Loading...
HomeMy WebLinkAbout213055-1d compaction REVISED - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE REVISED: DATE TESTED:KSM JOB #:213055-1d/JM/ah PERMIT #:NUC #215 CONTRACTOR:Adams Homes Nuc Model:MC-1DR-P JOB LOCATION:5356 Vespera Street Nuc Serial #:MD80404215 Lot 26-5, Waterstone Ft. Pierce, Florida ITEM TESTED:Compacted Foundation Fill TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.W.0" - 12"14D 109.9 113.1 97.2% 2. N.E."13D 108.8 "96.2% 3. Center "14D 110.3 "97.5% 4. S.E."13D 108.9 "96.3% 5. S.W."14D 109.6 "96.9% Soil Description: Brown Sand with Some Clay and Traces of Shell Fragments In Place Moisture: 8.8% Proctor Optimum Moisture: 13.0% Proctor Max. Dry Density: P.C.F. 113.1 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 4/29/2021 Email to: St. Lucie County Building Department ; rick.johnson@adamshomes.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 April 23, 2021 21020117 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. April 29, 2021 Proudly Serving Florida since 1990 109.0 110.0 111.0 112.0 113.0 114.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight