Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 4/23/21 Permit Number: • Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT TYPE: PLUMBING PROPOSED IMPROVEMENT LOCATION: Address: 120 Blue Grotto DR Fort Pierce, FL 34945 Property Tax ID #: 2310-500-0105-000-9 Site Plan Name: Project Name: WATER HEATER DETAILED DESCRIPTION OF WORK: 55- GALLON ELECTRIC WATER HEATER REPLACEMENT CONSTRUCTION INFORMATION: Additional work to be performed under this permit — check all that apply: Lot No. Block No. _Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors _ Electric _ Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction:. Cost of Construction: $ 1650 Sq. Ft. of First Floor: Utilities: _Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Rachael Garfinkle Name: RICHARD BASSOFF Address: 120 Blue Grotto DR Company: ADMIRAL PLUMBING SERVICES, LLC City: Fort Pierce, FL 34945 State: _ Zip Code: Fax: Phone No.704-956-0920 Address: 2895 JUPITER PARK DR STE 700 City: JUPITER State: FL Zip Code: 33458 Fax: Phone No 561-746-1180 E-Mail: mommaofabh@gmail.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail PERTMITTING@THEADMIRALPLUMBER.COM State or County License CFC-1426115 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: MORTGAGE COMPANY: _ Not Applicable Name: Address: Address: City: State: Zip: Phone City: State: Zip: Phone: FEE SIMPLE TITLEHOLDER: _ Not Applicable Name: BONDING COMPANY: _Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." ell Signature of Contract r/ se Holder Signature of Owner//e4d,6 as Agent for Owner ,glContractor STATE OF FLORIDA STATE OF FLORIDA COUNTY OF PALMBFACH COUNTY OF PMAI8FACH The for Ding instr ment w s acknowledged before me this I day of r 1 j .20Z) by The fo Ding instrJ+(nent wa acknowledg before me this2�,dayof�or, 20 by RICHARD BASSOFF RICHARD BASSOFF Name of person making statement. Name of person making statement. Personally Known_ OR Produced Identification Personally Know l> OR Produced Identification Type of Identification Type of Ide III cation Produce Produced Nary acidic State of F �u/fatb� Noury Pudic State of Fonda +F Jacqueline Georgescu ; ;, , Jacqueline George J My Co r "on GG 23 My Commission GG 233150 `.�I� FM*" 06/28/2022 its e/20 2 n . ignatureb tary Publik A ON A atuof/a ublic- State of Florida ) Commiss No. (Seal) ommiss(Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev.2/7/19 Residential Electric Water Professional Classic Water Heaters 1 1 The new degree of comfort' Professional Classic® electric water heaters are engineered for longer Irfe - resistored heating elements and premium grade anode rod Efficiency •.90-.93UEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard' stainless steel lower element to prolong anode rod and tank life Performance • FHR: 45 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 90' F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • Rheemglase tank lining resists corrosion and prolongs tank Irfe • EverKleen self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream - helps operating efficiency by saving energy, money and improving tank life • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • HUD certified for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty' • With ProtectionPlus" the 6-year limited tank warranty becomes 10-year 'See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency Performance criteria. Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric UL IM111111111 See specifications chart on back. PRINTED IN U.S.A. MIS WP FOPM W. PROS RH N R.. 8 a Th.. degas of corcfW! Professional Classic® Specifications Residential Electric Water Professional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. T Y P E NOMINAL GALLON CAPAc11Y RATED GALLON c4UPA0mf =a& MGM OFT RRSITHOUR RATING "A RECDYBW IN GPI). WFRISE TANK HEK:NT A HEMNT TO WATER CONN. a DIAMETER c APPROX. SHIP W. PBM ONNmrN ENERGY TICTOP PER Tall 30 27 PROE30 T2 RH95' 46 21 47-1/2 50318 19-1/4 92 0.92 Tall 40 36 PROE40 T2 RH95' 55 21 60-3/4 63-5/8 19-1/4 109 0.93 Tall SO 45 PROE50 T2 RH95' 63 21 S83/8 61-5/8 20-1/4 121 0.93 Tall 55 55 PROESS T2 AH941 72 21 67 593/4 22-1/4 128 0.W Mad. 30 27 PROE30 M2 RH95' 45 21 37-12 40-12 20-1/4 W 0.90 Med. 40 36 PROE40 M2 RH95' 55 21 1 48-1/4 50-12 20-1/4 106 0.93 Med. 1 60 45 PROE50 M2 RH951 1 62 21 48 50-12 1 23 1 132 0.93 Short 19.9 PROE20 S2 RH 21 31-12 31-12 17 62 - Shod 28 25 PROE28 S2 RH95 45 21 30 31-1/8 1 23 95 0.92 Stun 30 27 PROE30 S2 RH95 B" 48 21 3LL1/8 32 1 19-314 95 0.92 Short 36 33 PRO©6 S2 RH95 46 21 31-12 33 24-1/4 .118 0.92 Short 38 35 PROE38 52 RH95 B" 51 21 31-12 W-5/8 23 108 0.92 Short 47 43 PROE47 S2 RH95 54 21 32 34 261/4 149 0.93 Uniform Energy Factor and rated gallon capacity bases on Department of EnaW (DOE) raquimmems. 1 System Sentinel optional. Add I W the end of 11te model number. System Sardine! not a rallabb an single element models, anaeable on Goal element models only. System Saidnel not avaOable In excess of 5 kW on 208 V models. •• Water theater Ormonears plcr to imtallkg Insulation banker that s inducted with water hams, • Heslos fvmi ocl Win Mandard 240 vJI AC, Binge plmo min dmilanse s wiring, and 4500 sett upper and lower heating samens. • of hosting, almonds of different wattages than Ihoee wn shoshe dismantled by sae npukemenls, they most be pedficaly m9useted • Sngle element models ayeiabe an spas®) order (FODOW max). SuIesVtute'I' for'2' In mortal number. • Special Wining Options -A limited amber d special wing optlorns are ealabe, corset factory for price ad volatility. • At madab equipped wen neat traps. Recovery = wattage/2.42 x temp. else °F. Example: 450DW = 21 GPH 2.42 x 90" Recovery calculations used am based on 4500 watt dements used in non-slmul a sacs operation. HOT WATER MCONNECTI COLD WATER E 4ODE ROD DIA ETER A O B WATER CONNECTIONS ALL 3/4" N.P.T. In kespeg with its polcyo/continuous progress andproduct improvement, Rheum reserves the right to make changes without notice. Rheum Water Heating a 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com PRINTED IN LLSA 05118 WP FORM NO. PAGE RH N Re, 8 ?' Admiral Plumbing Services Invoice 72018168 PLUMBING SERVICES A Service Experts Company Invoice Date 1/24/2021 A Service Experts Company 2895 Jupiter Park DR #700 Terms COD Jupiter, FL 33458 Completed 1-746-1180 Date 1/24/2021 56 License: CFC 1426115 Customer PO Billing Address Job Address Rachel Garfinkle Rachel Garfinkle 120 Blue Grotto Drive 120 Blue Grotto Drive Fort Pierce, FL 34945 USA Fort Pierce, FL 34945 USA Description of Work Replaced 55 gallon electric water heater in garage with a new 55 gallon electric water heater 4500 W elements with drain pan and expansion tank Permit fee included. Permit is required. Customer is responsible for any additional requirements for the building department. Task # Description Quantity Your Price Your Total ELCWHSTD- New Electric Water Heater - Standard Size 20-50 Gallon excluding 50 Gallon Low 1.00 $1,175.00 $1,175.00 L2 Tanks or Custom Sizes (See Premium / Custom Option) 6 Year Manufacturers Warranty (Upgrade to Premium for 10 Year) Access to heater is normal with no extraordinary installation requirements *MUST ADD: Required Permit to Meet Local Municipal, County and State Building Codes *MUST ADD: Installation Packages to meet Job Demands & Requirements ASK ABOUT OUR ADMIRAL ADVANTAGE BASIC PLAN — No worry hot water for only $32.99 PermitWH WaterHeater- Permit 1.00 $225.00 $225.00 *Required by Building Department ELCWHIP-STD ADMIRAL STANDARD INSTALLATION UTILIZING PRIMARILY EXISTING 1.00 $350.00 $350.00 COMPONENTS IF ALL ARE STILL IN GOOD CONDITION AND INSTALLED PROPERLY TO CODE Professional installation of New Electric Water Heater *Retrofit Copper Piping *install to Code *Haul off and Dispose / Recycle old Water Heater Discount Discount- Postcard 2.00 $-50.00 $-100.00 Paid On Type Memo Amount 1/24/2021 Check $1,650.00 Sub -Total $1,650.00 Tax $0.00 Total Due $1,650.06 Payment $1,650.00 Balance Due $0.00 1 hereby agree to have Admiral Plumbing Services A Service Experts Company complete the work described for the proposed price regardless of the time it takes to complete the work. 1/24/2021 1 hereby acknowledge the satisfactory completion of the above described work.