HomeMy WebLinkAboutFL19901_R4_C_CAC_Intertek Listing Reveal PanelReport prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
ntertek
Total Quality. Assured.
AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in
accordance with the conditions set forth in the Certification Agreement and Listing ReporL(s). This authorization also applies to the Multiple Listee
model(s) identified on the correlation page of the Listing Report.
This document is the property of Intertek Testing Services and is not transferable. The Certification Mark(s) may be applied only at the location of the Party
Authorized to Apply Mark.
Applicant:
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
United States
Contact:
Benjamin Batres
Phone:
909-841-4109
Fax:
909-427-0634
Email:
benjamin.batres@jhresearchusa.com
Party Authorized to Apply Mark:
See following page(s)
Evaluation Center:
Intertek (Coquitlam)
Client Number:
205963
Authorized By:
Jean -Philippe Kayl, airectorofCertificabon
Intertek Testing Services NA, Inc_
545 E. Algonquin Road, Ste H., Arlington Heights, IL 60005 USA
Phone: 947-43MC36T Fax: 547-439-7320
COTTus
Intertek
This document supersedes all previous Authorizations to Mark for the noted Report Number.
This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to
the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of
this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the
conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in
writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the
purposes of production quality control and do not relieve the Client of their obligations in this respect.
Testing Standard(s):
CAN / ULC S101 (2007), CAN / ULC S114 (2005), CAN / ULC S102
(2010), AAMA 509 (2009), ASTM E136 (2012), CAN / ULC S101
(2014), ASTM E84 (2016), ASTM E136 (2016) Ed. 16a, ASTM E119
(2016), ISO 8336:2017 Ed.3, ASTM E84 (2015), ASTM E119 (2015),
ASTM E330 (2014), ASTM C1186-08 (2012), ISO 8336 (2009), EN
12467:2012 +A1
Product:
James Hardie 7/16" Panel Siding
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 1 of 20
ATM for Report: G 101575558; G 102753016; G 100461561; ATM Issue Date: 1 /19/2021
G100844583; G101505709;G101414684; G10247028;G102477668;
G102573914; G3180889; Building Products, Inc.) on 1/19/2021 1:38:38 PM
G103112417, G102753016, G103942655, G103470658,G104368432
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 2 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
Listing Section(s): WALL ASSEMBLIES
CSI Code(s): 07 46 00 Siding
Description:
James Hardie Reveal® and Pressed Reveal® are fiber cement panel sidings.
Product
IDimensions
Weight
Width: 48 in.
Reveal®
Length: 96 in.
3.1 Ibs/ft
(Thickness:
7/16 in.
Width: 48 in.
Pressed Reveal®
Length: 96 in.
4.3 Ibs/ft
Thickness: 7/16 in.
PHYSICAL RATINGS
Product
Standard
Rating
Reveal® and Pressed Reveal®
Panel Sidings
STM C1186
Meets Grade II, Type A
BS EN 12467
Meets Category A, Class 2, Level I
ISO 8336
Meets Category A, Class 2, Level I
FIRE RATINGS
Product
Standard
Rating
IDesign Listing Number
Reveal® and Pressed
Reveal® Panel Sidings
ASTM E136
Non-combustible
IN/A
CAN/ULC S114
Non-combustible
N/A
ASTM E84
Flame Spread Index: 0
Smoke Developed Index:
0
N/A
CAN/ULC S102
Flame Spread Index: 0
Smoke Developed Index:
5
N/A
ASTM E119
CAN/ULC S101
1 Hour
JH/FCS 60-01
JH/FCS 60-02
JH/FCS 60-03
JH/FCS 60-04
2 Hours
JH/FCS 120-01
JH/FCS 120-02
STRUCTURAL RATINGS
Structural rating for Reveal® and Pressed Reveal® Panel Sidings per ASTM E330:
m No
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 3 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
Results:
Ultimate Load: 127.4 psf
Details:
• Framing: 20 GA Steel (nominal 2x4)
• Stud spacing: 16 in. on center
• Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in.
head diameter, 0.121 in. shank diameter
• Fastener spacing: 3 fasteners at 16" o.c
System No.
#2
Results:
Ultimate Load: 99.5 psf
Details:
• Framing: 20 GA Steel (nominal 2x4)
• Stud spacing: 24 in. on center
• Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in.
head diameter, 0.121 in. shank diameter
• Fastener spacing: 3 fasteners at 16" o.c
System No.
#3
Results:
Ultimate Load: 128.5 psf
Details:
• Framing: 20 GA Steel (nominal 2x4)
• Stud spacing: 16 in. on center
• Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in.
head diameter, 0.121 in. shank diameter
• Fastener spacing: 4 fasteners at 12" o.c
System No.
#4
Results:
Ultimate Load: 111.3 psf
Details:
• Framing: Wood nominal 2x4 SPF #2+BTR
• Furring: Treated % in. x 4 in.
• Stud spacing: 16 in. on center
• Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in.
head diameter, 0.121 in. shank diameter
• Fastener spacing: 3 fasteners at 16" o.c
System No.
#5
Results:
Ultimate Load: 110.1 psf
Details:
• Framing: Wood nominal 2x4 SPF #2+BTR
• Furring: Treated % in. x 4 in.
• Stud spacing: 24 in. on center
• Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in.
head diameter, 0.121 in. shank diameter
• Fastener spacing: 3 fasteners at 16" o.c
System No.
#6
Results:
Ultimate Load: 134.4 psf
Details:
• Framing: Wood nominal 2x4 SPF #2+BTR
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 4 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
•
Furring: Treated 1/4 in. x 4 in.
•
Stud spacing: 16 in. on center
•
Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in.
head diameter, 0.121 in. shank diameter
•
Fastener spacing: 4 fasteners at 12" o.c
System No.
#7
Results:
Ultimate Load: 150 psf
Details:
•
Framing: 20 GA Steel (nominal 2x4)
•
Stud spacing: 24 in. on center
•
Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter,
0.132 in. shank diameter
•
Fastener spacing: 4 fasteners at 12" o.c
System No.
#8
Results:
Ultimate Load: 168.9 psf
Details:
•
Framing: 20 GA Steel (nominal 2x4)
•
Stud spacing: 16 in. on center
•
Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
•
Fastener spacing: 3 fasteners at 16" o.c
System No.
#9
Results:
Ultimate Load: 207.6 psf
Details:
•
Framing: 20 GA Steel (nominal 2x4)
•
Stud spacing: 16 in. on center
•
Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
•
Fastener spacing: 4 fasteners at 12" o.c
System No.
#10
Results:
Ultimate Load: 172.2 psf
Details:
•
Framing: Wood nominal 2x4 SPF #2+BTR
•
Furring: treated 1/4 in. x 4 in.
•
Stud spacing: 24 in. on center
•
Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter,
0.132 in. shank diameter
•
Fastener spacing: 4 fasteners at 12" o.c
System No.
#11
Results:
Ultimate Load: 127.6 psf
Details:
•
Framing: Wood nominal 2x4 SPF #2+BTR
•
Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
•
Stud spacing: 16 in. on center
•
Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
•
Fastener spacing: 3 fasteners at 16" o.c
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 5 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
System No.
#12
Results:
Ultimate Load: 206.2 psf
Details:
•
Framing: Wood nominal 2x4 SPF #2+BTR
•
Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
•
Stud spacing: 16 in. on center
•
Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
•
Fastener spacing: 4 fasteners at 12" o.c
System No.
#13
Results:
Ultimate Load: 137.1 psf
Details:
•
Framing: Wood nominal 2x4 SPF #2+BTR
•
Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
•
Stud spacing: 16 in. on center
•
Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38)
•
Fastener spacing: 2 fasteners at 24" o.c
System No.
#14
Results:
Ultimate Load: 137.1 psf
Details:
•
Framing: Wood nominal 2x4 SPF #2+BTR
•
Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
•
Stud spacing: 16 in. on center
•
Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38)
•
Fastener spacing: 2 fasteners at 24" o.c
Reveal® and Pressed Reveal® Sidings comply with the requirements of AAMA 509 when tested with the
following installation details:
System No.
1
Results:
Meets the requirements of AAMA 509
Details:
• Framing: SPF wood framing, nominal 2 in. x 6 in.
• Furring: 3/4 in. thick x 4 in. wide pressure treated plywood
• Weather Barrier: One layer of Tyvek ® HomeWrap ® installed over framing,
stapled at 24 in. on center
• Fastener Type: Countersunk #8 x 1-5/8 in. long buglehead screws
• Fastener Spacing: 16 in. at o.c
FLORIDA PRODUCT INFORMATION
Product Evaluated
FL No.
James Hardie Reveal® and
Pressed Reveal® Sidings
19901
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 6 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
Party(s) Authorized by Manufacturer To Apply Mark:
James Hardie Building Products, Inc. (Peru, IL)
17 Unytite Drive
Peru, IL 61354
United States
Contact: Doc Walker
Phone: 815-343-5605
Fax: 815-220-3087
Email: Doc.Walker@jameshardie.com
Party(s) Authorized by Other Parties To Apply Mark:
None
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 7 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
DRAWING INDEX
JH/FCS 120-01
JH/FCS 120-02
JH/FCS 60-01
JH/FCS 60-02
JH/FCS 60-03
JH/FCS 60-04
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 8 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 120-01
Lntertek
Total Quality. Assured.
4
6
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
James Hardie Building Products
Design No.1H/FCS 120-01
James Hardie Fiber Cement Siding
Non -Symmetrical, Non -Load -Bearing Wall Assembly
ASTM E119, CAN/ULC 5101
Fire Resistance Rating — 2 Hour (Rating applies to both sides)
1. STEEL STUDS: Min. 3-5/8 in. depth 20 GA
(0.0359 in.) galvanized steel studs, spaced
16 in. on center (oc) max.
2. CAVITY INSULATION (Required): Stud cavities
filled with R12 un-faced fiberglass insulation.
3. GYPSUM WALLBOARD, SIDE A: Two layers of
5/8 in. Type X gypsum board or 5/8 in.
Densglass Gold board, oriented horizontally,
and fastened to the steel studs using 1-5/8 in.
DW screws every 8 in. oc for the first layer and
Date Revised: September 24, 2019 Page 1 of 2
Version: 02 August 2017
3A
2
1
313
2-1/4 in. DW screws every 8 in. oc for the
second layer. All joints and screws covered
with joint compound.
GYPSUM WALLBOARD, SIDE B: Two layers of
5/8 in. Type X gypsum board or 5/8 in.
Densglass Gold board, oriented horizontally,
and fastened to the steel studs using 1-5/8 in.
DW screws every 8 in. oc for the first layer and
2-1/4 in. DW screws every 8 in. oc for the
second layer. All joints and screws covered
with joint compound.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 9 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 120-01 (2 OF 2)
Lon
4. WOOD SHEATHING (Optional): ADDITIONAL
LAYER(S) (Optional): Any one or two of the
following components can be used in any order
outward of the gypsum sheathing (Item 313):
COMPONENT 1 — EXTERIOR INSULATION: The
exterior insulation may be installed up to the
max. thickness and density recognized in the
certification document.
ICC-ES AC377 certified open cell, spray -
applied polyurethane insulation
ASTM C578 certified extruded polystyrene
(XPS) insulation
ASTM C1289 certified polyiso insulation
Mineral wool batt insulation
COMPONENT 2 — WOOD STRUCTURAL PANEL
SHEATHING:
Code prescribed wood structural panel
sheathing
One layer of the wood structural panel
sheathing may also be installed on the interior
of Item 3B.
FURRING (Optional):
Min. 1-1/2 in. wide x 3/8 in. thick furring
(Wood: Min. 0.42 SG; Metal: Corrosion
Resistant min. 20 GA 33 ksi metal hat
channel, z-girt or u-bar), or
Date Revised: September 24, 2019
Version: 02 August 2017
Page 2 of 2
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
Min. 4.574 in. wide x 3/4 in. thick James
Hardie Horizontal Steel Furring installed per
manufacturer's installation instructions
(min. 18 GA 33 ksi metal)
6. CERTIFIED MANUFACTURER: James Hardie
Building Products Inc.
CERTIFIED PRODUCT: HardiePlank® smooth
and textured Lap Siding (HZ5 and HZ10),
CemPlank° Lap Siding, Prevail® Lap Siding,
HardieShingle° smooth and textured (HZ5 and
HZ10), Artisan° Shingle, HardiePanel° Vertical
Siding smooth and textured (HZ5 and HZ10),
CemPanel® Vertical Siding, Prevail'" Panel
Siding, Artisan® Lap Siding, Artisan® V-Groove
Siding, Artisan® Bevel Channel, Artisan® Square
Channel, Artisan® Shiplap Lap Siding, Reveal®,
and Pressed Reveal® sidings.
FIBER -CEMENT EXTERIOR SIDING:
HardiePlank® smooth and textured Lap Siding
(HZ5 and HZ10), CemPlank® Lap Siding, Prevail°
Lap Siding, HardieShingle® smooth and
textured (HZ5 and HZ10), Artisan® Shingle,
HardiePanel° Vertical Siding smooth and
textured (HZ5 and HZ10), CemPanel® Vertical
Siding, Prevail— Panel Siding, Artisan® Lap
Siding, Artisan° V-Groove Siding, Artisan®
Bevel Channel, Artisan® Square Channel,
Artisan° Shiplap Lap Siding, Reveal®, or Pressed
Reveal® sidings installed in accordance with
manufacturer's installation instructions.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 10 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 120-02
Lntertek
Total Quality. Assured.
4
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
James Hardie Building Products
Design No.1H/FCS 120-02
James Hardie Fiber Cement Siding
Non -Symmetrical, Load -Bearing Wall Assembly — Full Design Load
ASTM E119, CAN/ULC 5101
Fire Resistance Rating — 2 Hour (Rating applies to both sides)
6
1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn
wood studs located 16 in. on center (oc), with
top and bottom plates using 3 in. framing nails.
2. INSULATION (Required): Stud cavities filled
with R12 un-faced fiberglass insulation.
3. GYPSUM WALLBOARD: Two layers of 5/8 in.
Type X gypsum board or 5/8 in. Densglass Gold
board, oriented horizontally, and fastened to
the steel studs using 1-5/8 in. DW screws every
8 in. oc for the first layer and 2-1/4 in. DW
Date Revised: September 24, 2019 Page 1 of 2
Version: 02 August 2017
3A
r
1
I
36
5
screws every 8 in. oc for the second layer. All
joints and screws covered with joint
compound.
GYPSUM WALLBOARD, SIDE B: Two layers of
5/8 in. Type X gypsum board or 5/8 in.
Densglass Gold board, oriented horizontally,
and fastened to the steel studs using 1-5/8 in.
DW screws every 8 in. oc for the first layer and
2-1/4 in. DW screws every 8 in. oc for the
second layer. All joints and screws covered
with joint compound.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 11 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 120-02 (2 OF 2)
Lon
4. WOOD SHEATHING (Optional): ADDITIONAL
LAYER(S) (Optional): Any one or two of the
following components can be used in any order
outward of the gypsum sheathing (Item 313):
COMPONENT 1 — EXTERIOR INSULATION: The
exterior insulation may be installed up to the
max. thickness and density recognized in the
certification document.
ICC-ES AC377 certified open cell, spray -
applied polyurethane insulation
ASTM C578 certified extruded polystyrene
(XPS) insulation
ASTM C1289 certified polyiso insulation
Mineral wool batt insulation
COMPONENT 2 — WOOD STRUCTURAL PANEL
SHEATHING:
Code prescribed wood structural panel
sheathing
One layer of the wood structural panel
sheathing may also be installed on the interior
of Item 3B.
FURRING (Optional):
Min. 1-1/2 in. wide x 3/8 in. thick furring
(Wood: Min. 0.42SG; Metal: Corrosion
Resistant min. 20 GA 33 ksi metal hat
channel, z-girt or u-bar), or
Date Revised: September 24, 2019
Version: 02 August 2017
Page 2 of 2
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
Min. 4.574 in. wide x 3/4 in. thick James
Hardie Horizontal Steel Furring installed per
manufacturer's installation instructions
(min. 18 GA 33 ksi metal)
6. CERTIFIED MANUFACTURER: James Hardie
Building Products Inc.
CERTIFIED PRODUCT: HardiePlank® smooth
and textured Lap Siding (HZ5 and HZ10),
CemPlank° Lap Siding, Prevail® Lap Siding,
HardieShingle° smooth and textured (HZ5 and
HZ10), Artisan° Shingle, HardiePanel° Vertical
Siding smooth and textured (HZ5 and HZ10),
CemPanel® Vertical Siding, Prevail'" Panel
Siding, Artisan® Lap Siding, Artisan® V-Groove
Siding, Artisan® Bevel Channel, Artisan® Square
Channel, Artisan® Shiplap Lap Siding, Reveal®,
and Pressed Reveal® sidings.
FIBER -CEMENT EXTERIOR SIDING:
HardiePlank® smooth and textured Lap Siding
(HZ5 and HZ10), CemPlank® Lap Siding, Prevail°
Lap Siding, HardieShingle® smooth and
textured (HZ5 and HZ10), Artisan® Shingle,
HardiePanel° Vertical Siding smooth and
textured (HZ5 and HZ10), CemPanel® Vertical
Siding, Prevail— Panel Siding, Artisan® Lap
Siding, Artisan° V-Groove Siding, Artisan®
Bevel Channel, Artisan® Square Channel,
Artisan° Shiplap Lap Siding, Reveal®, or Pressed
Reveal® sidings installed in accordance with
manufacturer's installation instructions.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 12 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-01
Lntertek
Total Quality. Assured.
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
James Hardie Building Products
JH/FCS 60-01
James Hardie Fiber Cement Siding
ASTM E119, CAN/ULC 5101
Non -Symmetrical, 1 Hour Non -Load -Bearing Wall Assembly (Rating applies to both sides)
4
5
1. STEEL STUDS: Min. 3-5/8 in. depth 20 GA
(0.0359 in.) galvanized steel studs, spaced 24 in.
on center (oc) max.
2. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X
gypsum wallboard, oriented vertically and
fastened with 1-1/4 in. Type S drywall screws,
spaced 8 in. oc at board edges and 12 in. oc in
field areas of the board.
Date Revised: September 24, 2019 Page 1 of 2
Version: 02 August 2017
2A
3
GYPSUM SHEATHING, SIDE B: 1/2 in. Type X or
5/8 in. Type X gypsum sheathing, oriented
vertically with edge joints staggered from those
of Side A, fastened with 1-1/4 in. Type S drywall
screws spaced 24 in. oc.
3. ADDITIONAL LAYER(S) (Optional): Any one or
two of the following components can be used in
any order outward of the gypsum sheathing
(Item 2B):
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:1OPM I Uncontrolled Copy Page 13 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-01 (2 OF 2)
Lon
COMPONENT 1 — EXTERIOR INSULATION: The
exterior insulation may be installed up to the
max. thickness and density recognized in the
certification document.
ICC-ES AC377 certified open cell, spray -
applied polyurethane insulation
ASTM C578 certified extruded polystyrene
(XPS) insulation
ASTM C1289 certified polyiso insulation
Mineral wool batt insulation
COMPONENT 2 — WOOD STRUCTURAL PANEL
SHEATHING:
Code prescribed wood structural panel
sheathing
One layer of the wood structural panel
sheathing may also be installed interior of Item
3 B.
4. FURRING (Optional):
Min. 1-1/2 in. wide x 3/8 in. thick furring
(Wood: Min. 0.42 s.g.; Metal: Corrosion
Resistant min. 20 GA 33 ksi metal hat
channel, z-girt or u-bar), or
Date Revised: September 24, 2019
Version: 02 August 2017
Page 2 of 2
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
Min. 4.574 in. wide x 3/4 in. thick James
Hardie Horizontal Steel Furring installed per
manufacturer's installation instructions
(min. 18 GA 33 ksi metal)
S. CERTIFIED MANUFACTURER: James Hardie
Building Products Inc.
CERTIFIED PRODUCTS: HardiePlank® smooth
and textured Lap Siding (HZ5 and HZ10),
CemPlank° Lap Siding, Prevail® Lap Siding,
HardieShingle° smooth and textured (HZ5 and
HZ10), Artisan° Shingle, HardiePanel° Vertical
Siding smooth and textured (HZ5 and HZ10),
CemPanel® Vertical Siding, Prevail'" Panel
Siding, Artisan® Lap Siding, Artisan® V-Groove
Siding, Artisan® Bevel Channel, Artisan® Square
Channel, Artisan® Shiplap Lap Siding, Reveal®,
or Pressed Reveal® sidings installed in
accordance with manufacturer's installation
instructions.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 14 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-02
Lntertek
Total Quality. Assured.
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
James Hardie Building Products
JH/FCS 60-02
James Hardie Fiber Cement Siding
ASTM E119, CAN/ULC 5101
Non -Symmetrical, 1 Hour Load -Bearing Wall Assembly — Full Design Load
(Rating applies to both sides)
4
s _t
j. 3A
6 r
\ / 2
3B
1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn
wood studs located 16 in. on center (oc), with
two top plates and a single bottom plate.
2. CAVITY INSULATION (Optional): Glass fiber
batt insulation, conforming to CSA A101; Glass
fiber insulation min. 0.6 kg/m3.
3. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X
gypsum wallboard, oriented vertically and
fastened with 1-3/4 in. cup -head gypsum nails,
spaced 7 in. oc at board edges and in field
areas, or 1-1/2 in. Type S drywall screws,
Date Revised: September 24, 2019 Page 1 of 2
Version: 02 August 2017
spaced 8 in. oc at board edges and in field
areas of boards.
GYPSUM SHEATHING, SIDE B: 5/8 in. Type X
gypsum sheathing fastened with 1-3/4 in. long
roofing nails spaced 7 in. oc. Sheathing edge
joints shall be staggered from those on
opposite side of the wall.
4. ADDITIONAL LAYER(S) (Optional): Any one or
two of the following components can be used
in any order outward of the gypsum sheathing
(Item 3B):
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 15 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-02 (2 OF 2)
Lon
COMPONENT 1 — EXTERIOR INSULATION: The
exterior insulation may be installed up to the
max. thickness and density recognized in the
certification document.
ICC-ES AC377 certified open cell, spray -
applied polyurethane insulation
ASTM C578 certified extruded polystyrene
(XPS) insulation
ASTM C1289 certified polyiso insulation
Mineral wool batt insulation
COMPONENT 2 — WOOD STRUCTURAL PANEL
SHEATHING:
Code prescribed wood structural panel
sheathing
One layer of the wood structural panel
sheathing may also be installed on the interior
of Item 3B.
FURRING (Optional):
Min. 1-1/2 in. wide x 3/8 in. thick furring
(Wood: Min. 0.42 s.g.; Metal: Corrosion
Resistant min. 20 GA 33 ksi metal hat
channel, z-girt or u-bar), or
Min. 4.574 in. wide x 3/4 in. thick James
Hardie Horizontal Steel Furring installed per
manufacturer's installation instructions
(min. 18 GA 33 ksi metal)
Date Revised: September 24, 2019
Version: 02 August 2017
Page 2 of 2
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
6. CERTIFIED MANUFACTURER: James Hardie
Building Products Inc.
CERTIFIED PRODUCT: HardiePlank° smooth
and textured Lap Siding (HZ5 and HZ10),
CemPlank° Lap Siding, Prevail® Lap Siding,
HardieShingle° smooth and textured (HZ5 and
HZ10), Artisan® Shingle, HardiePanel° Vertical
Siding smooth and textured (HZ5 and HZ10),
CemPanel® Vertical Siding, Prevail— Panel
Siding, Artisan® Lap Siding, Artisan° V-Groove
Siding, Artisan° Bevel Channel, Artisan° Square
Channel, Artisan® Shiplap Lap Siding, Reveal®,
and Pressed Reveal® sidings.
FIBRE -CEMENT EXTERIOR SIDING:
HardiePlank® smooth and textured Lap Siding
(HZ5 and HZ10), CemPlank® Lap Siding, Prevail®
Lap Siding, HardieShingle® smooth and
textured (HZ5 and HZ10), Artisan® Shingle,
HardiePanel® Vertical Siding smooth and
textured (HZ5 and HZ10), CemPanel® Vertical
Siding, Prevail— Panel Siding, Artisan® Lap
Siding, Artisan® V-Groove Siding, Artisan®
Bevel Channel, Artisan® Square Channel,
Artisan® Shiplap Lap Siding, Reveal°, or Pressed
Reveal(' sidings installed in accordance with
manufacturer's installation instructions.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 16 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-03
Lntertek
Total Quality. Assured.
4
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
James Hardie Building Products
Design No. JH/FCS 60-03
James Hardie Fiber Cement Siding
Non -Symmetrical, Load -Bearing Wall Assembly — Full Design Load
ASTM E119, CAN/ULC 5101
Fire Resistance Rating —1 Hour (Rating applies to both sides)
1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn
wood studs located 24 in. on center (oc), with
two top plates and a single bottom plate.
2. CAVITY INSULATION (Required): Glass fiber
batt insulation, conforming to CSA A101; Glass
fiber insulation min. 0.6 kg/m3.
3. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X
gypsum wallboard, oriented vertically and
fastened with 1-3/4 in. cup -head gypsum nails,
spaced 7 in. oc at board edges and in field
areas, or 1-1/2 in. Type S drywall screws,
Date Revised: September 24, 2019 Page 1 of 2
Version: 02 August 2017
t
2
/ r 3A
313
spaced 8 in. oc at board edges and in field
areas of boards.
GYPSUM SHEATHING, SIDE B: 5/8 in. Type X
gypsum sheathing fastened with 1-3/4 in. long
roofing nails spaced 7 in. oc. Sheathing edge
joints shall be staggered from those on
opposite side of the wall.
4. ADDITIONAL LAYER(S) (Optional): Any one or
two of the following components can be used
in any order outward of the gypsum sheathing
(Item 3B):
Project No. G103235027
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 17 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-03 (2 OF 2)
Lon
COMPONENT 1 — EXTERIOR INSULATION: The
exterior insulation may be installed up to the
max. thickness and density recognized in the
certification document.
ICC-ES AC377 certified open cell, spray -
applied polyurethane insulation
ASTM C578 certified extruded polystyrene
(XPS) insulation
ASTM C1289 certified polyiso insulation
Mineral wool batt insulation
COMPONENT 2 — WOOD STRUCTURAL PANEL
SHEATHING:
Code prescribed wood structural panel
sheathing
One layer of the wood structural panel
sheathing may also be installed on the interior
of Item 3B.
FURRING (Optional):
Min. 1-1/2 in. wide x 3/8 in. thick furring
(Wood: Min. 0.42 s.g.; Metal: Corrosion
Resistant min. 20 GA 33 ksi metal hat
channel, z-girt or u-bar), or
Min. 4.574 in. wide x 3/4 in. thick James
Hardie Horizontal Steel Furring installed per
manufacturer's installation instructions
(min. 18 GA 33 ksi metal)
Date Revised: September 24, 2019
Version: 02 August 2017
Page 2 of 2
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
6. CERTIFIED MANUFACTURER: James Hardie
Building Products Inc.
CERTIFIED PRODUCT: HardiePlank° smooth
and textured Lap Siding (HZ5 and HZ10),
CemPlank° Lap Siding, Prevail® Lap Siding,
HardieShingle° smooth and textured (HZ5 and
HZ10), Artisan® Shingle, HardiePanel° Vertical
Siding smooth and textured (HZ5 and HZ10),
CemPanel® Vertical Siding, Prevail— Panel
Siding, Artisan® Lap Siding, Artisan° V-Groove
Siding, Artisan° Bevel Channel, Artisan° Square
Channel, Artisan® Shiplap Lap Siding, Reveal®,
and Pressed Reveal® sidings.
FIBRE -CEMENT EXTERIOR SIDING:
HardiePlank® smooth and textured Lap Siding
(HZ5 and HZ10), CemPlank® Lap Siding, Prevail®
Lap Siding, HardieShingle® smooth and
textured (HZ5 and HZ10), Artisan® Shingle,
HardiePanel® Vertical Siding smooth and
textured (HZ5 and HZ10), CemPanel® Vertical
Siding, Prevail— Panel Siding, Artisan® Lap
Siding, Artisan® V-Groove Siding, Artisan®
Bevel Channel, Artisan® Square Channel,
Artisan® Shiplap Lap Siding, Reveal°, or Pressed
Reveal(' sidings installed in accordance with
manufacturer's installation instructions.
Project No. G103235027
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 18 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-04
Lntertek
Total Quality. Assured.
4
6
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
James Hardie Building Products
JH/FCS 60-04
James Hardie Fiber Cement Siding
ASTM E119, CAN/ULC 5101
Non -Symmetrical, 1 Hour Load -Bearing Wall Assembly
Full Design Load per ASTM E119, 92% Design Load per CAN/ULC 5101
(Rating applies to both sides)
1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn
wood studs located 24 in. on center (oc), with
two top plates and a single bottom plate.
2. CAVITY INSULATION (Optional): R13 glass fiber
batt insulation.
Date Revised: September 24, 2019
Version: 02 August 2017
Page 1 of 2
/ 3A
313
3. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X
gypsum wallboard, oriented vertically and
fastened with 1-3/4 in. cup -head gypsum nails,
spaced 7 in. oc at board edges and in field
areas, or 1-1/2 in. Type S drywall screws,
spaced 8 in. oc at board edges and in field
areas of boards.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:1OPM I Uncontrolled Copy Page 19 of 20
Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM
JH/FCS 60-04 (2 OF 2)
Lon
GYPSUM SHEATHING, SIDE B: 1/2 in. Type X or
5/8 in. Type X gypsum sheathing fastened with
1-3/4 in. long roofing nails spaced 7 in. oc.
Sheathing edge joints shall be staggered from
those on opposite sides of the wall.
4. ADDITIONAL LAYER(S) (Optional): Any one or
two of the following components can be used
in any order outward of the gypsum sheathing
(Item 36):
COMPONENT 1 — EXTERIOR INSULATION: The
exterior insulation may be installed up to the
max. thickness and density recognized in the
certification document.
ICC-ES AC377 certified open cell, spray -
applied polyurethane insulation
ASTM C578 certified extruded polystyrene
(XPS) insulation
ASTM C1289 certified polyiso insulation
Mineral wool batt insulation
COMPONENT 2 — WOOD STRUCTURAL PANEL
SHEATHING:
Code prescribed wood structural panel
sheathing
One layer of the Wood Structural Panel
Sheathing may also be installed on the interior
of Item 3B.
S. FURRING (Optional):
Min. 1-1/2 in. wide x 3/8 in. thick furring
(Wood: Min. 0.42 s.g.; Metal: Corrosion
Resistant min. 20 GA 33 ksi metal hat
channel, z-girt or u-bar), or
Date Revised: September 24, 2019
Version: 02 August 2017
Page 2 of 2
Division 07 —Thermal and Moisture Protection
07 46 00 Siding
07 46 46 Fiber -Cement Siding
Min. 4.574 in. wide x 3/4 in. thick James
Hardie Horizontal Steel Furring installed per
manufacturer's installation instructions
(min. 18 GA 33 ksi metal)
6. CERTIFIED MANUFACTURER: James Hardie
Building Products Inc.
CERTIFIED PRODUCT: HardiePlank® smooth
and textured Lap Siding (HZ5 and HZ10),
CemPlank° Lap Siding, Prevail® Lap Siding,
HardieShingle° smooth and textured (HZ5 and
HZ10), Artisan° Shingle, HardiePanel° Vertical
Siding smooth and textured (HZ5 and HZ10),
CemPanel® Vertical Siding, Prevail'" Panel
Siding, Artisan® Lap Siding, Artisan® V-Groove
Siding, Artisan® Bevel Channel, Artisan® Square
Channel, Artisan® Shiplap Lap Siding, Reveal®,
and Pressed Reveal® sidings.
FIBRE CEMENT EXTERIOR SIDING:
HardiePlank® smooth and textured Lap Siding
(HZ5 and HZ10), CemPlank® Lap Siding, Prevail°
Lap Siding, HardieShingle® smooth and
textured (HZ5 and HZ10), Artisan® Shingle,
HardiePanel° Vertical Siding smooth and
textured (HZ5 and HZ10), CemPanel® Vertical
Siding, Prevail— Panel Siding, Artisan® Lap
Siding, Artisan° V-Groove Siding, Artisan®
Bevel Channel, Artisan® Square Channel,
Artisan° Shiplap Lap Siding, Reveal®, or Pressed
Reveal® sidings installed in accordance with
manufacturer's installation instructions.
Project No. G103972785
James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 20 of 20