HomeMy WebLinkAboutwindow door scheduleA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone - 10 % of least horizontal dimension or 40 % of the mean roof height, whichever is smaller, but not less than 4 % of least horizontal dimension or 3 ft OPENING LOCATION NUMBER (Location) Corner Zone or Interior IS THIS A WINDOW OR DOOR GLAZING TYPE PRODUCT ACCEPTANCE NUMBER PRODUCT APPROVAL APPROVED PRESSURE RATING REQUIRED OPENING DESIGN PRESSURE MAXIMU M TESTED SIZE ROUGH OPENING DIMENSIONS MULTIPLE WINDOW ARE SHUTTERS REQ Y/N (+) PSF (-) PSF + PSF () (-) PSF MULLION REQY/NlNA l Int Window Tx'`°'°"° FL23505.3 60 65 37.8 .41.0 54x76.5 18x24 No No 2 Int Window 7AS' Laim In FL23505.3 60 65 37.8 -41.0 54x76.5 3507 No No 3 End Window "x"`a'^"° FL23505.3 60 65 37.8 -50.6 54x765 1 3507 No No 4 Int Window 7""`"""° F1,15780.8 55 65 37.4 -40,6 14x165 35x49 No No 5 Int Window 781,1"n'i'o FL15780.8 55 65 37.4 -40.6 54x76.1 35x49 No No 6 Int Window US" 1amiIn FL23505.3 60 65 37.8 -41.0 54x76.5 35x24 No No 7 End Window 7118"Jam In F1,23505.3 60 65 37.2 -49.4 54.x76.5 5106 No No 8 End Window 71s" 1 ami In F1,23505.3 60 65 37.1 49.2 54 x 76.5 5207 No No 9 End Window 7'8'""niIG F1,23505.3 60 65 37.1 49.2 54x76.5 5207 No No 10 End Window "x"J�"°"° F1,23505.3 60 65 37.1 -49.2 54x76.5 5207 No No 11 End Window 718""mlKI FL23505.3 60 65 37.8 -50.6 54x76.5 18x24 No No