Loading...
HomeMy WebLinkAboutAPPROVED Lebron-Metal Alliance-24ga-1 inch-FL Approval.pdf 1/14/2021 Florida Building Code Online aw.e.t ProfessionalBusiness & i i;�■„ BCIS Home hog In user Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact is KIS Site Map Links 5earcn dbpr a ��Product Approval USER:Public User LrgALCt Approval Menu�Product or Annhcation Search>AQpli[ tior List>Application Detail Will FL# FL29523-R1 '`�• Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Metal Alliance Inc. Address/Phone/Email 2120 SW Poma Dr. Palm City, FL 34990 (844) 638-2548 orders@metalalliance.com Authorized Signature Tara Faulkner orders@ meta lalliance.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the David Eng Evaluation Report Florida License PE-81377 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2030 Validated By James R Wally, PE Validation Checklist- Hardcopy Received Certificate of Independence FL29523 R1 C01 32At 100SL plywood nonHVHZ.odf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 125 2003 UL580 2006 Equivalence of Product Standards Certified By Sections from the Code https:/Iwww,flodda building.org/pr/pr_app_dtl,as px?pa ra m=wG EVXQwtDq uDjJZOKCHOBeuJtRZVS4wAPLbCuLWf8sMgrM4sxtfrSA%3d%3d 113 1/14/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/11/2020 Date Validated 08/13/2020 Date Pending FBC Approval 08/19/2020 Date Approved 10/13/2020 Summary of Products FL# Model,Number or Name Description 29523.1 01: 100SL 1"Nailstrip 032 Aluminum 100SL 1"Nallstrip panel from nominal 0.032"aluminum or thicker on 15/32"(min)plywood or 3/4"(min)wood plank Limits of Use Installation Instructions Approved for use In HVHZ: No FL29523 RI II 32AI 1005L plywood nonHVHZ.{-df Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-168.5 Evaluation Reports Other: 168.5 psf @ 6"oc FL29523 RI AE 32AI 100SL plywood nonHVHZ.odf Created by Independent Third Party:Yes 29523.2 02: 100SL i"Nallstrip 24ga 1005L 1"Nailstrip panel from 24ga(min)on 15/32'(min) plywood or 3/4"(min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL29523 R3 11 24ga 100SL plywood nonHVH2 pd Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-206 Evaluation Reports Other:206 psf @ 6"oc FL29523 RI AE 24ga 100SL plywood nonHVHZ.odf Created by Independent Third Party: Yes 29523.3 03: IOOSL 1"Nailstrip 26ga HVHZ IOOSL 1"Nailstrip panel from 26ga(min)on 15/32"(min) plywood or 3/4"(min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL29523 RI Il 26ga 1005L oly±D-Q.0.pQf Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-176 Evaluation Reports Other: 176 psf @ 6"oc WITH sealant, 116 psf @ 6"oc without FL29523 R1 AE 26ga 1005L g1y-VtQDjLOAf sealant Created by Independent Third Party: Yes 29523.4 0HZ4: SOOSL 1"Nailstrip 032 Aluminum 1O05L 1"Nailstrip panel from nominal 0.032"aluminum or HV thicker on 15/32"(min)plywood or 3/4"(min)wood plank Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL29523 R1 II 32AI 1005L plywood.odf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-175 Evaluation Reports Other: 175 psf @ 6"oc WrrH sealant FL29523 Rl AE 32AI 100SL olywood.odf Created by Independent Third Party:Yes 29523.5 05: 150SL 1.5"Nailstrip 24ga 150SL 1.5'Nailstrip panel from 24ga(min)on 15/32"(min) plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use In HVHZ: No FL29523 R1 II 24ga SSOSL olvwood nonHVHZ.odf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-153.5 Evaluation Reports Other: 153.5 psf @ 6" oc WITH sealant FL29523 RI AE 24ga 1505E olvwood nonHVHZ.pdf Created by Independent Third Party:Yes 29523.6 06: 150SL 1.5" Nailstrip 032 150SL 1.5' Nailstrip panel from nominal 0.032"aluminum or Aluminum thicker on 15/32"(min) plywood or 3/4"(min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL29523 RI 11 32AI 150SL plywood nonHVHZ.odf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-168.5 Evaluation Reports Other: 168.5 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI 150SL plywood nonHVHZ.odf Created by Independent Third Party: Yes 29523.7 07: 150SL 1.5"Nailstrip 032 150SL 1.5" Nailstrip panel from nominal 0.032"aluminum or Aluminum HVHZ thicker on 15/32"(min)plywood or 3/4" (min)wood plank 1 19"coverage Limps of Use Installation Instructions https://www.floddabuilding.org/pr/pr_app_dL.aspx7param=wGEVXQwtDquDJJZOKCHOBeuJtRZVS4wAPLbCuLWf8sMgrM4sxtfrSA%3d%3d 213 1/14/2021 Florida Building Code Online I Approved for use in HVHZ:yes FL29523 R1 11 32AI 1505E pjywood.0df 1 Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-168.1 Evaluation Reports Other: 168.1 psf @ 6"oc WITH sealant FL29523 RI AE 32AI ISOSL DlywoocUsif Created by Independent Third Party:Yes 29523.8 08: ISOSL 1.5"Nailstrip 24ga HVHZ 150SL 1,5"Nailstrip panel from 24ga(min)on 15/32"(min) plywood or 314" (min)wood plank 1 19"coverage Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL29523 R1 11 24Da SSOSL Dlvwootl.0df Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-112.5 Evaluation Reports Other: 112.5 @ 6"oc WITH sealant FL29523 R1 AE 24ga 150SL 9lyw9.99.p91 Created by Independent Third Party: Yes B,.k Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:850-487-1824 The State of Florida Is an AVEEO employer.Ebavnaht 2007-2013 State of Flodaa.::Privacy Statement::Accessibility Statement::Rehmd statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response M a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant M Section 455.27S(i), Florida statutes,effective October 1,2012,licensers licensed under Uapt it 455,F.S.must provide the Department with an email address If Mey have one.The emalk provided may be used for official communication whin Me licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide Me Department with an email address which can be made avallable to the public.To determine if you are a licensee under Chapter 455.F.S.,please click here. Product Approval Accept: ® ® P Credit Card Sale httpsJ/www.floddabuilding.org/pr/pr_app_OV.aspx?pamm=wGEVXQwtDquDjJZOKCHOBeuJtRZVS4wAPLbCuLWfBsMgrM4sxtfrSA%3d%3d 3/3 METALALLIANCE A Value Added Supplier of Metals 1 " NailStrip 24ga Steel Panels 24ga ( min ) 1" Nail Strip over 15/32" ( min ) plywood Metal Alliance, Inc 2120 SW Poma Dr I Palm City FL 34990 Produced by Metal Alliance's Network of Approved Regional Manufacturers Product Description Nailstrip, snaplock style panel with a 16" maximum panel width and a nominal rib height of 1" Product Material 24ga (min) steel 24ga is nominally 0.0239" with yield strength of at least 50ksi, and shall be corrosion resistant per FBC 1507.4.3 where required. Fastener #10 1-inch pancake style fastener Compliant with FBC 1506.6 where required. Substrate/ Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 I Gainesville FL OP' or- lls, FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com No. 81377 =_ 0 STATE OF C(7411 SiOf 4' David E Eng 2020.08.10 10 0 S L 18: signed and sea This item has been digitally signed and sealed by D E Eng,PE, on the dale indicated Printed 1" NAI LSTR I P 24GA copies of this document are not considered signed and sealed and the signature must be AkL verified on any electronic copies Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: Method A: u10 x 1"_fastener at 6"_o.c. a_I.ong. nail. strip: 206 PSF A factor of safety of 2 has been applied. Fasteners are installed through the metal flange, NOT through the pre-punched slots. Technical Documentation : This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report J6368.05-450-44 RO. Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. A& METALALLIANCE A Value Added Supplier of Metals _ __ ENGINEERING LOAD TABLES Instructions: a Select the appropriate load table that applies to i .3 -- 2 2 3 the structure in question, a Determine the design wind speed for the project 2 1 1 2 location. 2 1 Use the attachment method indicated for that 2 1 2 _ 2 3 a 1 2 2 3 a windspeed within each roof zone. 1 2 NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone 2 1 1 2 concept. For the load tables below, the worst case was taken for each zone and reported using the a 3 - 2 2 _3 - a standard zones 1-2-3: 1 Zone 1 includes zones 1 and 1' oaf HIP ROOF GABLE ROOF —a-- Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r LESS IµW EIINEP I4 M lW t„(RilWIheA1EMSPIN fM Nt„I WI oD ss mIEPE"w_oe.oEzcPaP o.<n iwnn xlc cax Combining these zones creates a clear, simple ROOF ZONES FOR GENERIC BUILDING scheme, at the expense of some design efficiency. Contact Metal Alliance Inc for further information, or consult ❑ licensed design professional. METHOD A R, ONTO IAALE LEG ONTO MAIE LEG �\ AI FASTENER ALA^OC Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof,or gable/hip roof with max slope of 45e Have either a flat roof, or gable/hip roof with max slope of 45` Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL29523.02: 24 a 100SL 1" nail strip on 15/32" plywood FL29523.02: 24 a 100SL 1" nail strip on 15/32" PI wood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A Use this load table for structures which meet the following criteria. Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7e,hip roof with max slope of 45°, or gable roof with slope between 20'and 45° max slope of 45°,or gable roof with slope between 20°and 45' Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL29523.02: 24ga 100SL 1" nail strip on 15132" Plywood FL29523.02: 24 a 100SL 1" nail strip on 15/32" pIvwood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A A A& METAULLIANGE A Value Added Supplier of Metals .AWL