Loading...
HomeMy WebLinkAboutLetter; Certification for Handbill Retrofit of Existing StairsFROM: STEVENS. WOOD, P.E. PROFESSIONAL ENGINEER FL PE RES. NO. 34398 950 SULTAN DR PSL, FL 34953 TO: ST. LUCIE COUNTY BUILDING DEPT. 2300 VIRGINIA AVE FT. PIERCE, FL 34982 MARCH 22, 2008 SUBJECT: CERTIFICATION FOR HANDRAIL RETROFIT OF EXISTING STAIRS REF: COLONY CLUB MOBILE HOME PARK ;/, j�A�T; ` O 0 — 0 °' OWNER/MANAGER: HOWARD FINE 2601 US 1 FORT PIERCE, FL THE PURPOSE OF THIS LETTER IS TO CERTIFY THE RETROFIT OF DUAL WOODEN HAND/GUARD RAILS TO EXISTING FIBERGLASS/WOODEN STAIRS AT THE ABOVE REFERENCED ADDRESS. THE MOBILE PARK HAS SEVERAL SETS OF EXISTING STAIRS (WITH 2 TO 5 STEPS) WHICH ORIGINALLY HAD EITHER NO HANDRAILS OR A SINGLE HANDRAIL OR AN ALUMINUM SINGLE HAI DRAIL. THIS ENGINEER CONDUCTED AN INSPECTION OF A RETROFIT SET OF STAIRS ON 3/22/08 WHICH HAD BEEN CONSTRUCTED AS A PROTOTYPE USING 2"x4" UPRIGHTS AND CAPS AND 1"x2" PICKETS. BASED ON THE INSPECTION AND DISCUSSIONS WITH MR FINE, THE FOLLOWING FINDINGS WERE MADE: • THE EXISTING WOODEN/FIBERGLASS STAIRS APPEARED TO BE IN GOOD CONDITION AND CONSTRUCTED ADEQUETLY TO ACCEPT THE NEW GUARDRAILS. • THE STAIRS ARE APPROX 4' WIDE WITH THE NEW WOOD GUARD RAILS ON BOTH SIDES. - THE NEW WOOD GUARDRAILS ARE AT THE PROPER HEIGHT AND MEET THE 4" MIN GAP REQUIREMENT BETWEEN PICKETS AS REQUIRED BY CODE. • THE WOOD MEMBERS OF THE NEW GUARDRAIL ARE ATTACHED TO THE WOOD STAIRS USING 3" WOOD DECK SCREWS AT 6"-12" ON CENTER. • THE FINISHED RETROFIT GUARDRAILS MEET OR EXCEED STRUCTURAL REQUIREMENTS AND RESULT IN AN IMPROVED SYSTEM OVER THE ALUMINUM GUARDRAIL SYSTEM. BASED ON THE FINDINGS, THE RETROFI OODEN GUAlt ON EXISTING STAIRS IS IN COMPL ANCE WITH THE 2 SUPPLEMENTS) AND IS THEREFORE CCEPTABLE AS IS. cam/ 10 0 IL SYSTEM INSTALLED E C (INCLUDING ALL 31..2a1n&