Loading...
HomeMy WebLinkAboutProduct Approval - underlayment Florida Building Code Online Page 1 of 3 Business ' 0 Professional Regulation SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publ�ti L/Co s IS Site Mao Links Search Product Approval ra oUSER:Public User lj(v , ,H<v REVIEWED FOR Product Aobroval Meru>Product cr Application Search>Application Lisl>Application Dltaq FL# FL25974-R1 CODE COMPLIANCE Application Type Editorial Change ST■ L IE COU T F Code Version Denied OCC �� Application Status Denied Comments Archived Product Manufacturer APOC,Sub of Gardner-Gibson Inc. Address/Phone/Email 4161 E. 7th Avenue Tampa,FL 33605 (813)248-2101 akhan@gardner-gibson.com Authorized Signature Amir Khan akhan@gardner-gibson.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 03/28/2023 Validated By Locke Bowden P.E. d Validation Checklist- Hardcopy Received Certificate of Independence FL25974 R1 COI Certificate of Independence.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4533 2015 TAS 103 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL25974 R3 Epuiv Equivalency Letter.odf Product Approval Method Method 1 Option B Date Submitted 12/20/2019 file:///C:/1Jsers/ISENHO-1/AppData/Local/Temp/Low/ORYJI415.htm 4/28/2021 Florida Building Code Online Page 2 of 3 Date Validated 12/27/2019 Date Pending FBC Approval 01/13/2020 Date Denied 04/07/2020 Summary of Products FL# Model,Number or Name Description 25974.1 CX-L High strength hybrid underlayment comprised of two layers of polyolefin and polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25974 R1 II CX-L Crossover GGI-176-02-01 Report Rev Approved for use outside HVHZ:Yes 2-ASTM D 226 and D 1970 partial for synthetic Impact Resistant:N/A underlavment.odf Design Pressure:N/A Verified By: PRI Construction Materials Technologies,LLC Other: Test Reports FL25974 R1 TR CX-L Crossover GGI-176-02-01 Report Rev 2=A�M D 226 dnd D_1.97.Q_p�rtial__f�r_synthe..tic underlavment.odf 25974.2 FT3 Self-adhering membrane composed of elastic polymers, bitumen polyester and glass reinforcement. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25974 R.1 I) FT3 GGI-195-02-02 Report-ASTM D 1970- Approved for use outside HVHZ:Yes 09.:pdf Impact Resistant: N/A FL25974 R1 II FT3 GGI-196-02-01 Report-TAS 103.Ddf Design Pressure:N/A Verified By: PRI Construction Materials Technologies,LLC Other: Test Reports F_L259,74__Ri,,,_TR.,._F"_3 GGI-195.-02.-02_Repart„_=ASTM D._197.0_-. 09.odf FL25974 R1 TR FT3 GGI-196-02-01 Report-TAS 103.pdf 25974.3 GatorSkin Synthetic roof underlayment comprised of layers of polyolefin film. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25974 R1 II Gator5kin GGI-132-02-06 Report-ASTM D Approved for use outside HVHZ:Yes 226 FBC 1.507-1-1 for Gator Skin.odf Impact Resistant: N/A Verified By: PRI Construction Materials Technologies,LLC Design Pressure:N/A Test Reports Other: FL25974 R1 TR GatorSkin GGI-132-02-06 Report-ASTM D 226 FBC 1507-1-1 for Gator Skin.Ddf 25974.4 HT3 Self-adhering membrane composed of elastic polymers, bitumen,glass reinforcements and a cross laminated sheet surfacing. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25974 R1 tI HT 3 GGI-194-02-01.3 HT3 ASTM D Approved for use outside HVHZ:Yes 19 7(, jp Impact Resistant: N/A Verified By: PRI Construction Materials Technologies,LLC Design Pressure:N/A Test Reports Other: FL25974 R1 TR HT 3 GGI-194-02-01.3 HT3 ASTM D i9%O,,pdf 25974.5 SB-1 Glass fiber reinforced,polymer modified asphalt,granulated self-adhered underlayment. Limits se Installation Instructions p roved for use in HVHZ:Yes FL25974 R1 tI SB-1 GGl 178 02 O1 ASTM D1970 90 Approved for use outside HVHZ:Yes day.odf Impact Resistant:N/A Verified By: PRI Construction Materials Technologies,LLC Design Pressure:N/A Test Reports Other: FL25974 R1 TR SB-1 GGI-173-02-01 ASTM D1970 90 day,x1f Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: W1 file:///C:/Users/ISENHO—I/AppData/Local/Temp/Low/ORYJ1415.htm 4/28/2021 CONSTRUCTION MATERIALS TECHNOLOGIES LABORATORY TEST RESULTS Report for: Gardner Gibson Attention: Matt Mullins 4146 E. 711,Avenue Tampa, FL 33605 Product Name(s): Weather-Armor SB-1 Self-Bond Manufacturer: Gardner Gibson Roof Underlayment PRI-CMT Project No.: GGI-178-02-01 Source: See Sampling Section GGI-178-02-02 Date Received: See Sampling Section Dates Tested: Sept. 29, 2016—Oct. 21, 2016 Oct.25, 2017—Nov. 28, 2017 Purpose: Determine specification properties for Gardner Gibson's Weather-Armor SB-1 Self-Bond Underlayment for compliance with ASTM D 1970: Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for ice Dam Protection. Gardner Gibson's Weather-Armor S8-1 Self-Bond Underlayment is a granule surfaced, self-adhering, waterproofing underlayment. Testing for Extended Exposure for 90d was conducted in accordance with Miami-Dade County RER Product Control. Test Methods: Testing was completed as described in ASTM D 1970-15: Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection. Test methods assigned or referenced include ASTM D 903: Standard Test Method for Pee/or Stripping Strength of Adhesive Bonds,ASTM D 1204:Standard Test Method for Linear Dimensional Changes of Nonrigid Thermoplastic Sheeting or Film at Elevated Temperature,ASTM D 2523: Standard Practice for Testing Load-Strain Properties of Roofing Membranes, ASTM D 4073: Standard Test Method for Tensile-Tear Strength of Bituminous Roofing Membranes, ASTM D 5147: Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material, and ASTM E 96: Standard Test Methods for Water Vapor Transmission of Materials. Sampling Information: Samples were received from Tampa, FL. Product Source Date Weather-Armor SB-1 Tampa,FL September 14,2016 Weather-Armor S13-1 Tampa,FL September 17,2017 GGI-178-02-02 PRI-CMT Accreditations:IAS TL-189 Miami-Dade 11-0429.05:Florida TST5878 Los Angeles TA24819:CRRC The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Constrocion Materials Technologies LLC 6408 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813.621-5840 a-rr.ail:materaistesfing@phcmt.com WebSite.http:Nwew,pncmt.com Gardner Gibson ASTM D 1970 for Weather-Armor SB-1 Self-Bond Underlayment Page 2 of 6 Results of Testing: ASTM D 1970 Property .. Requirement— Physical Requirements Thickness; min; (mils) 1 specimen; 27-1/2"x manufacture width; ASTM D 5147 72 >_40 5 measurement points Maximum Load (Ibf/in-width) 5 specimens; 1"x 6'; ASTM D 2523/ Cond. 2h @ 73.4t3.6°F; ASTM D 1970 Test @ 73.4t3.6°F; Rate=2in/min t3% MD 61 a 25 CMD 42 z 25 Elongation at Break (modified bitumen portion) (%) 5 specimens; 1"x 6"; ASTM D 2523! Cond. 2h @ 73.4t3.6'F; ASTM D 1970 Test @ 73.4t3.6°F; Rate=2in/min t3% MD 15 >_ 10 CMD 20 10 Adhesion to plywood (Ibf/ft-width) 5 specimens; 3" x 8" (bonded 3" x 5"to plywood) ASTM D 903/ 6.2 z 2.0 Cond. 1 h @ 40t20F; ASTM D 1970 Test @ 40t2°F; Rate=2in/min t3% Adhesion to plywood(Ibf/ft-width) 5 specimens; 3" x 8" (bonded 3" x 5"to plywood) ASTM D 903/ 15 >_ 12 Cond. 1h @ 75t2°F; ASTM D 1970 Test @ 75t2°F; Rate= 2in/min t3% Continued on following page GGI-178-02-02 PRI-CMT Accreditations IAS TL-189 Miami-Dade 11-0429.05 Florida TST5878:Los Angeles TA24819:CRRC The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the clients permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Cnstmction Materials Technologies LLC 6408 Badger Drive Tampa.FL 33610 Tel:813-621 177 Fax.813-621-5840 e-mail:matedalstesting@pricmt.com Web&W http:i,Www.pricmt.com Gardner Gibson ASTM D 1970 for Weather-Armor SB-1 Self-Bond Underlayment Page 3 of 6 MethodProperty Test Requirement Thermal Stability-Type 2 (in) 5 specimens; 4" x 4" (bonded to plywood); ASTM D 1204/ -0 < 0.1 Test 14d @ 203t3.6'F; ASTM D 1970 Equilibrate to 75t20F &50t5%RH for 4h; Low Temperature Flexibility(PasslFail] 5 specimens; 1" x 6" Cond. 2h @-20'F; ASTM D 1970 Test 180±5'over V±5% o in 2t1s @-20'F; Visual Inspection in"flexed" position: Self Sealability(head of water test)on"flexed" specimen No visible signs of cracking in the MD Pass sheet -or- minor surface cracking and"pass"head of water test No visible signs of cracking in the CMD Pass sheet -or- minor surface cracking and"pass"head of water test Tear Resistance; min; (lbf) 5 specimens: 3" x 8"with assigned notch; ASTM D 4073/ Cond. 4h @ 74t4'F & 50f5%RH; ASTM D 1970 Test @ 74t4'F; Rate=2.Oinlmin t3% MD 86 >_20 CMD 64 >_20 Moisture Vapor Permeance (U.S. Perms) 3 specimens; 3.5" o; ASTM E 96 0.02 s 0.1 Weathering side to higher vapor pressure; Procedure BW Test @ 73.4t3.6'F & 50t5%RH Self-Sealability[Pass/Fail] 2 specimens; 12" x 12" (bonded to plywood); ASTM D 1970/ ASTM D 3462 single thickness intervening material; ASTM D 7349 Two 1-1/4" roofing nails placed near center of specimen; Pass Pass Cond. 24h @ ambient; Protocol 4 Test 5inw.c. @ 40t50F for 3d; (modified) Visual Inspection for water infiltration Bottom Can; [WaterlNo Water] No Water No Water Nail Shank; [WaterlNo Water] No Water No Water Underside of Plywood; [Water/No Water] No Water No Water Between Plywood & Underlayment; [WaterlNo Water] No Water No Water Continued on following page GGI-178-02-02 PRI-CMT Accreditations IAS TL-189 Miami-Dade 11-0429 05 Florida TST5878 Los Angeles TA24819:CRRC The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Construction Materials Technologies LLC 6408 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:81 M21-5840 e-mail materialstestingCpricmt.com WebSite:http:1w m.pncmtcom Gardner Gibson ASTM D 1970 for Weather-Armor SB-1 Self-Bond Undedayment Page 4 of 6 Property •• •• Self-Sealability; After Low Temp Flexibility[Pass/Fail] 2 specimens, Low Temperature Flexibility specimen; ASTM D 1970 Pass Pass Cond. 24h @ ambient; Test 5inw.c. @ 40t5°F for 3d; Visual Inspection for water infiltration Bottom Can;[Water/No Water] No Water No Water Nail Shank; [Water/No Water] No Water No Water Underside of Plywood; [Water/No Water] No Water No Water Between Plywood &Undedayment; [Water/No Water] No Water No Water Self-Sealability; Lap Seam [Pass/Fail] 2 specimens- 12"x 12" (bonded to plywood); Lap Seam placed near center of specimen; ASTM D 1970 Pass Pass Cond. 24h @ ambient; Test 5inw.c. @ 40t5°F for 3d; Visual Inspection for water infiltration Bottom Can; [WaterlNo Water] No Water No Water Underside of Plywood; [Water/No Water] No Water No Water In the Lap Seam; [WaterlNo Water] No Water No Water Between Plywood &Underlayment; [Water/No Water] No Water No Water Physical Requirement's—Other Pass= Unrolling [Pass/Fail] 4 specimens; 10t1/8" x 18t1/8" "shall n crack p be so sttickyy a as s to Cond. 24h @ 73.4t3.6°F &50f5%RH; ASTM D 5636/ Pass cause tearing or Test Cond. 2h @ Tempt1°F; ASTM D 5147/ other damage upon Test unroll in 4-6s; ASTM D 1970 being unrolled at inspection in"unrolled" position temps between 40 Visual Ins P and 140°F" Note(s) 1- None GGI 178 02 02 PRI CMT Accreditations IAS TL-189 Miami-Dade 11-0429 05 Florida TST5878:Los Angeles TA24819:CRRC The test results,opinions.or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Constnieiion Materials Technologies LLC 6408 Badger Drive Tampa.FL 33610 Tei:813-621-5777 Fax:813.621-5840 --mail:matedalsiesting@pncmtcem 'WebSite:nttp:A%ww.pricmt.com Gardner Gibson ASTM D 1970 for Weather-Armor SB-1 Self-Bond Underlayment Page 5 of 6 Extended Ex osure Limitation—90d (500hl TAP 110/ASTM D 4798/ASTM D 5147 Property .. Results Requirement Maximum Load (Ibf/in-width) 5 specimens; 1"x 6"; ASTM D 2523 t Cond. 2h @ 73.4±3.6°F; ASTM D 1970 Test @ 73.4±3.6°F; Rate =2in/min ±3% MD 44 >_25 CMD 33 >25 Elongation at Break (modified bitumen portion) (%} 5 specimens; 1"x 6"; ASTM D 2523/ Cond. 2h @ 73.4±3.6°F; ASTM D 1970 Test @ 73.4±3.6°F; Rate=2in/min±3% MD 10 a 10 CMD 11 >_ 10 Adhesion to plywood (Ibf/ft-width) 5 specimens; 3" x 8" (bonded 3" x 5"to plywood) ASTM D 903/ 44 a 2.0 Cond. 1 h @ 4Q±2°F; ASTM D 1970 Test @ 40±2°F; Rate=2in/min ±3% Adhesion to plywood (Ibf/ft-width) 5 specimens; 3"x 8" (bonded 3"x 5"to plywood) ASTM D 903/ 29 > 12 Cond. 1 h @ 75±2°F; ASTM D 1970 Test @ 75±2°F, Rate=2in/min ±3% Low Temperature Flexibility[Pass/Fail] 5 specimens; 1" x 6" Cond. 2h @-20°F; ASTM D 1970 Test 180±5° over 1°±5% o in 2±1 s @ -20°F; Visual Inspection in "flexed" position; Self Sealability (head of water test) on"flexed"specimen MD No visible signs of Pass cracking in the sheet -or- minor surface cracking CMD Pass and"pass"head of water test Tear Resistance; min; (Ibf) 5 specimens; 3" x 8"with assigned notch; ASTM D 4073/ Cond. 4h @ 74±4°F& 50±5%RH; ASTM D 1970 Test @ 74±4°F; Rate=2.Oin/min±3% MD 67 >_20 CMD 60 >20 GGI-178-02-02 PRI-CMT Accreditahons:1AS TL-189:Miami-Dade 11-0429 05 Florida TST5878 Los Angeles TA24819 CRRC The test results,opinions.or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory, PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Cons!roction Materials Technologies LLC 540E Badger Dnve Tampa,=L 33610 Tel:813-621-5777 Fax:813-621.5840 a-mail:materalstesting@pncmt.com 'NebSite:bttp:GWww.pricmLcam Gardner Gibson ASTM D 1970 for Weather-Armor SB-1 Self-Bond Underlayment Page 6 of 6 Statement of Compliance: The product tested complies with ASTM D 1970: Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection and has demonstrated an exposure limitation of 90 days. Signed: - Signed: son Slmm ns uc T.Nguyen Direc ~.,._. -tor Florida Registered Professional Engineer PE No.:65034 Date: . Date: �i IN 4. 0 65034 Report Issue History: ' ;� ;A`I E O F h Issue# Date Pages Revision Description (if applicable) Original 01/26/2018 6 NAB END OF REPORT GGI-178-02-02 PRI-CMT Accreditations IAS TL-189 Miami-Dade 11-0429 05 Florida TST5878:Los Angeles TA24819:CRRC The test results,opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Constni0on Materials Technologies LLC 6408 Badger Drive Tampa;FL 33610 Tel:813.621-5777 Fax:813-621.5840 e-mail:matenalstesting@pricmccom NebSite:http:/^~.pricmt.com