Loading...
HomeMy WebLinkAboutFlood Elevation-CorrectedSERVICES BUILDING 11113 ►/_ _ • 2300 VIRGINIA AVENUE I FORT PIERCE. FL 34982 1 072) 462-1960 1 TDD (772) 462-1428 I WWW.SI'LUCIECO.GOV Memo of EC Review for Correctness and Completion The attached FEMA Elevation Certificate for the following address has been reviewed by this office. 8549 COBBLESTONE DR LOT 89 (1611-0004) The items noted below are not correct on the attached form and should read as entered on this page. SECTION A - PROPERTY INFORMATION I For Insurance Company Use: I A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number City State ZIP Code A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) A5. Latitude/Longitude: Lat. Long. Horizontal Datum: NAD 1927 NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number: 18 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) sq fl a) Square footage of attached garage sq it b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage enclosure(s) within 1.0 foot above adjacent grade within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in d) Engineered flood openings? Yes No d) Engineered flood openings? Yes No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Bt. NFIP Community Name & Community Number B2. County Name B3. State 94. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Ef(ective/Revised Date Zone(s) AO, use base flood depth) B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. x FIS FIRM Community Determined Other (Describe) B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 NAVD 1988 Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes No Designation Date CBRS OPA Local Official's Name: Leslie Olson, AICP Title: Director, Planning and Development Services Community Name: St. Lucie County (Unincorporated Areas) Telephone: 772-462-1960 Date: 10/01/2019 SURVEY DATA NEEDED: 2 story; C2.b Is not N/A, QUESTIONS TO ANSWER: 2 story house/C2.b req CRS 310 FEN" EC CORUMON MEMO ST. LU C I E U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: 1. Lee Jeffry Abbott (CT Job # 15-141) A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number. Box No. 8549 COBBLESTONE DRIVE City State ZIP Code FORT PIERCE Florida 34945 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) 2326-600-0094-0004 Lot 89 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitudes Lat. 27°24372' N Long.80`24"38.0" W Horizontal Datum: ❑ NAD 1927 NAD 1983 A& Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 1A A8. For a building with a crawlspace or enciosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade NIA c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑ Yes ❑x No A9. For a building with an attached garage: a) Square footage of attached garage 400.00 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes F No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. Stale St. Lucre County 120285 Saint Lucie Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 1211IC0170 J 02-16-2012 02-16-2012 AE 16.5 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Forth 086-0-33 (7/15) Replaces all previous editions. Forth Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date. November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 8549 COBBLESTONE DRIVE City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction` ❑x Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, ARIAH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: AF6653 Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 17.23 ❑x feet ❑ meters b) Top of the next higher floor 28.85 ❑ feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters d) Attached garage (top of slab) 16.57 ❑x feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 17.06 ❑ feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 16.50 ❑x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 16.80 ❑x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including N/A ❑ feet ❑ meters structural support SECTION D— SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments. Certifiers Name License Number Digitally Thomas P. Kiernan 6199 r', signed by Title Professional Surveyor -^""Pk"•••., Thmmas P .:_.. Ki rnan M4 �~9i`• IL:1y ty;; 0 i r; s �" '='DD�te: TZ0.09.25 �`' Company Name Culpepper & Terpening. Inc. Address .. 2980 South 25th Street r �>y r,W,.• •/:' 14:16:54 City State ZIP Code Fort Pierce Florida 34981 ;".,,t'-04'00' Signature /J /�. Date Telephone irr�• 09-25-2020 Ext (772) 464-3537 206 206 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) C2. e) AC Pad is Lowest equipment servicing building FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8549 COBBLESTONE DRIVE City State ZIP Code Company NAIC Number FORT PIERCE Florida 34935 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet []meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8549 COBBLESTONE DRIVE City State ZIP Code Company NAIC Number FORT PIERCE Florida 34935 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B. C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) ❑ feet ❑ meters of the building: Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (7115) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8549 COBBLESTONE DRIVE City State ZIP Code Company NAIC Number FORT PIERCE Florida 34935 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View"; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. Y ts, Y 4 a �r A, i �IyF Photo One Photo One Caption Front 10/25/2017 l'i e4r Photo OneIN all EL■ AN. O Photo Two Photo Two Caption Back 10/25/2017 Clear photo Two FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8549 COBBLESTONE DRIVE City State ZIP Code Company NAIC Number FORT PIERCE Florida 34935 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. h^\ i y +yv: b 4� "1 i p 4 i i t Photo Three Photo Three Caption Right Side 10/25/2017 Clear Photo Three t U '6Y _ Photo Four Photo Four Caption Left Side 10/25/2017 Clear Photo Four FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 i COBBLESTONE DRIVE N83'26'16"E 241.70a N83'26'16 E 0' (BB) —TO P.C. N 50„ VATH R/W^ BENCHMANK TOP SAN. MH SS-11 AT LOT 99 _ ELEV.=17.12 N83-26'16"E 58.06' TO P.T.- 2' CONIC. CURB 'a SET 5/8" IR/C LB 4286 I rMi ['lIN I �I SE R W ?:' 4 CONC:'WALK N o N 3-26'16"E 65.10' I FLOOD ZONE 1 c 16 00 I "AE-16.5' SANITARY SERVICE _..,I _�j CONCRETEIN I--/ '.:_r}� DRIVEWAYr FLOOD] Y l.•f n ZONE "X" LOT 90 CREEKSIDE PLAT NO.1 P.B. 55 PG. 12 O O OCCUPIED o 0 `;,� •eSETi5/8" IR/C LB 4286---] T '/ 0/ / 7 THOMAS P. KIERNAN DATE Professional Surveyor & Mapper Florida Certificate No. 6199 19.00' GOYERED —' PORCH /z LOT 89 2 STORY CBS RESIDENCE iM EL�4EJB/C t� F.E.=18.70 (N.G.V.D.) o F.E.,=17.23 (N.A.V.D.) S 1 f COVERED LANAI ... --.r 1.40 39.6 2.74-- CONC. 28.20' 11 d au PADI 10.00' LJ 5/8" IR/C LB 4286 R/W — — — FLOOD WATER SERVICE �^'�"-', ZONE LOT 88 CREEKSIDE PLAT NO.1 P.B. 55 PG. 12 UNDER CONSTRUCTION 5/8" IR/C LB 4286 N83'26'16"E 65.10' 20' W.M.M.E. W.M.T. 1 CERTIFIED TO: 1. Lee Jeffry Abbott 2. D.R. Horton, Inc. 3. DHI Mortgage Company, Ltd. 4. Alliant National Title Insurance Co. REVISED FEMA LINE & VERTICAL DATUM NO 08-23-2017 GRAPHIC SCALE 20 0 10 20 11 IN FEET ) I inch a 20 It LEGAL DESCRIPTION BEING ALL OF LOT 89, ACCORDING TO CREEKSIDE PLAT NO. 1, AS RECORDED IN PLAT BOOK 55, PAGE 12 PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINS 0.194 ACRE, MORE OR LESS. PROPERTY ADDRESS 8549 COBBLESTONE DRIVE, FORT PIERCE LEGEND & ABBREVIATIONS BM DENOTES BENCHMARK IF BB DENOTES BEARING BASE O.R. DENOTES OFFICIAL RECORDS BOOK C.M. DENOTES CONCRETE MONUMENT P.B. DENOTES PLAT BOOK CONC DENOTES CONCRETE PG. DENOTES PAGE C.B. DENOTES CATCH BASIN P.U.E. DENOTES PRIVATE UTILITY EASEMENT CBS DENOTES CONCRETE BLOCK STRUCTURE P.D.E. DENOTES PRIVATE DRAINAGE EASEMENT CD DENOTES CHORD DISTANCE P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER CB DENOTES CHORD BEARING P.LS. DENOTES PROFESSIONAL LAND SURVEYOR C/O DENOTES CLEAN OUTS P.C.C. DENOTES POINT OF COMPOUND CURVATURE rL DENOTES CENTER UNE P.D. DENOTES POINT OF CURVATURE D.E. DENOTES DRAINAGE EASEMENT P.E. DENOTES POINT OF TANGENCY F.F.E. DENOTES FINISH FLOOR ELEVATION (P) DENOTES PLAT DATA FND DENOTES FOUND P.C.P. DENOTES PERMANENT CONTROL POINT I.Q. DENOTES IRRIGATION QUALITY WATER R DENOTES RADIUS IR/C DENOTES IRON ROD AND CAP R/W DENOTES RIGHT OF WAY LB. DENOTES LICENSED BUSINESS SAN. DENOTES SANITARY L DENOTES ARC LENGTH U.E. DENOTES UTILITY EASEMENT L.M.E. DENOTES LAKE MANAGEMENT EASEMENT W.M.T. DENOTES WATER MANAGEMENT TRACT (M) DENOTES MEASURED DATA MAG/D DENOTES SET MAG NAIL AND DISK M.H. DENOTES MANHOLE WMME DENOTES WATER MAINTENANCE MANAGEMENT EASEMENT N/D DENOTES NAIL AND DISK A DENOTES INCLUDED ANGLE (NR) DENOTES NON RADIAL LINE —�Ir� DENOTES DRAINAGE FLOW O.S.T. DENOTES OPEN SPACE TRACT N.G.V.D. DENOTES NATIONAL GEODETIC VERTICAL DATUM 65 N.A.V.D. DENOTES NORTH AMERICA VERTICAL DATUM DENOTES PROPOSED ELEVATION GENERAL NOTES 1. The last date of field work was 06-30-17 2. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 3. Reproductions of this map are not valid without the signature and original raised seal of a Florida Licensed Surveyor and Mapper. 4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This Information should be obtained through appropriate title verification. 5. All above ground fixed improvements, if any, have been located and shown hereon. 6. Underground foundations and improvements were not located as part of this survey. 7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.5, according to the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February 16, 2012. The exact designation can only be determined by an elevation certificate. No additional search of the public records has been preformed. There may be additional map Amendments affecting this property. 8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of existing field elevation data. 9. The bearings shown hereon are based on Plat information and are referenced to the center line of Cobblestone which bears North 83'26'16" East and all bearings are relative thereto. 10. Elevations shown hereon are based on the National Geodetic Vertical Datum (N.G.V.D.) 1929. 11. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior to design or construction.