Loading...
HomeMy WebLinkAboutEngineer Report 04132021, 4.29.21BREITENBACH ENGINEERING, INC johnbach442@gmail.com 4853 SE Pilot Way, Stuart, Florida 34997 Cell: (772) 834-4743 April 13, 2021 To: Building Official, St. Lucie County, Building Division 2300 Virginia Avenue, Fort Pierce, Florida 34982 Re: Specialty Building Inspections for Threshold Building Permit #SLC 2008-0353 Project: PT Cable repair and replacement of stair well doors The Admiral Condo Attn: Lisa Kusen lisak@advpropmgt.com 8750 S. Ocean Drive, Jensen Beach, FL 34957 772-408-7538 General Contractor: Daniello Attn: Chris Arias 561-352-4280 2708 N. Australian Ave, West Palm Beach, FL 33407 Building Official: This letter is to inform you as threshold building special inspector, John Breitenbach PE 59770, SI #2072 that the Contractor, to the best of my knowledge, has successfully completed the Post Tension Cable Repair and the Door replacements as outlined in the Plans and Specifications of CSM Engineers, dated July 2020. The inspection log is attached. Should you have any questions, please contract me. Respectfully, �rErtrrr,,, "'0 , FLURV�3. aC� <'SS rr. John D. Breitenbach, PE FL PE #59770, FL SI #2072, Firm Reg. #26001 (2)-copies to Contractor, (1)-copy to CSM, (1)-copy to Condo Assoc file= 20033-8-Admiral 7-24-20 Admiral Letter of Intent.doc 20033-8-Admiral [Breitenbach Engineering, Int, fel: 772-834-4743 iohnbach442(a)gmail.con 4R53 SE Pilot Wpv, Stuir#, F!.. 349917 Attention: e-mail: Lisa Kuser, Condo Assoc: The Adr- ral Condo Assoc 18750 S Ocean Drive Jensen Beach, FL 34957 By: John D. Breitenbach, �' PE #59770 SI #2072 Permit Number: SLC 2008-0353 Job Number: 20033-8 p mgt. co m 772-408-7538 Contact: F�� hris Arias Contractor: 7anbiello Constructic� Address: �2708 N Australian Ave, WPB, FL 334iN Australian Ave, WPB, FL 334C 'el: 772-834-4743 Gate Code: ! none ohnbach442(Q_gmaiLcom Billing Method: Hourly Date fours Mr) rrinti01?V T,rnp Cnmr—..c-nts P^ —/Fail 7/13/20 2.00 Meeting, teleconferenc n.a. 7/24/20 1.00 Letter of Intent n.a. 9/15/20 1.50 PT cable Wed 2:00 Observe tensioning, calibration, 33 k (see attached) passed 9/16/20 1.0C report, certification set up forms n.a. and ing iron I jAdministrative, reports & mailing 11/2/20 1.50 stair tower doors Mon 11:301 Floors 17-9, see memo progress 11/16/20 1.00 doors Floors 16,15 passed 4/9/21 all doors passed 4/12/21 1.00 final completion letter n.a. 4/12/2- Administrative, reports & mailing n.a. of NoverW - Administrative, reports & mailing Inspection..: re perfon ' by the special inspector per the permitted plans anu sons a..ording to the International C Repair Institute (ICRI). Th= '`tC and ACI-318 do not address concrete restoration. and County forms are not legal per law. Total Hrs: 9.00 See Letter of Intpnt and the Engineer's Plans & Specifi;•ations for additional information. Send via: [ ] e-mail [ x ] U.S. Mail [ ] Contractor [ x ] CSM Engineers [ ] Cond file = c:112019-ProjectslCSM ovote: Contracior responswie Tor piing with buetia��` �� 20033-8-Admiral N 5 .0' A'fl='�Fto '1p,Hfilllil110A