Loading...
HomeMy WebLinkAboutA1ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C._________________________________ ___________________________________CLIENT'S APPROVAL DATE CLIENT'S APPROVAL DATE1/13/2021 10:52:14 AM A-1xxxx Noble Oaks LanePort Saint Lucie, FL 34981Al & Maria PereiraDrawing List Sheet Number Sheet Name A-1 Cover Sheet, General Notes, Project Info & Location Map A-2 Notes A-3 Floor Plan A-4 Elevations A-5 Elevations 2 A-6 Details & Schedules A-7 RCP C-1 Site Plan E-1 Electrical Plan E-2 Electrical Notes, Legend, Riser & Calcs M-1 Insulation & Duct Layout P-1 Plumbing Layout PA-1 PGT Casement Window PA-1.2 PGT Casement Window PA-1.3 PGT Picture Window PA-1.4 PGT Mullions PA-2 PGT French Doors PA-2.1 PGT Slider PA-3 Garage Door PA-4 PolyGlass TU Plus PA-4.1 PolyGlass TU Plus Installation Specs PA-5 Roof Covering S-1 Foundation Plan S-2 Floor Framing Plan S-3 House Section S-4 Structural Details S-5 Structural Details 2 S-6 Truss Connector Project Information & Design Criteria Building Code: FBC 2020 7th Edition w/All Amendenments Project Name: Project Address: Type of Construction: CBS Frame Building Designed: Enclosed Open Partially Enclosed Wind Speed (3 Sec. Gust): 160 M.P.H. 170 M.P.H. Exposure: B Internal Pressure Coefficient: +/- 0.18 Importance Factor: 1.0 Mean Building Height: <20 ft. Exposure Coefficient: Overhang 2’ 0” ft. Roof Pitch: 5.5/12 Components & Cladding Wind Pressure: Roof Dead Load: Shingles Tile Metal Framed Floor Live Load NA P.S.F. Dead Load NA P.S.F. Shutters: Yes No Impact Resistant Assembly: Yes No Design Pressure Garage Door: +26.4 -29.4 (18') +27.6 -31.2 (9') All Other Openings: +31.2 -41.0 PEREIRA RESIDENCE DRIVING DIRECTIONS (REFER TO MAP BELOW): ENTRANCE TO NOBLE OAKS ESTATES ACROSS FROM GREY TWIG JUST SOUTH OF MIDWAY ROAD AND ST. JAMES/25TH STREET OPENING PROTECTION ALL NEW OPENINGS ARE MIAMI DADE IMPACT RATED, PLEASE REFER TO DRAWING LIST (BELOW RIGHT) FOR THE SPECIFIC SHEET NUMBER RELATED TO ALL PRODUCTS USED.