HomeMy WebLinkAboutFlood Elevation-Corrected'� 1� ►� I E T T DEVELOPMENT BUILDING DIVISION 2300 VIRGINIA AVENUE I FORT PIERCE, FL 349821 (772) 462—L960 I TDD t772) 462-1428 1 W W W.SIZUCIECO.GOV Memo of EC Review for Correctness and Completion The attached FEMA Elevation Certificate for the following address has been reviewed by this office. 4147 N US HWY 1 LOT 114 11604-0003) The items noted below are not correct on the attached form and should read as entered on this page. SECTION A- PROPERTY INFORMATION Fo,Onsu�ance Company Al. Building Owner's Name Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIL Number 4026 N US Hwy 1 Lot 114?? City State A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) A5. Latitude/Longitude: Lat. Long. -80"21'11.42" Horizontal Datum: NAD 1927 NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number. AS. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) sq it a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage enclosure(s) within 1.0 fool above adjacent grade within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in d) Engineered flood openings? Yes No d) Engineered flood openings? Yes No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81. NFIP Community Name & Community Number B2. County Name B3. State B4. MaplPanel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel Effective/Revised Date B8. Flood Zone(s) B9. Base Flood Elevation(s) (Zone AO, use base flood depth) B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. FIS FIRM Community Determined Other (Describe) B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 NAVO 1988 Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes No Designation Date CBRS OPA Local Official's Name: Leslie Olson, AICP Title: Director, Planning and Development Services Community Name: St. Lucie County (Unincorporated Areas) Telephone: 772-462-1960 Signature Comments: Uate: SURVEY DATA NEEDED: E1.b req , QUESTIONS TO ANSWER: A2 is site address ( PS q(1 FEMA EC CORRECTION MIMO ST. L U C I E U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE FEDERAL EMERGENCY MANAGEMENT AGENCY OMB No. 1660-0008 National Flood Imurance Program Important: Read the instructions on pages 1-9. Expiration Date: July 31, 2015 SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owners Name Country Cove MHP LLC Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number: 4147 N US Highway One, Ft Pierce, FL City Ft. Pierce State FL ZIP Code 34946 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 4147, located in Country Cove Mobile Home Park Parcel ID 1420-141-0009-000-0 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessary, etc.) Residential A5. Latitude/Longitude: Lat. 27"30'24.60' Long. 80"21'11.42' Horizontal Datum: ❑ NAD 1927 Z NAD 1983 AS. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 5 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) n/a sq ft a) Square footage of attached garage n/a sq ft b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage or enclosure(s) within 1.0 foot above adjacent grade n/a within 1.0 foot above adjacent grade Na c) Total net area of flood openings in A8.1b We sq in c) Total net area of flood openings in Ag.b nla sq in d) Engineered flood openings? ❑ Yes Z No d) Engineered flood openings? ❑ Yes Z No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State St. Lucie County 120285 St. Lucie FL B4. Map/Panel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone 12111C0088 J 2/16112 Effective/Revised Date Zone(s) AO, use base flood depth) 2/16/12 A Undetermined B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile Z FIRM ❑ Community Determined ❑ Other/Source: Bl1. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 Z NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: n/a ❑ CBRS ❑ OPA SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction' ® Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations —Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, ARM, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: CUP Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 0 Other/Source: _ Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 20.73 ® feet ❑ meters b) Top of the next higher floor N/A._ ® feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A. Z feet ❑ meters d) Attached garage (top of slab) N/A._ Z feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 2023 Z feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 15.9 Z feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 16.7 Z feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 16.3 Z feet ❑ meters SECTION D—SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify eievation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement maybe punishable by fine or imprisonment under 18 U.S. Code, Section 1001, ❑ Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a _ f - ❑ Check here if attachments. licensed land surveyor? Z Yes ❑ No o . Certfiers Name Michael T. Owen License Number LS5556 r y h � 1 S Title Vice President Company Name Engineedng Design & Construction Address 1934 Tycker urt City Ft. Pierce State FL ZIP Code 34950 Signature ate Telephone 772-419-8383`�rlrttr FEMA Form 086-0-33 (7/12) Aee reverse side for continuation. Replaces all previous editions. t LCVMI IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 4147 N US Highway One, Ft. Pierce, FL City Ft. Pierce State FL ZIP Code 34946 Company NAIC Number. SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT 13FE) For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items Et-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is 4.03 ® feet ❑ meters 0 above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is 4.83 ® feet ❑ meters 0 above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is Na. ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is n/a._ ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is 3.53 0 feet ❑ meters ® above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property, owner or owners authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owners or Owners Authorized Representative's Name Michael T. Owen Address 1934 Tun e ou City Ft. Pierce State FL ZIP Code 34950 Signature Date Telephone 772-419-8383 Comments n/a ❑ Check here if attachments. SECTION G -COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8-G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4-G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued Na n/a n/a G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: n/a._ ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: n/a. ❑ feet ❑ meters Datum G10. Community's design flood elevation: n/a. ❑ feet ❑ meters Datum Local Official's Name n/a Title n/a Community Name n/a Telephone n/a Signature n/a Date n/a Comments n/a ❑ Check here if attachments. FEMA Form 086-0-33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 4147 N US Highway One, Ft. Pierce, FL - - City Ft. Pierce State FL ZIP Code 34946 Company NAIC Number: If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings orvents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. Front View -- taken 6.25.15 Right Side View — taken 6.25.15 Rear View — taken 6.25.15 FEMA Form 086-0-33 (7/12) Replaces all previous editions. VERTICAL VINYL SKIRTING ( components S installation ) 7U F BACK jT•TACHfG will+ % 4MCH 9CR6wS 16"APART SWAPS wTp TpP SACK- 11106-9 Sc Rr-w9* AN& PANEL c".3 V6H7En PANEL-- 3.9 m4mus PER Fool SECURE& 'Ib '>aP B V EbreLA'rAnN 6CTTOM Rh1 t v� AMp i � INGN Sc-gcw5 w OCaum. 4 'i LL PANELS qR6 ^GCE Slb�f B+-E 8 W-r^dV11vG 'TbP T-1904T 4WA R "16j) UP ON PANEL A-rrAGHCo TO GRog- V.IeT" 'i"W" C=ALMJ"JItEO NAIL I9-01- (IF Sd IL IS SANDI*-T-4jEW BLOCK SUPPORT R flDS SET WIM 1M0 RET OF DID (TP) EXST GROUND LINE STEEL FRAME 17" X25" = TYPE "8" PIER ® = 1.5X3.5X6 TYPE 'A" PIER WOOD SHIMS TIE DOWN ENGINEERING SYSTEM (LONGITUDINAL AND LATERAL BRACING) INSTALLED PER MANUFACTURERS WRITTEN SPECIFICATIONS. IX8X16 cMU !. 48" GALVANIZED GROUND ANCHOR 2. MINIMUM FOUNDATION PAD FOR PIER SIZE "B" IS l7" X 25" ADS. S. ANCHOR AND STRAP REQUIRED AT FACTORY TIE DOWN LOACTIONS. FOLLOW MANUFACTURE'S INSTRCTIONS FOR TIE DOWN AND STRAPPING. 4. MIN. SOIL CAPACITY.' 1000 PSF 5. ALL EXTERIOR DOORS, BAY WINDOWS, RECESSED SIDEWALLS, AND EXTERIOR WALL OPENINGS 48" OR WIDER WILL REQUIRE BLOCKING ON EACH SIDE. ° RANDALL MERRITT PROFESSIONAL ENGINEER 97 LONNIE RAKER LANE FEv6p16 t—DPN0.E4T Y:MDA 850 25DICRAWFRDVIL 8860LE, FI 32327 MODULAR HOME PIER FOUNDATION DESIGN I certify, to the best of my knowledge, that the foundation is designed as adequately anchored to prevent flotation, collapse and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effect of buoyancy. The design has taken into account the provisions of (FBC R42/FBC 1612/ASCE 24) an the flood loads imposed by a Base Flood event of 100 year flood as shown on the current St. Lucie County Flood Insurance Rate Map. NOTE: THIS FOUNDATION HAS BEEN D I FEMA 85 GUI DELI NES FOR AL E D TIfk' FLOOD VELOCITIES UP TO 1 f FEMA FOUNDATION "` °Po CND 4147 N US 1 LOT 114 � °AGN0.