Loading...
HomeMy WebLinkAboutConstruction Planr- - ---------- - --� -- a i s � s � : i S' 6 B 1 8 i 9 g i Jurisdiction: City i of Port St. Lucie FL A BC 2020 Code. FRC/II Project Address: 88 2 FIRST TEE RD. Project Name' CH ALMERSOPNG Architect/Engineer: - Paul Welch P.E. Type of Const ruction: CBS Frame: BuildingDes igned: ied: Enclosed X Open Partially Enclosed 3 second gust) Vu[C 160 Wind Speed e mph W� p ( g ) P nominal Vaed: 124 m Wind Speed h p P Exposure: C Internal Pressure Coefficient: 0.18 Importance Factor: 1.0 Building Risk Ca egory 2 (1,2,3, or 4) Mean Building Height: 15.3 ft Overhang: 1 ft Roof Pitch: ' 5 / 12 ® a Components & Cladding Wind Pressures: + 33.6 7 -44.9 PSF (ACTUAL BUILDING DESIGN PRESSURES FOR WINDOWS AND DOO LISTED ON PLANS) _ Roof Dead Load: 5 Live Load: 20 Framed Floor Live Load. N/A P sf Dead Load N/A Shutters: Yes. No X Impact Resist ant Assembly: Yes X No City of Port St. Lucie Building Dep art Product Approval Sub ' ent ffidavit pp Itllttal A Permit # Build ng Address: ON PLAN Contractor: TBA ch due 0 enin S e p g d Doors Windows & Skylights : Swin doors Overhead Sliding Doors Fixed Glass , g g Opening ID FL # or NOA # Product Model # ', ManufacturerDescription Glass n Size, Attachment Type, S e yp , Building g ct Spacing & Embedment (DISTANCE Design FROM CORNER DISTANCE O.C.) Pressure Pressure S.H. FL# 14911.5 SH WINDOW 2127 SILVERLINE IMPACT #10 X 1 1/2" MIN. EMBED SCREWS +33.6 / +55/-60 WINDOW „ ,r AT 6.25 12.5 O.C. -36.4 Product Model# Manufacturer Attachment Method - Type, Attach Yp , Building c g Product Size, Spacing, Embedment & Stiffener etc. Desi n Design Pressure Pressure Mullions N/A Roof N/A Soffit N/A :Hurricane A N/A Panels I have reviewed the above product .,.ppr, info matipn and approve it. Name: Paul Welch P.E. 29945 ter, IGzTIr-�1 /: DRYW ALL WALLS AP R- 13 INSU LATION CC N � IIS 0 F . i S T U , 5, REMOVE EX STING 6080 S.G.D. FRAME IN O ENINING AND y INSTALL 36" 50" S.H. WINDOW 1 ti 1 =1 pA1� IAL SIDE ELEVATION ' 11-0" EXISTING ROOF SYSTEM EXISTING CONCRETE BEAM EXISTING CMU WALL - - - -- EXISTING CONCRETE BEA 2 X 8 P.T. WOOD TOP PLATE ITH %d' X 3" TAPCONS AT 12" O.0 - STUCCO FINISH PER STRUCTURAL NOTE#5 STRAP EACH STUD TO TOP AND BOTTOM PLATES WITH SIM SON SP8 WITH (6) -10d NAILS OR SIMPSON H4 WITH (8)- 8d ATTACH P.T. 2 X 8 WOOD ST TO EXISTING CMU WALL AND COLUMN WITH''/," X 3" TAP ONS AT 12" O.C. VERT. 2 X 8 WOOD STUD AT 16" O. . _ (PROVIDE (2) STUDS EACH Sl DE OF WINDOWS) P.T. 2 X 8 WOOD BOTTOM PLATE _ -` WITH/4" X 3" TAPCONS AT 1 " O.C. WEEP SCREED PER STRUCT>RAL NOTE#6 EXISTING CONCRETE FOUN ATION FINISHED GRADE SECTION Si PE OF WORK REMOVE EXISTING SLIDING GLASS DOOR, FRAME IN OPENING AND INSTALL NEW WINDOW PER PLAN. THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2020 FOR EXISTING BUILDINGS CHAPTER 7 AND 8. )D. NO -ES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT SHALL VERIFY ALL DIMENSIONS CONDITIONS AT JOB SITE PLANS SPECIFICATIONS ECT 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER ASCONSTRUCTION PROGRESSES. 3 ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS 4 ALL CONSTRUCTIONMUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2020 AND FBC 2020 RESIDENTIAL. ENTIAL. 5 RESIDENCE LOCATED IN NEGLIGIBLE G IGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. 6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 2020 FOR EXISTING BUILDINGS. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-16. 2) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE ' PRESSURE TREATED. 3) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 4 UNLESS OTHERWISE NOTED THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES 5) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH I GA. 2" LONG NAILS WITH 318" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 19/32" CDX PLYWOOD WITH IOD NAILS TO STUDS @ 6 O.C. PERIMETER AND FIELD 6) WEEP SCREEDS A MINIMUM 0.019 INCH (0.48 MM) (NO.26 GALVANIZED. SHEET GAGE), CORROSION -RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3'h INCHES (89 MM) SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES (51 MM) , ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER -RESISTIVE BARRIER SHALL LAP THE ATTACHMENT FLANGE: THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE. ATTACHMENT FLANGE OF THE WEEP SCREED. WALL FINISH /INSULATION NOTES 1) INTERIOR TO BE%" DRYWALL FINISH. 2) ALL INTERIOR GYPSUM BOARD TO BE MIN. %" THICK WITH (13' GAGE, 13/8" LONG, 19/64" HEAD; 0.098" DIAMETER, 1 ''/a" LONG, ANNULAR -RINGED; SD COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 15/64" HEAD; OR GYPSUM BOARD NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32"HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3) WALL AND CEILING FINISHES SHALL HAVE A.SMOKE-DEVELOPED INDEX OF NOT GREATER THAN 450, 4) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. S) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 6) ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 7) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. Z/ O OW DETAIL