HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie C oulity Bui]dil1� &; Zoning �00 Virginia Avenue Ft Pierce, FL _) Mobile Home Inspection Report All requests for its to place or replace used Mobile / Manufactured homes must be accompanied b this completed Inspectign Report and copies of both sides of the Title to the home. y All used Mobile homes must be Wind Zone II certified. Owner: (Print or type) Address Year / Manufacture; Date: 00 Aw- 601-cm Y C'. Q8 F-t PIER -Cc FL S012 aS& STA Serial # a72541 4XTR HUD Plate # �Jltih_�{—__— Length__ 150 Sin le / 9 _____�, Double V _ V/ind Zone_ C = In Compliance N = Not in Compliance 4 Fire Safety / Electrical — 1. Smoke Detector: Installed Missing_ 2. Electrical System Checked: Exposed Wiring Other G 3. Distribution Panel: Missing Loose Main Missing Breaker'Missing Unplugged Opening Other _ 4. Electrical Fixtures: Missing -_— Installed Improperly_ Improperly Wired Loose Wire CGFCI receptacles not where required 5, Electrical Ground: Chassis Main Panel Gas Pipe � j0d 319105 Page I of 3 Construction 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable 4. Windows: Broken Glass__ Inoperable_ G5. Screens: Missing Dama9 ed 6. Floor System: Joist Decking Area Damaged 7., Interior Paneling: Missing Loose __ Damaged 8. Rodent Proofing: Bottom Board Pipe openings Other �_ 9. Leaks Apparent: Ceiling Doors Floor Roof 10. Vertical tie -down straps: Missing Short Damaged C11., Structural modifications since manufactured: YES_ NO 12. Walls: Structurally Unsound Loose Weather tight Plumbing C1. Trap: Missing Not connected Other 2. Plumbing fixtures: Missing Not installed Not Vented C 3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Pipirag� Missing Not supported { Clean outs Use of fittings Not capped Heating and Air Conditioning = 1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed Other 3. Thermostat: Missing InoP erable C4. Air registers: Missing Inoperable _ 5. Ducts. Not sealed Missing Collapsed Page 2 of 3 L 0 Py Ft4-` y • ._._.C_.. 6. Gas furnace Water heater N•erlt: Mlssln Loose _ 7. Return Air: To Furnace To A/C From rooms 8. Range: Vent Hood 9. Gas Valve: Accessible � Installed improperly. 10. Gas lines: Not capped Not supported Kinked _ Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or teriorated? YES 2. Will a remodeling NO permit be required? YES NO The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include but not be ited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 a IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERM IT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED, A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX gate inspected: p� ispected By: jra"ffcvwC Signature required ione Number: ( 6 z)__ 5-73a� THEIR SEAL. License #3q g K r Py STEVEN G. WOOD, P.E. FL LICENSE 34398 950 SULTAN DR PORT ST LUCIE, FL Engineers Seal