Loading...
HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building' & Zoning 2 00 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: tALT Y Date: 'j ((Print or type) Address: �p d ! I. ] _ 1 . 111 l� % (Physical Location of Home) Year/ Manufacturers Serial #XL( a49—T HUD Plate # th_ Length Zone Ith g Single V Double Wind -- �^ C = In Compliance N = Not in Compliance R' RE PA'I RA BL.E Fire Safety / Electrical G1. Smoke Detector: Installed Missing G 2. Electrical System Checked: Exposed Wiring Other G 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other C 4. Electrical Fixtures: Missing __ Installed Improperly Improperly Wired I I Loose Wire CGFCI receptacles not where required 5. Electrical Ground: Chassis Main Panel Gas Pipe i : %ised 319105 Construction 1. Exit _$ Doors Operable: Front C Back Other 1 ID �� � 2. Exit Door Locks: Missing Inoperable --4. Windows: Broken Glass — le Inoperable_ 5. Screens: Missing Damaged C 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing Loose C ,_ Damaged J 8. Rodent Proofing: Bottom Board 9. Leaks Apparent: Ceiling Doors Pipe openings Other C Floor Roof 10. Vertical tie -down straps: Missin 9 _C— 11. Structural modifications Short Damaged since manufactured: C YES_ N0_V' _ 12. Walls: Structurally Unsound Loose Weather tight Plumbing C 1. Trap: Missing Not connected Other_ 2. Plumbing fixtures: Missing Not installed Not Vented C 3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed Other C 3. Thermostat: Missing Inoperable C 4. Air registers: Missing Inoperable 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 6. Gas furnace Water heater vent: Missing Loose 7. Return Air: To Furnace To A/C From rooms _L 8. Range: Vent Hood .� 9. Gas Valve: Accessible Installed improperly C 10. Gas lines: Not ca ed PP Not supported ' Kinked Notbonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES 2. Will a remodelin --__ N0�_ g permit be required? YES NO_�, The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be- ited to, standards for structural adequacy, Plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN 1N ST. LUCIE COUNTY. TY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY, UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DO/CU.MENT, SIGN AND AFFIX )ate inspected: 3 a Q Ispected By: 6rt—uaff6o Signature required hone Number:'(Mn_m 73� THEIR SEAL. I L P ,�y ss K �a � �� ��. � 7t l LJ r STEVEN G. WOOD, P.E. Page 3 of 3 n LICENSE 34398 9W SULTAN DR PORT ST WCIE, FL 3��a�oS Engineers Seal