HomeMy WebLinkAboutOC TRI ICE WATER NOA 20-100802MIAMI•
MIAMI-DADE COUNTY
In -I'll PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADNILNISTRATION DIVISION Miami, Florida 11175-2474
`r (786) 315-2590 F (796) 315-2599
NOTICE OF ACCEPTANCE (NOA) www atiamlaade•goy/economv
Owens Corning Roofing and Asphalt, LLC
One Owens CorningParkway
Toledo, OH 43659
SCONE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: WeatherLock G, WeatherLock MAT, AC Granular, & Tri-Built Granular
LABELING: Each unit shall bear a permanent label with the manufacturer`s name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official,
This NOA revises NOA #17-0206.02 and consists of pages 1 through 4.
The submitted documentation was reviewed by Freddy Semino
MtAMt ik�,E1E CC}UNiY NOA No_: 20-1008.02
Expiration Date: 04/03/23
Approval Date: 11/04/20
Page 1 of 4
GOOFING COMPONENT APPROVAL
Category:
Roofing
Sub-Categorv:
Underlayment
Material:
SBS
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
WeatherLock G
36" x 33.3' rolls
ASTM D 1970
SBS self -adhering modified asphalt underlayment
Manufacturing;
36" x 66.6' rolls
sheet material with a surfacing of opaque granules;
1:acation(s) # 1,'
for use as an underlayment in sloped roof
assemblies.
WeatherLock MAT
36" x 33.3' rolls
ASTM D 1970
SBS self -adhering modified asphalt underlayment
36" x 66.6' rolls
sheet material with a polymeric asphalt film
Mangy factr�ring
nu ng
surfacing; for use as an underlayment in sloped
La antu 2
roof assemblies.
AC Granular
36" x 33.3' rolls
ASTM D 1970
SBS self -adhering modified asphalt underlayment
!1lanufactitr ing
J
36" x 66.6' rolls
sheet material with a surfacing of opaque granules;
for use as an underlayment in sloped roof
Location(s) # I, 2
assemblies.
Tri-Built Granular 36" x 33.3' rolls ASTM D 1970 SBS self -adhering modified asphalt underlayment
Manufacturing 36" x 66.6' rolls sheet material with a surfacing of opaque granules;
La factu # I, 2 for use as an underlayment in sloped roof
assemblies.
MANUFACTURING LOCATION:
Brentwood, NI-1.
Houston, TX.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Narne/Report
Date
Momentum Technologies
JX19L5A
ASTM D 1970
02/02/18
International
AX08E7D
ASTM D 1970
02/02/18
PR.I Construction Materials
OCF-338-02-01
ASTM D 1970
01/26/18
Technologies, LLC
OCF-293-02-01
ASTM D 1970
01/26/18
OCF-295-02-01
ASTM D 1970
01/26/18
OCF-297-02-01
ASTM D 1970
02/08/ 17
1378TO100
ASTM D 1970
9/17/20
1378TO101
ASTM D 1970
9/17/20
NOA No.: 20.1008.02
MIAMMADEcourrrY Expiration Date: 04/03/23
' Approval Date: 11/04/20
Page 2 of 4
APPROVED ASsEMBt,ms:
Deck Type 1: Wood, non -insulated, new construction
Deck DescAption: 19/32" or greater plywood or wood plank.
System E(1) Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of Weatherf.ock G, Weatherf,ock MAT, AC Granular, or Tri-Built Granular
with a minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the
eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the
membrane is applied.
Surfacing: Approved for Asphaltic shingles, wood shakes and shingles, quarry slate roof assemblies.
ht4AMi DADS CC?tiC�YY NOA No.: 20-1008.02
O i� Expiration Date: 04/03/23
Approval Date: 11 /04/20
Page 3 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherLock G, WeatherLock MAT, AC Granular, or Tri-Built Granular underlayment
shall be installed in strict compliance with applicable Building Code.
3. WeatherLock G, WeatherLock MAT, AC Granular, or Tri-Built Granular underlayment shall be applied to a
smooth, clean and dry surface with deck free of irregularities.
4. WeatherLock G, WeatherLock MAT, AC Granular, or Tri-built Granular underlayment shall not be applied over
an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment.
5. WeatherLock G, WeatherLock MAT, AC Granular, or Tri-Built Granular underlayment shall not be left exposed as
a temporary roof for longer than 30 days of application,
6. Refer to Prepared Roofing System Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
`. WeatherLock G, WeatherLock MAT, AC Granular, or Tri-Built Granular underlayment may be used with any
approved roof covering Notice of Acceptance listing WeatherLock G, WeatherLock MAT, AC Granular, or Tri-
Built Granular underlayment as a component part of an assembly in the Notice of Acceptance. If WeatherLock G,
WeatherLock MAT, AC Granular, or Tri-Built Granular underlayment is not listed, a request may be made to the
Authority Laving Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Plash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly Current Product Control
Notice of Acceptance and applicable Building Code.
12. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed
in place and farmed around the protrusion to ensure a tight fit. A second layer of WeatherLock G, WeatherLock
MAT, AC Granular, or Tri-Built Granular underlayment shall be applied over the underlayment.
13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Mule 61G20-3 of the Florida Administrative Code.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and
the following statement: "Miami -Dade County Product Control Approved" or the Miami -bade County Product
Control Seal as shown below.
END OF THIS ACCEPTANCE
N aA No.: 20-1008.02
MIMNDADECOurvrr
f i Expiration Date: 04/03/23
Approval Date: 11/04/20
Page 4 of 4