HomeMy WebLinkAboutAPPROVED Gulfcoast 1 snap4/13/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtcpgfIynXQVdmda12NzCFrvwxqa1rDe5JEWw%2fIDlCxxw%3d%3d 1/2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL33818
Application Type New
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778 Ext 0565
jared.pearce@gulfcoastsupply.com
Authorized Signature Jared Pearce
jared.pearce@gulfcoastsupply.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL33818_R0_COI_GCS20002a 2020 FBC Eval Metal Roofing NonHVHZ
final.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM B 117 2016
ASTM G 155 2013
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
REVISION
4/13/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtcpgfIynXQVdmda12NzCFrvwxqa1rDe5JEWw%2fIDlCxxw%3d%3d 2/2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/11/2020
Date Validated 10/31/2020
Date Pending FBC Approval 11/05/2020
Date Approved 12/16/2020
Summary of Products
FL #Model, Number or Name Description
33818.1 Metal Roofing Systems (HVHZ)GulfLok, VersaLoc, 5V Crimp, GulfPBR and GulfRib
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: +0/-164.25
Other: See evaluation report for limits of use.
Installation Instructions
FL33818_R0_II_GCS20002b 2020 FBC Eval Metal Roofing
HVHZ final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL33818_R0_AE_GCS20002b 2020 FBC Eval Metal Roofing
HVHZ final.pdf
Created by Independent Third Party: Yes
33818.2 Metal Roofing Systems (nonHVHZ)GulfLok, GulfSeam, MegaLoc, VersaLoc, 5V Crimp, GulfPBR,
GulfRib and GulfWave
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-164.25
Other: See evaluation report for limits of use.
Installation Instructions
FL33818_R0_II_GCS20002a 2020 FBC Eval Metal Roofing
NonHVHZ final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL33818_R0_AE_GCS20002a 2020 FBC Eval Metal Roofing
NonHVHZ final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
a CREEK
Technical Services, LLC
GCS20002a FL33818 Page 1 of 6 Page 1 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020)
Manufacturer: GULF COAST SUPPLY & MANUFACTURING, LLC Issued October 22, 2020
14429 SW 2nd Place, Suite G30
Newberry, FL 32669
(352) 498-7852
www.gulfcoastsupply.com
Manufacturing Locations: Alachua, FL
Sebring, FL
Montgomery, AL
Quality Assurance: Keystone Certifications, Inc. (QUA1824)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Force Engineering & Testing (TST5328) 72-0313T-06A-C UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 72-0198T-07A-C UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0033T-05 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0053T-05 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0062T-07A-C UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0062T-07D-F UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0062T-07G-I UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0062T-07J-K UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0065T-07A-C UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0076T-12A UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0089T-05.1 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0089T-05.2 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0102T-05 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0165T-11B UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0238T-09D FM 4471 1992
Force Engineering & Testing (TST5328) 117-0238T-09E FM 4471 1992
Force Engineering & Testing (TST5328) 117-0238T-11A FM 4471 1992
Force Engineering & Testing (TST5328) 117-0248T-07A,B UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0284T-09A UL 580
UL 1897
2006
2012
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 2 of 6 Page 2 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
Entity Report No. Standard Year
Force Engineering & Testing (TST5328) 117-0285T-09A UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0301T-10A-C UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0330T-10A-B UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0331T-08A UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0331T-08B UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0331T-08D UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0337T-10 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0378T-11A FM 4471 1992
Force Engineering & Testing (TST5328) 117-0378T-11B FM 4471 1992
Force Engineering & Testing (TST5328) 117-0378T-11C FM 4471 1992
Force Engineering & Testing (TST5328) 117-0407T-09 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 117-0407T-09A UL 580
UL 1897
2006
2012
Intertek- West Palm Beach (an ATI company) (TST1527) B9000.01-450-18 UL 580
UL 1897
2006
2012
Intertek- West Palm Beach (an ATI company) (TST1527) C0308.01-450-18 UL 580
UL 1897
2006
2012
Intertek- West Palm Beach (an ATI company) (TST1527) D0818.01-450-18 UL 580 2006
Intertek- West Palm Beach (an ATI company) (TST1527) D1692.01-450-44 UL 580
UL 1897
ASTM E 8
2006
2012
Intertek- West Palm Beach (an ATI company) (TST1527) G7287.01-450-44 UL 580 2006
PRI Construction Materials Technologies (TST5878) 1272T0005 ASTM G 155 2013
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 3 of 6 Page 3 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
PRODUCT DESCRIPTION
GulfLok Profile: 1 in. snap lock seam; Max.16 in. coverage
Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish;
Fy = min. 24 ksi; Shall conform with FBC Section 1507.4.3
GulfSeam Profile: 1 3/4 in. snap lock seam; Max. 18 in. coverage
Description: Non-structural, snap lock standing seam roof panel
Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032-inch ASTM B209, 3105 H24 aluminum, Optional Fluropon® paint finish;
Fy = min. 21 ksi; Shall conform with FBC Section 1507.4.3
MegaLoc Profile: 2 in. mechanical seam; Max. 18 in. coverage
Description: Non-structural, mechanical lock 180º standing seam roof panel
Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 4 of 6 Page 4 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
VersaLoc Profile: 1.5 in. mechanical seam; Max. 18 in. coverage
Description: Non-structural, mechanical lock 180º standing seam roof panel
Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
5V Crimp Profile: 7/16 in. ribs at 12 in. o.c.; 24 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish;
Fy = min. 25 ksi; Shall conform with FBC Section 1507.4.3
GulfPBR Profile: 1 1/4 in. ribs at 12 in. o.c.; 36 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 5 of 6 Page 5 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
GulfRib Profile: 3/4 in. ribs at 9 in. o.c.; 36 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3
GulfWave Profile: 3/4 in. corrugation; 29 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint
finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 6 of 6 Page 6 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
LIMITATIONS
1.Fire classification is not within the scope of this evaluation.
2.This report is not for use in the HVHZ.
3.The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4.Roof slope shall be in accordance with FBC Section 1507.4.2.
5.Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated
in accordance with FBC Section 1511.3.
6.Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7.All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products und er
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1)APPENDIX A – Installation (5 pages)
2)APPENDIX B – Approved Roof Systems (7 pages)
3)APPENDIX C – Design Wind Loads (4 pages)
2020.10.22
15:51:16
-04'00'
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 1 of 5 Page 1 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX A
INSTALLATION
Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
Fasteners
#9-15 HWH wood screw
with sealing washer
Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion
resistant in accordance with FBC section 1507.4.4.
#9-15 HWH WoodZAC
screw
#10-12 Pancake Type A
screw
#12-11 Pancake Type A
screw
#12-8 HWH Woodgrip
XG screw with sealing
washer
1/4-14 HWH ZAC Impax
Lap screw
Installed at panel side lap; Shall be corrosion resistant in accordance with FBC
section 1507.4.4.
Clips
GulfLok Clip
24 ga. in-seam clip
Fixed Clip
18 ga. in-seam clip
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 2 of 5 Page 2 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX A
Component Product Installation Detail
Clips (Cont’d)
NC-33003-3 Sliding Clip
1500SC Sliding Clip
22 ga. top; 16 ga. base; in-seam clip
Sealants TiteBond Weathermaster
Metal Roof Sealant Shall be applied in 1/4”- 5/16” continuous beads on the male rib along the seam
Fastening Details
Nomenclature Attachment
GulfLok Type 1
GulfLok Overlap
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 3 of 5 Page 3 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
GulfLok Type 2
GulfSeam Type 1
MegaLoc Type 1
VersaLoc Type 1
5V Type 1
5V Type 2
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 4 of 5 Page 4 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
5V Type 3
GulfPBR Type 1
GulfPBR Type 2
GulfRib Type 1
GulfRib Type 2
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 5 of 5 Page 5 of 22
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
GulfRib Type 3
GulfRib Type 4
GulfWave Type 1
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 1 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. The panel thickness or gauge is the minimum allowable.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0 & FBC.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
LOK-W# GulfLok over Wood Deck (New or Existing)
SEAM-W# GulfSeam over Wood Deck (New or Existing)
MEGA-W # MegaLoc over Wood Deck (New or Existing)
VL-W# 1.5” VersaLoc over Wood Deck (new or Existing)
5V-W# 5V Crimp over Wood Deck (New or Existing)
PBR-W# GulfPBR over Wood Deck (New or Existing)
RIB-W# GulfRib over Wood Deck (New or Existing)
WAVE-W # GulfWave over Wood Deck (New or Existing)
Approved Systems for GulfLok over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
LOK-W-1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC 26 ga., Grade 80 GulfLok
Max. 16-inch coverage GulfLok Type 1 attachment #10-12 x 1”
Pancake Type A p screws spaced 5-3/16 in. o.c -63.5
LOK-W-2 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 0.032” Al GulfLok
Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1”
Pancake Type A screws spaced 5-3/16 in. o.c. -65.5
LOK-W-3 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC 24 ga. GulfLok
Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1”
Pancake Type A screws spaced 10-1/4 in. o.c. -81.75
LOK-W-4 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC 24 ga. GulfLok
Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1”
Pancake Type A screws spaced 5-1/8 in. o.c. -96.75
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 2 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
Approved Systems for GulfLok over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
LOK-W-5 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 0.032” Al GulfLok
Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1”
Pancake Type A screws spaced 5-3/16 in. o.c.
Titebond Weathermaster Metal Roof Sealant
applied to male rib.
-116
LOK-W-6 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfLok
Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1”
Pancake Type A screws spaced 5-3/16 in. o.c.
Titebond Weathermaster Metal Roof Sealant
applied to male rib.
-121.75
LOK-W-7 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC 26 ga., Grade 80 GulfLok
Max. 16-inch coverage
GulfLok Type 2 attachment with
#10-12 x 1” Pancake Type A screws through
clip and spaced 5-3/16 in. o.c.
-161
Approved Systems for GulfSeam over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
SEAM-W-1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. GulfSeam
Max. 18-inch coverage
GulfSeam Type 1 attachment
with clips spaced 24 in. o.c. -69.25
SEAM-W-3 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 0.032” Al GulfSeam
Max. 18-inch coverage
GulfSeam Type 1 attachment
with stainless steel clips spaced 18 in. o.c. -86
SEAM-W-4
Min. 1x4 No. 2
SYP wood
purlins spaced
18 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. GulfSeam
Max. 16-inch coverage
GulfSeam Type 1 attachment with clips spaced
18 in. o.c. over wood purlins -93.5
SEAM-W-5 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. GulfSeam
Max. 18-inch coverage
GulfSeam Type 1 attachment
with clips spaced 12 in. o.c. -108.5
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 3 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
Approved Systems for GulfSeam over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
SEAM-W-6
Min. 1x4 No. 2
SYP wood
purlins spaced
24 in. o.c.
over
Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. GulfSeam
Max. 18-inch coverage
GulfSeam Type 1 attachment with clips spaced
24 in. o.c. over wood purlins -114.25
SEAM-W-7 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 0.032” Al GulfSeam
Max. 16-inch coverage
GulfSeam Type 1 attachment
with stainless steel clips spaced 6 in. o.c. -138.5
SEAM-W-8
Min. 1x4 No. 2
SYP wood
purlins spaced
12 in. o.c.
over
Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. GulfSeam
Max. 18-inch coverage
GulfSeam Type 1 attachment with clips spaced
12 in. o.c. over wood purlins -159.25
Approved Systems for MegaLoc over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
MEGA-W -1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. MegaLoc
Max. 18-inch coverage
MegaLocType 1 attachment
with clips spaced 24 in. o.c. -71
MEGA-W -2 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. MegaLoc
Max. 18-inch coverage
MegaLocType 1 attachment
with clips spaced 12 in. o.c. -108.5
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 4 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
Approved Systems for VersaLoc over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
VL-W-1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. VersaLoc
Max. 16-inch coverage
VersaLoc Type 1 attachment
with clips spaced 24 in. o.c. -59.75
VL-W-2 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 24 ga. VersaLoc
Max. 16-inch coverage
VersaLoc Type 1 attachment
with clips spaced 6 in. o.c. -123.5
Approved Systems for 5V Crimp over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
5V-W1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. 5V Crimp
24-inch coverage 5V Crimp Type 3 attachment with #9-15 HWH wood
screws with sealing washers spaced 16 in. o.c. -94.25
5V-W2 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 0.032” Al or
Min. 26 ga. 5V Crimp
24-inch coverage
5V Crimp Type 1 attachment with #9-15 HWH wood
screws with sealing washers spaced 12 in. o.c. -108.5
5V-W3 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC Min. 26 ga. 5V Crimp
24-inch coverage
5V Crimp Type 2 attachment with #9-15 HWH wood
screws with sealing washers spaced 16 in. o.c. -131
5V-W4 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. 5V Crimp
24-inch coverage
5V Crimp Type 1 attachment with
#9-15 HWH wood screws with sealing washers spaced 6
in. o.c. -156.5
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 5 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
Approved Systems for GulfPBR over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
PBR-W-1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfPBR
36-inch coverage
GulfPBR Type 1 attachment with #9-15 15 HWH WoodZAC
screws spaced 24 in. o.c.
Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap
screws spaced 24 in. o.c.
-60.5
PBR-W-2
Min. 1x4 No. 2
SYP wood
purlins spaced
24 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfPBR
36-inch coverage
GulfPBR Type 1 attachment with #9-15 HWH WoodZAC
screws spaced 24 in. o.c. into wood purlins
Laps fastened with 1/4-14 x 7/8 ZAC Impax Lap screws
spaced 24 in. o.c.
-100.5
PBR-W-3
Min. 1x4 No. 2
SYP wood
purlins spaced
12 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfPBR
36-inch coverage
GulfPBR Type 2 attachment with #9-15 15 HWH
WoodZAC screws spaced 12 in. o.c. into wood purlins
Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap
screws spaced 24 in. o.c.
-151.75
PBR-W-4 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfPBR
36-inch coverage
GulfPBR Type 2 attachment with #9-15 HWH WoodZAC
screws spaced 12 in. o.c.
Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap
screws spaced 24 in. o.c.
-154.75
Approved Systems for GulfRib over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
RIB-W-1 Min. 7/16 OSB OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage GulfRib Type 4 attachment with #12-8 HWH Woodgrip XG
wood screws with sealing washers spaced 24 in. o.c. -22.66
RIB-W-2 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage GulfRib Type 3 attachment with #9-15 HWH wood screws
with sealing washers spaced 24 in. o.c. -56
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 6 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
Approved Systems for GulfRib over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
RIB-W-3 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage GulfRib Type 1 attachment with # with #9-15 HWH
WoodZAC screws spaced 24 in. o.c -71.75
RIB-W-4
Min. 1x4 No. 2
SYP wood
purlins spaced
24 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage
GulfRib Type 1 attachment with #9-15 x 1 1/2” HWH wood
screws with sealing washers spaced 24 in. o.c.
into wood purlins
-76.75
RIB-W-5
Min. 1x4 No. 2
SYP wood
purlins spaced
24 in. o.c.
over
Min. 7/16 OSB
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage
GulfRib Type 1 attachment with #9-15 x 1 1/2” HWH wood
screws with sealing washers spaced 24 in. o.c.
into wood purlins
-101
RIB-W-6 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage GulfRib Type 3 attachment with #9-15 HWH wood screws
with sealing washers spaced 12 in. o.c. -101
RIB-W-7
Min. 1x4 No. 2
SYP wood
purlins spaced
24 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfRib
36-inch coverage GulfRib Type 1 attachment with #9-15 HWH WoodZAC
screws spaced 24 in. o.c. into wood purlins -106.75
RIB-W-8 Min. 7/16 OSB OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage GulfRib Type 4 attachment with #12-8 HWH Woodgrip XG
wood screws with sealing washers spaced 6 in. o.c. -116.0
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 7 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX B
Approved Systems for GulfRib over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
RIB-W-9
Min. 1x4 No. 2
SYP wood
purlins spaced
24 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage
GulfRib Type 2 attachment with #9-15 x 1 1/2” HWH wood
screws with sealing washers spaced 24 in. o.c.
into wood purlins
-123.5
RIB-W-10 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 29 ga. GulfRib
36-inch coverage GulfRib Type 2 attachment with #9-15 HWH wood screws
with sealing washers spaced 12 in. o.c. -146.0
RIB-W-11 Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfRib
36-inch coverage GulfRib Type 2 attachment with #9-15 HWH WoodZAC
screws spaced 12 in. o.c. -159.25
RIB-W-12
Min. 1x4 No. 2
SYP wood
purlins spaced
12 in. o.c.
over
Min. 15/32
B-C plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC Min. 26 ga. GulfRib
36-inch coverage GulfRib Type 1 attachment with #9-15 HWH WoodZAC
screws spaced 12 in. o.c. into wood purlins -164.25
Approved Systems for GulfWave over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
WAVE-W1 Min. 15/32
B-C plywood
OPTIONAL
Approved fire
barrier or insulation As required per FBC Min. 26 ga. GulfWave
29-inch coverage
GulfWave Type 1 attachment with
#9-15 HWH wood screws with sealing washers
spaced 24 in. o.c. -78.5
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B, C, and D shall be as defined in section 1609 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd = 0.85
8. Vult is shown in the tables below. Design wind loads are calculated using Vasd = Vult√0.6 per 1609.3.1.
9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
.
a a a
3 3 a
2 2 1
2 3
a 3
2
a
3
2
2 3
3
1 2
2 3
a a
a
a
a
3
3 2
2
1
1
2 2 1
a
2 2 1
3
3
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure B (Roof slope between 2:12 and 12:12)
Building Type Zone
Mean
Roof
Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/
Partially Open
1
20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6
25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3
30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7
40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5
50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2
60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8
2
20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0
25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3
30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3
40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2
50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5
60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5
3
20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4
25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3
30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2
40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0
50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9
60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8
Partially
Enclosed
1
20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6
25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2
30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2
40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2
50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9
60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2
2
20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0
25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2
30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8
40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9
50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2
60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6
3
20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4
25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2
30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7
40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7
50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6
60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure C (Roof slope between 2:12 and 12:12)
Building Type Zone
Mean
Roof
Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/
Partially Open
1
20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5
25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0
30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6
40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4
50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1
60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7
2
20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5
25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1
30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8
40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7
50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0
60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7
3
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6
30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5
40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3
50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2
60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1
Partially
Enclosed
1
20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9
25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2
30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5
40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5
50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2
60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5
2
20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9
25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3
30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7
40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8
50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1
60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5
3
20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1
25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7
30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4
40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4
50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2
60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9
A CREEK
Technical Services, LLC
GCS20002a FL33818 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC
Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure D (Roof slope between 2:12 and 12:12)
Building Type Zone
Mean
Roof
Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/
Partially Open
1
20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0
25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5
30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1
40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9
50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6
60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1
2
20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4
25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0
30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6
40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6
50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9
60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6
3
20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2
25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1
30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0
40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8
50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7
60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6
Partially
Enclosed
1
20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8
25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2
30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5
40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5
50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1
60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5
2
20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2
25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6
30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1
40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2
50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5
60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9
3
20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1
25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7
30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4
40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4
50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2
60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9