Loading...
HomeMy WebLinkAboutAPPROVED roofing info sheet1. L.0 IE Section A (General Information) Master Permit No. Process No. Contractors Name: C lode- Q—aA- J2'0O7e(-!' License # C—C-C Job Address 404 0 ROOF CATEGORY �ow Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑Asphaltic Shingles �Vletal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ ❑ Maintenance C16.Reroofing ❑ Recovering ROOF SYSTEM INFORMATION �— Total (SF) Z Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ❑ New roof ❑Repair Low Slope Roof Area (SF) Z�w Steep Sloped Roof Area (SF) ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: 4774eftw' ii��'�bC1GG Product Approval No.: 25G-L( . t Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: ood'_ Gauge Thickness: Slope: 2 Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): n�efV10, Base Sheet Fastener/Bonding Material: J:Sc 1-F ad, NoacW Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: CX,+VeArA ► O-AC. SS Top Ply Fastener/Bonding Material: SLmw cL'X� Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—.._." oc @ Lap, # Rows 0 ' 0 Zone 1:—" oc @ Lap, # Rows 0 ' Zone 2:_" oc @ Lap, # Rows Q Zone 3:—" oc @ Lap, # Rows.— @ ' 0C Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . "Or LUCIE WORKS 01. Section D (Steep Slope Roof System) Roof System Manufacturer: , , r `eJeA` r s Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: Deck Type: i Type Underiayment Roof Siope: 12 Insulation: J Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: Adhesive Type: Type Cap Sheet I M FHeight:Roofean Roof Covering: Type & Size Drip Edge: fLcz, l\)atvl