HomeMy WebLinkAboutA1ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C._________________________________ ___________________________________CLIENT'S APPROVAL DATE CLIENT'S APPROVAL DATE1/13/2021 10:52:14 AM
A-1xxxx Noble Oaks LanePort Saint Lucie, FL 34981Al & Maria PereiraDrawing List
Sheet
Number Sheet Name
A-1 Cover Sheet, General Notes, Project Info & Location Map
A-2 Notes
A-3 Floor Plan
A-4 Elevations
A-5 Elevations 2
A-6 Details & Schedules
A-7 RCP
C-1 Site Plan
E-1 Electrical Plan
E-2 Electrical Notes, Legend, Riser & Calcs
M-1 Insulation & Duct Layout
P-1 Plumbing Layout
PA-1 PGT Casement Window
PA-1.2 PGT Casement Window
PA-1.3 PGT Picture Window
PA-1.4 PGT Mullions
PA-2 PGT French Doors
PA-2.1 PGT Slider
PA-3 Garage Door
PA-4 PolyGlass TU Plus
PA-4.1 PolyGlass TU Plus Installation Specs
PA-5 Roof Covering
S-1 Foundation Plan
S-2 Floor Framing Plan
S-3 House Section
S-4 Structural Details
S-5 Structural Details 2
S-6 Truss Connector
Project Information & Design Criteria
Building Code: FBC 2020 7th Edition w/All Amendenments
Project Name: Project Address:
Type of Construction: CBS Frame
Building Designed: Enclosed Open Partially Enclosed
Wind Speed (3 Sec. Gust): 160 M.P.H. 170 M.P.H.
Exposure: B
Internal Pressure Coefficient: +/- 0.18
Importance Factor: 1.0
Mean Building Height: <20 ft. Exposure Coefficient:
Overhang 2’ 0” ft. Roof Pitch: 5.5/12
Components & Cladding Wind Pressure:
Roof Dead Load: Shingles Tile Metal
Framed Floor Live Load NA P.S.F. Dead Load NA P.S.F.
Shutters: Yes No
Impact Resistant Assembly: Yes No
Design Pressure Garage Door: +26.4 -29.4 (18') +27.6 -31.2 (9')
All Other Openings: +31.2 -41.0
PEREIRA RESIDENCE
DRIVING DIRECTIONS (REFER TO MAP BELOW):
ENTRANCE TO NOBLE OAKS ESTATES
ACROSS FROM GREY TWIG JUST SOUTH OF
MIDWAY ROAD AND ST. JAMES/25TH STREET
OPENING PROTECTION
ALL NEW OPENINGS ARE MIAMI DADE
IMPACT RATED, PLEASE REFER TO
DRAWING LIST (BELOW RIGHT) FOR THE
SPECIFIC SHEET NUMBER RELATED TO ALL
PRODUCTS USED.