Loading...
HomeMy WebLinkAboutSurvey.11 J -- — — — —— PROPO -PATER-SERI I I I I i -LOT 8 VACANT I I C I C I C I K I � f 0 M O Z GNR SIDLi I k iADZ i 6 D.E. zNJO. I I TE(;H I I I I 1 I — I I I I I THOMAS P. KIERNAN Professional Surveyor & Mapper Florida Certificate No. 6199 WMT-2 DATE A=9'27'03" L=83.30' PROPOSED ' SANITARY ` SERVICE F (SE NOTE 17, LOMR— LOM� (SEE NOTE 0— L E C 0P,,Y PROPERTY ADDRESS 3323 HOMESTEAD DRIVE, FORT PIERCE, FLORIDA LEGAL DESCRIPTION Being all of Lot 7, according to the plat of CREEKSIDE PLAT NO. 4, as recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida. Containing 0.217 acres, more or less. LEGEND & ABBREVIATIONS BB DENOTES BEARING BASE CBS DENOTES CONCRETE BLOCK STRUCTURE C DENOTES CHORD BEARING do DISTANCE DENOTES CENTER LINE D.E. DENOTES DRAINAGE EASEMENT F.F.E. DENOTES FINISH FLOOR ELEVATION FND DENOTES FOUND IR/C DENOTES IRON ROD AND CAP L.B. -DENOTES LICENSED BUSINESS L DENOTES ARC LENGTH N/D DENOTES NAIL AND DISK O.S.T. DENOTES OPEN SPACE TRACT P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR R DENOTES RADIUS R/W DENOTES RIGHT OF WAY U.E. DENOTES UTILITY EASEMENT W.M.T. DENOTES WATER MANAGEMENT TRACT A DENOTES INCLUDED ANGLE DENOTES DRAINAGE FLOW DENOTES PROPOSED ELEVATION �( DENOTES FIRE HYDRANT DENOTES SANITARY MANHOLE GRAPHIC SCALE 20 0 10 20 (IN7) 1 IDAh - 20 & GENERAL NOTES 1. The lost date of field work was 5-14-20 2. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 3. Reproductions of this map are not valid without the original signature and raised seal of a Florida Licensed Surveyor and Mapper. 4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information should be obtained through appropriate title verification. 5. All above ground fixed improvements, if any, have been located and shown hereon. 6. Underground foundations and improvements were not located as part of this survey. 7. Flood Note: By graphic plotting only, the portion of this property scheduled for building improvements is in Zone "X", according to the LOMA Case No. 21-04-138A associated to the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February 16, 2012. The exact designation can only be determined by an elevation certificate. There may be additional map Amendments affecting this property. 8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of existing field elevation data. 9. The bearings shown hereon are based on Plat information and are referenced to the.*line of Lot 7 which bears North 10'39'11" West and all bearings are relative thereto. 10. No easements are shown hereon other than those depicted on the plat. No search of the public records has been performed to find additional easements that may exist. 11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988. 12. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior to design or construction. Boundary, Topographic & Site Plan Survey -Lot 7 For: D. R. HORTON �r CULPEPPER & Date:02-12-202115-141.004;0 Date: 02-12-2021 FB: N/A TERPENING INC SCALE 1 "=20' DRAWN BY: RMR M. 2980 SOUTH 25th STREET • FORT PIERCE, FLORIDA 34981 PHONE 772-464-3537 • FAX 772464-9497 • www.et-eng.com FIELD: PK STATE OF FLORIDA BOARD OF PROFESSIONAL ENGINEERS AUTHORIZATION NO.4286