Loading...
HomeMy WebLinkAboutMobile Home Inspection Report` St Lucie Countv Building & Zoning 2300 Virginia Avenue Ft Pierce. FL ' 4982 0 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home, All used MobiWhomes must be Wind Zone II certified, Owner: (!fo4.C)N V Date: 13olo-I (Print or type) Address: ��D Iy . 0. 5• 1 V f % t�gg . r�— (Physical Location of Home) Year / Manufacturer HRI� Q(,c)/� Serial # OcIL 2.4'tQ8 HUD Plate # &60 7J�j7 S I It (, th / Length-5—!L_ Single V Double Wind Zone_ C = In Compliance •N = Not in Compliance RRL PAlFZai31.,C Fire Safety / Electrical 1. Smoke Detector: Installed Missing 2. Electrical System Checked: Exposed Wiring Other 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other _ 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire CGFCI receptacles not where required 5. Electrical Ground: Chassis Main Panel Gas Pipe 4 Zo.ised 319105 Page 1 of 3 Construction 1. Exit Doors Operable: Front Back Other C 2. Exit Door Locks: Missing Inoperable 3 EgPeSS Misffiflg ;,,;N c, pbl, M_ 4. Windows: Broken Glass Inoperable C_ 5. Screens: Missing Damaged _1� 6. Floor System: Joist Decking Area Damaged —C 7. Interior Paneling: Missing Loose Damaged 8. Rodent Proofing: Bottom Board Pipe openings Other 9. Leaks Apparent: Ceiling ;Doors Floor Roof C 10. Vertical tie -down straps: Missing Short Damaged C 11. Structural modifications since. manufactured: YES_ NO W` _(L 12. Walls: Structurally Unsound Loose Weather tight Plumbing 1. Trap: Missing Not connected Other C 2. Plumbing fixtures: Missing Not installed Not Vented C 3. Relief Valve: MissingInoperable Other 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning C 1. Heating Appliances: Missing Not Connected Other 6 2. Deleted Heating/AC system: Not installed Other 3. Thermostat: Missing Inoperable 4. Air registers: Missing Inoperable 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 1 6. Gas furnace Water heater, vent: Missing Loose 7. Return Air: To Furnace To A/C From rooms G8. Range: Vent Hood iJf 9. Gas Valve: Accessible Installed impro erl P Y 10. Gas lines: Summary Not capped Not supported Kinked Notbonded I. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO 2. Will a remodeling permit be required? YES N0�_ The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be. ited to, standards for structural adequapy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIOINAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected:-7/3 7 nspected By: ! • C. License # =y'z = Signature required 'hone Number: O13�L�' Paae73 of F i L 'ti, STn%fq G. D, P.E. Engineers Seal Cr