HomeMy WebLinkAboutConstruction Plans2"x2" GALVANIZED WASHER WITHYz" NUT Yx " THREADED ROD NOTCH OR COUNTERSINK BOLT OPTIONAL FOR "HIGH SET" THRU 2"x4" BOTTOM PLATE 1/2" THREADED ROD 1!2"x5" (400 LB) CONCRETE OPTIONAL FOR "HIGH SET" EYES BOLTED TOGETHER WEDGE ANCHOR INTO SLAB WITH y"x2°,B�Q,�.���° NUT.{ I (2)`2"x2" GALVANIZED WAS Yz" COUPLER -� `" ' =' THRU 2"x4" P.T. BOTTOM PLATE (SEE TABLE 1 FOR SPACING) 2"x4" BOTTOM PLATE NAILED 1/2" COUPLER (2,000LB SHEAR CAPACITY) 4" MIN. TO 2"x6" P.T. BASE 1/2"x12" FORGED EYEBOLT r 4" MIN. Y"x 3" (400 LB) WEDGE ANCHOR SIMPSON A-24 C NCRETE SLAB BY OTHERS ia_________ _ ____� THROUGH LOCAL CODES EYES BOLTED TOGETHER W/ 1/2"x2" BOLT & NUT WITH (2)2"x2" GALVANIZED r CONCRETE (SEE TABLE 1 FOR SPACING) CLIP OR EQUAL AND JURISDICTION CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES WASHERS (2,000LB SHEAR CAPACITaI� f .. AND JURISDICTION ((= 30" EARTH AUGER ANCHOR SHED WITH SKID SHED WITH'NO FLOOR' OPTION' (SEE TABLE 4 FOR SPACING), ANCHORED TO CONCRETE ANCHORED TO CONCRETE " SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT OF THE GROUND AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING, HOLES ARE DRILLED THRU THE 2"X4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 112" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF THE RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT A'NO FLOOR' OPTION, ANCHOR WITH 1/2"X5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. Q o_ 2 O U z c7 en w cn g a Of ❑ 0 0 N F- S ❑ z OL O U TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPAC'G 20'-0" 400 T-6" 1Y-8" 280 T-6" 11'-8" - 240 -3'-6"- 10'-0" 200 3%6" B'-0" 160 T-6" V-0" 120 T-6" SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1) J x4j" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 2 SKID RUNNER SPACING' SHED WIDTH X1 X2 X3 13'-8" 1'-10 1'-10}" 1'-10� 11'-8" 2'-B" 6'4" 10'-0`-- V-7" - - 6'-10" - _ - B'-0" 9" 6'-6" V-0" 10" 51" VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 1 V-8" AND 13'-8" WIDE SHEDS ONLY. TABLE 3A PAD TYPES TYPE PAD DIMS MAX LOAD` MATERIAL I 2"x8"X16" 1778 LBS CONC. BLOCK Q07UTY- CEMENT AND SAND MIX II 4"x8"X16" 3500 LBS -TOIT=OCK QUALITY CEMENT AND SAND MIX -III-- - -16"X16" 3950-LBS- -- ABS PLASTIC PADS IV 81X8"X16" 1900 LBS CONIC.L CEMENT AND SAND MIX BASED ON 2000 PSF SOIL BEARING CAPACITY (2000 PSF IS TYPICAL) NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"xl6") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 1 T-B" AND 13'-8" WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW (PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-B" SW/DW 4.15/332 0" TO 6" 6'-0" 1936 LB 1, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 0" TO 6" 6'-0" 2558 LB I, II, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6" 6'-0" 2400 LB 1, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0" TO 6" 6'-0" 2029 LB 1, II, III, OR IV 2133LB I, II, III, OR IV 6-0" SW 3.00/240 0" TO 6" 6-0" 1658 LB I, II, III, OR IV 1866LB I, If. III, OR IV ' LOAD WIDTH OF UPLIFT ON RUNNER NOTES: 1. PAD SPACING IS END TO CENTER OF PAD 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING 2"x2" GALVANIZED WASHER WITHy" NUT GRADE IV PAD WITH CODE INFORMATION CODE VERSION BC-7TH,EDITIO- (20.20 �r AS C E,.7y1.6�' MANUFACTURER SUPERIQR,SHE_DS, ~ BUILDING TYPE '-MANUF. SHED CONSTRUCTION V-B CODE VERSION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NO. OF STORIES 1 BASIC WIND SPEED 180 MPH (VULT) EXPOSURE C ENCLOSURE---- --ENCLOSED - INTERNAL PRESSURE COEF. +/- 0.18 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10 PSF ROOF LIVE LOAD 20 PSF OR 300LBS FLOOR DEAD LOAD 8 PSF FLOOR LIVE LOAD 75 PSF / 125 PSF "R" RATING (WALL, FLOOR, ROOF) N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 720 S.F. l- GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHORS BY HOME PRIDE OF BRISTOL, VA. OR EQUIVALENT. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,725 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED. ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING" 13'-8" 7.00 243 0'-0" TO X-0" 10'-0" 11'-8" 6.00 208 0'-0" TO 3'-0" 10'-0" �500 174- --- -� -D!KT0 X'� - 0" 8'-0" 4.00 138 0'-0" TO 3'-0" 10'-0" 6'-W 3.00 104 0'-0" TO X-0" TABLE 4B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW- UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING 20'-0" 10.00 400 1 0'-0" TO V-0" 1 5'-0" ' LOAD WIDTH UPLIFT ON RUNNER LOCATION FROM END WALL OF AUGER ANCHOR MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER 3. THE MINIMUM NUMBER F ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. y ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. GENERAL NOTES: 1. FOUNDATION PLANS ARE NOT PART OF THIS '` %° PLAN SET AND ARE GOVERNED BY LOCAL ' �,.„,,, ` JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 'FSS�aN 1015.22 --3. REFER TO TIE -DOWN -DETAILS -FOR PROPER Digitally SI signed b g Y INSTALLATION REQUIREMENTS TO MEET CODE. Julio Orbegoso Date: 2021.02.01 16:42:51-05'00' SHED STRUCTURE FOR: "'` ~n `�°'g� DATE: 01-22-2021 SUPERIOR SHEDS i (877) 439-7433 DRAWN: R.L.G. 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 &03 If.00 SS FOUNDATION ..................... < ._ a........,..-_ MODULAR PLANS DESIGN, CO. �e ® � %� SHEET NO. roc MODULAR x, DDFLORI AUITE,�S OFF FAX86633.fi6887/18 PLANS DESIGN, CO. 33813 COLE®MODULARPLANSCO.COM Al z n. 2 0 z 0 w U) z 3 a J 0 0 0 N N S OL O 0 O NOT 'APPROVED FQR MVHZ .: STRUCTURAL LOAD LIMITATIONS WIND LOAD CRITERIA 1. 132 Vasd/170 Vult WIND SPEED (MPH) 2. 1 RISK CATEGORY 3. II BUILDING CATEGORY 4. ENCLOSED ENCLOSURE CLASSIFICATION 5. GCpI = 0.18 INTERNAL PRESSURE COEFFICIENT 5. C EXPOSURE FACTOR 6. 0.85 WIND DIRECTIONALITY FACTOR (Kd) 7. 0.85 GUST RESPONSE FACTOR (Gh) 8. Pr = -93.0 PSF MAIN FRAME STRUCTURE OVERTURNING LOAD 9. COMPONENT & CLADDING LOAD (ROOF) Pr = ZONE 1: -35.63 PSF, ZONE 2: -35.63 PSF, ZONE 1-65.26 PSF (WALL) PW = ZONE 4: -39.14 PSF, ZONE 5: -46.89 PSF 10. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT ON THE UPPER HALF OF A HILL OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT. SEISMIC LOAD: N/A FLOOD LOAD: THIS BUILDING IS NOT DESIGNED TO BE SUBMERGED OR SUBJECTED TO WAVE ACTION WHEN LOCATED IN A FLOOD PRONE OR ZONE AREA. FINISH FLOOR ELEVATION MUST BE LOCATED ABOVE THE BUILDING SITE FLOOD PLANE LEVEL. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE REGULATIONS. DRAWING INDEX C1 COVER SHEET Al FLOOR PLAN A2 SIDEWALL FRAMING A3 FLOOR FRAMING A4 ROOF FRAMING A5 CROSS SECTIONS A6 ENDWALL FRAMING A7 SCHEDULES *1 Please note: Any questions regarding local permitting should be directed to the Manufacturer. The Manufacturer's contact information can be found in the title block of the plans. 2323 S. VOLUSIA AVENUE ORANGE CITY, FLORIDA 32763 (877) 439-7433 GENERALNOTES 1. FOUNDATION PLANS ARE NOT PARTOF THIS PLAN SETAND ARE GOVERNEDBY LOCAL JURISDICTION. 2. BUILDINGS ARE APPROVED FOR RESIDENTIAL LAWN STORAGEONLY 3. THIS BUILDING IS EXEMPT FROMTHE FECC PERSECTIONS R101.4.2.4, R402.1. 4. REFER TO TIE DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEETCODE. 5. ALL LUMBER FOR CONSTRUCTION WILL BE #2 SYP EXCEPT AS NOTED. 6. GUTTERS SHALL BE SITE INSTALLED PERTHE LOCAL AUTHORITYHAVING JURISDICTION AND PERMITTING REQUIREMENTS. 7. ALL WINDOWSAND DOORSTO MEETTHE MINIMUM SPECIFICATIONSPERTHE APPROVED PLANS AND THE FLORIDA BUILDING CODE. 8. IN ACCORDANCEWITH FBC 1609.1.2, -STORAGE SHEDSTHAT ARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE FLOORAREAOF 720 SQUARE FEETOR LESS ARE NOT REQUIREDTO COMPLYWITH THE MAN DATORYWINDBORNE DEBRIS IMPACT STANDARDS OF THIS CODE". 9. IN ACCORDANCE WITH FBC 1010.1.1, EXCEPTION(10.) BUILDINGS THATARE400 SQ-FTOR LESS AND THAT ARE INTENDED FOR USE IN CONJUNCTION WITH ONE -AND TWO-FAMILY RESIDENCES ARE NOT SUBJECTTO THE DOOR HEIGHT AND WIDTH REQUIREMENTSOF THIS CODE. STRUCTURES 400 SQ-FTOR MORE SHALL HAVE AN 80" MINIMUM DOOR. 10. IN ACCORDANCE WITH FLORIDASTATUTE553.80 (1)D, LAWN STORAGE BUILDINGS AND STORAGESHEDS BEARING THE INSIGNIA OF APPROVALOF THE DEPARTMENT ARE NOT SUBJECTTO 553.842 (FLORIDA PRODUCTAPPROVALS) BUT SHALL MEET THE DESIGN WIND LOAD REQUIREMENTS OF THE 2020 FBC 7TH EDITION. 11. FLAT METAL STRAPS CAN BE BENT AROUND STRUCTURAL MEMBERS OF WALL STUDS, TRUSSES, CHORDS, ETC. TO HELP SECURE THESE MEMBERS, PROVIDED THATTHE ADDED BEND DOES NOT INTERFERE WITH ANY OF THE EXISTING BREAKS/BENDS IN THE STRAP. _1.2. AS PER FBC SECTION 1626.1 EXCEP_TI01J_(F):_ STORAGE _SHEDSTHATARENOT-DESIGNED FOR_HUMAN___ HABITATION AND THAT HAVE A FLOOR AREA OF LESSTHAN 720 SQUARE FEETOR LESSARE NOT REQUIRED TO COMPLYWITH THE MANDATORY WIN DBORNE DEBRIS IMPACTSTANDARDS OF THIS CODE. 13. COMPONENTS/CLADDING ARE IN COMPLIANCEWITH THE 2020 FBC 7TH EDITION. 14. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE REGULATIONS. 15. IF A WALL IS FRAMED FOR FUTURE HVAC UNITS THAT SHALL BE APPROVED BY THE AHJ AND SHALL COMPLYWITH LOCAL REQUIREMENTS FOR PERMITTING. 16. WINDOWSAND DOORS INSTALLED BY THE CUSTOMER THAT SHALL BE APPROVED BYTHEAHJ AND SHALL COMPLY WITH LOCAL REQUIREMENTS FOR PERMITTING. 17. HVHZ COMPONENTS FOR SHEDS REQUIRE THAT INSTALLATION PER MANUFACTURER'S INSTRUCTIONS. DESIGN PRESSURES DOORS: +/- 20 PSF WINDOWS: +A40.10 PSF NOT APPROVED FOR HVHZ J_ L MODULAR PLANS DESIGN, CO. LISTING AGENCY APPROVAL: TOP LINE ENGINEERING, LLC. BUILDING CODE RESIDENTIAL CODE ELECTRICAL CODE BUILDING TYPE MANUFACTURER AGENCY AGENCY PLAN NUMBER CONSTRUCTION TYPE FIRE PROTECTION FIRE SUPPRESSION SYSTEM OCCUPANCY ALLOWABLE # OF STORIES WIND VELOCITY FIRE RATING OF EXTERIOR WALLS FLOOR LIVE LOAD - STANDARD FLOOR LIVE LOAD - OPTIONAL FLOOR DEAD LOAD ROOF LIVE LOAD ROOF DEAD LOAD "R" RATING OF FLOOR, WALL,&ROOF MODULES PER BUILDING SQUARE FOOTAGE HURRICANE PROTECTION USAGE HURRICANE SHELTER 'USAGE HVHZ APPROVED FBC, 7TH EDITION (2020) FRBC, 7TH EDITION (2020) 2017 NATIONAL ELECTRICAL CODE RESIDENTIAL LAWN STORAGE SHED SUPERIOR SHEDS, LLC TOP LINE ENGINEERING, LLC BUNG-20 V- B NO NO UTILITY 1 170 MPH, EXPOSURE C 0 75 PSF 125 PSF 10 PSF 30 PSF 10 PSF N/A 1 719 SQ/FT MAX. NO NO NO TOP LINE ENGINEERING, LLC 1'LL-TOP LINE ENGINEERING, LL ✓L; STRUCTURAL ENGINEERS Y William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 BUNGALOW SHED __'j MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE„ SUITE 105 OFFICE 863.688.1054 LAKELAND. FLORIDA ---.7 18 33813 COLE@MODULARPLANSCO.COM CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED CEILING J-BOX I I I LINE —4 LINE I I I I I I I SINGLE POLE NtUIKAL G.F.I. SWITCH OUTLET ELECTRICAL NOTES & OPTIONS: - AS PER NEX ARTICLE 330.30Y(B) SECURING OF MC TYPE CABLE. UNLESS OTHERWISE PROVIDED, CABLES SHALL BE SECURED AT INTERVALS NOT EXCEEDING 6FT. CABLES CONTAINING FOUR OR FEWER CONDUCTORS SIZED NO LARGER THAN 10 AWG SHALL BE SECURED WITHIN 12 IN. OF EVERY BOX, CABINET, FITTING, OR OTHER CABLE TERMINATION. - ALL WIRING SHALL BE 14 GAUGE 3-WIRE MC CABLE. - ENCASE IN ALL METAL BOXES. MAXIMUM NO. OF OUTLETS: 7 MAXIMUM NO. OF LIGHTS: 8 ELECTRICAL WIRING DIAGRAM SCALE: NOT TO SCALE NOTE: 1. MIN. GRADE STUDS: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER 2. MIN. ROOF SHEATHING: 29GA CORRUGATED METAL 3. MIN. FLOOR SHEATHING: Y4' PLYWOOD 4. MIN. WALL SHEATHING: D4 ALUMINUM SIDING NOTE: 23" SECTIONS OF 29GA CORRUGATED METAL SIDING FASTENED W/ %4' #8 HEX WASHER SELF DRILLING SCREWS @ 4" ON EDGE & 6" IN FIELD Col h SHED OVERALL LENGTH (MAX. 40'-0") NOTE: SHOWN IS THE 10'-0" x 20'-0" W/ 6'-0" PORCH OPTION �LINE ENGINEERING, L_LC STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SIVII-79, [CC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 FLOOR PLAN NOTE: --SHEDS TO -HAVE A -MAXIMUM— - -- OF 5 DOORS AND 10 WINDOWS BUNGALOW SHED MODULAR STRUCTURE FOR: DATE: 01-19-2021 SUPERIOR SHEDS Julio (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 `r.....R ' Orbego DRAWN: R.L.G. �o...........c0 - NS, •. p . u. No. 2OZ JOB: SS20-BU-NONH MODULAR PLANS DESIGN, CO. 3876 _ 38769 = .O �Q•' O SHEET NO. _ STATE OF 09:03:5 MODULAR 2L��o FLoaDA SUITE 106 OF-863.688.77 8 I —05' A PLANS DESIGN, CO. —13 COLE@MODULARPLANSCO.COM CONSULTING, ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN #BUNG-20 *** NOT HVHZ APPROVED ENDWALL DOOR & WINDOW 61-0" WIDE OR LESS SCALE: NTS OPTIONAL HYDROVENT DETAIL SCALE: NTS YX6" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 BOTTOM 4"X4" SYP #2 HEADER 2"X4" SYP #2 JACK STUD 2"X4"SYP #2 KING STUD 4"X4" HEADER DETAIL SCALE: NTS 0 ED NG (CONT.) I"X4" P.T. SKID (CONT. 2"X4" SYP#2 ROOF TRUSSES @ 24" O.C. VARIES I u 11 12" MAX. SEE HEA JER DETAIL U) w Q VAR 2"X4" SYP #2 STUDS @ 24" O.C. SHED LENGTH (MAX. 40'-0") :D TO SOLE PLATE MING W/ SIMPSON AP w/ 4 -10d NAILS STUD, SECURING JOIST ON BOTTOM A SIDEWALL FRAMING d-NAILS (TYPICAL)- � SCALE: 3/8"=r-o" -- SIDEWALL DOOR & WINDOW (TYP) SCALE: NTS NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. BUNGALOW SHED MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE., SUITE 105. OFFICE: 863.688.1054 LAKELAND, FLORIDA FAX 863.688.7118 33813 COLE®MODULARPLANSCO.COM ENDWALL r>i> „>>>, William E. Neary, III 10649 • akview Pointe.. 2"X4" SYP#2 SOLE PLATE 2"X6" SYP#2 PERIMETER WALL SHEATHING OPTIONS: - Y16" OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM - D4 ALUMINUM SIDING -Y2" ORS/" T1-11 SIDING =JAMES HARDIE PANEL OR-EQUIV-- -- - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 / Julio ORBEC ., Orbego \O r_. JGENSE•OIP ^/ 1 Z '' No. 38769 .� '% 202 1 1 •0 1 STATE OF ` •• FGORIOP �� SS�ONALE?G 09.04.0! � III1111�� -05-0e DATE: 01-19-2021 DRAWN: R.L.G. JOB: SS20-BU-NONH SHEET NO. A2 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED z a a 0 0 z 0 W 0 z 5 a 3 7 0 0 N N F- x C7 a 0 0 ENDWALL DOOR & WINDOW 6-0" WIDE OR LESS SCALE: NTS OPTIONAL HYDROVENT DETAIL SCALE: NTS 3"X6" MITEK MT20 OR EQUIVALENT 2"X4" SYP#2 ROOF TRUSSES @ 24" O.C. i - 2"X4" SYP #2 BOTTOM F LA VARIES 12" MAX. 4"X4" SYP #2 HEADER SEE HEA ER DETAIL 2"X4" SYP #2 JACK STUD LO 2"X4"SYP #2 KING STUD W Q 4"X4" HEADER DETAIL SCALE: NTS FLOOR.DECKING (CONT.) -� I"X4" P.T. SKID (CONT VARIES 2"X4" SYP #2 STUDS @ 24" O.C. SHED LENGTH (MAX. 40'-0") :D TO SOLE PLATE MING W/ SIMPSON AP w/ 4 -10d NAILS 1 STUD, SECURING JOIST ON BOTTOM A SIDEWALL FRAMING d-NAILS-(TYPICAL)- — A2--SCALE: 3/8"=r-0" -- — -- SIDEWALL DOOR & WINDOW (TYP) SCALE: NTS NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. BUNGALOW SHED MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR LAKELAND, FLORIDA OF DICE Bfi38.70 B PLANS DESIGN, CO. —" COLE@MODULARPLANSCO,COM ENDWALL LE TO STRL'CrURAL E E.E G LLC William E. Neary, III i SMP-51, SMI-79, [CC 5185040 I 10649 Oakview Pointe Terrace j Gotha, Florida 34734 2"X4" SYP#2 SOLE PLATE 2"X6" SYP#2 PERIMETER WALL SHEATHING OPTIONS: - %6" OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM - D4 ALUMINUM SIDING -Y2" OR %" T1-11 SIDING = JAMES-HARDIE-PANEL OR-EQUIV..- — - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 / Julio O'R Orbego \p VGENSP-:0'"tS ,: - ' Nc.38769 0 ,, 2021.01 STATE OF 'sS�oNAL�N` 09.04:0� -05'00/ DATE: 01-19-2021 DRAWN: R.L.G. JOB: SS20-BU-NONH SHEET NO. A2; 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED 1m a a O V z U C3 0 ul z 5 o_ 0 O 0 F- S 0 EL O U O SKID RUNNER SPACING* WIDTHS 6-0" 8'-0" 10'-0" 11'-8" 13'-8" A 0'-1011 0'-9" 1'-7" 2'-8" V-10.5" B 5111 6'-6" 6'-10" 61-411 1'-10.511 C *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SKIDS. ��j,•S_ TOP LINE ENGINEERING, LLC STRUCTURAL ENGINEERS r William E. Neary, III S M P-51, S M I-79, I CC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 r- FLOOR SHEATHING Q Q 2-1/2" X 1/2" THRU-BOLT SHED OVERALL LENGTH (MAX. 40'-0") w )OR SHEATHING: " PLYWOOD "-P-TPL-YWOOD - %4" T&G - %" P.T. T&G SIMPSON HL33 HEAVY ANGLE 2"x6" CONTINUOUS P.T. FLOOR JOIST = CONSULTING ENGINEER JULIO ORBEGOSO I I I I 1 1/2" FLORIDA NOTCH BUNGALOW SHED PE LICENSE #38769 4"X4" P.T. SKID l 441 MODULAR STRUCTURE FOR: DATE: 01-19-2021 4-1/2"X1/2" SUPERIOR SHEDS Julio THRU-BOLT (877) 439-7433 """ - Orbego o DRAWN: R.L.G. F2323. VOLUSIA AVE. ORANGE CITY, FL 32763 ` ,��o oRaE�o,, FLOOR JOIST TO SKID CONNECTION °ENSF s ; N".38769 2021.01. JOB: SS20-BU-NONH SCALE:NTS MODULAR PLANS DESIGN, CO. * * srAtEDF --=Y �' �O��P'.fCOR10P.••GG���- SHEET NO. {a 'SS�UNAI E� 09:04:2 MODULAR 202 DORIS DRIVE., SUITE 105 OFFICE: 863.688.1059 -05' 00' LA ..D. PLORIDA PAX:-3.—.7118 A3 PLANS DESIGN, CO. 33813 COLE®MODULARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED .M ® ■ r Z a 2 O U Z C7 fn W 0 9) Z 5 o_ o: S 0 O 0 N N H c� it n- o U O U) Z) .J -j 0 Z w NOTE: INSTALLATION FOR ALL ROOF SHEATHING OPTIONS AS PER MANUFACTURER INSTRUCTIONS SIDEWALL BELOW D4 ALUMINUM ROOFING w w ILd O O 60 ih 2"X4" TRUSSES @ 24" O.C. - - j = 0? RIDGE LINE -j > O w o O Z w -cp' 1"X4" RUNNERS o m a a O O 1 U) 1 C5 SHED LENGTH (MAX. 40'-0") ROOF FRAMING PLAN SCALE: 3/8" = V-0" Tj TOP LINE ENGINEERING, LLC L: STRUCTURAL ENGINEERS v William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED PE LICENSE #38769 MODULAR PLANS DESIGN, CO. MODULARLAKELAND, FLORIDA 105 OFFFAK 863 6SB.71 B PLANS DESIGN, CO. 33973 COLE®MODULARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED MIN. 3:12 2"X4" ROOF TRUSSES MAX. 8:12 @ 24" O.C. 2"X4" SYP#2 COLLAR TIE 2"X5" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 STUDS @ 24" O.C. 2"X4" SYP#2 BLOCKING 4"X4" P.T. SKID (CONT.) - FLOOR DECKING (CONT.) 2"X4" SOLE PLATE IFLOOR JOISTS @ 16" O.C.7 2"X6" PERIMETER Ial I2SI SHED WIDTH (6'4', 8'-0", 10'-0", 1 V-8", 13'-8") A CROSS SECTION 'A' A5 SCALE: 3/8" = V-0" NOTE: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. SISTER STUDS FOR 4'-0" FROM ENDWALL (TYP)1, TYPICAL STUD SPACING 24" O_C_ MAX SISTER STUDS FOR 4'-0" . FROM ENDWALL (TYP). ••NEI O.C.TRUSSES @ 24" I v�� ion io��✓ioi� ✓io���ioi� p Ell SEE HEADE DETAIL LLJ ... . ...... FLOOR• .. STUDS O.C. e s SHED 40 ALL STUDS SECURED TO SOLE PLATE WALL SHEATHING OPTIONS: AND FLOOR FRAMING W/ 0.039" - 3/6" OSB OR SHEATHING EQUIV. OR BETTER (1 MM)x12" STRAP w/ 4 -10d NAILS - CORRUGATED ALUMINUM _ T - -ON OP -INTO -STUD; -SECURING - - - B CROSS SECTION B' - D4 ALUMINUM SIDING INTO RIM JOIST ON BOTTOM A5 SCALE: 3/8"= T-0" -%" OR %" T1-11 SIDING W/ 4-10d NAILS (TYPICAL) - JAMES HARDIE PANEL OR EQUIV _ �•� • Z TOP LINE ENGINEERING,__LLC T LZ, STRUCTURALENGINEERS Y William E. Neary, III SIVIP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 — ENDWALL 2"X4" SOLE PLATE 2"X6" PERIMETER - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) CONSULTING ENGINEER W/ VINYL SIDING JULIO ORBEGOSO FLORIDA BUNGALOW SHED PE LICENSE #38769 MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE.. SUITE 105 OFFICE: 863 688 1054 LAKELAND, FLORIDA FAX. 863.688.7118 33813 COLEQMODULARPLANSCO.COM I / Julio"' Orbego No. 38769 O '% 2021.01 :* 0 STATE OF '',sS/ONALEN`� 09:04:5: DATE: 01-19-2021 DRAWN: R.L.G. 1 JOB: SS20-BU-NONH SHEET NO. i F A5i 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED MIN. 3:12 MAX. 8:12 �i SI @ 4.1 P.C. 2")44" SYP# B 2"X41 SOLE PIIIATE SHED WIDTH (6-0", 8'-0", 10--0", 1 V-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. 2"X5" MITEK MT20 OR EQUIVALENT A ENDWALL FRAMING A6 SCALE: 3/8" = V-0" SHED WIDTH (6'-0", 8'-0", 10'-0", 11-4% 13'-8") B ENDWALL FRAMING A6 SCALE: 3/8" = V-0" "ROOF TRUSSES MIN. 3:12 @ 24" O.C. MAX. 8:12 :4" SYP #2 STUDS @ 24" O.C. SYP#2 BLOCKING 2"X4" SYP#2 SOLE PLATE — (6" PERIMETER 2"X5" MITEK MT20 OR EQUIVALENT (2) 2NX4" HEADER LU Q MAX 36" SHED WIDTH (6'-0", 8'-0", 10'-0", 1 V-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. B ENDWALL FRAMING A6 SCALE: 3/8" = V-0" CONSULTING ENGINEER JULIO ORBEGOSO ° BUNGALOW SHED::] FLORIDA PE LICENSE #38769 Z in o MODULAR STRUCTURE FOR: DATE: 01-19-2021 a SUPERIOR SHEDS Julio T� TOP LINE ENGINEERING. LLC (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 G'%, 7s'- Orbego 0 DRAWN: R.L.G. O STRUCTURAL ENGINEERS 0. No ' ' ° "- 2021.01, JOB: SS20-BU-NONH o William E. Neary, III MODULAR PLANS DESIGN, CO. *769 *— _+: N SMP-51, SMI-79, ICC 5186040 g =Ao'' STATEDF .'41, T� F �ORIDP.•''G\;' 0 SHEET NO. c, S2 10649 Oakview Pointe Terrace S'• S�"NALEN` ((�� Oi.05.07 ii Gotha, Florida 34734 -�- o MODULAR 2-DOR7S DRNE.. SUITE 105 OFFICE: 863.68 AMA � -05 0 A6 O LAKELAND, FLORIDA FAK:863.688.7118 PLANS DESIGN, CO. 33813 COLE@MODULARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED !L 2 O U Z CD UO W z z 5 !L O 0 0 N F- C7 tr a O U O SIMPSON STRONG DRIVE & STRAP - SD SCREW SCHDEULE PART#!DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER H1 435 6-SD9xl.5° 4-SO9x1.5" H11Z 750 6-SD10x2.5" 6-SD10x2.5- H2A 495 5-S09x1.5- 5-SD9xl.5" 2-SD9x1.5° H2.5A 540 5-SD9xl.5° 5-SD9x1.5" H2.5 410 5-SD9x1.5' 5-SD9xl.5' RAFTER H2.5T 545 5 - SO9x1.5" 5 - SD9x1.5' H2A 495 7-SD9xl.5' 5-SD9x1.5° H3 320 4-SD9xl.5' 4-S09xl.5° - H4 280 4 - SD9xl.5° 4 - SD9x1.5" H5 415 4-SD9x1.5" 4-SD90.5- LTSA2 895 6-SD9x1.5' 6-SD9x1.5' LTS-16 1075 6-SD9x1.5' 6-SD9xl.5' LTS-18 1235 6-SD9x1.5' 6-SD9xl.5" LTS-20 1215 6-S09xl.5" 6-SD9xl.5" MTS-12 895 7-SD9xl.5' 7-SD9xl.5" MTS-16 1075 7-SD9xl.5° 7-SD9xl.5" MTS-18 1255 7-SD9xl.5° 7-SD9xl.S" MTS-20 1255 7-SD9xl.5' 7-SD9x1.5° PORCH PART#/DESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 2-SD9x1.5' 2-SD9x1.5" A23 - 4 - SD9xl.5- 4 - SD9xl.5° A33 4-SD9xl.5- 4-SD9xl.5' BTM PLATE PART#/DESC. UPLIFT WALL FASTENER FLOOR FASTENER LSTA-18 1235 7-SD9x1.5" 7-SD9x1.5' TIE -DOWNS PART#/DESC. 1 UPLIFT WALL FASTENER FLOOR FASTENER 20GA. 1-1/4-WIDE 4725 7-SD9x1.5' 518-x30°ANCHOR 1 4300 A ONLY NEEDED ON ALUMINUM SHEATHING WALLS. B. HEADERS OVER 6' SPAN. STRAP & FASTENER SCHEDULE' PART#/DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER H1 400 - 6.8dxl/S' 4-8d RAFTER (B) H11Z 750 6-16dx2.5" 6-16dx2.5' H2A 495 5-8dx1.5' 5.8dxl.5" 2-8dx1.5' H2.5A 535 - 5-8d S-Sd H2.5. 410 5-8d 53d H2.5T 545 5-8d 5-8d H2A 495 7-8dxl.5' 5-8dxl.5" H3 320 4-8d 4-8d H4 235 4-8d 43d H5 265 4-8d 43d LTS-12 620 - 6-10dxl.5" 6-10dx1.5" LTSA6 620 6-10dxl.5' 6-10dxl.5" LTS-18 620 6-10dxl.5' 6-10dxl.5' LTS-20 620 6-10dxl.5" 6-10dx1,5' MTS-12 860 7-10dxl.5" 7-10dx1,5" MTS-16 860 7-10dxl.5" 7-10dxl.5' MTS-18 860 7-10dxl.5" 7-10dxl.5° - MTS-20 860 7-10dxl.5" 7-lOdx1,5" - PORCH PART#/DESC. UPLIFT COLUMN FASTENER RAFTER FASTENER -- - - - - - - - A21 245 2-10dxl.5' 2-10dxl.5" A23 585 4-10dx1.5' 4 -1 Odxl.5' A33 750 4-10d 4-10d BTM PLATE PART#/DESC. UPLIFT I WALL FASTENER FLOOR FASTENER LSTA-18 1110 7 - IOd 7 - 1 Od ----- - HEADER (D) -PART#/DESC. - UPLIFT-- STUDFASTENER-HEADER-FASTENER- TP-35 N/R V-3"x0.131' 5'-3'x0.131" HP40,41,80,81 4725 V-3"x0.131' 5-3"x0.131" TIE -DOWNS PART#/DESC. UPLIFT WALL FASTENER FLOOR FASTENER 20GA. 1-114" WIDE 4725 7-10dx1.5' 518"x30' ANCHOR 4300 ' ALL STRAPS CAN BE SUBSTITUTED WITH AN EQUIVALENT BRAND MEETING SAME STRENGTHS. B. RAFTER TIES TO STUD WALL TO BE AT EVERY CONNECTION FOR 24' O.C. & CAN EVERY OTHER FOR 16" O.C. BUT IS REQUIRED ON CORNERS AND STUDS ADJACENT TO CORNERS. C. ONLY NEEDED ON ALUMINUM & VINYL SHEATHING WALLS. D. HEADERS OVER 6'-0" SPAN. PRODUCT OPTIONS PRODUCT CAT. SUB. CATEGORY MANUFACTURER MODEL 1 DESC. STATE OF FL APPROVAL#: PANEL WALLS SIDING JAMES HARDIE 5/16" CEDAR FL#: 13223.1 PANEL WALLS SIDING JAMES HARDIE 5/16' STUCCO FL#: 13223.2 PANEL WALLS SIDING ADVANCED ALUM, 0.19 GA FL#: 23138.1 PANEL WALLS SIDING PLY GEM X FL#: - PANELWALLS SIDING ADVANCED ALUM. X FL#: 31737.1 PANEL WALLS SIDING SIMPSON LUMBER X FL#: - EXTERIOR DOORS SWINGING EXT EAGAN E1HDL FL#: 12820-R3 EXTERIOR DOORS SWINGING EXT CROFT 2DO 9-LITE FL#: - WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 10853-R5 WINDOWS SINGLE HUNG CROFT VERT SLIDER FLA.' 15527-R5 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 16082-R3 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 16153-Rl WINDOWS HORIZ. SLIDER CROFT HORIZ. SLIDER FL#:27202 WINDOWS HORIZ_ SLIDER CROFT HORIZ. SLIDER FL#:28822 WINDOWS HORIZ. SLIDER CROFT HORIZ. SLIDER FL#:30848 FASTENING SCHEDULE (FBC TABLE 2304.10.1) CONNECTION FASTENING CONNECTION 24. BUILT-UP GIRDER AND BEAMS 20d COMMON (4" X 0.192-) AT 32- O.C. 3" X 0.131 NAILS AT 24' O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE 1. JOIST TO SILL OR GIRDER 3 - 8d COMMON (2 112-X 0.131') TOENAIL 3 - 3' 14 GAUGE STAPLES 3" 14 GAUGE STAPLES AT 24" O.C. 2- 20d COMMON (4° X 0.192-) SIDES 2. BRINGING TO JOIST 2 - 8d COMMON (2 112- X 0.131-) TOENAIL EACH END 2 - 8d COMMON (2 1l2' X 0.131-) 3 - 3" X 0.131" NAILS FACE NAIL AT ENDS AND AT 2 - 3' 14 GAUGE STAPLES 3 - 3" 14 GAUGE STAPLES EACH SPLICE 3. 1'x6" SUBFLOOR OR LESS TO EACH JOIST 2 - 8d COMMON (2 1/2' X 0.131-) FACE NAIL 25.2' PLANKS 16d COMMON (3 112-X 0.162-) AT EACH BEARING 4. WIDER THAN 1'x6° SUBFLOOR TO EACH JOIST 3 - 8d COMMON (2 1l2' X 0.131') FACE NAIL 26. COLLAR TIE TO RAFTER 3 -1 Od COMMON (3° X 0.148-) MIN. 4 - 3' X 0.131" NAILS 4 - 3. 14 GAUGE STAPLES FACE NAIL 5. 2" SUBFLOOR TO JOIST OR GIRDER 2 -16d COMMON (3 112- X 0.162-) BLIND AND FACE NAIL 6. SOLE PLATE TO JOIST OR BLOCKING 16d (3 1/2' X 0.135') AT 16' O.C. TYPICAL FACE NAIL 3" X 0.131 NAILS AT W O.C. 3' 14 GAUGE AT 12' O.C. 27. JACK RAFTER TO HIP 3 -10d COMMON (3- X 0.148') TOE NAIL STAPLES 4 - 3' X 0.131 NAILS SOLE PLATE TO JOIST AT BLOCKING AT 3 -16d COMMON (3 1/2" X 0.135°) AT 16' O.C. 4 - 3" 14 GAUGE STAPLES BRACED WALL PANEL 4 - 3' X 0.131" NAILS AT 16" O.C. BRACED WALL PANEL 2 - 16d COMMON (3 1/2' X 0,162') 4 - 3" 14 GAUGE STAPLES AT 16' O.C. NAILS 3 - 3' X GAUGE 3 - 3' 14 GAUGE STAPLES FACE NAIL 7. TOP PLATE TO STUD 2 - 16tl COMMON (3 1/2' X 0.162') END NAIL 3 - 3" X 0.131" NAILS 28. ROOF RAFTER TO 2-BY RIDGE BEAM 2- 16d COMMON (3 1/2-X 0.162°) TOE NAIL 3 - 3" 14 GAUGE STAPLES 3 - 3' X 0.131 NAILS 3 - 3" 14 GAUGE STAPLES 8. STUD TO SOLE PLATE 4 - 8d COMMON (2 1/2-X 0.131-) TOE NAIL 4 - 3" X 0.131 NAILS 3 - 3. 14 GAUGE STAPLES 2 - 16d COMMON (3 1/2° X 0.162°) 3 - 3' X 0.131' NAILS FACE NAIL 2-1 d COMMON (3 112' X 0.162') 3 - 3' 14 GAUGE STAPLES 3-3 X O.131' NAILS 3 - 3" 14 GAUGE STAPLES END NAIL 29. JOIST TO BAND JOIST 3 -16d COMMON (3 1/2' X 0.135') FACE NAIL 4-3: " X 0.131° NAILS 4 - 314 GAUGE STAPLES 9. DOUBLE STUDS 16d (3 1/2-X 0.135-) AT 24' O.C. FACE NAIL 3' X 0.131 NAILS AT 8' O.C. 3' 14 GAUGE STAPLES AT 8" O.C. 30. LEDGER STRIP 3 -16d COMMON (3 1l2° X 0.162') FACE NAIL AT EACH JOINT 4-3 " X 0.131" NAILS 4 - 3" 14 GAUGE STAPLES 10. DOUBLE TOP PLATES 16d (3 112" X 0.135') AT 16" D.C. TYPICAL FACE NAIL W X 0.131 NAILS AT 8' O.C. 3" 14 GAUGE STAPLES AT 8" O.C. 31. WOOD STRUCTURAL PANELS AND 1/2' AND LESS 6tl C PARTICLEBOARD (B) SUBFLOOR, ROOF AND 2 318-X0.113- NAIL (N) DOUBLE TOP PLATES 8- 16d COMMON (3 1/2' X 0.135°). AT 16. O.C. LAP SPLICE WALL SHEATHING (TO FRAMING) 1 3/4' 16 GAUGE(0) 12-3 X 0.131' NAILS AT 16" O.C. 19/32' TO 314" 8d(D) OR 6d (E) 12 - 3.14 GAUGE STAPLES AT 16" O.C. SINGLE FLOOR (COMBINATION SUBFLOOR- 2 3/8'X0.113' NAIL( 2" 16 GAUGE (P) 6' O.C. EDGES AND INTERMEDIATE, AT COMPONENT AND 11. BLOCKING BETWEEN JOISTS OR RAFTERS 3 - 8d COMMON 2 Ur 0.131 ( ' TOENAIL TO TOP PLATE 3 - 3" X NAILS UNDERLAYMENT TO 19/32" TO 3/4' FRAMING 8d(C) CLADDING EDGE STRIP 3 3-3"14 GAUGE STAPLES GAUGE 111 "T1' 1 118' TO 1 1/4' 10d(D) OR 8d(D) 3/4' AND LESS 6tl((C)) (REFER TO FIG. 30.5.1 OF ASCE 7) 12. RIM JOIST TO TOP PLATE 8d COMMON (2 1/2" X 0.131') AT 6. O.C. TOENAIL 3" X 0.131 ° NAILS AT 6" O.C. 7/8' TO 1' Bd(C) 3" 14 GAUGE STAPLES AT 6" O.C. 1 1/8" TO 1 114" 10d(D) OR Bd(D) 13. TOP PLATES, LAPS AND INTERSECTIONS 2 -16d COMMON (3 1/2-X 0.162-) FACE NAIL 32. PANEL SIDING (TO FRAMING) (Q) 1/2' OR LESS 6d(F) 3 - 3" X 0.131" NAILS 3 - 3" 14 GAUGE STAPLES 518" 8d(F) 14. CONTINUOUS HEADER, TWO PIECES 16d COMMON 3 1/2° X 0.162° 16' O.C. ALONG EDGE 33. FIBERBOARD SHEATHING (G,Q) 1/2' AND LESS NO. 11 GAUGE ROOFING. N'XO.l1 -) COMMON NAIL (2'x0.113') NO. 16 GAUGE 15. CEILING JOISTS TO PLATE 3 - 16d COMMON (3 1/2" X OA31") TOE NAIL 5 - 3' X C.131' NAILS 25132" STAPLE (1) NO. 11 GAUGE 6"O.C. EDGES AND INTERMEDIATE 3 - 3° 14 GAUGE STAPLES NAIL(H) Sd COMMON NAIL (2 1/2'XO.131-) NO. 16 GAUGE STAPLE (1) 16. RIM JOIST TO TOP PLATE _ 4 - 8d COMMON (2 1Y2- X 0.131-) TOE NAIL 17. CEILING JOISTS, LAPS OVER PARTITIONS (SEE TABLE 2308.10.4.1) 3 - 16d COMMON (3 1/2" X 0.135') MIN. FACE NAIL 34. INTERIOR PANELING 4 - 3' X 0.131' NAILS 3%8" 5d(K) 6"O.C. EDGES AND INTERMEDIATE 4 -.3' 14 GAUGE STAPLES 18. CEILING JOISTS TO PARALLEL RAFTERS - 3 - 16d COMMON (3 1/2" X 0.135°) MIN. FACE NAIL A. COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED. B. NAILS SPACED AT 6 INCHES ON CENTER ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES AT (SEE TABLE 2308.10.4.1) 4 - 3" X 0.131" NAILS SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAGRAMS 4 - 3" 14 GAUGE STAPLES AND SHEAR WALLS, REFER TO SE(CTION.2305. NAILS FOR WALL SHETHING ARE PERMITTED TO BE COMMON, BOX OR CASING. C. COMMON D. COMMON OR DE xORMED 8d SHANK2 (6x 0.131"" 10 .1 3 x 0.148112' x 0.131"; 1 Od - 3' x 0.148'). 6d - 2' x 0.113 Btl 2 1/2' z 0.131'; 10tl I' 0.148' E. DEFORMED SHANK.131" 19. RAFTER TO PLATE - 3 - 8d COMMON (2 1/2- X 0.131-) TOE NAIL NAILS 3 -3" 14OGAUGE STAPLES ; - - x F. CORROS77((RESIS .)) G. FASTENERS SPACEDA3 INCHES ODING (N CENTER ATIEXT EXTERIOR EDGESIAQ 6 NOR CHEIS ONG N CENTER AT INTERMEDIATE SU�PORTS, WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, WHEN USED FOR NONSTRUCTURAL SHEATHING. 20. V DIAGONAL BRACE TO EACH STUD & PLATE 2 - 8d COMMON (2 112' X 0.131") FACE NAIL 2-3- X 0.131' NAILS H. CORROSION -RESISTANT ROOFING NAILS WITH 7/16° DIAMETER HEAD AND 1 10 LENGTH FOR 112" SHEATHING AND 1 3/4" LENGTH FOR 3 - 3' 14 GAUGE STAPLES SHEATHING. _I_CORROSION-RESISTANT.STAPLES _WITH.NOMINAL7116'CROWN OR-1--CROWN AND I-1/4'LENGTH- FOR -1/2'FOR 25/32"SHETHING-- --- PANEL SUPPORTS AT 16- (20° IF STRENGTH AXIS IS THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKEDI. K. PANEL SUPPORTS AT 24'. CASING OR FINISH NAILS SPACED AT 6 INCHES ON PANEL EDGES. 12INCHES AT INTERMEDIATE SUPPORTS. L. FOR ROOF SHEATHING APPLICATIONS, 8d NAILS (2112' x 0.113") ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS. APPLISTAPLES SHALL HAVE A CATIONS, MUM CROWN` IDTH OF 7/16" N. OR ROOF SHEATHING CATIONS, FASTENERS SPACED AT 41NCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE 21.7'X8' SHEATHING TO EACH BEARING 3 - Btl COMMON 2 1/2" X 0.131' FACE NAIL 22. WIDER THAN 1"XB' SHEATHING TO EA.BEARING 3 - 8d COMMON (2 1/2-X 0.131.) FACE NAIL 23. BUILT-UP CORNER SUDS 16d COMMON (3 1/2- X 0.162") MIN. 24 :O.C. 3" X 0.131" NAILS 16" O.C. SUPPORTS. 3' 14 GAUGE STAPLES 16' O.C. O. FASTENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND SHEATHING 3 INCHES ON CENTER AT EDGES, 61NCHES AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING. P. FASTENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS. Q. SEE FASTENER ALTERNATE SCHEDULE. R. FASTENERS MUST BE INSTALLED WITH EVEN SPACING BETWEEN THEM ACROSS ATTACHING MEMBER. ALTERNATE FASTENING SCHEDULE CONNECTION FASTENING ALT 31-33. WOOD STRUCTURAL PANELS AND PARTICLEBOARD SUBFLOOR, ROOF AND WALL SHEATHING (TO FRAMING) I 1/2' AND L TT Z TOP LINE ENGINEERING, LLC ice' K, STRUCTURAL ENGINEERS Y William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 LESS 2' X 0.092" RING SHANK NAIL /� � /� � �+ 5'FROM EDGE, 10°O.C. BUNGALOW SHED] MODULAR STRUCTURE FOR: CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 DATE: 01-19-onoi SUPERIOR SHEDS Julio (877) 439-7433 Orbego o DRAWN: R.L.G. 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 "ORB`"' �0........ FGO'% 1 No. 38769 JOB: SS20-BU-NONH MODULAR PLANS DESIGN, CO. =* * s * - _� O po.. STATEDF SHEET NO. -EN :T O0 DEN, 09:05:2 1 MODULAR LAKELAND FLORIDA ITE 105 . OFF AX 88663.fi88.7; 8 -05 0 PLANS DESIGN, CO. 338'3 COLE@MODULARPLANSCO.COM A7 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED