HomeMy WebLinkAboutProdcut Approval - shingles 4=21 Florida Building Code Online
Business ► Professional Regulation
r
SCIS Home Log In ! User Registration ; Hot Topics Submit Surcharge Scats&Facts Publications Contact Us BCIS Site Map Links Search
Product Approval dUpr y; USER:Public User Fi!� Co!) .1
Product Apyroval Menu>Vroduct or Application Search>Application Lisl>Application DetaB !�j/ � //l
• FL# FL5444-R16 REVIEWED FOH
Application Type Revision CODE COMPLIANCE
Code Version 2020 Application Status Approved ST. LLjCIE COUNTY
Comments
BOCC 4�z 2l
Archived
Product Manufacturer CertainTeed, LLC(Roofing)
Address/Phone/Email 20 Moores Road
Malvern, PA 19355
(610)893-5400
mark.d.harner@saint-gobain.com
Authorized Signature Mark Harper
mark.d.hamer@saint-gobain.com
Technical Representative Mark D. Hamer
Address/Phone/Email 18 Moores Road
Malvern, PA 19355
(610)651-5847
Mark.D.Harner@saint-gobain.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/13/2022
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL5444 R16 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2019
Equivalence of Product Standards
Certified By
Sections from the Code
hllps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtah 1 g07CSsoycOrl28CcpCVLNbEH%2fDiLVOUC2YckaMTg%3d%3d 1/2
4/2/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 07/30/2020
Date Validated 08/04/2020
Date Pending FBC Approval 08/08/2020
Date Approved 10/13/2020
Summary of Products
FL# 1 Model, Number or Name Description
5444.1 i CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip(no-cut-outs), laminated and architectural
asphalt roof shingles
Limits of use Installation Instructions
Approved for use in HVHZ: No FL5444 R16 II 2020 07 24 FINAL ER CERTAINTEED FL5444-
Approved for use outside HVHZ:Yes R16.pdf
Impact Resistant: N/A ! Verified By: Robert Nieminen, PE PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use Evaluation Reports
FL5444 R16 AE 2020 07 24 FINAL ER CERTAINTEED FL5444
R16.pdf
Created by Independent Third Party:Yes
0
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer..Qmyright 2007-20t3 State of Florida.::Privasy.Statement::Accessibility,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here.
Product Approval Accepts:
®®® E N
Credit Card
Sate
https:/Moridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtah 1 gO7CSsoycOrl28CcpCVLN bE H%2fDiLVOUC2YckaMTg%3d%3d 2/2
NEW I etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
to (203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
CertainTeed, LLC Evaluation Report 3532.09.05-R17
20 Moores Road FL5444-1116
Malvern, PA 19355 Date of Issuance:09/22/2005
(610)893-5400 Revision 17:07/24/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7t'Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M.Nieminen,P.E.
Florida Registration No.59166,Florida DCA ANE1983 ��°•"�` �rr�r?' The facsimile seal appearing was authorized by Robert
�`:•
•�, Nieminen,P.E.on 07/24/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
9)2018 NEMO ETC,LLC
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
1. O.
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roof Shingles,as produced by CertainTeed,LLC, have demonstrated
compliance with the following sections of the 7'Edition(2020)Florida Building Code through testing in accordance
with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein.
2. STANDARDS:
Section Pro a Standard Year
1507.2.5,R905.2.4 Material standard ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind resistance ASTM D3161 2016
1507.2.7.1,R90S.2.6.1 Wind resistance ASTM D7158 2019
3. REFERENCES:
Entity Examination Reference Date
PRI(TST 5878) ASTM D3161 256TOO15 08/12/2019
UL(TST 1740) ASTM 03161 99NK26506 11/23/1999
UL(TST 1740) ASTM D3161 03CA12702 05/27/2003
UL(TST 1740) ASTM D3161 03CA12702 06/16/2003
UL(TST 1740) ASTM D3161 03NK29847 10/03/2003
UL(TST 1740) ASTM D3161 04CA11329 05/24/2004
UL(TST 1740) ASTM D3161 04CA32986 12/03/2004
UL(TST 1740) ASTM D3161 05NK07049 04/15/2005
UL(TST 1740) ASTM D3161 05NK16778 05/12/2005
UL(TST 1740) ASTM D3161 05CA16778 05/12/2005
UL(TST 1740) ASTM D3161 05NK14836 05/22/2005
UL(TST 1740) ASTM D3161 OSNK22800 06/22/2005
UL(TST 1740) ASTM D3462 R684 09/21/2005
UL(TST 1740) ASTM D7158 05NK08037 06/28/2006
UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009
UL(TST 1740) ASTM D3462 10CA41303 10/07/2010
UL(TST 1740) ASTM D3161 IOCA41303 10/08/2010
UL(TST 1740) ASTM D7158 10CA41303 10/27/2010
UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010
UL LLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013
UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014
UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014
UL LLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014
UL LLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015
UL LLC(TST 9628) ASTM D3161 4786821352 02/21/2015
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015
UL LLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787592174 10/21/2016
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016
UL LLC(TST 9628) ASTM D3462 4787380357 10/13/2016
UL LLC(TST 9628) ASTM D7158 4787380357 11/08/2016
UL LLC(TST 9628) ASTM D3161 4787380357 11/09/2016
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017
UL LLC(TST 9628) ASTM D3161&D3462 4788042412 11/15/2017
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4788362767 03/03/2018
UL LLC(QUA 9625) Quality Control Service Confirmation 11/13/2019
NEMO ETC,LLC Evaluation Report 3532.09.05-R17
Certificate of Authorization#32455 7m EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 2 of 14
ONEMO etc.
4. PRODUCT DESCRIPTION:
TABLE 1:ASPHALT SHINGLE COMPONENTS
Material
Type Product ' Description Standard Plant(s)
Fiberglass reinforced starter shingle,
High-Performance Starter measuring 10"x 36",for use with ASTM D3462 NC
t Grand Manor®and Highland Slate®
Fiberglass reinforced starter shingle,
measuring 13-1/4"x 40",with a
Presidential®Starter reinforcement on the underside,for ASTM D3462 CA(F)
use with Presidential Shake®and
Starter Presidential Shake"TL
Fiberglass reinforced starter shingle,
Strips Presidential®Starter IR measuring 13-1/4"x 40",for use with ASTM D3462 CA(F) I
I
Presidential Shake"IR E I
I
Fiberglass reinforced starter strip,SwiftStart"Starter Shingle ASTM D3462 MN
measuring 15-1/4"x 38-3/4"
Fiberglass reinforced starter shingle,
measuring 7"x 36",for use with
Universal Starter shingles measuring 12"x 36"having a ASTM D3462 NC
J weather exposure<5"
CT 20'" LA,NC
CT 20'"Metric i ) OR
XT'"25 Fiberglass reinforced,3-tab asphalt ASTM D3462 LA,MN,NC,OH
roof shingle
XT' 25 Metric OH,OR
XT'"30 IR I LA
Highland Slate" Fiberglass reinforced,4-tab asphalt ASTM D3462 NC
roof shingle
Arcadia'" ) CA(F)
Belmont® s NC
Belmont°IR NC
Carriage House® NC
Grand Manor* NC
Landmark® CA(W),GA,LA,MA,MO,
MN,NC,OH,OR,TX
Landmark®Pro Fiberglass reinforced,laminated CA(W),GA,MA,MO,MN,
Asphalt asphalt roof shingle ASTM D3462 OH,NC
Shingles . Landmark®Pro Architect 80 OR
Landmark Pro Solaris® I CA(W)
Landmark"Premium i CA(W),MA,MN,OR,NC
Landmark Solaris" II CA(W),OR
Landmark Solaris"Gold/Platinum OR
Landmark®TL CA(F)
landmark"TL Solaris CA(F)
Fiberglass reinforced,laminated,SBS
NorthGate® ASTM D3462 MN,OR
modified bitumen roof shingle
Presidential Shake" CA(F),MN
Presidential Shake"IR MN
Fiberglass reinforced,architectural ASTM D3462 CA(F),MN
Presidential Shake®TL asphalt roof shingle
Presidential Solaris" CA(F)
Presidential TL Solaris CA(F)
Fiberglass reinforced asphalt roof
Patriot ASTM D3462 OH,OR
strip-shingle; laminated appearance
Note: Any of the above listed shingles may be produced in AR(algae resistant)versions
NEW ETC,LLC Evaluation Report 3532.09.05-1117
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.5444-1116
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 3 of 14
ONEMO etc.
TABLE 1(CONTINUED):ASPHALT SHINGLE COMPONENTS
Material
Type Product Description Plant(s)
Standard
Shangle Ridge® ASTM D3462 e NC
Shadow Ridge® ASTM D3462 MA,MN,NC,OH
Hip& Shadow Ridge®Metric Fiberglass reinforced accessory ASTM D3462 OR
Ridge Cedar Crest® None NC
Shingles Cedar Crest®IR shingles for hip and ridge installation None NC
NorthGate®Ridge ASTM D3462 OR
NorthGate®Accessory ASTM D3462 MN
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications.
TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES
Product I FBC Table 1507.2.7.1 or R905.2.6.1
CT 20'" ASTM D3161(F)&ASTM D7158(H)
CT 20"Metric ASTM D3161(F)&ASTM D7158(H)
XT'"25 ASTM D3161(F)&ASTM D7158(H)
XT'"25 Metric ASTM D3161(F)&ASTM D7158(H)
XT'"30 IR ASTM D3161(F)&ASTM D7158(H)
Arcadia" ASTM D3161(F)&ASTM D7158(H)
Belmont® i ASTM D3161(F)&ASTM D7158(H)
Belmont*IR ASTM D3161(F)&ASTM D7158(H)
Carriage House® ASTM D3161(F)&ASTM D7158(H)
Grand Manor' i ASTM D3161(F)&ASTM D7158(H)
landmark® ASTM D3161(F)&ASTM D7158(H)
Landmark®Pro ASTM D3161(F)&ASTM D7158(H)
Landmark®Pro Architect 80 ASTM D3161(F)&ASTM D7158(H)
Landmark Pro Solaris® ASTM D3161(F)&ASTM D7158(H)
Landmark®Premium ASTM D3161(F)&ASTM D7158(H)
Landmark Solaris® ASTM D3161(F)&ASTM D7158(H)
Landmark Solaris®Gold/Platinum ASTM D3161(F)&ASTM D7158(H)
Landmark®TL ASTM D3161(F)&ASTM D7158(H)
NorthGateO ASTM D3161(F)&ASTM D7158(H)
Presidential Shake® ASTM D3161(F)&ASTM D7158(H)
Presidential Shake®IR ASTM D3161(F)&ASTM D7158(H)
NEMO ETC,LLC Evaluation Report 3532.09.05-R37
Certificate ofAuthorizotion#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-1116
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 4 of 14
ONEMO etc.
TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES
Product FBC Table 1507.2.7.1 or R905.2.6.1
Presidential Shake®TL ASTM D3161(F)&ASTM D7158(H)
Presidential SolarisO ASTM D3161(F)&ASTM D7158(H)
j Presidential TL Solaris ASTM D3161(F)&ASTM D7158(H)
Highland Slate® ASTM D3161(F)&ASTM D7158(H)
Patriot ASTM D3161(F)&ASTM D7158(H)
5.5.1 Classification by ASTM D7158:
ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT or RA)for the CertainTeed
asphalt Roof shingles listed in Table 1 (except Presidential Solaris® Landmark Pro Solaris®and Landmark Solaris®
Gold/Platinum)exceeds the calculated uplift force(FT)under the following conditions:
• maximum design wind speed of Va,d=150 mph(V,,it=194 mph)
• located in Exposure D conditions
• no topographical variations(flat terrain)
• having a mean roof height less than or equal to 60 feet.
The shingles (except Presidential Solaris®, Landmark Pro Solaris® and Landmark Solaris® Gold/Platinum) are
permissible under Code for installation in these conditions using the installation procedures detailed in this
Evaluation Report and CertainTeed minimum requirements,subject to minimum codified fastening requirements
established within any local jurisdiction,which shall take precedence.
TABLE 2B:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE
Type Product FBC Table 1507.2.7.1 or R905.2.6.1
High-Performance Starter ASTM D3161,Class F
Presidential®Starter ASTM D3161,Class F
Starter Strips i Presidential®Starter IR ASTM D3161,Class F
SwiftStart"Starter Shingle ASTM D3161,Class F
Universal Starter c ASTM D3161,Class F
Shangle Ridge® ! ASTM D3161,Class F(sealant required,See Section 6)
Shadow Ridge®(NC production) ASTM D3161,Class F
Shadow Ridge®(MA,MN or OH production) ASTM D3161,Class F(sealant required,See Section 6)
I Hip&Ridge Shadow Ridge®Metric(OR production) ASTM D3161,Class F(sealant required,See Section 6)
Shingles Cedar Crest® ASTM D3161,Class F(sealant required,See Section 6)
Cedar Crest•IR ASTM D3161,Class F(sealant required,See Section 6)
NorthGate®Ridge ASTM D3161,Class F
NorthGate•Accessory ASTM D3161,Class F
5.5.2 High-Performance Starter shingles are limited to use with Grand Manor®and Highland Slate®shingles.
5.5.3 Presidential® Starter shingles must be applied using two (2) overlapping layers and are limited to use with
Presidential Shake®and Presidential Shake®TL shingles.
5.5.4 Presidential® Starter IR shingles must be applied using two (2) overlapping layers and are limited to use with
Presidential Shake®IR shingles.
5.5.5 Universal Starter shingles are limited to use with CertainTeed shingles measuring 12" x 36" having a weather
exposure<5".
NEW ETC,LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization#32455 7m EDITION(2020)FBC NON-HVHZ EVALUATION F1.5444-1116
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 5 of 14
ONEIVIOletc.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
INSTALLATION:6.
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed,LLC and shall hold current Florida Statewide Product Approval,
or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Installation of asphalt shingles shall comply with the CertainTeed, LLC current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum
requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal,use the"Steep Slope"directions.
6.3 CertainTeed asphalt shingles are acceptable for use in reroof (tear-off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.4 HIGH-PERFORMANCE STARTER:
6.4.1 Eaves: For the first starter shingle in each roof corner,use five(5)nails as shown below. All other starter
shingles require four(4)nails per shingle. Nails must be of sufficient length to penetrate into the deck 3/4"or
through the thickness of the decking,whichever is less. Nails are to be it or 12 gauge,corrosion-resistant
roofing nails with 3/8" heads. Apply the 10"starter shingle with its factory-applied sealant stripes at the
shingle's lower-most edge and nail firmly into the roof deck as near as possible*(maximum 3")to the eaves
edge while avoiding the sealant.With the starter shingle well fastened to the deck and the sealant low on the
starter shingle,it can firmly adhere to the first course shingles. *If nailing within 3"is not possible, nail as
closely as possible,then lift and adhere the starter shingle to the underlayment and to the supporting structure
with CertainTeed FlintBond'"Asphalt Roofing Cement-Caulk Grade,or approved equal.
Rakes: Prior to installation of the field shingles,starter shingles may be applied up the slope along the rake edge
with sealant edge placed closest to the rake edge. Fasten as indicated below.
HIGH-PERFORMANCE STARTER SHINGLES
36'
i
i
t 3/8'(M ax 3')
NEMO ETC,LLC Evaluation Report 3532.09.05-1117
Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-1116
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 6 of 14
OMEMO I etc.
6.5 PRESIDENTIALO STARTER AND PRESIDENTIAL STARTER IR:
6.5.1 General: These shingles shall be applied by using two(2)overlapping layers. Begin application of the
bottom/lower layer of starter shingles by cutting and applying a 13-3/4"x 20" piece at the lower left rake/eaves
corner overhanging rakes and eaves 1/4"to 3/4". Continue along the eaves with full-size 13-1/4"x 40"starter
shingles. Each top/upper starter course shingle shall have its 2"top section removed at the perforations,
resulting in 11-1/4"x 40"shingles.The colored granule portion of the"top"starter shingles shall be located
nearest the lowermost eave edge. Install the first top/upper starter shingle so that it is flush to the left side and
bottom edges of the first bottom/lower starter shingle. This first top/upper starter shingle shall be 11-1/4"x
38". Continue along the eaves with 11-1/4"x 40"top/upper starter shingles ensuring that the lower edges are
flush with the lower edges of the bottom/lower layer. Reference the product's wrapper for more specific
details.
Eaves: Fasten as shown below. Rakes:After applying the starter shingles at the eaves,but prior to installing
the field shingles,starter shingles may be applied up the slope at the rake edge. Fasten as shown below.
Fastening: Four nails are required per shingle. Nails shall be of sufficient length to penetrate into the deck 3/4"
or through the thickness of the decking,whichever is less. Nails are to be 11 or 12 gauge,corrosion-resistant
roofing nails with 3/8" heads.
Presidential Starter and Presidential IR Starter Shingles
1st aria Full Bottom 8terbr
i31�" lot s9ts�r
ii�
6.6 UNIVERSAL STARTER:
6.6.1 General: While Universal Starter Strip shingles are specifically designed to be used with shingles 36"length and
having a weather exposure of<5",they may be installed beneath shingles of any length if special precautions
are taken. IMPORTANT: In all cases the end joints of the starter and the first course shingles shall NEVER BE
LESS THAN 3-1/2"apart.
Eaves: The sealant on starter courses should face out and lie as close as possible to the eaves edge of the roof.
Fasten as described below. Rakes: After applying the starter shingles at the eaves, but prior to installing the
field shingles, starter shingles may be applied up the slope at the rake edge with sealant facing out and nearest
to the outer roof edge. Fasten as described below.
Fastening: Use four nails on these starter shingles as shown below. The sealant on starter courses shall lie as
close as possible to the eaves edge of the roof. Nails shall be of sufficient length to penetrate into the deck 3/4"
or through the thickness of the decking,whichever is less. Nails are to be 11 or 12 gauge,corrosion-resistant
roofing nails with 3/8" heads.
UNIVERSAL STARTER SHINGLES
36,
12'—
. ' 7.
Max 3'
NEMO ETC,LLC Evaluation Report 3532.09.05-1117
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 7 of 14
ONEMO etc.
6.7 SWIFTSTART®STARTER SHINGLE:
Fastening: Use four nails, located as shown below
38-3/4'(984 mm) - ! 4
•-V(25 mm)from edge 1'(25 mm)from edge ( 7-5/8'
• • . • 194 mm)
Max3' m� � � � � � �
(76 mm) � aW _
fThe inner two fasteners must be placed such that they fall at least 3'(76 mm)from
the end joints of the shingle in the succeeding course.
6.8 CT 20T",XTT"25,XTT"30 IR:
LOW AND STANDARD SLOPE STEEP SLOPE
ENGLISH 12'' 12" 12" Use four nails and six spots of asphalt roofing cement"for every full
(305 mm) (305 mm)--- (305 mm) shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586
�l"(25 mm) —Sealant
lant 1"(25 mm)�{ Type II is suggested.
Plant
551e"(145 mm) 1
rl2,,for orwooe
METRIC
Roofing Cement
1"(25 mm) Sealant 1"(25 mm) Apply 1"(25 mm)spots of asphalt roofing cement
——— _ —— —— under each tab corner.
6 Figure 11-4:•Use four nails and six spots ofaspbatt comert on Amp slope&
CAUTION:Excessive use of roofing cement can cause shingles
to blister.
Figure 113-Usefoarnailsforetwryfull sbingle.
Hip&Ridge: Cut Shingles
Note:The use of BASF"Sonolastic®NPl T""adhesive or Henkel"PLO Polyurethane Roof& Flashing Sealant"in accordance
with CertainTeed requirements is required for the ASTM D3161, Class F wind rating.
1";I a F-2"(50 mm} Remove 5„ 12"(305 mm)'� F�
(25 mm)� t� ��- ^►i (125 mm) `�
F
t :\12 ap Cap Cap 305 mm) \ 145 ngle Shingle Shingle t`�1(2�ovclo�t1
Figure 11-24.Cut tabs,then Iron back to make cap sbin#es Figure 11-25.Installation of caps along the bips and ridges.
(English dimensions shown).
NEMO ETC,LLC Evaluation Report 3532.09.OS-R37
Certificate of Authorization#31455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 8 of 14
ONEMOjetc.
6.9 ARCADIAm:
LOW AND STANDARD SLOPE STEEP SLOPE
(se SIX nails for c%m full shingle located as shown below, Use SIX nails and FOUR spots of asphalt roofing cement for ever}full
shingle ac shown below.Apply asphalt roofing cement 1"(25 mm)
from edge of shingle.Asphalt roofing cement meeting.tSTM D 4586
71pe fl is suggested.
f t'(25 mm) 1'(25 min)
Nad Line
Nail
Nail Line r(25 min) t'(25 mm)
Figure 2:Ise six neilc frrr evej7r fall shingle. C, :1c)
Figure 3:1se six nails and four spots of asphalt
rm,fing cement on steep slopes.
Hip&Ridge: Cedar Crest"or Cedar Crest®IR
Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side
edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum %-inch embedment into the
deck,or full penetration through the deck. For each full Cedar Crest shingle,place fasteners 8-5/8-inch up from its exposed
butt edge and 1-inch from each side edge.
Note: The use of BASF"Sonolostic"NP1"adhesive or Henkel"PL"Polyurethane Roof& Flashing Sealant"in accordance
with CertainTeed requirements is required for the ASTM D3161, Class F wind rating.
Hand-sealing adhesive
Z03 min) (�min)r_•I 1/4" 4"
\R �
1"
Dab of asphalt
cement between
shingle layers
NEMO ETC,LLC Evaluation Report 3532.09.05-1117
Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 9 of 14
NEW etc.
6.10 BELMONTO OR BELMONT*IR:
Low and Standard Slope Steep Slope (greater than 21:12):
(2:12 to 21:12): Use SEVEN nails and EIGHT spots of
Use FIVE nails for every full Belmont shingle, asphalt roofing cement"for every full
located as shown below. Belmont shingle_Apply asphalt roofing
+ cement 1"(25mm)from edge of shingle_
"a(�m' t See below_Asphalt roofing cement meeting
1,ZMW -1 ASTM D4586 Type II is suggested.
}
-W.(16 rrrn) 8 516' 1 1 t2 (38 rren)
�inin) Of lei
o Additro4 nails it required
} I
AW(16 rnn) 8518
I ' (220 rvr
1'(A mm) `` Rroling CemeN --
Hip&Ridge'
Option 1: For Belmont®, refer to instructions for Cedar Crest®or Cedar Crest®IR.
For Belmont® IR, refer to instructions for Cedar Crest® IR.
Note: The use of BASF"Sonolastic®NP1"adhesive or Henkel"PLO Polyurethane Roof&Flashing Sealant"
in accordance with Certain Teed requirements is required for the ASTM D3161, Class F wind rating.
Option 2: For Belmont®: ShangleO Ridge
Note: The use of BASF'Sonolastic®NP1"adhesive or Henkel"PLO Polyurethane Roof&Flashing Sealant"
in accordance with Certain Teed requirements is required for the ASTM 03161, Class F wind rating.
12' 181, Exposure Remove tape
from the right side
1", g•� and fasten
j If SECOND
Fasten theme'
Remove left side 851a RIGHT
This Tape FIRST
LEFT
Figure 17-19:Installation of Shangleo Ridge shingles
Figure 17-18:Shangle"Ridge, on hips and ridges.
NEMO ETC,LLC Evaluation Report 3532.09.05-R37
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 10 of 14
ONEMO I etc.
6.11 CARRIAGE HOUSE®AND GRAND MANOR®:
LOW AND STEEP SLOPE
STANDARD SLOPE Use seven nails and three spots of asphalt roofing cement for every
Use five nails for every full ShaiWe. full Grand Manor Shangle.Use five nails and three spots of asphalt
roofing cement for every full Carriage house Shangle and Centennial
Slate.Apply asphalt roofing cement 1" (25 mm)from edge of shingle
(Figure 17-5).Asphalt roofing cement mc<+ling ASTM 1A586 7tpe[I
1" 1" is suggested.
1f(25 mm) (25 mm)
1 112"
(38 m)
(16 mm) (220 mm) 1. or leas 1"12L �(25 mm) (25 mm)
po
Figure 17-4:Lase fine nails for every full Grand Manor Sbangle,
Carriage House.Sbangle.or Centennial Stale. 0 � I� �` (220 m)
1" T ----
(25 mm) Roofinn Cement
Figure 17-5:When installing Grand Manor Sbangles on steep slopes,
use seeeir nails and three spots of aspbatt roofing cement.
Hip&Ridge: Refer to instructions for Shangle®Ridge.
6.12 LANDMARK®,LANDMARK®PRO,LANDMARK®PRO ARCHITECT 80,LANDMARK PRO SOLARISO,LANDMARK°PREMIUM,LANDMARK
SOLARISw,LANDMARK SOLARIS®IR,LANDMARK SOLARIS®GOLD/PLATINUM OR NORTHGATE®:
.11DE
NA[LhG 12' 14 34' 1Z'
`# 005+"w l t X5 mm) f (305 nm? i1
haiirg-T is
yl r(25 mmy Uript ".at lne r(25 een)—o r—
owe,nai Me
{
Natilnp man for low and standard abpaa(from 2:12 to 21 121
Nat oeM"n upper 8 bwer Inca as svwn above.
STEEP 12" 1"4" 12'
SLOPE !+-{305 mm)-- 375 mmj-� -*-(305 mm}-►j
MAILING AREA 1 1•(25 mn) Nail nnqq mit beiwae) jmite r 1'(25 mm)-
nal Imes,
Roofing Cement
Nailing areas for steep slopes(greater fm 21:12)
and"Storm-Nailing"
Nail between lower 2 rag lines as shown above.
NEW ETC,LLC Evaluation Report 3532.09.05-R37
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertatnTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 11 of 14
OMEMO I etc.
Hip&Riche:
Option 1: Refer to instructions for Cedar Crest®or Cedar Crest® IR.
Option 2: NorthGate®Accessory or Shadow Ridge®
Note: The use of BASF'Sonolostic®NP1'""adhesive or Henkel "PLO Polyurethane Roof&Flashing
Sealant"in accordance with Certain Teed requirements is required for the ASTM D3161, Class F wind
rating. (Use of sealant is optional for Shadow Ridge®produced in Oxford. NC.)
9 271?2'
( (250 mm;
415118(125mmj
�— 13 1/8"
t � (333 mm)- s
{ Centerfrg Notch 6 5/8'►If-6 5/8"
II] 168 mm 168 mm
131/1'
(337 mm
or then i Centering
notches to Hop 7 $ 13 114" R Notch � ,
edge of (337 mm) \Align these
1 prevous course f194 trim) 7 4 m
notches to top (194 mm)
edge of
j previous course.
NorthGate®Ridge NorthGate®Accessory
12" L 9718" „
�—(305mm) — (250mm)
�—6--I�6 —415/1ti' 415/i6"—
(150mm) ; (150mm) (125mm) (125mm)
Notch for Notch for
Centering Centering
12' r
131/4"
f
(305mm) Notches for Alignment to 7' (337mm) Notches for Alignment to 5
the Top Edge of the Previous (18(k 7
m) I the Top Edge of the Previous (196mm)
Cap for 5"(125mm)Exposure Cap for 55/8"(141 mm)Exposure
English Dimension Metric Dimension
Shadow Ridge® Shadow Ridge®
-2-
r(3o5mm)—
Laying Notch
I
I' l
Exposure
I I
Figure 13-20 Use laying notches to center shingles on btps and
ridges,and to locate the correct ezposum
NEMO ETC,LLC Evaluation Report 3532.09.05-R37
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.5444-1116
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 12 of 14
ONEMO etc.
6.13 LANDMARK®TL:
LANDMARK TL
LANDMARK TL 13112" 13"—r}.--13i/2'�{
(343 mm) lii (330 mm) (343 mm)
131/2" 13" 131/2"
—(343 mm)i (330 mm)—4—(343 mm)--j 1"(25 mm) 1"(25 mm)--1
1 n I
I�-1"(25 mm) 1"(25 mm)—►I
rd
(25 mm) ---- ;5(25 rnm)
Roofing Cement
Figure 1,3-4:L'se four nails for every frill shingle. Figure 13 S:Use six nails card four spots of
asphalt roofing cement on steep slopes
Hip&Ridge: Refer to instructions for Cedar Crest®,Cedar Crest® IR, NorthGate®Accessory or Shadow Ridge®.
6.14 PRESIDENTIAL SHAKE®,PRESIDENTIAL SHAKE®IR,PRESIDENTIAL SHAKE®TL,PRESIDENTIAL SOLARIS®:
LOW AND STANDARD SLOPE: STEEP SLOPE:
For low and standard slopes,use five nails for each full Presidential For steep slopes,use nine nails for each full Presidential shingle and
shingle as shown below. apply I'diameter spots of asphalt roofing cement under each shingle tab.
After applying 5 nails in between the nailing guide lines,apply 4 nails 1'
Nailing 40" +i above tab cutouts maldng certain tabs of overlying shingle cover nails
Guide Lines (1016 mm)
51l4' �—
(13314 14 114"
L 1 112' 38 mm) (362 mm) • • •
I
NOTE:Apply nails on painted guideline.
Figure 164 FasteninghiendenNal and Presidential TL Shake I'diameter asphalt roofing cement
shingles on lore and standard slopes.
Figure 16-7.Fasientng Presidential and Presidential T/L Shake
sbingles on steep slopes.
Hip&Ridge: Refer to instructions for Cedar Crest®or Cedar Crest®IR.
NEMO ETC,LLC Evaluation Report 3532.09.05-R17
Certificate afAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 13 of 14
r -
ONEMOjetc.
6.1S HIGHLAND SLATE:
LOW AND STANDARD SLOPE: STEEP SLOPE:
Use FIVE nails and BIGHT spots of asphalt roofing cement"for each
230 m'N ,,mot m ) Raos„�„� 1,1230M)`� full Highland Slate shingle.For Mfaud-Dade,SIX nails are required.
Apply V diameter spots of asphalt roofing cement under each tab
t„ corner.Asphalt roofing cement meeting ASTM D4586 Type II is suggested.
iR5mm)
17aD�Y QBo mm) 1�nn) laso^m
gals,
(24�mm)
_jL �smml R5 mml
Miami-Dade requires
e 3s
SlXnas(lwonails V(25mm) Miami-Dedsmqukm f QSmm (240—)
instal led over center SR wads(Mb nails )
cutout as shown). nstalled Dyer cenbr =
rutaA es shorn} —— Roo1Mg Cement
Figure 11-3:Use FIVE nails for every lfigblarul Slate shingle. Figure II.3A:Use HVB rails and eigbt spots ofaspbalt
roofing cement wilder oacb tab corner:
'CAUTION:Excessive use of roofing cement can cause shingles
to blister.
Hip&Hip&Ridge: Refer to instructions for Cedar Crest®,Cedar Crest® IR or Shangle Ridge®.
6.16 PATRIOT:
LOW AND STANDARD SLOPE STEEP SLOPE
I se 1`01 R nails for every-full shingle located as shown below. Use FO172 nails and four spots of asphalt roofing cernent for even'hill
shingle as shown below.Asphalt roofmg cement meeting,VqM D4596
11pe 11 is suggested.Apply 1'(25 mni)spots of asphalt roofing
Sealan± content as shown.
r CAUTION:Excessive use of roofing cement can cause shingles to bW-er.
CrllSy mini ---j E!72t -'
(156mm) I Ir
- _ _------ ——
(333 mini 3s — � 'T 1 5 t,0't t25 acN t(25 eet—t
756mm) t�
I Roofing Cemeetl
Hip&Hip&Ridge: Refer to instructions for Cedar Crest®,Cedar Crest®IR,NorthGate®Accessory,Shadow Ridge®or Shangle
Ridge"'.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 614320-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409; karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 3532.09.05-R37
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020
Page 14 of 14