HomeMy WebLinkAboutEnergy CodeVP'ORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
RECEIVED
Project Name: Lot 20 Block 5 Waterstone 1820 DGR
Builder Name: ADAMS HOMES
FEB A 0 ,;q?'
Street: 5377 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Permitting ucf,�r4,
Owner:
Jurisdiction: 661000
`.,
St. Lucie County
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type42120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
3.' Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 270.00 ft2
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(237.2 sqft.) Description Area
•12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 18.33 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.181 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.130 Total Proposed Modified Loads: 5.9.74
PASS
Total Baseline Loads: 64.94
I hereby certify that the plans a. s cations covered b
e of the plans and
iof-tE S Afi
this calculation are in compl' c the Florida y
specifications covered by this
Code.
calculation indicates 'compliance
y ii,�`'' =
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 01-13-2021 Winn P any
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
CIO
OWNER/AC� NT: t
BUILDING OFFICIAL:
DATE: I Z
DATE:
" - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
r certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
-� envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/13/2021 11:59 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT Al IMMARY rWl:r--Wi IQT D=Dr%DT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 20 Block 5 Waterstone 18 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
20
Waterstone
5377 San Benedetto PI
St. Lucie
Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ftz ----
0.42 0 0.58
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ftz 456 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1820 ft2 0.11
80 ftz 0.11
Wood
Wood
Kj
1/13/2021 11:59 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPl1T SUMMARY rNFrKI ICT R1=an0T
F
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
1
E
Exterior
Concrete Block - Int Insul
Main
4.1 59
0
10 0
590.0 ft2
0
0 0.6
0
2
S
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0
0 0.6
0
3
W
Exterior
Concrete Block - Int Insul
Main
4.1 66
0
10 0
660.0 ft2
0
0 0.6
0
4
N
Exterior
Concrete Block - Int Insul
Main
4.1 27
0
10 0
270.0 ft2
0 0.6
0
5
-
Garage
Frame - Wood
Main
13 27
0
10 0
270.0 ft2
0
0.23 0.01
0
6
S
Exterior
Concrete Block - Int Insul
Main
4.1 7
0
10 0
70.0 ft2
0
0 0.6
0
7
N
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
S
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
2
E
1
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
S
6
Vinyl Low-E Double
Yes
0.33 0.31
N
5.0 ft2
9 ft 0 in
0 ft 6 in
None
None
4
S
2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
5
S
2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
S
6
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
9 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
7
W
3
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
N
7
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
12 ft 0 in
0 ft 6 in
Drapes/blinds
Exterior 5
9
N
4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
10
N
7
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
12 ft 0 in
0 ft 3 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49
218.7
.1381
7
1/13/2021 11:59 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT-RUMMARY rH1=c-W1 ICT R1=13nRT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V # Location R-Value Area
---- Return ----
Location Area Leakage Type
Air
Handler
CFM 25 CFM25
TOT OUT QN
RLF
HVAC #
Heat Cool
1 Attic 6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb r 1Mar
HeatinJan Feb [X] Mar
Ventin Jan Feb [[[X]]] Mar
Ceiling Fans:
Jun X Jul
f APr f May Junf Jul
A r May rl
[X] A r [ Ma Jun [ Jul
Au
f Au4
[ Aug
X Se
Sep
[ Se [X]
Oct
Oct
Oct
Nov
Nov
Nov
Dec
XDec
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8 9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
1/13/2021 11:59 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
Fr RM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
5377 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ftz
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ftz
4. Number of Bedrooms
4
d. N/A
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ftz
6. Conditioned floor area (ftz)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ftz
7. Windows- Description
Area
c. N/A
R=
ftz
a. U-Factor: Dbl, U=0.33
168.74 ftz
12. Ducts, location & insulation level
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ftz
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
18.33 ftz
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other (see details)
17.78 ftz
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.181 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft z
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1820.00 ftz
Credits (Performance method)
Pstat
b. N/A
R=
ftz
c. N/A
R=
ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ( Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/13/2021 12:00 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1