HomeMy WebLinkAboutAPPROVED, sheet 4 of 4 changesXISTING G.F.I. �(NOTEBELOW) "J"BpX 4' MIN. MAIN u DECK DETAIL PANEL -- [� 3 #12 IN 1/2" CONDUIT PAVER CEMENT DECK 8" EDGE 001 0 3- #3 CONT. IIIIIIImIA— GFI IN 8" X 8" BEAM CONTROLLER i CO 1111111 #8 AWG SOLID COPPER BONDINGCOAT BOND CONNECTION JUMPERW/APPROVED POTTING '------- ' = LIGHT CORDCOMPOUND (IN CONDUIT) ' 12v TRANSFORMER =--------------------------CHLORINATOR -----------' GFI PUMP 12V UNDERWATER BREAKERS UL APPROVED LIGHT 3 #12 IN 1/2" / CONDUIT 6" WALLS W/ #3 STEEL #8 AWG INSULATED 44@ 12" O/C HORIZONTAL COPPER & VERTICAL WIRE EPDXY COATED 220V POOL PUMP O/C BOTH WAYS STEEL @ 12" PUMP COMPLIES WITH PLASTER MOTOR FINISH 403.9 FBC & NEC ►� 1.65 HP VARIABLE 430.32 SPEED JANDY 8A POOL STEEL OVERLAP @ 48 TIMES DIAMETER ALL ELECTRICAL PER 2017 N.E.C. ALL EQUIPMENT TO ALL METALLIC ITEMS WITHIN 5'-0" OF WATERS EDGE OF POOL TO BE BONDED BE INSTALLED PER WITH #8 SOLID INSULATED WIRE (UL listed) FROM POOL STEEL. ALL GROUND MANUFACTURER WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...... G.F.I. OUTLET 10' ANTI - ENTRAPMENT AQUASTAR z VGB I ,, APPROVED Z MAIN DRAIN Z 32CDFL101 < 32" '-EGEND: OR RETURN LINE ELEVATION 2-WAY VALVE 3-WAY VALVE CHECK VALVE BUTTERFLY VAL SKIMMER VALVE ACTUAT( NTS NOT TO SCALE lee • - A� • TRANSFORMER "T' BOX 12" MIN. ABOVE WATE LINE 5 IN. 28'-3" 4' MIN. 30" 12" 12" � III MAXIMUM FLOOR SLOPE 0 cY) 1 ft. IN 7 ft N VGB APPROVED MAIN DRAIN GRATE p SECURED IN PLACE SO TOOLS -1 ARE REQUIRED FOR REMOVAL Lo HYDROSTATIC VALVE WITH WELLPOINT POOL SECTION Scale: nts GRAVEL SUMP AQUASTAR MAIN DRAIN 32CDFL101 - 316 GPM @ 3.9 FPS FLOOR INSTALLATION '------------------`------------------= BOND GRID PER 2017 NEC (680.26C "EQUIPOTENTIAL BONDING GRID"): #8 AWG BARE SOLID COPPER BONDING JUMPER SHALL BE INSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETER OF THE POOL OR SPA AND CONNECT POOL STEEL TO DECK STEEL OR BOND GRID WITH APPROVED LUGS. ANSI/APSP-7 SET SKIMMER jjo�- PLUMB & LEVEL �I,I,I'I'I'I'... ® COPING CONCRETE COVER #3 BARS TYP. SKIMMER CONCRETEPOOLBEAM COVER SKIMMER PLAN VIEW,41';� 1. TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING PEAK HOURS 2. POOL FILTRATION PIPING MUST BE SIZED SO THAT THE VELOCITY DOES NOT EXCEED 8FPS IN THE RETURN LINE AND 6FPS IN THE SUCTION LINE. 3. FILTER AREA BASED ON 6 HOUR TURN OVER FLOW RATE 4. FILTER PUMPS - A MIN. OF 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE PUMP. 5. INLET FITTINGS SHALL BE DIRECTIONAL. 6. PROVIDE A MIN. 18" OF HORIZONTAL OR VERTICAL PIPE BETWEEN FILTER AND HEATER OR DEDICATED SUCTION AND RETURN LINES SHALL BE INSTAL TO ALLOW FOR FUTURE ADDITION OF SOLAR HEATING EQUI 3" L. 1/4" TAP CON BOLTS @4 CORNERS 4" THICK CONCRETE SLAB — EQUIPMENT ANCHORAGE DETAIL w PUMP i— J LL n LINE TYPE IZE FLOW (GPM) IFPS MAIN DRAIN LINE POOL 1 2-1/2" 1 80 1 5.23 RETURN LINE 1 2" 1 80 1 8.17 LINE TYPE IZE IFLOW (GPM) IFPS MAIN DRAIN LINE POOL 2-1/2" 1 26.7 1.75 RETURN LINE 2" 1 26.7 2.73 PUMP JANDY VS 1.65 H.P. URVE A @1725 36 GPrV GALLONS 11,50 URN OVER 7.17 HOUR FILTER RATE MAX. .375 GAL PER S.F. POOL SPECIFICATIONS LENGTH WIDTH MIN. DEPTH MAX. DEPTH AREA PERIMETER GALLONS INLETS LIGHT(S) PUMP FILTER MAIN DRAINS SKIMMER POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.E /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2020 7th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI3, ANSI/NSPI5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) REINFORCING STEEL SHALL BE ASTM DESIGNATION A615 GRADE 60 WITH A MINIMUM YIELD STRESS OF 60 KSI. REINFORCING BARS SHALL BE NEW DEFORMED BARS OF BILLET STEEL FREE FROM OIL, SCALE OR RUST. ALL SPLICES, LAPS AND PLACEMENT SHALL CONFORM TO ACI 318-89. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2017 NEC SECTION 680.26(C) Bradley Akers \``„IIt DN: cn=Bradle y V CHEZ y \ �c E'Ns Akers, ND. s84 s*�= o=PoolDesign.ne * ou, ;.p STATE OF email=info@swin `� •.........0 0R`mingpool I'an.co m, c=US Date: 2021.04.09 28 ft. 3 in. 14:18:42-04100' 18 ft. 0 In. B. M. AKERS 3 ft. 0 in. P.E. 68449 5 ft. 0 in. DETAILS 385 S.f TITLE 83 ft ORTON RESIDENCE 11,500 DESCRIPTION WALL 1-1/2" DIRECTIONAL INLETS 2421 TAMARIND DRIVE (1) LED 12V - PENTAIR FT. PIERCE, FL. 34949 (1) 1.65 JANDY VARIABLE SPEED CARTRIDGE CS 200 - JANDY DATE AQUASTAR 32CDFL101 4/9/2021 1 PAGE 4 OF 4 POOLDESIGN.NET