HomeMy WebLinkAboutSidewalk & Driveway DetailSIDEWALK DETAIL LD-6
2' MIN SOD • PER
0.6 TO 2% PAX
TOP OF SOD TO BE LAID
FLUSH WITH SIDEWALK
WITH 10h:1y OR FLATTER
SLOPE FOR FIRST FOOT
TYPICAL SIDEWALK
N.T.S.
2' MIN SOD
6' TYR
• 6' VlI IVUV FOR SIDEWALKS ON COLLECTOR AND ARTERIAL
ROAD AYS
5' MINIMUM FOR SIDEWALKS ON LOCAL ROADWAYS
REPLACEMENT PANEL
REPAIR OR REPLACEMENT
N.T.S.
EXPANSION JOINT
NOTES:
ALL MATERIALS AND CONSTRUCTION PROCEDURES SHALL BE IN ACCORDANCE WITH THE LATEST FDOT
INDICES AND AS FOLLOWS:
1. CONCRETE TO BE MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
2, TEST A MINIMUM OF ONE (1) COMPRESSIVE STRENGTH CYLINDER SAMPLE PER 50 CY OR ONE (1) PER LOT,
WHICHEVER IS GREATER. COMPRESSIVE STRENGTH SHALL BE REPORTED AT 28 DAYS.
3. ONLY FIBER REINFORCEMENT TO BE USED IN COUNTY RIGHT OF WAY AT A MINIMUM OF 1.5 LB/CY. STEEL
REINFORCEMENT NOT ALLOWED.
4. ALL DELETERIOUS MATERIALS TO BE REMOVED 6 INCHES BELOW BOTTOM OF SIDEWALK AND 6 INCHES
BEYOND ALL EDGES.
5, CONCRETE SHALL BE A MINIMUM OF 4 INCHES THICK FOR ALL SIDEWALKS TO BE OWNED OR
MAINTAINED BY THE COUNTY.
6. SIDEWALKS THROUGH DRIVEWAYS SHALL BE 6" THICK MINIMUM.
7. SOD TO BE LAID WITHIN THREE (3) DAYS OF FINAL GRADING IN PUBLIC RIGHT OF WAY.
8. ENTIRE SIDEWALK SLAB BETWEEN CONTRACTION/EXPANSIONS JOINTS SHALL BE RECONSTRUCTED WHEN
RESTORING EXISTING SIDEWALKS.
9. PRE -POUR INSPECTIONS ARE REQUIRED AND MUST BE ACCEPTED PRIOR TO POURING THE SIDEWALK.
10. FOR REPAIRS, REMOVE EXISTING SIDEWALK TO THE FULL WIDTH FROM CONTROL JOINT TO CONTROL
JOINT (I.E. ONE *SECTION*)
Adams Homes of Northwest Florida, Inc. Atlantic Land Designs
Adams Homes of North*est Florida, Inc. of the Treasure Coast, L87468
751 SE Port St Lucie Blyd, 754 NE Jensen Beach Blvd. Jensen Beach, FL 34957
Port St Lucie, FL 34984
(P) 772-905-8394 Mailing Address:
(F) 772-905-8511 P.O. Box 1421 Jensen Beach, FL 34958
pst*arronty®odamshomes.com ALD5543@gmail.com (772) 398-4290 SEAL
PROPERTY ADDRESS: , 77 San h p c�M `AP
gT IFIC RO
F
BP#� PSM 5543
f rr -__-- -- p OF
4�
LEGAL: LOT` BLOCK�_SUBDIVISION 57�t STAR v
FR�D < URVEy A�
DRIVEWAY DETAIL
NOT TO SCALE
D.O.T. APPROVED
3000# WITH FIBER
16'
4" THICK
4" THICK d- i 6" THICK @ DRIVEWAY
I
4" EXPANSION JOINT
I
4" THICK
6" THICK APRON
20' MAX. APRON @ ROAD
Adams Homes of Northwest Florida, Inc
Adorns Homes of North*esl Florido, Inc.
751 SE Pat St Lucie Blvd
Port St Lucie, FL 34984
(P) 772-905-8394
(F) 772-905-8511
psl*arranty®adamshomes.com
PROPERTY ADDRESS:
BP#
SIDEWALK JOINTS
Atlantic Land Designs
of the Treasure Coast, LB7468
754 NE Jensen Beach Blvd. Jensen Beach, FL 34957
Mailing Address:
P.O. Box 1421 Jensen Beach, FL 34958
ALD5543@gmail.com (772) 398-4290
SEAL
PSM 5543
I LEGAL: LOT BLOCK SUBDIVISION
STATE OF
FP1
I ."