HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building'& Zoning 2 100 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: (Print or type) Address: Date: Gv4vn� y 10RGlpr Physical ocation of Home) &T Year / Manufacturer 19 73 up Serial # O�j/(,rt %7 3 (? HUD Plate # �! WIC � - th a Length_-6—O Single Double Wind Zone C = In Compliance N = Not in Compliance Fire Safety / Electrical 1. Smoke Detector: Installed . t/ Missing I� 2. Electrical System. Checked: Exposed Wiring Other C 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other _ 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire GFCI receptacles not where required G 5. Electrical Ground: Chassis Main Panel Gas Pipe Ra ud 319105 Pacye I of r, IlkZ1�+i r� yc 44. Qk x$t� Construction 1. Exit Doors Operable: Front Back -jC_ 2. Exit Door Locks: Missing Inoperable /' - — Other, - - — — inoperaole C 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged C7. Interior Paneling: Missing Loose Damaged C 8. Rodent Proofing: Bottom Board Pipe openings Other -C- 9. Leaks Apparent: Ceiling Doors Floor Roof Ce 10. Vertical tie -down straps: Missing Short Damaged C 11. Structural modifications since manufactured: YES_ N0_A,,/ C 12. Walls: Structurally Unsound Loose Weather tight Plumbing /C 1. Trap: Missing Not connected Other C2. Plumbing fixtures: Missing Not installed Not Vented C 3. Relief Valve: Missing __ Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning C 1. Heating Appliances: Missin 2. Deleted Heating/AC system: Not installed G3. Thermostat: Missing Not Connected Inoperable Other C 4. Air registers: Missing Inoperable G5. Ducts: Not sealed Missing Collapsed Page 2 of 3 Other r _ C. 6. Gas furnace Water heater vent: :Missing Loose 7. Return Air: To Furnace To A/C From rooms C 8. Range: Vent Hood C 9. Gas Valve: Accessible Installed improperly j a C10. Gas lines: Not capped Pp Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO 2. Will a remodeling permit be required? YES NO _ The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Suc provisions shall include, but not be ited to, standards for structural adequacy, 'plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DD/CU.MENT, SIGN AND AFFIX THEIR SEAL. Date inspected:61V1 Q nspected By:LE �,D License # 31 � Signature required , 'hone Number: 1 i• 2) e - 7 .2'Y 3 STEVEN G. WOOD, P.E. FL LICENSE 34398 950 SULTAN DR PORT ST LUCIE, FL 'i(la/os. Engl eers Sea!