Loading...
HomeMy WebLinkAboutPermit WorksheetsK NERMIT-NUMBER Installer �(® r� �y` f"r� License ff .^I 0a0� �-77 Address of home being installed Manufacturer C100-0 f Length x width C .. 9, NOTE. If home is a single wide fill out one half of the blocking plan If home is a triple or quad wide sketch In remainder'af home l understand Lateral Arm Systems cannot be used on any home (newer uypd) where the sidewall ties exceed 5 It 4 in. l_ Installer's initials Typical pier spacin� 2' lateral Show locations of Longitudinal and Lateral Systems longitudinal (use dark lines to show these locations) marriage wall plers within V ar end of home par Ruts ISC 1. MUST BE INEPT ON J06 vA NO INSPECTION WILL BE MADE PERMIT WORKSHEET 1 pugo 1 of 2 r, New Home lJsd dome fl Home installed to the Manufacturer's Installation Manual [] Nome is installed in. accordance with Rule 15-C ((7� Single wide ❑ Wind Zone Il [� Wind Zone Ill El QoO fe wide ;«; Installation Decal # Triple/Quad ❑ Serial 0 :3 G S-f,4 PIER SPACING TABLE FOR USED HOMFs Load bearing capacity Fouler size (sq In) 16' x 16' (256) 18 1/2' x 18 1/2' (342) 20' x 20' (400) 22' x 22' (484)' 24' X 24' (576)' 26' x 26- (676) 1000. s 3 4 5 8 11500 sf 4r 6 6 7 8 2000 sf g 2500- s 7 6 8 8 8 8 g -3000 s 8 61 a 8 8 3500 psi I 8 8 8 8 PIER PAD SIZES D I-beam pier pad size d 7C x Perimeter pier pad size X ,;;"y Other pier pad sizes (required by the mlq.) Draw the approximate locations of marriage wall openings 4 foot or greater._ Use this rr symbol io show the piers. List all marriage wall openings greater than 4 toot and their pier pad sizes below. Opening Pier pad size 81, l _2-y x;-y WORK TIEDOWN COMPONENTS is Longitudinal Stabit((zingg Device (LSD) HAVanufaclur . dl I✓le, ?- Longitudinal Stabillzi De lce w/ Lateral Arms • -Manufacturer�� _ POPULAR PAID SIZES �I"• si�YE��-YIGI h3'iei i 1ldi ['ti i WA MAOWN �%3'�Id•■R9. ANCHORS 4 It 5 It FRAME TIES within -2' of On(] of home spaced at 5' 4" oc OTHER TIES Number sidewall 0__ Longitudinal �-'- Marriaqe wall ��- Shearwall PLHMII WCJRKSHEET PER,Nlti NUMBER .' POCKET PENETROMETER TEST The pocket penetrometer tests are roundedwn to psf or check here to declare 11000 Ib. soil without testing. x150p x ti oo x 35D D POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the tooter, 3. Using 500 lb. increments, take the lowest reading and round down to that increment. x 1 '900 x 1500 x i Ed-'? TORQUE PROBE TEST The results of the torque probe test is 4257 inch pounds or check here if you are declaring 5' anchors withouttesting fJ ^ . A test showing 275 inch pounds or less will require 5 toot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. i understand 5 it anchor's are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4 0k4 holding capacitV• (lp� ti Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name Date Tested I page 2 of 2 1. Debris and organic material removed 1-1 Water drainagw,Natural d Swale Pad Other Floor: Type Fastener: ~ mat f Length: fi_ Spacing: Walls: Type Fastener. �� Length: Cs Spacing: Root; Type Fastener: Length: _"_ Spacing: For used homes a n. 30 gauge, B" wide, galvanized metal strip will be centered over the peak of the root and fastened with galy. roofing nail's at 2" on center on both sides of the centerline. Gasket (weelherpmafing requleement) I understand a properly installed gasket is a requirement of all new and us rri homes and that condensation, mold,meldew and buckled marriage walls are. a result of a poorly installed or no gasket being installed. l understand a strip of tape will not serve as a gasket. ( Installer's initials\ 0 t 614 �6_A e Type gasket T' y Installed: Pg, Between Floors Yes Between Walls Yes j Bottom of ridgebeam Yes I_ Electrical 7onnect electrical conductors between multi -wide units, but not to the main power source. This includes the bonding wire between mull -wide units. Pq._ Plumbing ;onnect all sewer drains to an existing sewer tap or septic tank. Pq. 'p,5 -t ,onnecl all potable water supply piping to an existing water meter, water lap, or other idependenl water supply systems. Pq. �.NW Weatherproofing The bottomboard will be repaired and/or taped. Yes Pq. Siding on units is installed to manufacturer's specifications. Yes Fireplace chimney installed so as not to allow intrusion of raiq-water, Yes -tdA Miscellaneous ■ Skirting to be installed'. Yes `/ No Dryer vent installed outside of skirting. Yes N/A - Range downflow vent installed outside of skirting. Yes -N/A ■ Drain lines supported at 4 foot intervals. Yes Electricagv oroers rolected. Yes r/ . Other- I,c a rs'� _0 1+ O a 6 i e� • _ er verifies all information given with this permit worksheet is accurate and true based on the Installer Signature D"ato