HomeMy WebLinkAboutProduct Approval - underlayment Florida Building Code Online Page 1 of 3
Business ' 0
Professional Regulation
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publ�ti L/Co s IS Site Mao Links Search
Product Approval
ra oUSER:Public User lj(v
, ,H<v REVIEWED FOR
Product Aobroval Meru>Product cr Application Search>Application Lisl>Application Dltaq
FL# FL25974-R1 CODE COMPLIANCE
Application Type Editorial Change ST■ L IE COU T F
Code Version Denied
OCC ��
Application Status Denied
Comments
Archived
Product Manufacturer APOC,Sub of Gardner-Gibson Inc.
Address/Phone/Email 4161 E. 7th Avenue
Tampa,FL 33605
(813)248-2101
akhan@gardner-gibson.com
Authorized Signature Amir Khan
akhan@gardner-gibson.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Test Report
Testing Lab PRI Construction Materials Technologies, LLC
Quality Assurance Entity Miami-Dade BCCO-QUA
Quality Assurance Contract Expiration Date 03/28/2023
Validated By Locke Bowden P.E.
d Validation Checklist- Hardcopy Received
Certificate of Independence FL25974 R1 COI Certificate of Independence.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4533 2015
TAS 103 1995
Equivalence of Product Standards
Certified By Approved Testing Lab
FL25974 R3 Epuiv Equivalency Letter.odf
Product Approval Method Method 1 Option B
Date Submitted 12/20/2019
file:///C:/1Jsers/ISENHO-1/AppData/Local/Temp/Low/ORYJI415.htm 4/28/2021
Florida Building Code Online Page 2 of 3
Date Validated 12/27/2019
Date Pending FBC Approval 01/13/2020
Date Denied 04/07/2020
Summary of Products
FL# Model,Number or Name Description
25974.1 CX-L High strength hybrid underlayment comprised of two layers of
polyolefin and polyester synthetic fabric with a thin layer of
modified bitumen between the two plies.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25974 R1 II CX-L Crossover GGI-176-02-01 Report Rev
Approved for use outside HVHZ:Yes 2-ASTM D 226 and D 1970 partial for synthetic
Impact Resistant:N/A underlavment.odf
Design Pressure:N/A Verified By: PRI Construction Materials Technologies,LLC
Other: Test Reports
FL25974 R1 TR CX-L Crossover GGI-176-02-01 Report Rev
2=A�M D 226 dnd D_1.97.Q_p�rtial__f�r_synthe..tic
underlavment.odf
25974.2 FT3 Self-adhering membrane composed of elastic polymers,
bitumen polyester and glass reinforcement.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25974 R.1 I) FT3 GGI-195-02-02 Report-ASTM D 1970-
Approved for use outside HVHZ:Yes 09.:pdf
Impact Resistant: N/A FL25974 R1 II FT3 GGI-196-02-01 Report-TAS 103.Ddf
Design Pressure:N/A Verified By: PRI Construction Materials Technologies,LLC
Other: Test Reports
F_L259,74__Ri,,,_TR.,._F"_3 GGI-195.-02.-02_Repart„_=ASTM D._197.0_-.
09.odf
FL25974 R1 TR FT3 GGI-196-02-01 Report-TAS 103.pdf
25974.3 GatorSkin Synthetic roof underlayment comprised of layers of polyolefin
film.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25974 R1 II Gator5kin GGI-132-02-06 Report-ASTM D
Approved for use outside HVHZ:Yes 226 FBC 1.507-1-1 for Gator Skin.odf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies,LLC
Design Pressure:N/A Test Reports
Other: FL25974 R1 TR GatorSkin GGI-132-02-06 Report-ASTM D
226 FBC 1507-1-1 for Gator Skin.Ddf
25974.4 HT3 Self-adhering membrane composed of elastic polymers,
bitumen,glass reinforcements and a cross laminated sheet
surfacing.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25974 R1 tI HT 3 GGI-194-02-01.3 HT3 ASTM D
Approved for use outside HVHZ:Yes 19 7(, jp
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies,LLC
Design Pressure:N/A Test Reports
Other: FL25974 R1 TR HT 3 GGI-194-02-01.3 HT3 ASTM D
i9%O,,pdf
25974.5 SB-1 Glass fiber reinforced,polymer modified asphalt,granulated
self-adhered underlayment.
Limits se Installation Instructions
p roved for use in HVHZ:Yes FL25974 R1 tI SB-1 GGl 178 02 O1 ASTM D1970 90
Approved for use outside HVHZ:Yes day.odf
Impact Resistant:N/A Verified By: PRI Construction Materials Technologies,LLC
Design Pressure:N/A Test Reports
Other: FL25974 R1 TR SB-1 GGI-173-02-01 ASTM D1970 90
day,x1f
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
W1
file:///C:/Users/ISENHO—I/AppData/Local/Temp/Low/ORYJ1415.htm 4/28/2021
CONSTRUCTION MATERIALS
TECHNOLOGIES
LABORATORY TEST RESULTS
Report for: Gardner Gibson Attention: Matt Mullins
4146 E. 711,Avenue
Tampa, FL 33605
Product Name(s): Weather-Armor SB-1 Self-Bond Manufacturer: Gardner Gibson
Roof Underlayment
PRI-CMT Project No.: GGI-178-02-01 Source: See Sampling Section
GGI-178-02-02
Date Received: See Sampling Section Dates Tested: Sept. 29, 2016—Oct. 21, 2016
Oct.25, 2017—Nov. 28, 2017
Purpose: Determine specification properties for Gardner Gibson's Weather-Armor SB-1
Self-Bond Underlayment for compliance with ASTM D 1970: Standard
Specification for Self-Adhering Polymer Modified Bituminous Sheet
Materials Used as Steep Roofing Underlayment for ice Dam Protection.
Gardner Gibson's Weather-Armor S8-1 Self-Bond Underlayment is a granule
surfaced, self-adhering, waterproofing underlayment.
Testing for Extended Exposure for 90d was conducted in accordance with
Miami-Dade County RER Product Control.
Test Methods: Testing was completed as described in ASTM D 1970-15: Standard
Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials
Used as Steep Roofing Underlayment for Ice Dam Protection. Test methods
assigned or referenced include ASTM D 903: Standard Test Method for Pee/or
Stripping Strength of Adhesive Bonds,ASTM D 1204:Standard Test Method for
Linear Dimensional Changes of Nonrigid Thermoplastic Sheeting or Film at
Elevated Temperature,ASTM D 2523: Standard Practice for Testing Load-Strain
Properties of Roofing Membranes, ASTM D 4073: Standard Test Method for
Tensile-Tear Strength of Bituminous Roofing Membranes, ASTM D 5147:
Standard Test Methods for Sampling and Testing Modified Bituminous Sheet
Material, and ASTM E 96: Standard Test Methods for Water Vapor Transmission
of Materials.
Sampling Information: Samples were received from Tampa, FL.
Product Source Date
Weather-Armor SB-1 Tampa,FL September 14,2016
Weather-Armor S13-1 Tampa,FL September 17,2017
GGI-178-02-02 PRI-CMT Accreditations:IAS TL-189 Miami-Dade 11-0429.05:Florida TST5878 Los Angeles TA24819:CRRC
The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated
client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report.
PRI Constrocion Materials Technologies LLC 6408 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813.621-5840 a-rr.ail:materaistesfing@phcmt.com WebSite.http:Nwew,pncmt.com
Gardner Gibson
ASTM D 1970 for
Weather-Armor SB-1 Self-Bond Underlayment
Page 2 of 6
Results of Testing:
ASTM D 1970
Property .. Requirement—
Physical Requirements
Thickness; min; (mils)
1 specimen; 27-1/2"x manufacture width; ASTM D 5147 72 >_40
5 measurement points
Maximum Load (Ibf/in-width)
5 specimens; 1"x 6'; ASTM D 2523/
Cond. 2h @ 73.4t3.6°F; ASTM D 1970
Test @ 73.4t3.6°F; Rate=2in/min t3%
MD 61 a 25
CMD 42 z 25
Elongation at Break (modified bitumen portion) (%)
5 specimens; 1"x 6"; ASTM D 2523!
Cond. 2h @ 73.4t3.6'F; ASTM D 1970
Test @ 73.4t3.6°F; Rate=2in/min t3%
MD 15 >_ 10
CMD 20 10
Adhesion to plywood (Ibf/ft-width)
5 specimens; 3" x 8" (bonded 3" x 5"to plywood) ASTM D 903/ 6.2 z 2.0
Cond. 1 h @ 40t20F; ASTM D 1970
Test @ 40t2°F; Rate=2in/min t3%
Adhesion to plywood(Ibf/ft-width)
5 specimens; 3" x 8" (bonded 3" x 5"to plywood) ASTM D 903/ 15 >_ 12
Cond. 1h @ 75t2°F; ASTM D 1970
Test @ 75t2°F; Rate= 2in/min t3%
Continued on following page
GGI-178-02-02 PRI-CMT Accreditations IAS TL-189 Miami-Dade 11-0429.05 Florida TST5878:Los Angeles TA24819:CRRC
The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated
client. No reproduction or facsimile in any form can be made without the clients permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report.
PRI Cnstmction Materials Technologies LLC 6408 Badger Drive Tampa.FL 33610 Tel:813-621 177 Fax.813-621-5840 e-mail:matedalstesting@pricmt.com Web&W http:i,Www.pricmt.com
Gardner Gibson
ASTM D 1970 for
Weather-Armor SB-1 Self-Bond Underlayment
Page 3 of 6
MethodProperty Test Requirement
Thermal Stability-Type 2 (in)
5 specimens; 4" x 4" (bonded to plywood); ASTM D 1204/ -0 < 0.1
Test 14d @ 203t3.6'F; ASTM D 1970
Equilibrate to 75t20F &50t5%RH for 4h;
Low Temperature Flexibility(PasslFail]
5 specimens; 1" x 6"
Cond. 2h @-20'F; ASTM D 1970
Test 180±5'over V±5% o in 2t1s @-20'F;
Visual Inspection in"flexed" position:
Self Sealability(head of water test)on"flexed" specimen
No visible signs of
cracking in the
MD Pass sheet -or- minor
surface cracking
and"pass"head of
water test
No visible signs of
cracking in the
CMD Pass sheet -or- minor
surface cracking
and"pass"head of
water test
Tear Resistance; min; (lbf)
5 specimens: 3" x 8"with assigned notch; ASTM D 4073/
Cond. 4h @ 74t4'F & 50f5%RH; ASTM D 1970
Test @ 74t4'F; Rate=2.Oinlmin t3%
MD 86 >_20
CMD 64 >_20
Moisture Vapor Permeance (U.S. Perms)
3 specimens; 3.5" o; ASTM E 96 0.02 s 0.1
Weathering side to higher vapor pressure; Procedure BW
Test @ 73.4t3.6'F & 50t5%RH
Self-Sealability[Pass/Fail]
2 specimens; 12" x 12" (bonded to plywood); ASTM D 1970/
ASTM D 3462 single thickness intervening material; ASTM D 7349
Two 1-1/4" roofing nails placed near center of specimen; Pass Pass
Cond. 24h @ ambient; Protocol 4
Test 5inw.c. @ 40t50F for 3d; (modified)
Visual Inspection for water infiltration
Bottom Can; [WaterlNo Water] No Water No Water
Nail Shank; [WaterlNo Water] No Water No Water
Underside of Plywood; [Water/No Water] No Water No Water
Between Plywood & Underlayment; [WaterlNo Water] No Water No Water
Continued on following page
GGI-178-02-02 PRI-CMT Accreditations IAS TL-189 Miami-Dade 11-0429 05 Florida TST5878 Los Angeles TA24819:CRRC
The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated
client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report.
PRI Construction Materials Technologies LLC 6408 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:81 M21-5840 e-mail materialstestingCpricmt.com WebSite:http:1w m.pncmtcom
Gardner Gibson
ASTM D 1970 for
Weather-Armor SB-1 Self-Bond Undedayment
Page 4 of 6
Property •• ••
Self-Sealability; After Low Temp Flexibility[Pass/Fail]
2 specimens,
Low Temperature Flexibility specimen; ASTM D 1970 Pass Pass
Cond. 24h @ ambient;
Test 5inw.c. @ 40t5°F for 3d;
Visual Inspection for water infiltration
Bottom Can;[Water/No Water] No Water No Water
Nail Shank; [Water/No Water] No Water No Water
Underside of Plywood; [Water/No Water] No Water No Water
Between Plywood &Undedayment; [Water/No Water] No Water No Water
Self-Sealability; Lap Seam [Pass/Fail]
2 specimens- 12"x 12" (bonded to plywood);
Lap Seam placed near center of specimen; ASTM D 1970 Pass Pass
Cond. 24h @ ambient;
Test 5inw.c. @ 40t5°F for 3d;
Visual Inspection for water infiltration
Bottom Can; [WaterlNo Water] No Water No Water
Underside of Plywood; [Water/No Water] No Water No Water
In the Lap Seam; [WaterlNo Water] No Water No Water
Between Plywood &Underlayment; [Water/No Water] No Water No Water
Physical Requirement's—Other
Pass=
Unrolling [Pass/Fail]
4 specimens; 10t1/8" x 18t1/8" "shall n crack
p be so sttickyy a as s to
Cond. 24h @ 73.4t3.6°F &50f5%RH; ASTM D 5636/ Pass cause tearing or
Test Cond. 2h @ Tempt1°F; ASTM D 5147/ other damage upon
Test unroll in 4-6s; ASTM D 1970 being unrolled at
inspection in"unrolled" position temps between 40
Visual Ins
P and 140°F"
Note(s) 1- None
GGI 178 02 02 PRI CMT Accreditations IAS TL-189 Miami-Dade 11-0429 05 Florida TST5878:Los Angeles TA24819:CRRC
The test results,opinions.or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated
client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report.
PRI Constnieiion Materials Technologies LLC 6408 Badger Drive Tampa.FL 33610 Tei:813-621-5777 Fax:813.621-5840 --mail:matedalsiesting@pncmtcem 'WebSite:nttp:A%ww.pricmt.com
Gardner Gibson
ASTM D 1970 for
Weather-Armor SB-1 Self-Bond Underlayment
Page 5 of 6
Extended Ex osure Limitation—90d (500hl TAP 110/ASTM D 4798/ASTM D 5147
Property .. Results Requirement
Maximum Load (Ibf/in-width)
5 specimens; 1"x 6"; ASTM D 2523 t
Cond. 2h @ 73.4±3.6°F; ASTM D 1970
Test @ 73.4±3.6°F; Rate =2in/min ±3%
MD 44 >_25
CMD 33 >25
Elongation at Break (modified bitumen portion) (%}
5 specimens; 1"x 6"; ASTM D 2523/
Cond. 2h @ 73.4±3.6°F; ASTM D 1970
Test @ 73.4±3.6°F; Rate=2in/min±3%
MD 10 a 10
CMD 11 >_ 10
Adhesion to plywood (Ibf/ft-width)
5 specimens; 3" x 8" (bonded 3" x 5"to plywood) ASTM D 903/ 44 a 2.0
Cond. 1 h @ 4Q±2°F; ASTM D 1970
Test @ 40±2°F; Rate=2in/min ±3%
Adhesion to plywood (Ibf/ft-width)
5 specimens; 3"x 8" (bonded 3"x 5"to plywood) ASTM D 903/ 29 > 12
Cond. 1 h @ 75±2°F; ASTM D 1970
Test @ 75±2°F, Rate=2in/min ±3%
Low Temperature Flexibility[Pass/Fail]
5 specimens; 1" x 6"
Cond. 2h @-20°F; ASTM D 1970
Test 180±5° over 1°±5% o in 2±1 s @ -20°F;
Visual Inspection in "flexed" position;
Self Sealability (head of water test) on"flexed"specimen
MD No visible signs of
Pass cracking in the
sheet -or- minor
surface cracking
CMD Pass and"pass"head of
water test
Tear Resistance; min; (Ibf)
5 specimens; 3" x 8"with assigned notch; ASTM D 4073/
Cond. 4h @ 74±4°F& 50±5%RH; ASTM D 1970
Test @ 74±4°F; Rate=2.Oin/min±3%
MD 67 >_20
CMD 60 >20
GGI-178-02-02 PRI-CMT Accreditahons:1AS TL-189:Miami-Dade 11-0429 05 Florida TST5878 Los Angeles TA24819 CRRC
The test results,opinions.or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated
client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory, PRI Construction Materials Technologies LLC assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report.
PRI Cons!roction Materials Technologies LLC 540E Badger Dnve Tampa,=L 33610 Tel:813-621-5777 Fax:813-621.5840 a-mail:materalstesting@pncmt.com 'NebSite:bttp:GWww.pricmLcam
Gardner Gibson
ASTM D 1970 for
Weather-Armor SB-1 Self-Bond Underlayment
Page 6 of 6
Statement of Compliance: The product tested complies with ASTM D 1970: Standard Specification for
Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep
Roofing Underlayment for Ice Dam Protection and has demonstrated an
exposure limitation of 90 days.
Signed: - Signed:
son Slmm ns uc T.Nguyen
Direc
~.,._. -tor Florida Registered Professional Engineer
PE No.:65034
Date: . Date:
�i
IN
4. 0 65034
Report Issue History: ' ;� ;A`I E O F h
Issue# Date Pages Revision Description (if applicable)
Original 01/26/2018 6 NAB
END OF REPORT
GGI-178-02-02 PRI-CMT Accreditations IAS TL-189 Miami-Dade 11-0429 05 Florida TST5878:Los Angeles TA24819:CRRC
The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated
client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report.
PRI Constni0on Materials Technologies LLC 6408 Badger Drive Tampa;FL 33610 Tel:813.621-5777 Fax:813-621.5840 e-mail:matenalstesting@pricmccom NebSite:http:/^~.pricmt.com