Loading...
HomeMy WebLinkAboutFL13192_R6_II_2001-14.3 NOA_ Hardie Plank-Panel-SoffitSAE � Construction Applied Engineering Rathisha Sabaratnam, Sr. R&D Technical Services Specialist James Hardie Building Products, Inc. 10901 Elm Ave. Fontana, CA 92337 Subject: NOA 20-0730.06 for Compliance with 2020 Florida Building Code (7th Edition) Dear Rathisha, 8385 White Oak Ave. Rancho Cucamonga, CA 91730 Phone: 626.409.8650 Project No.: 2001-14.3 Date: December 14, 2020 At your request in reference to the Miami Dade Checklist requirements, based on my review of applicable sections of the 2020 Florida Building Code and the submitted test reports, it is my professional opinion that the siding products listed in the attached NOA meet the requirements of the 2020 Florida Building Code. At your request, based on my review of applicable sections of the 2020 Florida Building Code and the submitted test reports for the subject products listed in the above referenced NOA, it is my professional opinion that the siding products listed in the NOA meet the requirements of the 2020 Florida Building Code. Attached are the updated stamped product installation drawings. The following are referenced standards in the 2020 FBC: (1) Wood: AWC NDS-2018 & SDPWS-2015 (2) Structural Design: ASCE 7-16 (3) Concrete: ACI 318-14 (4) Masonry: TMS 402-2016 (5) Structural Steel: AISC 360-16 and 2017 AISC Steel Construction Manual (6) Cold -formed Steel: AISI 100-16 (7) Aluminum: AA ADM 1-2015 In addition, I make the following Statement of Independence: (a) I, V. Andrew Tan, do not have nor intend to acquire or will acquire any financial interest in any company manufacturing or distributing products for which evaluations are issued. (b) CAE is not owned, operated or controlled by any company manufacturing or distributing products we evaluate or inspect. (c) CAE does not have, nor will it acquire financial interest in any company manufacturing or distributing products for which reports are being issued. (d) CAE does not have, or will it acquire a financial interest in any other entity involved in the approval process of the product. Please feel free to contact me thank you again for your business. JE IV Respectfully submitted, -Z� F '. CAE, Inc. e' No. 81662 e 0e`, STATE OF ,' A// \ '01YA 1 E1,�,\� V. A w an, E., exp. 2/28/21 Principal Engineer Attachments: (1) NOA 20-0730.06 MIAMI. ADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.uoy/economy James Hardie Building Product, Inc. 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020, bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami - Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-0821.21 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 20-0730.06 49t�� Expiration Date: May 1, 2022 Approval Date: November 12, 2020 Page 1 James Hardie Building Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs A. DRAWINGS "Submitted under NOA # 13-0311.07" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E. B. TESTS "Submitted under NOA # 13-0311.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. "Submitted under NOA # 02-0729.02" Laboratory Report Test Date Signature 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E. 4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA # 15-0122.04" 1. Statement letter of code conformance to the 5th edition (2014) FBC issued by Ronald I. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I. Ogawa, P.E. 4611 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 20-0730.06 Expiration Date: May 1, 2022 Approval Date: November 12, 2020 E - 1 James Hardie Building Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 7th Edition (2020) of the FBC and of no financial interest issued by Construction Applied Engineering, dated 07/22/2020, signed and sealed by V. Andrew Tan, P.E. "Submitted under NOA # 17-0821.21" 2. Statement letter of code conformance to the 6th Edition (2017) FBC and of no financial interest issued by Ronald I. Ogawa & Associates, Inc., dated 07/30/2017, signed and sealed by Ronald I. Ogawa, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 20-0730.06 Expiration Date: May 1, 2022 Approval Date: November 12, 2020 E-2 WALL HEIGHT DETAIL A Jam' r t r II I —WALL LENGTH Stud Spacing at 16" O.C. B*-- I I I JA "j y 5 ATE O L14 Z 0 RN N Al - Nails at 16" O.C. (typ.) 3/8" Minimum Edge Distance Sheathing fastener, as described in Note 1 \ _ Panel fastener, as described in f ` Note 2 1� HardiePanel, Cempanel, Prevail Panel Siding I Water -resistive barrier per Florida Building Code Section 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 2322.3 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. SEE DETAIL A 5/8" thick / 5 ply APA rated plywood sheathing in accordance with Florida Building Code Section 2322.3 PRODUCT DESCRIPTION HardiePanel®, Cempanel®, & Prevail® Panel Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building Code. PANEL DIMENSIONS Water -resistive Width Length Thickness barrier per Florida 4' 8,9,10' 5/16" Building Code GI. Section 1404.2 DESIGN PRESSURE RATING 2" X 4" S-P-F Installation Design Pressure Wood Studs Wood Studs -76 psf HardiePanel, Impact Resistant — SECTION B-B Cempanel, Planks installed over 5/8" thick / 5 ply Prevail Panel APA rated plywood sheathing Siding HARDIEPANEL, CEMPANEL. PREVAIL PANEL SIDING INSTALLATION DETAILS All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. Wood studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to the studs in accordance with Florida Building Code Section 2322.3. • The siding panels shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum of 2"X4" S-P-F wood studs spaced a maximum of 16" O.C. [Note 2] The siding panel fastener shall be a 2• long, 0.223" head diameter, 0.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven through the 5/8" thick / 5 ply APA rated plywood sheathing into wood studs located at 16" O.C. • Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners. HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901,Elm Avenue Fontana, CA 92337 P7ne:909-356-6300 SIZE FSCM NO DWG NO REV 9-427-0634TM A PNL-PLK-SOFF 2 Creator: E. Gonzales SCALE 1/2" = 1'-0" Date: 9/29/2020 1 SHEET 1 OF 12 Fastener Spacing per Florida Building Code Section 2322.3 • • 6.00in. Cladding Framing Sheathing FRAMING • NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD HARDIEPANEL, CEMPANEL, PREVAIL PANEL SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA INSTALLATION DETAILS WOOD STUD CONSTRUCTION BUILDNG CODE SECTION 2322.3 CLADDING ■ THE PANEL IS FASTENED WITH 2" LONG, 0.223" HEAD James Hardie Building Products, Inc. DIAMETER, 0.092" SHANK DIAMETER, CORROSION 10901 Elm Avenue RESISTANT SIDING NAILS, PLACE NAILS 6" O.C. AT � � Fontana, CA 92337 PANEL EDGES AND INTERMEDIATE STUDS !Phone: 909-356-6300 size FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator: E. Gonzales SCALE 1" = 1"-Q" Date: 9/29/2020 SHEET 2 OF 12 WALL LENGTH Stud Spacing at 16" O.C. B No. 81662: * =! WALL HEIGHT•' I ; STATE O , �f OR1C�,� , - -L- - - - -t t — 3/8" Minimum Edge Distance Nails at 6" O.C. (typ.) DETAIL A Sheathing fastener, as described in Note 1 Panel fastener, as described in Note 2 rI � 1 i HardiePanel® Siding Water -resistive barrier per Florida Building Code Section 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened to metal studs as described in Note 1. 20ga, 3-5/8" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. SEE DETAIL A 5/8" thick / 5 ply APA rated . plywood sheathing fastened 4-F to metal studs as described in Note 1 Water -resistive barrier per Florida Building Code Section 1404.2 20ga, 3-5/8" X 1-5/8" Metal C-stud PRODUCT DESCRIPTION HardiePanel®, Cempanel®, & Prevail0 Panel Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building Code. PANEL DIMENSIONS Width Length Thickness 4' 8,9,10' 5/16" DESIGN PRESSURE RATING Installation Design Pressure Metal Studs -104 psf L11 HardiePanel, Impact Resistant — SECTION B-B Cempanel, Panel installed over 5/8" thick / 5 ply Prevail Panel APA rated plywood sheathing Siding HARDIEPANEL, CEMPANEL, PREVAIL PANEL SIDING INSTALLATION DETAILS • All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel edges and all intermediate supports using a No.8-18, 0.315" head diameter x 1-1/4" long bugle head screw • The siding panels shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C. [Note 2] The siding panel fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-5/8" long" ribbed bugle head screw ("or screw shall have at least 3 full threads penetrating metal framing); the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven through the 5/8" thick / 5 ply APA rated plywood sheathing into metal studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners. HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator: E. Gonzales SCALE 112" = 1'4' Date: 9/29/2020 1 SHEET 3 OF 12 • • T t! 6.00in. �76.00in.- 6.00in. • r / Cladding r j ,� ming Sheathing • E W -- T � 1•.N.,4� i bo r _ 1 ' F • • • • • • . • • • • r •• 0 A MING FRANOMINAL ��i 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C. lil� \\\\ .�� FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP IT AND BOTTOM CONNECTION) ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL, CEMPANEL, PREVAIL PANEL NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE INSTALLATION DETAILS METAL STUD CONSTRUCTION (& HEAD SCREW CLADDING ■ THE PANEL IS FASTENED WITH NO. 8-18, 0.315" HEAD James Hardie Building Products, Inc. DIAMETER X 1-5/8 " LONG CORROSION RESISTANT 10901 Elm Avenue RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT Fontana, CA 92337 LEAST 3 FULL THREADS PENETRATING THE METAL Phone: 909-356-6300 SIZE FSCM NO _ DWG NO REV FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES Fax 909-427-0634 A PNL-PLK-SOFF 2 AND INTERMEDIATE STUDS Creator: E. Gonzales SCALE 11, = 1'-0" Date: 9/29/2020 SHEET 4 OF 12 Stud Spacing at 16" O.C. WALL LENGTH - -� SEE I [ ---------------------- -- I • -- ------- ------------ � _ - - - - I : - -- --- ---;� - oMfif \\ MALL _ I i II : HT EIG14 or • [ I [ I I , _1___..___ �I [ • , [ [ :1 e rr } ilk : is-i it I ; fin B [--- 1 3/4" Minimum Edge Distance Nails at 16" O.C. (typ.) DETAIL A Sheathing fastener, as described in Note 1 _ Siding fastener, as described in Note 2 1, HardiePlank, Cemplank, Prevail Lap Siding / Water -resistive barrier �}— per Florida Building Code Section 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 2322.3 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. DETAIL A it 5/8" thick / 5 ply APA rated plywood _ sheathing in accordance with Florida Building Code Section 2322.3 PRODUCT DESCRIPTION HardiePlank®, Cemplank®, & Prevail® Plank Lap Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building -Code. PANEL DIMENSIONS Water -resistive Width Length Thickness barrier per Florida <9-1/2" 12' 5/16" Building Code Section 1404.2 DESIGN PRESSURE RATING 2" X 4" S-P-F Installation Design Pressure Wood Studs Wood Studs -92 psf Lap Siding Impact Resistant - C_ Planks installed over 5/8" thick / 5 ply g_g 1-1/4" tall X 5/16" APA rated plywood sheathing thick starter strip HARDIEPLANK. CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS ■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturers installation recommendations, and the applicable sections of the Florida Building Code. • Wood studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to the studs in accordance with Florida Building Code Section 2322.3. • Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide laps at the top of the plank such that the exposure area of each plank is <- 8-1/4" vertically. • [Note 2] The siding fastener shall be a 2-1/2" long, 0.223" head diameter, 0.092" shank diameter, corrosion -resistant siding nail; The siding is fastened:5 8-1/4" O.C. vertically and 16" O.C. horizontally; fasteners are driven into wood studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4" from the bottom edge of the overlapping plank. • Vertical joints shall be placed over studs. • The planks shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum of 2"X4" S-P-F wood studs spaced a maximum of 16" O.C. • Fasteners shall have a minimum edge distance of 3/8". HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm -Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator: E. Gonzales SCALE 112" = 1'-0" Date: 9/29/2020 1 SHEET 5 OF 12 Fastener Spacing per Florida E Building Code Section 2322.3�� ----------- --- _..,- ------ ----------------------------------- _ - ----------- - - ; -------------------- <_8.25in. FRAMING • NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 2322.3 CLADDING • PLANKS OVERLAP 1-1/4" • THE EXPOSURE IS <_8-1/4" • THE PLANKS ARE FACE NAILED WITH 2-1/2" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION - RESISTANT SIDING NAILS, PLACED 3/4" UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION �--16 in. OC--� Cladding Framing I Fastener Spacing per Florida Building Code Section 2322.3 If Sheathing a ■ • ENO, 1 ------------ III • _ _ fiTA;_F 6F 40 ,rram'.. i E t rsJ F-ORlO� FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. i 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO Fax 909-427-0634 A PNL-PLK-SOFF Creator: E. Gonzales SCALE 1 = 1 •-0" Date: 9/29/2020 1 SHEET 6 OF 12 REV 2 Stud Spacing at 16" O.C. WALL LENGTH SEE __I N DETAPL A Bt- ---------- -- ------ .......---- y , , ------ -- - / 5/8" thick / 5 p PA •- -- ----- r._ f \\� F3�/}t� r rated plywood y A sheathing fastened Z. ,•�� �'NC- to metal studs as r s ' described in Note 1 WALL HEIGHT 3 _ Water -resistive - barrier per Florida r p�; E OF lrj Building Code •�� Section 1404.2 20ga. 3-5/8" X 1-5/8" Metal C-stud ' HardiePlank, J 1\ Cempiank, Prevail B F SECTIO \ Lap Siding 3/4" Minimum Edge Distance Nails at 16" O.C. (typ.) B-B 1-1/4" tall X 5/16" thick starter strip Sheathing fastener, as described in Note 1 Siding fastener, as described in Note 2 i HardiePlank, Cemplank, Prevail Lap Siding Water -resistive barrier per Florida Building Code Section 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened to metal studs as described in Note 1 20ga, 3-5/8" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. PRODUCT DESCRIPTION HardiePlank®, CemplankO, and Prevail® Plank Lap Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building Code. PLANK DIMENSIONS Width Length Thickness <_ 9-1/2" 12' 5/16" DESIGN PRESSURE RATING Installation Design Pressure Metal Studs -92 psf Impact Resistant - Planks installed over 5/8" thick / 5 ply APA rated plywood sheathing HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING ILLATION DETAILS ■ All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. ■ Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel edges and all intermediate supports using a No.8-18, 0.315" head diameter 1-1/4" long bugle head screw • Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide laps at the top of the plank such that the exposure area of each plank is <_ 8-1/4" vertically. • [Note 2] The siding fastener shall be a minimum No. 8-18, 0.315" head diameter X 2-1/4" long" bugle head screw over metal studs (*or screw shall have at least 3 full threads penetrating metal framing); The siding is fastened:5 8-1/4" O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4" from the bottom edge of the overlapping plank. Vertical joints shall be placed over studs. ■ The planks shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C. • Fasteners shall have a minimum edge distance of 3/8". HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue 77-- Fontana, CA 92337 09-356-6300 SIZE FSCM NO DWG NO REV 9-427-0634A PNL-PLK-SOFF 2 reator: . Gonzales SCALE 1 /2" = 1'-0" Date: 9/29/2020 1 SHEET 7 OF 12 6.00in. �--16 in. OC--� Cladding 6.00in, Framing ~ F 6.00in.00 , Sheathing 0.751n ` `�.._............... �_._ :........ ........ ------------- ---------- ---------------- • � 58.25in. FRAMING ■ NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/8" LONG RIBBED BUGLE HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE HEAD SCREW CLADDING • PLANKS OVERLAP 1-1/4" • THE EXPOSURE IS <_ 8-1/4" • THE PLANKS ARE FASTENED WITH NO. 8-18, 0.315" HEAD DIAMETER X 2-1/4" LONG CORROSION - RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3/4" UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION •` A• r f'' 1662 -- '2 29 21 OF , R 10 AL 0�.�\\�`f 12gf ZD FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GIRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING al) INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator: E. Gonzales SCALE 1" =1'-0" Date: 9/29/2020 ISHEET 8 OF 12 DETAIL A r 1 a WALL LENGTH Stud Spacing at 16" O.C, B 4---, 1 1 i I Nails at 4" O.C. (typ.) 3/8" Minimum Edge Distance SEE PRODUCT DESCRIPTION DETAIL A HardieSoffit® & Cemsoffit® materials are J nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A l and meeting the requirements of the Florida Building Code. 2" X 4" S-P-F SOFFIT DIMENSIONS Width Length Thickness Wood Studs 4' 8' 1 /4" DESIGN PRESSURE RATING HardieSoffit, Installation Design Pressure Cemsoffit Wood Studs -70 psf M SECTION B-B - �' • ��� ix ,gE OF r� �.. HARDIESOFFIT. CEMSOFFIT PANEL INSTALLATION DETAILS soffit fastener, as d All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's escribed in Note 1 installation recommendations, and the applicable sections of the Florida Building Code. Wood studs where HardieSoffit, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. HardieSoffit, Cemsoffit The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C. i [Note 1] The soffit fastener shall be a 2" long, 0.223" head diameter, 0.092" shank -diameter, corrosion resistant siding nail; the fasteners shall be spaced at 4" O.C. at panel edges and intermediate studs; the fasteners shall be driven into wood studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners. Minimum 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. # 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator: E. Gonzales SCALE 1 t2" = 1'-0" Date: 9/29/2020 SHEET 9 OF 12 FRAMING NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING THE SOFFIT IS FASTENED WITH 2" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS 16.00in. FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO Fax 909-427-0634 A PNL-PLK-SOFF Creator: E. Gonzales SCALE V = V-0" Date: 9/29/2020 1 SHEET 10 OF 12 7-0 REV 2 -- --—WALL LENGTH Stud Spacing at 16" O.C. B 4-- I I . is I I WALL ! HEIGHT I •i I i i? i ii DETAIL A i i" ;i i �I Nails at 6" O.C. (typ.) 3/8" Minimum Edge Distance Soffit fastener, as described in Note 1 HardieSoffit, Cemsoffit 20ga, 3-5/8" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. SEE PRODUCT DESCRIPTION DETAIL A HardieSoffit® & Cemsoffit® materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 ' l Grade II, Type A and meeting the requirements of the Florida Building Code. 20ga, 3-5/8" X 1-5/8" SOFFIT DIMENSIONS /Metal C-stud Width Length Thickness 4- 8' '/e" HardieSoffit, A,-' Cemsoffit DESIGN PRESSURE RATING Installation 4gli n Pressure Metal S€ud\s��1� 5f SECTION B-B No. 81662E OF P���\�� LOR10AL 1�111111\ HARDIESOFFIT. CEMSOFFIT PANEL INSTALLATION DETAILS • All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. • Metal studs where HardieSoffit, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • The soffit shall be installed over minimum 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C. • [Note 1] The soffit fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-1/4" long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal framing);the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven into metal studs located at 16" O.C. • Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners. HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 SIZE I FSCM NO Fax 909-427-0634 A I Creator: E. Gonzales SCALE 1/2" = V-0" DWG NO PNL-PLK-SOFF Date: 9/29/2020 1 SHEET 11 OF 12 REV 6.00in:� � �16.00in. •ll 6.00in. ^'—'ding aming 0�0'11liIfJ1}}CC Ni' • � � Via, $166 `� • • f • • • • • • • • • • • / '% $SATE OF lrj ti /0NA -- I fr FRAMING • NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING HARDIESOFFIT, CEMSOFFIT PANEL THE SOFFIT IS FASTENED WITH NO. 8-18, 0.315" HEAD INSTALLATION DETAILS METAL STUD CONSTRUCTION DIAMETER X 1-1/4 " LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 111911 FULL THREADS PENETRATING THE METAL FRAMING), PLACE James Hardie Building Products, Inc. SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE 10901 Elm Avenue STUDS Fontana CA 92337 Phone: 909-356-6300 SIZE FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 9 Creator: E. Gonzales SCALE 1" = 1'-IY' Date: 9/29/2020 1 SHEET 12 OF 12