HomeMy WebLinkAboutPermit WorksheetsPERMIT NUMBER
Installer License # t`7(� -�
Address of home _ /L ZJ to.V
being installed
Manufacturer ���^ Length x width
NOTE: if home is a single wide fill out one half of the blocking plan
if home is a triple or quad wide sketch in remainder of home
szoo
I understand Lateral Arm Systems can?i Qn any home (new or used)
Where the sidewall ties exceed 5 ftlpj b1Z odb
N� Sbp �r�f
Typical pier spacing 401"
;Z1d 03, p� NfO ��� � bl 0o
T I lateral ®dobd �; �b
Show locatio' &%%.j1H&h§nd Lateral Systems
1=911.dinal (use dark lines, to s kese location
■ i i i i i i i i
■■■■■■■■■■■■■■■■■■■■■■■■■■■■
NOON■■
■■■■■■■■■■■■■■■■■■■NONE
■■■■■■■NOON■■■
■NEE■■■■■■■®E.E■NEE■®■N■®0■®®®®®
iE■
■■E
EEOE■■®EEE©®
E■®E■N
Elm
ME■min
IVEME
MEN
■■■■
E
��■■EEE�1N®®E®■®®®■®OE®EELI■■■■E
:■■
...■■■■■■■■■■::N:::C:::■■:::■MEN
:::■
No
M
0
ME
M
�E■EEE�■■■■■■p■■EEEEEE■E■E■■NEE■■■
■
�O■E■
■■E
■NEE■■■E■■■■NE
■NOO■NEO■E■■■■■■■■■■■■■EEEOE■E■■EN■■■■ENE■■
■N■
■
PERMIT WORKSHEET
I PL190 1 0. 2
New Home [] Used Home Ql
Home installed to the Manufacturer's Installation Manual
Home is installed in accordance with Rule 15-C
Single wide El Wind Zone II
Wind Zone III
©out le wideIR Installation Decal # -7
Triple/Quad El Serial # ;Z 0
PIER SPACING TABLE FOR I ISFn Nnee=c
Load
Footer
bearing
size
16' x 16'
18 1/2' x 18 1/2'
20' x 20-
22' x 22'
24' X 24-
26- x 26'
capacity
(sq in)
(256)
(342)
(400)
'(484)'
(576)'
(676)
1000 s
3
4
5
g
1500 ps
4 6
6
78.8
2000 s
6
8
8
8
2500 psf
7 6
8
8
8
8
8
3000 esf
8
g
8
8
8
3500 s
� infarnnlnlcr7 /•.,...
8
O•1„ iGr
8
8
8
PIER PAD SIZES
I-beam pier pad size (�
Perimeter pier pad size
Other pier pad sizes 16
(required by the mfg.)
Draw_ the approximate locations of marriage
wall openings 4 foot or greater. Use this
symbol to show the piers.'
List all marriage wall openings greater than 4 foot
and their pier pad sizes below.
Opening Pier pad size
TIEDOWN COMPONENTS
Longitudinal Stabilizing Device LSD)
Manufacturer OL
Longitudinal Stabilizing Device w/Lateral Arms
Manufacturer
POPULAR PAD SIZES
ANCHORS
4 ft ;J 5 It
FRAME TIES
within 2' of end of horge
spaced at 5' 4" oc is
OTHER TIES
Number
Sidewall
Longitudinal
Marriaqe wall
Shearwal l
PLHMI l WORKSHEET page 2 0( 2
E<EF;MIT NUMBER
POCKET PENETROMETER TEST,z:
The pocket penetrometer tests are rounded dpwn to psf
or check here to declare 1000 Ib. soil i.! wlthoul testing.
X. X X
POCKET PENETROMETER TESTING METHOD
1. Test the perimeter of the home at 6 locations.
2. Take the reading at the depth of the Tooter.
3. Using 500 lb. increments, take the lowest
reading and round down to that increment.
X X
TORQUE PROBE TEST
X
The results of the torque probe test is — inch pounds or check
here if you are declaring 5' anchors without testing . A test _
showing 275 inch pounds or less will require 5 foot anchors,
Note: A state approved lateral arm system is being used and 4 ft.
anchors are allowed at the sidewall locations. I understand 5 ft
anchors are required at all centerline tie points where the torque test
reading is 275 or less and where the mobile home manufacturer may
requires anchors with 4000 I capacity.
Installer's initials
ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER
Installer Name��(/J
• r
Date Tested
v 1 „/ —
connect _electrical conductors between multi -wide units, but not to the mai er
;ource. This includes the bonding wire between mult-wide units. Pg.
Plumbina
;onnect all sewer drains to an existing sewer tap or septic tank. Pg.
,onnect all potable water supply piping to an axis •nq water meter, water tap, or other
idependent water supply systems. Pg.
Site Preparation
Debris and organic material rerpoved
Water drainage: Natural Swale Pad Other
Fastening multi wide units
Floor: Type Fastener: 16 r� _ength: ! �� Spacing: _ !�
Walls: Type Fastener: Length: Spacing:
Roof: Type Fastener: �L Length: � Spacing:
For used homes a min. 30 gauge, 8" wide, galvanized metal strip
will be centered over the peak of the roof and fastened with galy.
roofing nails at 2" on center on both sides of the centerline.
Gasket (weatherproofing requirement)
I understand a properly installed gasket is a requirement of all new and used
homes and that condensation, mold, meldew and buckled marriage walls are
a result of a poorly installed or no gasket being installed. I understand a strip
of tape will not serve as a gasket.
/ Installer's initials
Type gasket ,P` v^A"" Installed: /
Pg. Between Floors Yes
Between Walls Yes
Bottom of ridqebeam Yes
Weatherproofing /
The bottomboard will be repaired and/or taped. Yes woo/
• PC).
Siding on units is installed to manufacturer's specifications. Yes
—
Fireplace chimney installed so as not to allow intrusion of rain water.._Yes. _
Miscellaneous
Skirting to be installed. Yes No
Dryer vent installed outside of skirting. Yeses N/A
Range downf low vent installed outside of skirting. Xes
Drain lines supported at 4 foot intervals. Yeses (/
'%l trical crossovers protected. Yes ✓
HMO er
Installer verifies all information given with this permit workshee_t
is accurate and true based on the
Installer Signature