Mobile Home Inspection Report
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied,by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone II certified.
Owner: Date: ��L,2
�(Print type) Ld S r
Address: 5 —' A C' Ifr/` CL� l� Y 9 YG
(Physical Location of Home)
Year / Manufacturer
Serial # J r
Q % 3 HUD Plate 4jS I J JLA)1
Ti
wl�iif t
�, +S -7
,.
th Length / Single Double
C = In Compliance N = Not in Compliance
Fire Safety / Electrical
�L 1. Smoke Detector: Installed_ Missing
^r], 2. Electrical System -Checked: Exposed Wiring Other.
Wind Zone_=
_ 3. Distribution Panel: Missing Loose Main Missing Breaker Missing
Unplugged Opening Other
C 4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire
GFCI receptacles not where required
5. Electrical Ground: Chassis Main Panel Gas Pipe
k',: •`sed 319105
FILh-
CO�f7
Construction
1. Exit Doors Operable: Front' Back Other
2. Exit Door Locks: Missing Inoperable
4. Windows: Broken Glass Inoperable
5. Screens:. Missing Damaged
6. Floor System: Joist Decking Area Damaged
C 7. Interior Paneling: Missing Loose Damaged 4
8. Rodent Proofing: Bottom Board Pipe openings Other
t� 9. Leaks Apparent: Ceiling Doors Floor Roof
10. Vertical tie -down straps: Missing Short Damaged
C 11. Structural modifications since manufactured: YES_ NO_
�L 1.2. Walls: Structurally Unsound Loose Weather tight
Plumbing
1. Trap: Missing Not connected Other
2. Plumbing fixtures: Missing Not installed Not Vented
C3. Relief Valve: Missing Inoperable Other
G 4. Drain Waste and Venting Piping: Missing Not supported
Clean outs Use of fittings Not capped
I
i
Heating and Air Conditioning
G1. Heating Appliances: Missing Not Connected Other
2. Deleted Heating/AC system: Not installed Y n tailed Other
3. Thermostat: Missing Inoperable
4.•Air registers: Missing Inoperable
5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
Lh
w.mJ1"NY
D� 6. Gas furnace Water heater vent: Missing Loose
7. Return Air: To Furnace To A/C From rooms
8. Range: Vent Hood
G9. Gas Valve: Accessible Installed improperly
G10. Gas lines: Not capped Not supported Kinked
Not bonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO�
2. Will a remodeling permit be required? YES NO_
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
ited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQU4RED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected: I toe,
Inspected By:6rc--U c:
Signature required
Phone Number: (17z 07b 73a�
i
License # 3 �s Q) ,
rI,
FL I:I�CENSIE44398
8ti0 St<TLTyDR
PORT ST LUCIE, FL
/o�ai�o�
Engineers Seal