HomeMy WebLinkAboutAPPROVED Extreme 1in SS_25621.1-R1_CV2020_method A1/19/2021 Florida Building Code Online
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYq0jrky58XYJ0cwJbweNYciw%3d%3d 1/4
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL25621-R1
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
David Eng
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL25621_R1_COI_26ga_SnapMax_plywood.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
1/19/2021 Florida Building Code Online
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYq0jrky58XYJ0cwJbweNYciw%3d%3d 2/4
Product Approval Method Method 1 Option D
Date Submitted 10/06/2020
Date Validated 10/16/2020
Date Pending FBC Approval 10/25/2020
Date Approved 12/16/2020
Date Revised 12/16/2020
Summary of Products
FL #Model, Number or Name Description
25621.1 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-97.25
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_26ga_SnapMax_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_26ga_SnapMax_plywood.pdf
Created by Independent Third Party: Yes
25621.2 02: 032 Aluminum SnapMax on
Plywood
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-78.5
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_032_SnapMax_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_032_SnapMax_plywood.pdf
Created by Independent Third Party: Yes
25621.3 03: 032 Aluminum 12" SnapMax on
Plywood
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
with 12" coverage on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-69.25
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_032_SnapMax_12in_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_032_SnapMax_12in_plywood.pdf
Created by Independent Third Party: Yes
25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-121.75
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_26ga_SnapMax_plywood_D.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_26ga_SnapMax_plywood_D.pdf
Created by Independent Third Party: Yes
25621.5 05: 26ga SnapMax on Plywood HVHZ 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-176
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_26ga_SnapMax_plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_26ga_SnapMax_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.6 06: 24ga SnapMax on Plywood 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_24ga_SnapMax_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_24ga_SnapMax_plywood.pdf
Created by Independent Third Party: Yes
25621.7 07: 032 Aluminum SnapMax on
Plywood
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Limits of Use Installation Instructions
1/19/2021 Florida Building Code Online
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYq0jrky58XYJ0cwJbweNYciw%3d%3d 3/4
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: Refer to evaluation report
FL25621_R1_II_032_SnapMax_plywood_d.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_032_SnapMax_plywood_d.pdf
Created by Independent Third Party: Yes
25621.8 08: 032 Aluminum SnapMax on
Plywood HVHZ
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-175
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_032_SnapMax_plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_032_SnapMax_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.9 09: 26ga 19" TopMax on Plywood 26ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32"
(min) plywood or 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_26ga_TopMax_19in_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_26ga_TopMax_19in_plywood.pdf
Created by Independent Third Party: Yes
25621.10 10: 032 Aluminum TopMax on
plywood HVHZ
Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-179.5
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_032_TopMax_plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_032_TopMax_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.11 11: 24ga TopMax on Plywood HVHZ 24ga (min) TopMax 1.5" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-153.5
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_24ga_TopMax_plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_24ga_TopMax_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.12 12: 24ga 19" TopMax on Plywood
HVHZ
24ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32"
(min) plywood or 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.25
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_24ga_TopMax_19in_plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_24ga_TopMax_19in_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.13 13: 032 Aluminum 19" TopMax on
plywood HVHZ
Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood
plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-166.75
Other: Refer to evaluation report
Installation Instructions
FL25621_R1_II_032_TopMax_19in_plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621_R1_AE_032_TopMax_19in_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails