Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutOwens Corning Duration FL #10674 Florida Building Code Online Page 1 of 2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
Florida
r
4 tap1 Product Approval
.dam'' USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail '
FL# FL10674-R16 N
Application Type Revision
Code Version 2020 � L v
Application Status Pending FBC Approval
Comments FLV4
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
V; Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R16 COI 2020 01 COI NIEMINEN.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2019
Equivalence of Product Standards
Certified By
Sections from the Code
httn_//www.floridahuilclina_nra/nr/nr nnn rltLnsnx?nnrnm=wCTFVXC)wtT)ntRNh-P.ViV%,?h )/14/?n?l
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 12/11/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R16.Ddf
Impact Resistant:N/A Verified By: Robert J. M.Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.odf
Created by Independent Third Party:Yes
Oack Next
Contact Us 2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click hem.
Product Approval Accepts:
Iftol eChec_I
Credit Card
Safe
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2b... 2/4/2021
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-1111
One Owens Corning Parkway FL10674-1116
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7' Edition(2020) Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
w".�•.._�,.. as •.*-
Robert J.M. Nieminen, P.E.
}:'•�r The facsimile seal appearing was authorized by Robert
,;fib°gas.; ;;.
S'.• c,•,.• Nieminen,P.E.on 12/11/2020.This does not serve as an
Florida Registration No.59166,Florida DCAANE1983 "=rr.',�;;;;`" electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2018 NEMO ETC,LLC
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5,R905.2.4 Material standard ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2019
3. REFERENCES:
Enti Examination Reference Date
Owens Corning Declaration Equivalency Declaration 08/06/2019
PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
PRI(QUA9110) Quality Control Service Confirmation 04/05/2020
PRI(QUA9110) Quality Control Florida BCIS Current
4. PRODUCT DESCRIPTION:
TABLE 1:ASPHALT SHINGLE COMPONENTS
Type Product Plant(s) Material Description
Standard
Starter Strip Shingle H-TX,OR
Accessory Starter Strip Plus MN,OR ASTM D3462 starter strips for asphalt roof shingles
Starter SRS TopShield Starter MN,OR
Strips mineral-surfaced,fiberglass-reinforced,
Starter Shingle Roll NH ASTM D1970 self-adhering SBS modified bitumen starter
Supreme* GA,CA,CO,I-TX,NJ,OH, ASTM D3462 fiberglass reinforced 3-tab asphalt
TN,OR,IL roof shingles
Berkshire' MN ASTM D3462 fiberglass reinforced,4-tab asphalt
roof shingles
Duration'Premium CA,OR
Asphalt Duration'Premium COOL CA
ru a inition°Duration°
Shingles ° IN,CA,CO,I-TX,FL,NJ,OH,
DesignTruDeer
Colo Duration MN,OR,GA,IL,TN fiberglass reinforced,laminated
Designer Color Collection ASTM D3462
GA,IN,CA,CO,H-TX,I-TX, asphalt roof shingles
Oakridge° FL,NJ OH,TN
TruDefinition°Oakridge° H-TX,I-TX
WeatherGuard°HP TN
NEMO ETC,LLC Evaluation Report 037940.02.12-R31
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
\ r Page 2 of 10
ONEMOJetc.
TABLE 1:ASPHALT SHINGLE COMPONENTS
Type Product Plant Materials) Standard Description
Berkshire'Hip and Ridge MN
Shingles with Sealant
Hip and DuraRidgem Hip and Ridge MN fiberglass reinforced,hip and ridge
Ridge Shingles with Sealant ASTM D3462 asphalt roof shingles
Shingles ProEdge GA,CA,OH,OR
WeatherGuard°HP Hip and TN
Ridge Shingles
S. WITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications
TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES
Product FBC Table 1507.2.7.1 or R905.2.6.1
Supreme'
Berkshire'
Duration'Premium
Duration'Premium COOL
uDefinition°Duratio ASTM D3161(F)&ASTM D7158(H)
TruDefinition°Duration*Designer Color Collection
Oakridge°
TruDefinition°Oakridge°
WeatherGuard°HP
5.5.1 Classification by ASTM D7158:
ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO ETC,LLC Evaluation Report 037940.02.12-Rll
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 3 of 10
ONEIVIOletc.
TABLE 213:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE
Type Product FBC Table 1507.2.7.1 or R905.2.6.1
Starter Strip Shingle
Starter Strips Starter Strip Plus ASTM D3161,Class F
SRS TopShield Starter
Berkshire"Hip and Ridge Shingles with Sealant
Hip&Ridge DuraRidge®Hip and Ridge Shingles with Sealant
ASTM D3161,Class F
Shingles ProEdge®
WeatherGuard"HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
INSTALLATION:6.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off) or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five(5)nails per strip.
Felt underlayment ' Deck FA underlayment Deck SelLadhared
_ Weatherlack-1
Self-adhered - underlayment
i WeatherLocke
underlayment
Drip edge
Drip — - Drip edge Drip
edge edge
Nails located Nair located
2'-T'from eave 2"-3"from save
Install first Self-sealing adhesive SeFsealing adhesive
Starter Strip positioned along Instal positioned along save
shingle with \ with 6"removed \
6"removed
Starter Strip shingle overhangs eaves and rakes 114=1i+' Starter Strip Plus overhangs eaves and rakes 114"-3/4'
Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus
NEMO ETC,LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization N32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1316
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 4of10
OONEMO etc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Underlayment
Drip edge
Drip edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3:Starter Shingle Roll
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Berkshire"shingles require minimum five(5) nails per shingle.
➢ WeatherGuard" HP shingles require minimum six(6)nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
.m T. .
Normal Mansard or Area pare Normal Mansard or Area pars
Wind Areas High Wind desvanes y Wind Areas High Wind deavanes y
Area pare vientos normales Areas vientos fuerres Area para vientos normalas Areas vientos Mertes
r tt" (A) T.r 2- (B] (A) t rt� s� (B) {Z. t„
12 1 72 1
5"Exposure 5 5/8"Exposure
Exposici6n Exposici6n
Figure 4:Minimum Nailing,Supreme Figure 5:Minimum Nailing,Supreme
(Standard Size) (Metric Size)
NEIVIO ETC,LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVH2 EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 5 of 10
NNEMO etc.
6.3.1.2 Berkshire®:
Sealant strip Sealant strip
La lira fie sellador La tire de sellador
A Vt' A Vi" A VP V 8 1h" 8 1h" 8 rh" 8 1/2" }
r
f
r
Figure 6: S-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire
Sealant strip
La lira de scliarbr
• f••4---------)• •4------!• i•
A 112, AY" A Vt' A 1/t'
t ,.. 1
2 Asphalt roofing cement
Cemenlo de(echo de aslaho
Figure 8: Mansard or Steep Slope Pattern,Berkshire
NEMO ETC,LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 6 of 10
ONEMOjetc.
6.3.1.3 Duration® Premium T Definition® Duration uration® Premium COOL & TruDefinition' Duration' Designer Color
Collection:
4-Nail Fastening Pattern
SureNall®fastening area width
Nail,Typical
1" 12" 12" 1"
•`wens Coming S—N,il • ml! insW suawa • 0—coming SWM*e •
6-1l8" 5-5l8"
eepouwe
Figure 9:Standard 4-Nail Pattern,Duration
6-Nail Fastening Pattern
SureNaiIG fastening area width
Nail,Typical
1" 12" 12" 1"
&wens C.'a.2 Su Haile Ij
•Owens Coming SureNai� •
6-1l6" 5.5/8"
.=po+ure
Figure 10: 6-Nail Pattern,Duration
Fastening for Slopes Greater Than 21:12
SureNallO fastening area width
Nall.Typical
1" 12" 12"rt 7"
&wens Coming SiueNaa% • •reNOlns gu�uio�suawo •?wem Coi nlnp SureNad V) •
6-118" 5.518"
exposure
�2n
Four 1"Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern,Duration
NEMO ETC,LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 7 of 30
c-�
NNEMOletc.
6.3.1.4 TruDefinition`Oakridge®,Oakridge®:
4 Nail Pattern 6 Nail Pattern
Esquema con 4 clavos Esquema con 6 clavos
IE— 12" 12'
IE- -e-- 12'—>•I
5 5/9"Exposure Nails
5/8"Exposure Nails
Exposieit5nde55/8pu1g. clavos Fxposicidnde66J8puig. 5 5/8"Exposure Ctavos 55/8"Exposure
Fxposicidn de 5 5/8 pulg. Fxposicidn de 5 5/8 pu1g.
Figure 12:Standard 4-Nail Pattern,Oakridge Figure 13:6-Nail Pattern,Oakridge
Fastening for Slopes Greater Than 21:12
SureNail@ fastening area width
Nall,Typical
a*.ma c«nw Swor:al • ar+,ms a.w"�.w.a •or"mcamrw svesar- •
6.1I8" 5.516"
e.umw.
2"
Four 1"Spots of Asphalt Roofing Cement
Figure 14:Mansard or Steep-Slope Pattern,Oakridge
6.3.1.5 WeatherGuard®HP:
6 Nail Pattern
Esquema con 6 clavos Nail 6 11B"from bottom
of shingle
5 518"Exposure 6 Fasteners pave a 6 17 pping.de la
p 6 su etadores parte inferiorr de la tta
r Exposican de 5 578 ping. 1
'fl 1`pig. 12 p,1y,—�I IE_ 12 pig. lig.
w4 1 tug
ti
— IE— 2' —>I IE-- 12 I
12puYp • • . . 12pulg . —
J6it Clams — —
Four 1"Spots of Asphalt Roof Cement
5 5ia Exposure 5 5 s'ER�rive Cuatro puntos de cemento de(echo de asfdto de 1 pulgada
Esposi66n de 5 56 put. Ecposdcitn do 5 5 8 puig.
Figure 15:6-Nail Pattern,WeatherGuard HP Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP
NEMO ETC,LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 8 of 10
ONEMOletc.
6.4 HIP AND RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two(2)nails per shingle.
➢ WeatherGuard" HP Hip and Ridge Shingles and ProEdge®require minimum four(4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire®Hip and Ridge with Sealant and DuraRidge®Hip and Ridge Shingles with Sealant:
Fig. A Fig,. B To View
Prevailing Wind Direction P
Direccion del viento predominante Vista superior
Nail
25/s" Clavo
Nails " • Owens Coming Sulr•Nail` •
Clavos
I I I
I
4 I clw
P I 8" _I �
Q)
tlrExposwe �I,c
IExposicion de 8 pulg V I
4 I
I
P
12"
Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge
6.4.1.2 WeatherGuard®HP Hip and Ridge Shingles:
Fig,A q 4 Fig.C Hip&Ridge Shingle Fastening
Prevailing Wlnq �\ \ Top Vlevr
Direction A
\ A
Nails 4 4
Naps Nails
\ p I I
4 4 I I 7��
I I 2" 2"
I I
AA i i i i •
t" •1 y
Exposure
Exposure
12 �i
Figure 19:Isometric View,WeatherGuard HP Hip and Ridge Figure 20:Plan View,WeatherGuard HP Hip land Ridge
NEMO ETC,LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 9 of 10
ONEMOjetc.
6.4.1.3 ProEdge®:
Prevailing Standardt1„�
Wind Direction Fastening
Sealant Strip Pattern
6'Exposure Z. `z
12' I Sealant
Fasten 7V 7 Jli
6"Expos�e
Cover Exposed
Fasteners with
Roof Cement I> 12" �j
Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 10 of 10