Loading...
HomeMy WebLinkAboutAPPROVED, engineer plans, surveyEXISTING 6' WOOD FENCE O Z SELF -CLOSING, SELF -LATCHING GATE O a m Ir z m EXISTING 6' WOOD FENCE 16 ft 82 ft. PROPERTY LINE -----+- ---------------------i -----------------------------1- 6' PUBLIC UTILITY EASEMENT ----------------------------- I I I � I (o I I ' c`li 13 ft. 2 in. 49 ft. 18 ft. 1 I a I I 1 I 1 I I I I I I I I I 1 I I I I 1 I I I I I I I I I 1 I I I 2104-0174 I / I I 5' DEEP I / I . I j' EXISTING 6' 5ft. /2/t 6� /"� WOOD FENCE 00 n. N / I 3' DEEP I I ft. 8 in. I ILI N / z -� 9 ft. 4 in. I J (0 I I ®g/ I Of RESIDENCE o 0- ® ; I O ®r®m• i Of i 1 POOL ALARMS ON DOORS AND WINDOWS LEADING TO POOL AREA 72 ft. PROPERTY LINE c M v 15 ft. 9 in. ELECTRIC METER 150 AMP SELF -CLOSING, SELF -LATCHING GATE ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85 DB A AT 10 FEET (3048 MM). ANY DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. FENCE/GATES DESIGN TO BE IN COMPLIANCE WITH POOL SAFETY BARRIER REQUIREMENTS FBC R4501.17 R4501.17.1 A WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1 3/4 INCHES IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1 3/4 INCHES IN WIDTH. R4501.17.1.5 WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS 45 INCHES OR MORE, SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4 INCHES. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1 3/4 INCHES IN WIDTH. R4501.17.1.6 MAXIMUM MESH SIZE FOR CHAIN LINK FENCES SHALL BE A 2-1/4 INCH SQUARE UNLESS THE FENCE IS PROVIDED WITH SLATS FASTENED AT THE TOP OR BOTTOM WHICH REDUCE THE OPENINGS TO NO MORE THAN 1 3/4 INCHES. R4501.17.1.7 WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE NO MORE THAN 13/4 INCHES. NOTES : IF WATER SOURCE IS A PRIVATE WELL- PRE -FILTER WATER TO FILL POOL ALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (W. listed) FROM POOL STEEL. ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...._ G.F.I. OUTLET 10' MIN. AND 20' MAX. FROM POOL IF ENCLOSURE IS REQUIRED ADD SCREEN OR FENCE AROUND POOL OR PROPERTY GATES TO BE SELF CLOSING AND SELF LATCHING PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED STEEL OVERLAP @ 48 TIMES DIAMETER ESTABLISH THE LOCATION OF ALL UTILITIES AT SWIMMING POOL CONSTRUCTION SITE AND HOLD MINIMUM CLEARANCE DIMENSIONS ESTABLISHED BY THE LOCAL REGULATORY AGENCY. ALLOW MIN. 10' HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRIC LINES TO POOL WATER. DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NO SHARP EDGES AND BE POSITIVELY SLOPED FOR DRAINAGE PROVIDE WEEP HOLES AND DEWATERING PUMPS AND ANY OTHER METHODS NECESSARY TO PREVENT THE POSSIBILITY OF THE POOL FLOATING DUE TO HYDROSTATIC UPLIFT PRESSURE WHEN THE POOL IS EMPTY. BACKFILLING OF THE POOL SHALL BE DONE CAREFULLY TO ASSURE THAT NO DAMAGE TO THE PIPING OCCURS AND BACKFILLING SHALL BE DONE WITH CLEAN SOIL FREE FROM ORGANICS AND DEBRIS AND SHALL BE COMPACTED SO THAT NO VOIDS EXIST PROVIDING A FIRM BEARING FOR THE DECK ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL POOL PIPING SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI (241 KPA) FOR 15 MINUTES. THIS IS NOT DIVING POOL. SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BREAKER LOCATE POOL RETURNS DOWN 18" MIN. BELOW THE POOL BEAM POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.E /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2020 7th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) REINFORCING STEEL SHALL BE ASTM DESIGNATION A615 GRADE 60 WITH A MINIMUM YIELD STRESS OF 60 KSI, REINFORCING BARS SHALL BE NEW DEFORMED BARS OF BILLET STEEL FREE FROM OIL, SCALE OR RUST. ALL SPLICES, LAPS AND PLACEMENT SHALL CONFORM TO ACI 318-89, 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2017 NEC SECTION 680.26(C) Digitally signed by Bradley Akers : cn— ra ey ...... Akers QO \CENg' .f o=PoolDesign.n * : No. 68449 = et, ou, J,p�O� /STA�TEtOP email=info@swi F'51 °R°° �5 , mmingpoolplan. ' SIO ` ''�r�A� com, c=US Date: 2021.02.25 11:32:03-05'00' B. M. AKERS P.E. 68449 POOL AREA PLAN TITLE ORTON RESIDENCE DESCRIPTION 2421 TAMARIND DRIVE FT. PIERCE FL. 34949 Scale: 1 in = 20ft. Oin. DATE 2/25/2021 PAGE 1 OF 4 POOLDESIGN.NET 18 ft. /R I R 2'-0" 14 ft. 1 in. SKIMMER 5' DEEP 0 32CDFL AQUASTAR MAIN DRAIN Wa911111:1U HAYWARD W 400 1-1/2" CLEANING FITTING W/COVER INSTALLED 6" TO 12" BELOW WATER LINE = 5 ft. C� M CO C"I N N / RESIDENCE POOLDESIGN. NET 12V LED 3' DEEP i ft. 11 im R2'0. 2'0„ 00 0 9 ft. 4 in. 4 ft. 4 in. I I / I I 13 ft. 2 in. I 1 I • I / 1 / I I �• I 1 I I R 2'-0" 1 ,• 1 I ! I I 1 1 / I I /• I 1 �• 1 1 I I �• I 1 I ,• I i/ EXISTING 6' / WOOD FENCE I /I , I / I / 1 / 1 1 I I 1 1 I I I I I ! 1 ,• 1 I ! ,• 1 1 I ,• I ! I ,• I I /• 1 ! ! ,• I I I 1 6 ft. 8 in. / I I I ,• I I 1 I ! 1 ! 6 ft. 8 in. /• 1 ! 1 I �• I 1 I �• I ! �• I I /• 1 ! I I POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2020 7th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) REINFORCING STEEL SHALL BE ASTM DESIGNATION A615 GRADE 60 WITH A MINIMUM YIELD STRESS OF 60 KSI. REINFORCING BARS SHALL BE NEW DEFORMED BARS OF BILLET STEEL FREE FROM OIL, SCALE OR RUST. ALL SPLICES, LAPS AND PLACEMENT SHALL CONFORM TO ACI 318-89. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2017 NEC SECTION 680.26(C) Digitally signe by Bradley Ake _ DN: cn=Bradle \,,,,,I���II,,,,, ,,��y MITC. EIIz Akers ••��CENSF•'�� o=PoolDesign. * ; No. 68449 ; * = et, ou, F<oRtoPemail=info@s 0 mmingpoolplal com, c=US Date: 2021.02. 11:32:30 -05'00 B. M. AKERS P.E. 68449 LAYOUT PLAN TITLE ORTON RESIDENCE DESCRIPTION 2421 TAMARIND DRIVE FT. PIERCE, FL. 34949 Scale: 1/4" = 1'-0" DATE 2/25/2021 FGE 2 OF 4 .s 1 I 5 I I I I I I I I I I / I /• I. I/ •I / I I / I / I j I I / I j I I / I / I I / I / I I / I / I I / I / I j I I / I / I /• I I / I / I / I I / I / I I / I / I VDUIT FOR POOL LIGHT I %CUUM LINE I VDUIT FOR POOL LIGHT j ;KIMMER LINE I 2" POOL MAIN DRAIN LINE j ZETURN LINES I I I I I LUMBING IS I -TOWN SPACED DR CLARITY I I I I I I I I I :LECTRIC METER I 50 AMP I I I I I I I I EXISTING 6' WOOD FENCE POOLDESIGNMET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2020 7th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) REINFORCING STEEL SHALL BE ASTM DESIGNATION A615 GRADE 60 WITH A MINIMUM YIELD STRESS OF 60 KSI. REINFORCING BARS SHALL BE NEW DEFORMED BARS OF BILLET STEEL FREE FROM OIL, SCALE OR RUST. ALL SPLICES, LAPS AND PLACEMENT SHALL CONFORM TO ACI 318-89. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2017 NEC SECTION 680.26(C) Digitally signed by Bradley Akers MIT CHEZ ��`�.•���E'NS �9�F,,, Akers, �- *� o=PoolDesign.n No. 68449 * t, o U, STATE OF email=info@swi `� mmingpoolplan. IONAL���,,. om, C=US Date: 2021.02.25 11:32:50-05'00' B. M. AKERS P.E. 68449 PIPING PLAN TITLE ORTON RESIDENCE DESCRIPTION 2421 TAMARIND DRIVE FT. PIERCE, FL. 34949 Scale: 1/4" = 1'-0" DATE 2/25/2021 PAGE 3 OF 4 XISTING G.F.I. "J��gpX 4' MIN. MAIN u o (NOTE BELOW) PANEL -- 3 #12 IN 1/2" DECK DETAIL CONDUIT PAVER CEMENT DECK 8" EDGE Q0O1 0 3- #3 CONT. IIIIIIIfIA— GFIIIIIII IN 8" X 8" BEAM ' ��IIIIIII®IIIIIIICONTROLLER i #8 AWG SOLIDCOPPER BONDINGCOAT BOND CONNECTION JUMPERW/APPROVED POTTING - - �'- - - - -' LIGHT CORDCOMPOUND - - - T(IN CONDUIT);12v TRANSFORMER - - --------- CHLORINATOR -----------' GFI PUMP 12V UNDERWATER BREAKERS UL APPROVED LIGHT 3#12IN1/2" _ /- CONDUIT --- / • • 6" WALLS W/ #3 STEEL #8 AWG INSULATED @ 12" O/C HORIZONTAL COPPER & VERTICAL WIRE EPDXY COATED 220V POOL PUMP O/C BOOTH WAYS STEEL @ 12" PUMP MOTOR 1.65 HP VARIABLE SPEED JANDY COMPLIES WITH PLASTER FINISH 403.9 FBC & NEC ►� 430.32 6„ SA ALL ELECTRICAL PER 2017 N.E.C. POOL STEEL OVERLAP @ 48 TIMES DIAMETER ALL EQUIPMENT TO ALL METALLIC ITEMS WITHIN 5'-0" OF WATERS EDGE OF POOL TO BE BONDED BE INSTALLED PER WITH #8 SOLID INSULATED WIRE (UL listed) FROM POOL STEEL. ALL GROUND MANUFACTURER WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...... G.F.I. OUTLET 10' ANTI - ENTRAPMENT AQUASTAR Z VGB LL APPROVED Z MAIN DRAIN Z J 32CDFL101 32" �. POOU SPA MAIN DRAIN DET, '-EGEND: RETURN LINE ELEVATION 2-WAY VALVE 3-WAY VALVE CHECK VALVE fBUTTERFLY VAL SKIMMER VALVE ACTUAT( NTS NOT TO SCALE TRANSFORMER "J" BOX 12" MIN. ABOVE WATE LINE 5 IN. 28'-3" 4' MIN. 30" 12" 12" 0 o MAXIMUM FLOOR SLOPE r c� 1 ft. IN 7 ft N VGB APPROVED MAIN DRAIN GRATE p SECURED IN PLACE SO TOOLS ARE REQUIRED FOR REMOVAL HYDROSTATIC VALVE WITH WELLPOINT 5'-O" POOL SECTION Scale: nts GRAVEL SUMP o...... .������� POOLDESIGN. NET AQUASTAR MAIN DRAIN 32CDFL101 - 316 GPM @ 3.9 FPS FLOOR INSTALLATION '------------- -= BOND GRID PER 2017 NEC (680.26C "EQUIPOTENTIAL BONDING GRID"): #8 AWG BARE SOLID COPPER BONDING JUMPER SHALL BE INSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETER OF THE POOL OR SPA AND CONNECT POOL STEEL TO DECK STEEL OR BOND GRID WITH APPROVED LUGS. L STING 00 RALTEELENT BENCH DETAIL SET SKIMMER PLUMB & LEVEL 6„ 0 COPING M MIN. 3" CONCRETE COVER #3 BARS TYP. SKIMMER SECTION 18" MIN. LAP POOL BEAM (2) #3 BARS 00 MIN. 3" CONCRETE COVER 6 SKIMMER PLAN VIE 1. TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING PEAK HOURS 2. POOL FILTRATION PIPING MUST BE SIZED SO THAT THE VELOCITY DOES NOT EXCEED 8FPS IN THE RETURN LINE AND 6FPS IN THE SUCTION LINE. 3. FILTER AREA BASED ON 6 HOUR TURN OVER FLOW RATE 4. FILTER PUMPS - A MIN. OF 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE PUMP. 5. INLET FITTINGS SHALL BE DIRECTIONAL 6. PROVIDE A MIN. 18" OF HORIZONTAL OR VERTICAL PIPE BETWEEN FILTER AND HEATER OR DEDICATED SUCTION AND RETURN LINES SHALL BE INSTALLED TO ALLOW FOR FUTURE ADDITION OF SOLAR HEATING EQUIPMENT. 0-1 w PUMP 3" L. 1/4" TAP CON BOLTS @4 CORNERS 4" THICK CONCRETE SLAB EQUIPMENT ANCHORAGE DETAIL ANSI/APSP-7 LINE TYPE IZE IFLOW (GPM) IFPS MAIN DRAIN LINE POOL 1 2-1/2" 1 80 5.23 RETURN LINE 1 2" 1 80 8.17 ANSI/APSP-15 -INE TYPE v1AIN DRAIN LINE POOL RETURN LINE POOL SPECIFICATIONS LENGTH WIDTH MIN. DEPTH MAX. DEPTH AREA PERIMETER GALLONS INLETS LIGHT(S) PUMP FILTER MAIN DRAINS SKIMMER IZE IFLOW (GPM) IFPS 2-1/2" 26.7 1.75 2" 26.7 2.73 POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2020 7th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) REINFORCING STEEL SHALL BE ASTM DESIGNATION A615 GRADE 60 WITH A MINIMUM YIELD STRESS OF 60 KSI. REINFORCING BARS SHALL BE NEW DEFORMED BARS OF BILLET STEEL FREE FROM OIL, SCALE OR RUST. ALL SPLICES, LAPS AND PLACEMENT SHALL CONFORM TO ACI 318-89, 6 PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2017 NEC SECTION 680.26(C) Digitally signed by Bradley Akers ,•�``y MIT CHf��'�%,,, ,�o�� — : cn— ra ey Akers, .•\C'E'NsF• ��. ••ems o=PoolDesign.n * ; No. 68449 ; * = et, ou, .p. STATE OF : �� f0 email=info@swi `0Rj0 mmingpoolplan. com, c=US Date: 2021.02.25 11:33:14-05'00' 28 ft. 3 in. B. M. AKERS P.E. 68449 18 ft. 0 in. 3 ft. 0 in. 5 ft. 0 in. DETAILS 385 S.f TITLE ORTON RESIDENCE 83 ft 11,500 DESCRIPTION 2421 TAMARIND DRIVE FT. PIERCE, FL. 34949 WALL 1-1/2" DIRECTIONAL INLETS (1) LED 12V - PENTAIR (1) 1.65 JANDY VARIABLE SPEED CARTRIDGE CS 200 - JANDY DATE 2/25/2021 AQUASTAR 32CDFL101 1 1PAGE 4 OF 4