Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ATS
Automatic Transfer Swdch as _-..: w.. SUVice and non-serWce rated omatic marf Transfer fiches 100 - 400 Amps, Single Phase rL us -c�L��� Dosr.ription Generac Au ntaffc Trar>s<er Swr[c[3es are designed on svfthes lam available m single has in b oth seMceoequrpm rani and C.Q= Ier_ The 100, 2-00, and 400 amp op Bd non seMC:D e4�ment sated conngur ffom_ The `l50 and 300 amp Open iranssrbon swiEcheS are only available in a sernce ral equipment cflntigWL'jorL stmdalyd FOata r Service rand (�s�M Genetac AutornatiG Transfer Swnches are housed � an alnsninu[n NI�MANtType 3� encIosure�,ew[dlfor red and baked powder paint. The Heavy Duty Generac Contacror is a fJ1 recognized device, design etecffostaacally aPF tmclfons, and transrer conun ds_ All years of wince- The controller Itfte. generator handles all -dte ummg, sensing, exerGiSsng des are housed zn a stee3 enr os swtcites are covered by a - year rm ted warm*- * uon_SaMM r&d CFM) DpM TfaGh lolugY �l to manage up to 4 indMdual 4 VAG (2-4 VAC' p these swrtches have the � �emenr Module% TIP to 8 more lows can be Tnsough Este use or dsgmJ powestecttnafogy When used in Mdefn wrdt Smart Manag corrrsolled) loadst� no adCrrdonal hardware- onsavailable_ managed as well. PlMdd-mg ate most insp]]aa on erTrcient power managefnerrt opif GENERAL"' 100-400 Amps, Single Phase Automatic Smart Transfer SwItGhes Functions Ail timing and sensing funcffoas originate in the generabr controller Utility voltage drop-ouL — ..— .... _.__ ._ .. ..---- ----- _..._. ----- Timer to generator start -- --- ----.---.----------.---------_� — _----..__10 Second fi=y Set, adjustable be(ween 2--1500 seconds by a qualified dealer` Engine warm up delay --...._.._ ....................... seconds Standby voltage sensor.-------•----.--__. _ _—.... __.------••---------------...-- -•------__.-. -. 65% for 5 seconds UfiGtyvoltage pickup— ._ _ ...........-._. - ._._..__............ -- ---------...-._ —••------ Re-transfertima decay ... —_. ..-.....__....— — - ...._ .......-...._--_ _..._ __ - - -- -- _ ._ — — _ --------.-15 seconds Engine coal -down timer --- --------- .-....._.----------- ------- seconds Exerciser or 12 minutes adjustaWa weeldy/B-weekly/Mortly+" The vansferswitch can be oper3ied manually witboutpower applied. "When used in conjunc6an with units WlIzing Evolution— contras "" Adjustablav(a. the controller Sp eciftatio ns Model RKSC100A3 RXSWJDW RXSW15QA3 R=ZODA3 RX54N200A3 RXSW300AS RXSN4 OAS OA3 Amps 100 100 150 200 200 30D 400 400 Voltage 12fl/240,15 120/240,Iff 120/240.1.6 120/240,IF 120/Z40.15 1Z0/240,I 12DI24D,i15 1P2�0/T2r4�0,�15en Ope,Twisiton OpenTasitien OpenTrans%on DpenTarNn Open Service Rated peTit Service Rated ison T O Service Rated Load Tansition Type (Automatic) NEMAfUL3R Service Rated NaMvA/UL3R Wce Rated NaMAlUL3R NEMA/UL3R NHu1A/IJL3R NHvIAlUL3R NEMPJUL3R NENARIL3R Enclosure Type UL WCUL UL UL Rating UUCUL UL UL ULICUL UL w-*stand Rating in 22.000 10,DOQ 22,fl00 22,000 �. 000 22,OAD (Amps] 600 MCM - � or 110 - 250 M CM 1j0 -�14 250 MGM -#8 Lug Range Mode{ RXSC100A3 �O=UaA$ R)S1W150A3 WD200A3 Rn5W2A0A3 RSW300A9 RXSC400A3 ID5W400A3 fit 17241437E 1724(4379 26-75/5714 ITW43i.9 26.75/573.4 4291110839 31255ng B 291150893 Height [mJmm} 20/508 10/508 SO= ZO/508 30/T62 48/i2192 36/914.4 48112192 W1 125/3175 12-5/317-6 IU12551 125/3175 105067 16.591423.9 1918f467216.69/423.9 Width (nlmm) h2 14 6/370-8 14 fi/371.8 13-5/342 9 14-6/37D-8 135134z9 21.82l5542 241609.6 21.8215542 Dept)(mJmm) 7-0911801 7291180.1 6.31150_1 7.0911801 651i60.1 10.Ofi1255S 10Ofi255S 10.96/255.5 /9-07 2zVICZ1 39117.69 ZM-07 39117.69 1401835 132/6033 140163.5 Weight(IbsJ�los} 20 Uor�� N Generac Power Systems, Inc. - 545 W29230 HW (. 59, Waukesha, W[ 53189 - generac.c0m GE` ERAC �2u17 Generac poyv syslg=, Im All ri9ie; rrserved. All spea5m6ons are sutiectm cY_9e wiNoutnotic� 6u➢erin'Ie0©Goi3459-A 042417