Loading...
HomeMy WebLinkAboutAPPROVED Gulfcoast 1 snap4/13/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtcpgfIynXQVdmda12NzCFrvwxqa1rDe5JEWw%2fIDlCxxw%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL33818 Application Type New Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Gulf Coast Supply & Manufacturing, LLC. Address/Phone/Email 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352) 498-0778 Ext 0565 jared.pearce@gulfcoastsupply.com Authorized Signature Jared Pearce jared.pearce@gulfcoastsupply.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2023 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL33818_R0_COI_GCS20002a 2020 FBC Eval Metal Roofing NonHVHZ final.pdf Referenced Standard and Year (of Standard)Standard Year ASTM B 117 2016 ASTM G 155 2013 FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By REVISION 4/13/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtcpgfIynXQVdmda12NzCFrvwxqa1rDe5JEWw%2fIDlCxxw%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/11/2020 Date Validated 10/31/2020 Date Pending FBC Approval 11/05/2020 Date Approved 12/16/2020 Summary of Products FL #Model, Number or Name Description 33818.1 Metal Roofing Systems (HVHZ)GulfLok, VersaLoc, 5V Crimp, GulfPBR and GulfRib Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +0/-164.25 Other: See evaluation report for limits of use. Installation Instructions FL33818_R0_II_GCS20002b 2020 FBC Eval Metal Roofing HVHZ final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL33818_R0_AE_GCS20002b 2020 FBC Eval Metal Roofing HVHZ final.pdf Created by Independent Third Party: Yes 33818.2 Metal Roofing Systems (nonHVHZ)GulfLok, GulfSeam, MegaLoc, VersaLoc, 5V Crimp, GulfPBR, GulfRib and GulfWave Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-164.25 Other: See evaluation report for limits of use. Installation Instructions FL33818_R0_II_GCS20002a 2020 FBC Eval Metal Roofing NonHVHZ final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL33818_R0_AE_GCS20002a 2020 FBC Eval Metal Roofing NonHVHZ final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a CREEK Technical Services, LLC GCS20002a FL33818 Page 1 of 6 Page 1 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: GULF COAST SUPPLY & MANUFACTURING, LLC Issued October 22, 2020 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 (352) 498-7852 www.gulfcoastsupply.com Manufacturing Locations: Alachua, FL Sebring, FL Montgomery, AL Quality Assurance: Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Force Engineering & Testing (TST5328) 72-0313T-06A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 72-0198T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0033T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0053T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07D-F UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07G-I UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07J-K UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0065T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0076T-12A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0089T-05.1 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0089T-05.2 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0102T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0165T-11B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0238T-09D FM 4471 1992 Force Engineering & Testing (TST5328) 117-0238T-09E FM 4471 1992 Force Engineering & Testing (TST5328) 117-0238T-11A FM 4471 1992 Force Engineering & Testing (TST5328) 117-0248T-07A,B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0284T-09A UL 580 UL 1897 2006 2012 A CREEK Technical Services, LLC GCS20002a FL33818 Page 2 of 6 Page 2 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing Entity Report No. Standard Year Force Engineering & Testing (TST5328) 117-0285T-09A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0301T-10A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0330T-10A-B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08D UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0337T-10 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0378T-11A FM 4471 1992 Force Engineering & Testing (TST5328) 117-0378T-11B FM 4471 1992 Force Engineering & Testing (TST5328) 117-0378T-11C FM 4471 1992 Force Engineering & Testing (TST5328) 117-0407T-09 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0407T-09A UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) B9000.01-450-18 UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) C0308.01-450-18 UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) D0818.01-450-18 UL 580 2006 Intertek- West Palm Beach (an ATI company) (TST1527) D1692.01-450-44 UL 580 UL 1897 ASTM E 8 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) G7287.01-450-44 UL 580 2006 PRI Construction Materials Technologies (TST5878) 1272T0005 ASTM G 155 2013 A CREEK Technical Services, LLC GCS20002a FL33818 Page 3 of 6 Page 3 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing PRODUCT DESCRIPTION GulfLok Profile: 1 in. snap lock seam; Max.16 in. coverage Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 24 ksi; Shall conform with FBC Section 1507.4.3 GulfSeam Profile: 1 3/4 in. snap lock seam; Max. 18 in. coverage Description: Non-structural, snap lock standing seam roof panel Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032-inch ASTM B209, 3105 H24 aluminum, Optional Fluropon® paint finish; Fy = min. 21 ksi; Shall conform with FBC Section 1507.4.3 MegaLoc Profile: 2 in. mechanical seam; Max. 18 in. coverage Description: Non-structural, mechanical lock 180º standing seam roof panel Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC GCS20002a FL33818 Page 4 of 6 Page 4 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing VersaLoc Profile: 1.5 in. mechanical seam; Max. 18 in. coverage Description: Non-structural, mechanical lock 180º standing seam roof panel Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 5V Crimp Profile: 7/16 in. ribs at 12 in. o.c.; 24 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 25 ksi; Shall conform with FBC Section 1507.4.3 GulfPBR Profile: 1 1/4 in. ribs at 12 in. o.c.; 36 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC GCS20002a FL33818 Page 5 of 6 Page 5 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing GulfRib Profile: 3/4 in. ribs at 9 in. o.c.; 36 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3 GulfWave Profile: 3/4 in. corrugation; 29 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC GCS20002a FL33818 Page 6 of 6 Page 6 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing LIMITATIONS 1.Fire classification is not within the scope of this evaluation. 2.This report is not for use in the HVHZ. 3.The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4.Roof slope shall be in accordance with FBC Section 1507.4.2. 5.Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated in accordance with FBC Section 1511.3. 6.Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7.All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products und er this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1)APPENDIX A – Installation (5 pages) 2)APPENDIX B – Approved Roof Systems (7 pages) 3)APPENDIX C – Design Wind Loads (4 pages) 2020.10.22 15:51:16 -04'00' A CREEK Technical Services, LLC GCS20002a FL33818 Page 1 of 5 Page 1 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A INSTALLATION Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners #9-15 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion resistant in accordance with FBC section 1507.4.4. #9-15 HWH WoodZAC screw #10-12 Pancake Type A screw #12-11 Pancake Type A screw #12-8 HWH Woodgrip XG screw with sealing washer 1/4-14 HWH ZAC Impax Lap screw Installed at panel side lap; Shall be corrosion resistant in accordance with FBC section 1507.4.4. Clips GulfLok Clip 24 ga. in-seam clip Fixed Clip 18 ga. in-seam clip A CREEK Technical Services, LLC GCS20002a FL33818 Page 2 of 5 Page 2 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Component Product Installation Detail Clips (Cont’d) NC-33003-3 Sliding Clip 1500SC Sliding Clip 22 ga. top; 16 ga. base; in-seam clip Sealants TiteBond Weathermaster Metal Roof Sealant Shall be applied in 1/4”- 5/16” continuous beads on the male rib along the seam Fastening Details Nomenclature Attachment GulfLok Type 1 GulfLok Overlap A CREEK Technical Services, LLC GCS20002a FL33818 Page 3 of 5 Page 3 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Fastening Details Nomenclature Attachment GulfLok Type 2 GulfSeam Type 1 MegaLoc Type 1 VersaLoc Type 1 5V Type 1 5V Type 2 A CREEK Technical Services, LLC GCS20002a FL33818 Page 4 of 5 Page 4 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Fastening Details Nomenclature Attachment 5V Type 3 GulfPBR Type 1 GulfPBR Type 2 GulfRib Type 1 GulfRib Type 2 A CREEK Technical Services, LLC GCS20002a FL33818 Page 5 of 5 Page 5 of 22 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Fastening Details Nomenclature Attachment GulfRib Type 3 GulfRib Type 4 GulfWave Type 1 A CREEK Technical Services, LLC GCS20002a FL33818 Page 1 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. The panel thickness or gauge is the minimum allowable. 6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood sheathing at maximum 24-inch span. Roof System Numbers and Definitions LOK-W# GulfLok over Wood Deck (New or Existing) SEAM-W# GulfSeam over Wood Deck (New or Existing) MEGA-W # MegaLoc over Wood Deck (New or Existing) VL-W# 1.5” VersaLoc over Wood Deck (new or Existing) 5V-W# 5V Crimp over Wood Deck (New or Existing) PBR-W# GulfPBR over Wood Deck (New or Existing) RIB-W# GulfRib over Wood Deck (New or Existing) WAVE-W # GulfWave over Wood Deck (New or Existing) Approved Systems for GulfLok over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) LOK-W-1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC 26 ga., Grade 80 GulfLok Max. 16-inch coverage GulfLok Type 1 attachment #10-12 x 1” Pancake Type A p screws spaced 5-3/16 in. o.c -63.5 LOK-W-2 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. -65.5 LOK-W-3 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 10-1/4 in. o.c. -81.75 LOK-W-4 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-1/8 in. o.c. -96.75 A CREEK Technical Services, LLC GCS20002a FL33818 Page 2 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for GulfLok over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) LOK-W-5 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. Titebond Weathermaster Metal Roof Sealant applied to male rib. -116 LOK-W-6 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. Titebond Weathermaster Metal Roof Sealant applied to male rib. -121.75 LOK-W-7 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC 26 ga., Grade 80 GulfLok Max. 16-inch coverage GulfLok Type 2 attachment with #10-12 x 1” Pancake Type A screws through clip and spaced 5-3/16 in. o.c. -161 Approved Systems for GulfSeam over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) SEAM-W-1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 24 in. o.c. -69.25 SEAM-W-3 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 18 in. o.c. -86 SEAM-W-4 Min. 1x4 No. 2 SYP wood purlins spaced 18 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with clips spaced 18 in. o.c. over wood purlins -93.5 SEAM-W-5 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 12 in. o.c. -108.5 A CREEK Technical Services, LLC GCS20002a FL33818 Page 3 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for GulfSeam over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) SEAM-W-6 Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 24 in. o.c. over wood purlins -114.25 SEAM-W-7 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 6 in. o.c. -138.5 SEAM-W-8 Min. 1x4 No. 2 SYP wood purlins spaced 12 in. o.c. over Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 12 in. o.c. over wood purlins -159.25 Approved Systems for MegaLoc over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) MEGA-W -1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. MegaLoc Max. 18-inch coverage MegaLocType 1 attachment with clips spaced 24 in. o.c. -71 MEGA-W -2 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. MegaLoc Max. 18-inch coverage MegaLocType 1 attachment with clips spaced 12 in. o.c. -108.5 A CREEK Technical Services, LLC GCS20002a FL33818 Page 4 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for VersaLoc over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) VL-W-1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. VersaLoc Max. 16-inch coverage VersaLoc Type 1 attachment with clips spaced 24 in. o.c. -59.75 VL-W-2 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. VersaLoc Max. 16-inch coverage VersaLoc Type 1 attachment with clips spaced 6 in. o.c. -123.5 Approved Systems for 5V Crimp over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) 5V-W1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 3 attachment with #9-15 HWH wood screws with sealing washers spaced 16 in. o.c. -94.25 5V-W2 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al or Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -108.5 5V-W3 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 2 attachment with #9-15 HWH wood screws with sealing washers spaced 16 in. o.c. -131 5V-W4 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 6 in. o.c. -156.5 A CREEK Technical Services, LLC GCS20002a FL33818 Page 5 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for GulfPBR over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) PBR-W-1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage GulfPBR Type 1 attachment with #9-15 15 HWH WoodZAC screws spaced 24 in. o.c. Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap screws spaced 24 in. o.c. -60.5 PBR-W-2 Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage GulfPBR Type 1 attachment with #9-15 HWH WoodZAC screws spaced 24 in. o.c. into wood purlins Laps fastened with 1/4-14 x 7/8 ZAC Impax Lap screws spaced 24 in. o.c. -100.5 PBR-W-3 Min. 1x4 No. 2 SYP wood purlins spaced 12 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage GulfPBR Type 2 attachment with #9-15 15 HWH WoodZAC screws spaced 12 in. o.c. into wood purlins Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap screws spaced 24 in. o.c. -151.75 PBR-W-4 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage GulfPBR Type 2 attachment with #9-15 HWH WoodZAC screws spaced 12 in. o.c. Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap screws spaced 24 in. o.c. -154.75 Approved Systems for GulfRib over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) RIB-W-1 Min. 7/16 OSB OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 4 attachment with #12-8 HWH Woodgrip XG wood screws with sealing washers spaced 24 in. o.c. -22.66 RIB-W-2 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 3 attachment with #9-15 HWH wood screws with sealing washers spaced 24 in. o.c. -56 A CREEK Technical Services, LLC GCS20002a FL33818 Page 6 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for GulfRib over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) RIB-W-3 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with # with #9-15 HWH WoodZAC screws spaced 24 in. o.c -71.75 RIB-W-4 Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with #9-15 x 1 1/2” HWH wood screws with sealing washers spaced 24 in. o.c. into wood purlins -76.75 RIB-W-5 Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 7/16 OSB OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with #9-15 x 1 1/2” HWH wood screws with sealing washers spaced 24 in. o.c. into wood purlins -101 RIB-W-6 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 3 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -101 RIB-W-7 Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with #9-15 HWH WoodZAC screws spaced 24 in. o.c. into wood purlins -106.75 RIB-W-8 Min. 7/16 OSB OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 4 attachment with #12-8 HWH Woodgrip XG wood screws with sealing washers spaced 6 in. o.c. -116.0 A CREEK Technical Services, LLC GCS20002a FL33818 Page 7 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for GulfRib over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) RIB-W-9 Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 2 attachment with #9-15 x 1 1/2” HWH wood screws with sealing washers spaced 24 in. o.c. into wood purlins -123.5 RIB-W-10 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 2 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -146.0 RIB-W-11 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfRib 36-inch coverage GulfRib Type 2 attachment with #9-15 HWH WoodZAC screws spaced 12 in. o.c. -159.25 RIB-W-12 Min. 1x4 No. 2 SYP wood purlins spaced 12 in. o.c. over Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with #9-15 HWH WoodZAC screws spaced 12 in. o.c. into wood purlins -164.25 Approved Systems for GulfWave over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) WAVE-W1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfWave 29-inch coverage GulfWave Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 24 in. o.c. -78.5 A CREEK Technical Services, LLC GCS20002a FL33818 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd = 0.85 8. Vult is shown in the tables below. Design wind loads are calculated using Vasd = Vult√0.6 per 1609.3.1. 9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3ft Gable Hip . a a a 3 3 a 2 2 1 2 3 a 3 2 a 3 2 2 3 3 1 2 2 3 a a a a a 3 3 2 2 1 1 2 2 1 a 2 2 1 3 3 A CREEK Technical Services, LLC GCS20002a FL33818 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX C Gable/Hip Roofs in Exposure B (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6 25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7 40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5 50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2 60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8 2 20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0 25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2 50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 3 20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4 25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2 40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0 50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9 60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8 Partially Enclosed 1 20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6 25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2 40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2 50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9 60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2 2 20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0 25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9 50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2 60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6 3 20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4 25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7 40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7 50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6 60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2 A CREEK Technical Services, LLC GCS20002a FL33818 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX C Gable/Hip Roofs in Exposure C (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5 25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6 40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4 50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1 60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7 2 20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5 25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7 50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0 60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7 3 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5 40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3 50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2 60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1 Partially Enclosed 1 20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9 25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5 40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5 50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2 60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5 2 20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9 25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8 50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1 60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5 3 20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1 25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4 40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4 50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2 60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9 A CREEK Technical Services, LLC GCS20002a FL33818 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX C Gable/Hip Roofs in Exposure D (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0 25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1 40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9 50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6 60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1 2 20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4 25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6 50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9 60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6 3 20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2 25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0 40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8 50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7 60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6 Partially Enclosed 1 20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8 25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5 40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5 50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1 60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5 2 20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2 25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2 50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5 60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9 3 20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1 25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4 40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4 50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2 60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9