitting I Re: Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project#: 193472-pile Dear Mr. Miranda: As requested, we werei present during the installation of the ninety-eight (98) auger -cast -piles for the ;above referenced site. Pile layout by others. The pile installation inspection was generally performed in accordance to the "Inspector Guide to the Auger Cast -In -Place Files", published by the Auger Cast -In -Place Pile Committee of The Deep Foundation Institute. Based on this inspection, it is our professional opinion, that the piles constructed for the referenced project were installed as specified 'on the construction drawings. The pile documentation and Location Plan are attached. We are pleased to be of assistance to you on this phase of your project. If you hayp•onygtnAtions, please feel free to contact the office. I - lop �� opt .••G�� Ernaii:to: jmirandaCjfminc.biz : Ronald G. Keller, P E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 Walks KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND .TESTING, INC. MARTIN (772) 337-7755 RO. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 C.A.: 5693 FAX (56845-8876 8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27; 2019 Pile Pile Pile Pile Pump Truck No. Time Location Diameter Length Reinforcement Strokes Installed (See Location Plan August 26, 2019 1 16" 25' (6) #6 Vertical 24' Bars 16 25316 9:33 w/ #3 Ties @ 12" o.c. to 20' 2 16 25316 9:44 3 " 16 25316 9:53 4 17 25316 10:00 5 17 25316 10:07 6 Is, if16 25316/71287 10:13 7 16 25316/71287 10:21 8 " " 17 71287 10:29 9 " 17 71287 10:36 10 18 71287 10:44 11 18 71287 10:56 12 18 71287/67685 11:05 ,13 17 67685 11:11 14 16 67685 11:18 15 19 67685 11:28 16 19 67685 11:36 17 Is It. 18 67685/64624 11:43 18 " 18 64624 11:50 19 " 20 " is it 18 64624 12:02 21 "9119 17 64624 12:09 22 "19 is 64624 12:19 18 64624 12:32 23 19 71287 12:45 24 17 71287 1:02 25 18 71287 1:16 26 18 71287 1:28 27 _ 18 71287' 1:42 28 17 71287/67685 1:51 29 " __ 81 17 67685 2:00 30 18 67685 2:08 31 17 67685 2:16 32 17 67685 2:24 Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 0 I, J A KELLER,f SCHLEICHER &'Mac1NILLIAM ENGINEERING AND TESTING, INC. MARTIN ACC 561) 855 PO, BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (876 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (569 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE 72) 229-9093 C.A.: 5693 (7 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Pile Pile Pile Location Diameter Length (See Location Plan Date Installed: August 26 and 27, Pile Pump Truck No. Reinforcement Strokes 2019 Time Installed August 26, 201.9 33 16" 25' (6) #6 Vertical 24' Bars 20 67685/64624 2:32 w/ #3 Ties @ 12" o.c. to. 20' 34 _ 35 19 64624 2:44 36 ,� 18 64624 2:54 37 16 64624 3:04 38 " " 17 64624 3:10 39 18 64624 3:20 40 " 18 71287 3:31 41 17 71287 3:40 i 42 19 71'7 3:49 43 E 17 71287 3:57 44 if 17 71287 4:05 45 it , 20 71287 4:13 -; 46 „ f —_„ 17 67685 4:24 _ 47 1-- — It 18 67685 4*31 48 " {I _ I, 17 67685 4:38 49 99'1 19 67685 4:47 50 " -� it 17 67685 454 Au ust 27, 2019 20 1 67685 5,05 51 161, 25' (6) #6 vertical 24' Bars 17 25756 8:40 w/ #3 Ties @ 12" o.c. to 20' 52 is « 53 •, 17 25756 8:50 54 « « 21 25756 9.-08 55 if - 19 25756 9:14 56 21 18 25756 9:29 57 it 64624 9:37 58 18 64624 9:46 59 „ — ,� J __ �� 22 64624 9:55 -�--_ 6a it, 19 64624 10: 04 61 18 64624 10:13 - °� -- 62 �� --__ ___.. - 23 — 64624 10:48 --- " 22 64623 10:58 Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 TAP OIL ff KELLER, SCHLEICHER &.MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 - PO.BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 C.A.: 5693 FAX (56845-8876 E-Mail: KSM@KSMENGINEERING.NET . ST. LUCIE (772) 229-9093 FAX (772) 589-6469 Pile Installation Inspections 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27, 2019 Pile I Pile PII6 Location Diameter Length (See Location —Pan) August 27, 2019 -� 63 1 16" 25, _ 64 65 66 67 68 69 70 71 73 74 75 76 77 78 79 80 81 82 83 84 Pile Reinforcement (6) #6 Vertical 24' Bars w/ #3 Ties ct 12" o.c. to 20' Pump I Truck No. Time Strokes Installed 18. 1 ' 64623 18 i 64623 20 64623 18 64623 19 3 64624 18 ; 64624 18 64624 18 ! 64624 21 64624 18 26433 19 i 26433 20. 20 _26433 26433 20 26433 _ 19 26433 21 25756 _22 —.21 25756 25756 19 25756 21 25756 18 66455 _ .20 66455 20 66455 — 19 66455 - 18. 66455 19 �21, 66455 26433 20 '26433 _ 19 26433 18 26433, 18 1 26433 21 J 25756 Julie E. Keller, P.E.: 68366 11:12 11:22 11:34 12:35 12:47 12:53 1:04 1:13 1:30 1:41 1:53 1:59 2:08 2:15. 2:30 2:42 2:49 2:57 3:08 3:27 3:37 3:43 3:52 4:07 4:18 4:28 4:37 4:46 4:55 5:06 5:18 5:26 Ronald G. Keller, P.E.: 37293 / SI Lic..No.: 860 / Up ILAr KELLER, SCHLEICHER & MaCWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 PO, BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 FAX (56www.ksmengineering.net MELBOURNE (321) 768-8488 C.A.: 5693 845-8876 E-Mail: KSMQKSMENGINEERING.NET ST. LUCIE (772) 229-9093 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27, 2019 Pile Pile Pile Pile Pump Truck No. Time Location Diameter Length Reinforcement Strokes (See Installed Location - Plan Au ust 27, 2019 95 16" 25' (6) #6 Vertical 24' Bars 17 25756 5:33 w/ #3 Ties @ 12 o.c. 96 to 20' 97 21 25756 5:42 98 19 25756 5:53 20 25756 6:05 Notes: 1. Grout Strength 28 Days Compressive Strength — 5,000 PSI 2. 1 Pump Stroke = 2.35 cu. ft. of Grout Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 683,66 f I I I r LOCATION OF AUGER PILES - POOL/SPA PROJECT. Miranda Residence, 7916 S. Ocean Drive, Jensen Beach, Florida SHEET 2 OF 2 PERMIT #: PROJECT #: I93472-2 � . A-:n TCt'Til DRAWNBY.• J.L. DESIGNED BY.•J., DATE: 20190001 SCALE. NONE