Loading...
HomeMy WebLinkAboutFL19901_R4_C_CAC_Intertek Listing Reveal PanelReport prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM ntertek Total Quality. Assured. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing ReporL(s). This authorization also applies to the Multiple Listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The Certification Mark(s) may be applied only at the location of the Party Authorized to Apply Mark. Applicant: James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 United States Contact: Benjamin Batres Phone: 909-841-4109 Fax: 909-427-0634 Email: benjamin.batres@jhresearchusa.com Party Authorized to Apply Mark: See following page(s) Evaluation Center: Intertek (Coquitlam) Client Number: 205963 Authorized By: Jean -Philippe Kayl, airectorofCertificabon Intertek Testing Services NA, Inc_ 545 E. Algonquin Road, Ste H., Arlington Heights, IL 60005 USA Phone: 947-43MC36T Fax: 547-439-7320 COTTus Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Testing Standard(s): CAN / ULC S101 (2007), CAN / ULC S114 (2005), CAN / ULC S102 (2010), AAMA 509 (2009), ASTM E136 (2012), CAN / ULC S101 (2014), ASTM E84 (2016), ASTM E136 (2016) Ed. 16a, ASTM E119 (2016), ISO 8336:2017 Ed.3, ASTM E84 (2015), ASTM E119 (2015), ASTM E330 (2014), ASTM C1186-08 (2012), ISO 8336 (2009), EN 12467:2012 +A1 Product: James Hardie 7/16" Panel Siding James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 1 of 20 ATM for Report: G 101575558; G 102753016; G 100461561; ATM Issue Date: 1 /19/2021 G100844583; G101505709;G101414684; G10247028;G102477668; G102573914; G3180889; Building Products, Inc.) on 1/19/2021 1:38:38 PM G103112417, G102753016, G103942655, G103470658,G104368432 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 2 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM Listing Section(s): WALL ASSEMBLIES CSI Code(s): 07 46 00 Siding Description: James Hardie Reveal® and Pressed Reveal® are fiber cement panel sidings. Product IDimensions Weight Width: 48 in. Reveal® Length: 96 in. 3.1 Ibs/ft (Thickness: 7/16 in. Width: 48 in. Pressed Reveal® Length: 96 in. 4.3 Ibs/ft Thickness: 7/16 in. PHYSICAL RATINGS Product Standard Rating Reveal® and Pressed Reveal® Panel Sidings STM C1186 Meets Grade II, Type A BS EN 12467 Meets Category A, Class 2, Level I ISO 8336 Meets Category A, Class 2, Level I FIRE RATINGS Product Standard Rating IDesign Listing Number Reveal® and Pressed Reveal® Panel Sidings ASTM E136 Non-combustible IN/A CAN/ULC S114 Non-combustible N/A ASTM E84 Flame Spread Index: 0 Smoke Developed Index: 0 N/A CAN/ULC S102 Flame Spread Index: 0 Smoke Developed Index: 5 N/A ASTM E119 CAN/ULC S101 1 Hour JH/FCS 60-01 JH/FCS 60-02 JH/FCS 60-03 JH/FCS 60-04 2 Hours JH/FCS 120-01 JH/FCS 120-02 STRUCTURAL RATINGS Structural rating for Reveal® and Pressed Reveal® Panel Sidings per ASTM E330: m No James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 3 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM Results: Ultimate Load: 127.4 psf Details: • Framing: 20 GA Steel (nominal 2x4) • Stud spacing: 16 in. on center • Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter • Fastener spacing: 3 fasteners at 16" o.c System No. #2 Results: Ultimate Load: 99.5 psf Details: • Framing: 20 GA Steel (nominal 2x4) • Stud spacing: 24 in. on center • Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter • Fastener spacing: 3 fasteners at 16" o.c System No. #3 Results: Ultimate Load: 128.5 psf Details: • Framing: 20 GA Steel (nominal 2x4) • Stud spacing: 16 in. on center • Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter • Fastener spacing: 4 fasteners at 12" o.c System No. #4 Results: Ultimate Load: 111.3 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: Treated % in. x 4 in. • Stud spacing: 16 in. on center • Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter • Fastener spacing: 3 fasteners at 16" o.c System No. #5 Results: Ultimate Load: 110.1 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: Treated % in. x 4 in. • Stud spacing: 24 in. on center • Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter • Fastener spacing: 3 fasteners at 16" o.c System No. #6 Results: Ultimate Load: 134.4 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 4 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM • Furring: Treated 1/4 in. x 4 in. • Stud spacing: 16 in. on center • Fastener Type: #8 x 1-5/8 in. long buglehead self -tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter • Fastener spacing: 4 fasteners at 12" o.c System No. #7 Results: Ultimate Load: 150 psf Details: • Framing: 20 GA Steel (nominal 2x4) • Stud spacing: 24 in. on center • Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter, 0.132 in. shank diameter • Fastener spacing: 4 fasteners at 12" o.c System No. #8 Results: Ultimate Load: 168.9 psf Details: • Framing: 20 GA Steel (nominal 2x4) • Stud spacing: 16 in. on center • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw • Fastener spacing: 3 fasteners at 16" o.c System No. #9 Results: Ultimate Load: 207.6 psf Details: • Framing: 20 GA Steel (nominal 2x4) • Stud spacing: 16 in. on center • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw • Fastener spacing: 4 fasteners at 12" o.c System No. #10 Results: Ultimate Load: 172.2 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: treated 1/4 in. x 4 in. • Stud spacing: 24 in. on center • Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter, 0.132 in. shank diameter • Fastener spacing: 4 fasteners at 12" o.c System No. #11 Results: Ultimate Load: 127.6 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood • Stud spacing: 16 in. on center • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw • Fastener spacing: 3 fasteners at 16" o.c James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 5 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM System No. #12 Results: Ultimate Load: 206.2 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood • Stud spacing: 16 in. on center • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw • Fastener spacing: 4 fasteners at 12" o.c System No. #13 Results: Ultimate Load: 137.1 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood • Stud spacing: 16 in. on center • Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38) • Fastener spacing: 2 fasteners at 24" o.c System No. #14 Results: Ultimate Load: 137.1 psf Details: • Framing: Wood nominal 2x4 SPF #2+BTR • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood • Stud spacing: 16 in. on center • Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38) • Fastener spacing: 2 fasteners at 24" o.c Reveal® and Pressed Reveal® Sidings comply with the requirements of AAMA 509 when tested with the following installation details: System No. 1 Results: Meets the requirements of AAMA 509 Details: • Framing: SPF wood framing, nominal 2 in. x 6 in. • Furring: 3/4 in. thick x 4 in. wide pressure treated plywood • Weather Barrier: One layer of Tyvek ® HomeWrap ® installed over framing, stapled at 24 in. on center • Fastener Type: Countersunk #8 x 1-5/8 in. long buglehead screws • Fastener Spacing: 16 in. at o.c FLORIDA PRODUCT INFORMATION Product Evaluated FL No. James Hardie Reveal® and Pressed Reveal® Sidings 19901 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 6 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM Party(s) Authorized by Manufacturer To Apply Mark: James Hardie Building Products, Inc. (Peru, IL) 17 Unytite Drive Peru, IL 61354 United States Contact: Doc Walker Phone: 815-343-5605 Fax: 815-220-3087 Email: Doc.Walker@jameshardie.com Party(s) Authorized by Other Parties To Apply Mark: None James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 7 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM DRAWING INDEX JH/FCS 120-01 JH/FCS 120-02 JH/FCS 60-01 JH/FCS 60-02 JH/FCS 60-03 JH/FCS 60-04 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 8 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 120-01 Lntertek Total Quality. Assured. 4 6 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding James Hardie Building Products Design No.1H/FCS 120-01 James Hardie Fiber Cement Siding Non -Symmetrical, Non -Load -Bearing Wall Assembly ASTM E119, CAN/ULC 5101 Fire Resistance Rating — 2 Hour (Rating applies to both sides) 1. STEEL STUDS: Min. 3-5/8 in. depth 20 GA (0.0359 in.) galvanized steel studs, spaced 16 in. on center (oc) max. 2. CAVITY INSULATION (Required): Stud cavities filled with R12 un-faced fiberglass insulation. 3. GYPSUM WALLBOARD, SIDE A: Two layers of 5/8 in. Type X gypsum board or 5/8 in. Densglass Gold board, oriented horizontally, and fastened to the steel studs using 1-5/8 in. DW screws every 8 in. oc for the first layer and Date Revised: September 24, 2019 Page 1 of 2 Version: 02 August 2017 3A 2 1 313 2-1/4 in. DW screws every 8 in. oc for the second layer. All joints and screws covered with joint compound. GYPSUM WALLBOARD, SIDE B: Two layers of 5/8 in. Type X gypsum board or 5/8 in. Densglass Gold board, oriented horizontally, and fastened to the steel studs using 1-5/8 in. DW screws every 8 in. oc for the first layer and 2-1/4 in. DW screws every 8 in. oc for the second layer. All joints and screws covered with joint compound. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 9 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 120-01 (2 OF 2) Lon 4. WOOD SHEATHING (Optional): ADDITIONAL LAYER(S) (Optional): Any one or two of the following components can be used in any order outward of the gypsum sheathing (Item 313): COMPONENT 1 — EXTERIOR INSULATION: The exterior insulation may be installed up to the max. thickness and density recognized in the certification document. ICC-ES AC377 certified open cell, spray - applied polyurethane insulation ASTM C578 certified extruded polystyrene (XPS) insulation ASTM C1289 certified polyiso insulation Mineral wool batt insulation COMPONENT 2 — WOOD STRUCTURAL PANEL SHEATHING: Code prescribed wood structural panel sheathing One layer of the wood structural panel sheathing may also be installed on the interior of Item 3B. FURRING (Optional): Min. 1-1/2 in. wide x 3/8 in. thick furring (Wood: Min. 0.42 SG; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar), or Date Revised: September 24, 2019 Version: 02 August 2017 Page 2 of 2 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding Min. 4.574 in. wide x 3/4 in. thick James Hardie Horizontal Steel Furring installed per manufacturer's installation instructions (min. 18 GA 33 ksi metal) 6. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCT: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank° Lap Siding, Prevail® Lap Siding, HardieShingle° smooth and textured (HZ5 and HZ10), Artisan° Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail'" Panel Siding, Artisan® Lap Siding, Artisan® V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan® Shiplap Lap Siding, Reveal®, and Pressed Reveal® sidings. FIBER -CEMENT EXTERIOR SIDING: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank® Lap Siding, Prevail° Lap Siding, HardieShingle® smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan° V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan° Shiplap Lap Siding, Reveal®, or Pressed Reveal® sidings installed in accordance with manufacturer's installation instructions. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 10 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 120-02 Lntertek Total Quality. Assured. 4 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding James Hardie Building Products Design No.1H/FCS 120-02 James Hardie Fiber Cement Siding Non -Symmetrical, Load -Bearing Wall Assembly — Full Design Load ASTM E119, CAN/ULC 5101 Fire Resistance Rating — 2 Hour (Rating applies to both sides) 6 1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn wood studs located 16 in. on center (oc), with top and bottom plates using 3 in. framing nails. 2. INSULATION (Required): Stud cavities filled with R12 un-faced fiberglass insulation. 3. GYPSUM WALLBOARD: Two layers of 5/8 in. Type X gypsum board or 5/8 in. Densglass Gold board, oriented horizontally, and fastened to the steel studs using 1-5/8 in. DW screws every 8 in. oc for the first layer and 2-1/4 in. DW Date Revised: September 24, 2019 Page 1 of 2 Version: 02 August 2017 3A r 1 I 36 5 screws every 8 in. oc for the second layer. All joints and screws covered with joint compound. GYPSUM WALLBOARD, SIDE B: Two layers of 5/8 in. Type X gypsum board or 5/8 in. Densglass Gold board, oriented horizontally, and fastened to the steel studs using 1-5/8 in. DW screws every 8 in. oc for the first layer and 2-1/4 in. DW screws every 8 in. oc for the second layer. All joints and screws covered with joint compound. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 11 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 120-02 (2 OF 2) Lon 4. WOOD SHEATHING (Optional): ADDITIONAL LAYER(S) (Optional): Any one or two of the following components can be used in any order outward of the gypsum sheathing (Item 313): COMPONENT 1 — EXTERIOR INSULATION: The exterior insulation may be installed up to the max. thickness and density recognized in the certification document. ICC-ES AC377 certified open cell, spray - applied polyurethane insulation ASTM C578 certified extruded polystyrene (XPS) insulation ASTM C1289 certified polyiso insulation Mineral wool batt insulation COMPONENT 2 — WOOD STRUCTURAL PANEL SHEATHING: Code prescribed wood structural panel sheathing One layer of the wood structural panel sheathing may also be installed on the interior of Item 3B. FURRING (Optional): Min. 1-1/2 in. wide x 3/8 in. thick furring (Wood: Min. 0.42SG; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar), or Date Revised: September 24, 2019 Version: 02 August 2017 Page 2 of 2 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding Min. 4.574 in. wide x 3/4 in. thick James Hardie Horizontal Steel Furring installed per manufacturer's installation instructions (min. 18 GA 33 ksi metal) 6. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCT: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank° Lap Siding, Prevail® Lap Siding, HardieShingle° smooth and textured (HZ5 and HZ10), Artisan° Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail'" Panel Siding, Artisan® Lap Siding, Artisan® V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan® Shiplap Lap Siding, Reveal®, and Pressed Reveal® sidings. FIBER -CEMENT EXTERIOR SIDING: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank® Lap Siding, Prevail° Lap Siding, HardieShingle® smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan° V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan° Shiplap Lap Siding, Reveal®, or Pressed Reveal® sidings installed in accordance with manufacturer's installation instructions. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 12 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-01 Lntertek Total Quality. Assured. Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding James Hardie Building Products JH/FCS 60-01 James Hardie Fiber Cement Siding ASTM E119, CAN/ULC 5101 Non -Symmetrical, 1 Hour Non -Load -Bearing Wall Assembly (Rating applies to both sides) 4 5 1. STEEL STUDS: Min. 3-5/8 in. depth 20 GA (0.0359 in.) galvanized steel studs, spaced 24 in. on center (oc) max. 2. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X gypsum wallboard, oriented vertically and fastened with 1-1/4 in. Type S drywall screws, spaced 8 in. oc at board edges and 12 in. oc in field areas of the board. Date Revised: September 24, 2019 Page 1 of 2 Version: 02 August 2017 2A 3 GYPSUM SHEATHING, SIDE B: 1/2 in. Type X or 5/8 in. Type X gypsum sheathing, oriented vertically with edge joints staggered from those of Side A, fastened with 1-1/4 in. Type S drywall screws spaced 24 in. oc. 3. ADDITIONAL LAYER(S) (Optional): Any one or two of the following components can be used in any order outward of the gypsum sheathing (Item 2B): Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:1OPM I Uncontrolled Copy Page 13 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-01 (2 OF 2) Lon COMPONENT 1 — EXTERIOR INSULATION: The exterior insulation may be installed up to the max. thickness and density recognized in the certification document. ICC-ES AC377 certified open cell, spray - applied polyurethane insulation ASTM C578 certified extruded polystyrene (XPS) insulation ASTM C1289 certified polyiso insulation Mineral wool batt insulation COMPONENT 2 — WOOD STRUCTURAL PANEL SHEATHING: Code prescribed wood structural panel sheathing One layer of the wood structural panel sheathing may also be installed interior of Item 3 B. 4. FURRING (Optional): Min. 1-1/2 in. wide x 3/8 in. thick furring (Wood: Min. 0.42 s.g.; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar), or Date Revised: September 24, 2019 Version: 02 August 2017 Page 2 of 2 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding Min. 4.574 in. wide x 3/4 in. thick James Hardie Horizontal Steel Furring installed per manufacturer's installation instructions (min. 18 GA 33 ksi metal) S. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCTS: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank° Lap Siding, Prevail® Lap Siding, HardieShingle° smooth and textured (HZ5 and HZ10), Artisan° Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail'" Panel Siding, Artisan® Lap Siding, Artisan® V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan® Shiplap Lap Siding, Reveal®, or Pressed Reveal® sidings installed in accordance with manufacturer's installation instructions. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 14 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-02 Lntertek Total Quality. Assured. Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding James Hardie Building Products JH/FCS 60-02 James Hardie Fiber Cement Siding ASTM E119, CAN/ULC 5101 Non -Symmetrical, 1 Hour Load -Bearing Wall Assembly — Full Design Load (Rating applies to both sides) 4 s _t j. 3A 6 r \ / 2 3B 1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn wood studs located 16 in. on center (oc), with two top plates and a single bottom plate. 2. CAVITY INSULATION (Optional): Glass fiber batt insulation, conforming to CSA A101; Glass fiber insulation min. 0.6 kg/m3. 3. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X gypsum wallboard, oriented vertically and fastened with 1-3/4 in. cup -head gypsum nails, spaced 7 in. oc at board edges and in field areas, or 1-1/2 in. Type S drywall screws, Date Revised: September 24, 2019 Page 1 of 2 Version: 02 August 2017 spaced 8 in. oc at board edges and in field areas of boards. GYPSUM SHEATHING, SIDE B: 5/8 in. Type X gypsum sheathing fastened with 1-3/4 in. long roofing nails spaced 7 in. oc. Sheathing edge joints shall be staggered from those on opposite side of the wall. 4. ADDITIONAL LAYER(S) (Optional): Any one or two of the following components can be used in any order outward of the gypsum sheathing (Item 3B): Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 15 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-02 (2 OF 2) Lon COMPONENT 1 — EXTERIOR INSULATION: The exterior insulation may be installed up to the max. thickness and density recognized in the certification document. ICC-ES AC377 certified open cell, spray - applied polyurethane insulation ASTM C578 certified extruded polystyrene (XPS) insulation ASTM C1289 certified polyiso insulation Mineral wool batt insulation COMPONENT 2 — WOOD STRUCTURAL PANEL SHEATHING: Code prescribed wood structural panel sheathing One layer of the wood structural panel sheathing may also be installed on the interior of Item 3B. FURRING (Optional): Min. 1-1/2 in. wide x 3/8 in. thick furring (Wood: Min. 0.42 s.g.; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar), or Min. 4.574 in. wide x 3/4 in. thick James Hardie Horizontal Steel Furring installed per manufacturer's installation instructions (min. 18 GA 33 ksi metal) Date Revised: September 24, 2019 Version: 02 August 2017 Page 2 of 2 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding 6. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCT: HardiePlank° smooth and textured Lap Siding (HZ5 and HZ10), CemPlank° Lap Siding, Prevail® Lap Siding, HardieShingle° smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan° V-Groove Siding, Artisan° Bevel Channel, Artisan° Square Channel, Artisan® Shiplap Lap Siding, Reveal®, and Pressed Reveal® sidings. FIBRE -CEMENT EXTERIOR SIDING: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank® Lap Siding, Prevail® Lap Siding, HardieShingle® smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel® Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan® V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan® Shiplap Lap Siding, Reveal°, or Pressed Reveal(' sidings installed in accordance with manufacturer's installation instructions. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 16 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-03 Lntertek Total Quality. Assured. 4 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding James Hardie Building Products Design No. JH/FCS 60-03 James Hardie Fiber Cement Siding Non -Symmetrical, Load -Bearing Wall Assembly — Full Design Load ASTM E119, CAN/ULC 5101 Fire Resistance Rating —1 Hour (Rating applies to both sides) 1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn wood studs located 24 in. on center (oc), with two top plates and a single bottom plate. 2. CAVITY INSULATION (Required): Glass fiber batt insulation, conforming to CSA A101; Glass fiber insulation min. 0.6 kg/m3. 3. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X gypsum wallboard, oriented vertically and fastened with 1-3/4 in. cup -head gypsum nails, spaced 7 in. oc at board edges and in field areas, or 1-1/2 in. Type S drywall screws, Date Revised: September 24, 2019 Page 1 of 2 Version: 02 August 2017 t 2 / r 3A 313 spaced 8 in. oc at board edges and in field areas of boards. GYPSUM SHEATHING, SIDE B: 5/8 in. Type X gypsum sheathing fastened with 1-3/4 in. long roofing nails spaced 7 in. oc. Sheathing edge joints shall be staggered from those on opposite side of the wall. 4. ADDITIONAL LAYER(S) (Optional): Any one or two of the following components can be used in any order outward of the gypsum sheathing (Item 3B): Project No. G103235027 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 17 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-03 (2 OF 2) Lon COMPONENT 1 — EXTERIOR INSULATION: The exterior insulation may be installed up to the max. thickness and density recognized in the certification document. ICC-ES AC377 certified open cell, spray - applied polyurethane insulation ASTM C578 certified extruded polystyrene (XPS) insulation ASTM C1289 certified polyiso insulation Mineral wool batt insulation COMPONENT 2 — WOOD STRUCTURAL PANEL SHEATHING: Code prescribed wood structural panel sheathing One layer of the wood structural panel sheathing may also be installed on the interior of Item 3B. FURRING (Optional): Min. 1-1/2 in. wide x 3/8 in. thick furring (Wood: Min. 0.42 s.g.; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar), or Min. 4.574 in. wide x 3/4 in. thick James Hardie Horizontal Steel Furring installed per manufacturer's installation instructions (min. 18 GA 33 ksi metal) Date Revised: September 24, 2019 Version: 02 August 2017 Page 2 of 2 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding 6. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCT: HardiePlank° smooth and textured Lap Siding (HZ5 and HZ10), CemPlank° Lap Siding, Prevail® Lap Siding, HardieShingle° smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan° V-Groove Siding, Artisan° Bevel Channel, Artisan° Square Channel, Artisan® Shiplap Lap Siding, Reveal®, and Pressed Reveal® sidings. FIBRE -CEMENT EXTERIOR SIDING: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank® Lap Siding, Prevail® Lap Siding, HardieShingle® smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel® Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan® V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan® Shiplap Lap Siding, Reveal°, or Pressed Reveal(' sidings installed in accordance with manufacturer's installation instructions. Project No. G103235027 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 18 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-04 Lntertek Total Quality. Assured. 4 6 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding James Hardie Building Products JH/FCS 60-04 James Hardie Fiber Cement Siding ASTM E119, CAN/ULC 5101 Non -Symmetrical, 1 Hour Load -Bearing Wall Assembly Full Design Load per ASTM E119, 92% Design Load per CAN/ULC 5101 (Rating applies to both sides) 1. WOOD STUDS: Nominal 2 in. x 4 in. solid sawn wood studs located 24 in. on center (oc), with two top plates and a single bottom plate. 2. CAVITY INSULATION (Optional): R13 glass fiber batt insulation. Date Revised: September 24, 2019 Version: 02 August 2017 Page 1 of 2 / 3A 313 3. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X gypsum wallboard, oriented vertically and fastened with 1-3/4 in. cup -head gypsum nails, spaced 7 in. oc at board edges and in field areas, or 1-1/2 in. Type S drywall screws, spaced 8 in. oc at board edges and in field areas of boards. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:1OPM I Uncontrolled Copy Page 19 of 20 Report prepared for Jose Gonzalez (James Hardie Building Products, Inc.) on 1/19/2021 1:38:38 PM JH/FCS 60-04 (2 OF 2) Lon GYPSUM SHEATHING, SIDE B: 1/2 in. Type X or 5/8 in. Type X gypsum sheathing fastened with 1-3/4 in. long roofing nails spaced 7 in. oc. Sheathing edge joints shall be staggered from those on opposite sides of the wall. 4. ADDITIONAL LAYER(S) (Optional): Any one or two of the following components can be used in any order outward of the gypsum sheathing (Item 36): COMPONENT 1 — EXTERIOR INSULATION: The exterior insulation may be installed up to the max. thickness and density recognized in the certification document. ICC-ES AC377 certified open cell, spray - applied polyurethane insulation ASTM C578 certified extruded polystyrene (XPS) insulation ASTM C1289 certified polyiso insulation Mineral wool batt insulation COMPONENT 2 — WOOD STRUCTURAL PANEL SHEATHING: Code prescribed wood structural panel sheathing One layer of the Wood Structural Panel Sheathing may also be installed on the interior of Item 3B. S. FURRING (Optional): Min. 1-1/2 in. wide x 3/8 in. thick furring (Wood: Min. 0.42 s.g.; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar), or Date Revised: September 24, 2019 Version: 02 August 2017 Page 2 of 2 Division 07 —Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber -Cement Siding Min. 4.574 in. wide x 3/4 in. thick James Hardie Horizontal Steel Furring installed per manufacturer's installation instructions (min. 18 GA 33 ksi metal) 6. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCT: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank° Lap Siding, Prevail® Lap Siding, HardieShingle° smooth and textured (HZ5 and HZ10), Artisan° Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail'" Panel Siding, Artisan® Lap Siding, Artisan® V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan® Shiplap Lap Siding, Reveal®, and Pressed Reveal® sidings. FIBRE CEMENT EXTERIOR SIDING: HardiePlank® smooth and textured Lap Siding (HZ5 and HZ10), CemPlank® Lap Siding, Prevail° Lap Siding, HardieShingle® smooth and textured (HZ5 and HZ10), Artisan® Shingle, HardiePanel° Vertical Siding smooth and textured (HZ5 and HZ10), CemPanel® Vertical Siding, Prevail— Panel Siding, Artisan® Lap Siding, Artisan° V-Groove Siding, Artisan® Bevel Channel, Artisan® Square Channel, Artisan° Shiplap Lap Siding, Reveal®, or Pressed Reveal® sidings installed in accordance with manufacturer's installation instructions. Project No. G103972785 James Hardie Building Products, Inc. 139761 1 Rev: Jan 19 2021 1:10PM I Uncontrolled Copy Page 20 of 20