HomeMy WebLinkAboutFlood Elevation-CorrectedSERVICES
BUILDING
11113 ►/_ _ •
2300 VIRGINIA AVENUE I FORT PIERCE. FL 34982 1 072) 462-1960 1 TDD (772) 462-1428 I WWW.SI'LUCIECO.GOV
Memo of EC Review for Correctness and Completion
The attached FEMA Elevation Certificate for the following address has been reviewed by this office.
8549 COBBLESTONE DR LOT 89
(1611-0004)
The items noted below are not correct on the attached form and should read as entered on this page.
SECTION A - PROPERTY INFORMATION I For Insurance Company Use: I
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number
City
State ZIP Code
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
A4.
Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.)
A5.
Latitude/Longitude: Lat. Long. Horizontal Datum:
NAD 1927
NAD 1983
A6.
Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT
Building Diagram Number: 18
A8.
For a building with a crawlspace or enclosure(s):
A9.
For a building with an attached garage:
a) Square footage of crawlspace or enclosure(s) sq fl
a)
Square footage of attached garage sq it
b) No. of permanent flood openings in the crawlspace or
b)
No. of permanent flood openings in the attached garage
enclosure(s) within 1.0 foot above adjacent grade
within 1.0 foot above adjacent grade
c) Total net area of flood openings in A8.b sq in
c)
Total net area of flood openings in A9.b sq in
d) Engineered flood openings? Yes No
d)
Engineered flood openings? Yes No
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
Bt. NFIP Community Name & Community Number B2. County Name B3. State
94. Map/Panel Number
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s) (Zone
Date
Ef(ective/Revised Date
Zone(s)
AO, use base flood depth)
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9.
x FIS FIRM Community Determined Other (Describe)
B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 NAVD 1988 Other (Describe)
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes No
Designation Date CBRS OPA
Local Official's Name: Leslie Olson, AICP Title: Director, Planning and Development Services
Community Name: St. Lucie County (Unincorporated Areas) Telephone: 772-462-1960
Date: 10/01/2019
SURVEY DATA NEEDED: 2 story; C2.b Is not N/A, QUESTIONS TO ANSWER: 2 story
house/C2.b req
CRS 310 FEN" EC CORUMON MEMO ST. LU C I E
U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008
Federal Emergency Management Agency Expiration Date: November 30, 2018
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number:
1. Lee Jeffry Abbott (CT Job # 15-141)
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number.
Box No.
8549 COBBLESTONE DRIVE
City State ZIP Code
FORT PIERCE Florida 34945
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
2326-600-0094-0004 Lot 89
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitudes Lat. 27°24372' N Long.80`24"38.0" W Horizontal Datum: ❑ NAD 1927 NAD 1983
A& Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT Building Diagram Number 1A
A8. For a building with a crawlspace or enciosure(s):
a) Square footage of crawlspace or enclosure(s) N/A sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade NIA
c) Total net area of flood openings in A8.b N/A sq in
d) Engineered flood openings? ❑ Yes ❑x No
A9. For a building with an attached garage:
a) Square footage of attached garage 400.00 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A9.b N/A sq in
d) Engineered flood openings? ❑ Yes F No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. Stale
St. Lucre County 120285
Saint Lucie
Florida
B4. Map/Panel
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s)
Number
Date
Effective/
Zone(s)
(Zone AO, use Base Flood Depth)
Revised Date
1211IC0170
J
02-16-2012
02-16-2012
AE
16.5
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9:
❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No
Designation Date: ❑ CBRS ❑ OPA
FEMA Forth 086-0-33 (7/15) Replaces all previous editions. Forth Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date. November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number
8549 COBBLESTONE DRIVE
City State ZIP Code
Company NAIC Number
FORT PIERCE Florida 34945
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction` ❑x Finished Construction
'A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, ARIAH, AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters.
Benchmark Utilized: AF6653 Vertical Datum: NAVD 88
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor)
17.23 ❑x feet ❑ meters
b) Top of the next higher floor
28.85 ❑ feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only)
N/A ❑ feet ❑ meters
d) Attached garage (top of slab)
16.57 ❑x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building
17.06 ❑ feet ❑ meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG)
16.50 ❑x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG)
16.80 ❑x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including
N/A ❑ feet ❑ meters
structural support
SECTION D— SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No
❑ Check here if attachments.
Certifiers Name License Number
Digitally
Thomas P. Kiernan 6199
r', signed by
Title
Professional Surveyor
-^""Pk"•••., Thmmas P
.:_.. Ki rnan
M4 �~9i`• IL:1y
ty;; 0 i r;
s �" '='DD�te:
TZ0.09.25
�`'
Company Name
Culpepper & Terpening. Inc.
Address
..
2980 South 25th Street
r
�>y r,W,.•
•/:' 14:16:54
City State ZIP Code
Fort Pierce Florida 34981
;".,,t'-04'00'
Signature /J /�. Date Telephone
irr�• 09-25-2020
Ext
(772) 464-3537
206
206
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance
agent/company, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
C2. e) AC Pad is Lowest equipment servicing building
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
8549 COBBLESTONE DRIVE
City State ZIP Code
Company NAIC Number
FORT PIERCE Florida 34935
SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request,
complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only,
enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below
the highest adjacent grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions),
the next higher floor (elevation C2.b in
the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E4. Top of platform of machinery and/or equipment
servicing the building is ❑ feet []meters ❑ above or ❑ below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or
community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
8549 COBBLESTONE DRIVE
City State ZIP Code
Company NAIC Number
FORT PIERCE Florida 34935
SECTION G — COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B. C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement
used in Items G8—G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE)
or Zone AO.
G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as -built lowest floor (including basement)
❑ feet ❑ meters
of the building: Datum
G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum
G10. Community's design flood elevation: ❑ feet ❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments (including type of equipment and location, per C2(e), if applicable)
❑ Check here if attachments.
FEMA Form 086-0-33 (7115) Replaces all previous editions. Form Page 4 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
8549 COBBLESTONE DRIVE
City State ZIP Code
Company NAIC Number
FORT PIERCE Florida 34935
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View"; and, if required, 'Right Side View" and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
Y ts, Y
4
a �r
A,
i �IyF
Photo One
Photo One Caption Front 10/25/2017
l'i e4r Photo OneIN
all
EL■
AN. O
Photo Two
Photo Two Caption Back 10/25/2017 Clear photo Two
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
8549 COBBLESTONE DRIVE
City
State ZIP Code
Company NAIC Number
FORT PIERCE
Florida 34935
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and "Rear View";
and, if required, 'Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative
examples of the flood openings or vents, as indicated in Section A8.
h^\
i
y
+yv:
b
4�
"1
i
p 4 i
i t
Photo Three
Photo Three Caption Right Side 10/25/2017
Clear Photo Three
t
U
'6Y
_
Photo Four
Photo Four Caption Left Side 10/25/2017
Clear Photo Four
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6
i
COBBLESTONE DRIVE
N83'26'16"E 241.70a N83'26'16 E 0' (BB)
—TO P.C. N 50„ VATH R/W^
BENCHMANK
TOP SAN. MH SS-11
AT LOT 99
_ ELEV.=17.12
N83-26'16"E 58.06'
TO P.T.-
2' CONIC. CURB 'a
SET 5/8" IR/C LB 4286 I rMi ['lIN
I �I SE
R W ?:' 4 CONC:'WALK N
o N 3-26'16"E 65.10' I
FLOOD ZONE 1 c 16 00
I
"AE-16.5' SANITARY SERVICE
_..,I _�j CONCRETEIN
I--/ '.:_r}� DRIVEWAYr
FLOOD] Y l.•f
n
ZONE "X"
LOT 90
CREEKSIDE PLAT NO.1
P.B. 55 PG. 12 O
O
OCCUPIED o
0
`;,� •eSETi5/8" IR/C LB 4286---]
T '/ 0/ / 7
THOMAS P. KIERNAN DATE
Professional Surveyor & Mapper
Florida Certificate No. 6199
19.00' GOYERED
—' PORCH
/z
LOT 89
2 STORY CBS RESIDENCE
iM EL�4EJB/C
t� F.E.=18.70 (N.G.V.D.) o
F.E.,=17.23 (N.A.V.D.)
S
1
f
COVERED
LANAI ... --.r
1.40
39.6
2.74--
CONC.
28.20'
11
d au
PADI
10.00'
LJ
5/8" IR/C LB 4286
R/W — — —
FLOOD
WATER SERVICE �^'�"-',
ZONE
LOT 88
CREEKSIDE PLAT NO.1
P.B. 55 PG. 12
UNDER
CONSTRUCTION
5/8" IR/C LB 4286
N83'26'16"E 65.10'
20' W.M.M.E.
W.M.T. 1
CERTIFIED TO:
1. Lee Jeffry Abbott
2. D.R. Horton, Inc.
3. DHI Mortgage Company, Ltd.
4. Alliant National Title Insurance Co.
REVISED FEMA LINE & VERTICAL DATUM NO 08-23-2017
GRAPHIC SCALE
20 0 10 20
11
IN FEET )
I inch a 20 It
LEGAL DESCRIPTION
BEING ALL OF LOT 89, ACCORDING TO CREEKSIDE PLAT NO. 1,
AS RECORDED IN PLAT BOOK 55, PAGE 12 PUBLIC RECORDS
OF ST. LUCIE COUNTY, FLORIDA.
CONTAINS 0.194 ACRE, MORE OR LESS.
PROPERTY ADDRESS
8549 COBBLESTONE DRIVE, FORT PIERCE
LEGEND & ABBREVIATIONS
BM
DENOTES BENCHMARK
IF
BB
DENOTES BEARING BASE
O.R.
DENOTES OFFICIAL RECORDS BOOK
C.M.
DENOTES CONCRETE MONUMENT
P.B.
DENOTES PLAT BOOK
CONC
DENOTES CONCRETE
PG.
DENOTES PAGE
C.B.
DENOTES CATCH BASIN
P.U.E.
DENOTES PRIVATE UTILITY EASEMENT
CBS
DENOTES CONCRETE BLOCK STRUCTURE
P.D.E.
DENOTES PRIVATE DRAINAGE EASEMENT
CD
DENOTES CHORD DISTANCE
P.S.M.
DENOTES PROFESSIONAL SURVEYOR & MAPPER
CB
DENOTES CHORD BEARING
P.LS.
DENOTES PROFESSIONAL LAND SURVEYOR
C/O
DENOTES CLEAN OUTS
P.C.C.
DENOTES POINT OF COMPOUND CURVATURE
rL
DENOTES CENTER UNE
P.D.
DENOTES POINT OF CURVATURE
D.E.
DENOTES DRAINAGE EASEMENT
P.E.
DENOTES POINT OF TANGENCY
F.F.E.
DENOTES FINISH FLOOR ELEVATION
(P)
DENOTES PLAT DATA
FND
DENOTES FOUND
P.C.P.
DENOTES PERMANENT CONTROL POINT
I.Q.
DENOTES IRRIGATION QUALITY WATER
R
DENOTES RADIUS
IR/C
DENOTES IRON ROD AND CAP
R/W
DENOTES RIGHT OF WAY
LB.
DENOTES LICENSED BUSINESS
SAN.
DENOTES SANITARY
L
DENOTES ARC LENGTH
U.E.
DENOTES UTILITY EASEMENT
L.M.E.
DENOTES LAKE MANAGEMENT EASEMENT
W.M.T.
DENOTES WATER MANAGEMENT TRACT
(M)
DENOTES MEASURED DATA
MAG/D DENOTES SET MAG NAIL AND DISK
M.H.
DENOTES MANHOLE
WMME
DENOTES WATER MAINTENANCE MANAGEMENT EASEMENT
N/D
DENOTES NAIL AND DISK
A
DENOTES INCLUDED ANGLE
(NR)
DENOTES NON RADIAL LINE
—�Ir�
DENOTES DRAINAGE FLOW
O.S.T.
DENOTES OPEN SPACE TRACT
N.G.V.D.
DENOTES NATIONAL GEODETIC VERTICAL DATUM
65
N.A.V.D.
DENOTES NORTH AMERICA VERTICAL DATUM
DENOTES PROPOSED ELEVATION
GENERAL NOTES
1. The last date of field work was 06-30-17
2. Additions or deletions to survey maps or reports by other than the signing party or
parties is prohibited without written consent of the signing party or parties.
3. Reproductions of this map are not valid without the signature and original raised seal of a
Florida Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights —of —way, easements
of record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This
Information should be obtained through appropriate title verification.
5. All above ground fixed improvements, if any, have been located and shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.5, according to
the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February
16, 2012. The exact designation can only be determined by an elevation certificate. No
additional search of the public records has been preformed. There may be additional map
Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and
the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the
center line of Cobblestone which bears North 83'26'16" East and all bearings
are relative thereto.
10. Elevations shown hereon are based on the National Geodetic Vertical Datum (N.G.V.D.)
1929.
11. The building setbacks shown hereon, although based on the best available information, are
not certified to and must be verified prior to design or construction.