HomeMy WebLinkAboutE2GFCI GFCIGFCIGFCIGFCIGFCIGFCI4GFCI4334GFCIGFCI44DGFCIWPUNDER CABINET LIGHTSUNDER CABINET LIGHTSDISPOSAL120V HOOD VENTVTROVER CABINET LIGHTSHALLWAY LIGHTS240V RANGEAFCI/GFCI OUTLET FOR DISWASHER UNDER SINKUNDERGROUDUTILITIES CONNECTIONBY OTHERSF.P.L. WILL DETERMINE IFOVERHEAD ORUNDERGROUND SERVICE#2 COPPER GROUND WIRE TO FOOTER STEELAND COPPER WATER PIPEBRANCH OFF CIRCUITS AS REQUIREDP.V.C. NIPPLE WITH(2) 350 MCM CU(1) #2 CUMETERBOXHEATER/A.C. DISC.AS PER EQUIPMENTDEMAND120/240V1 sqft.-3W300 AMP40 CIRC.WITH MAINBREAKERALL GROUNDING RODS TO BE MIN. 3/4" X 10' COPPER MIN. QTY. 3~ RECEPTICALS IN BATH ARE ARE TO BE 46" A.F.F.~ PROVIDE ARC FAULT PROTECTION IN ALL LIVING SPACES PER NEC 210.8~ T.V. & PHONE JACK PRECISE LOCATIONS T.B.D. BY CONTRACTOR~ ALL MOTORS/PUMPS TO BE INSTALLED ON VIBRATION DAMPENERS & AFCI PER NEC~ ALL WP OUTLETS TO BE GFCI PER NEC 210.8~ DISHWASHER RECEPTICAL TO BE AFCI/GFCI PER NEC 210.8~ ALL RECEPTICALS WITHIN 6 FEET OF A WET AREA MUST BE AFCI/GFCI~ ALL RECEPTICALS ARE TO BE TAMPER PROOF~ BATHROOM LIGHT FIXTURES TBD BY CONTRACTOR ON SITE~ RECESSED LAMPS TO BE L.E.D. & MINIMUM 1000 LUMENSELECTRICAL LEGENDSWITCH3 WAY SWITCH4 WAY SWITCHDIMMER SWITCHWALL SCONCEDUPLEX RECEPTICALSWITCHED RECEPTICAL220V RECEPTICALRECESSED VAPOR PROOF L.E.D. LIGHTSMOKE & CARBON MONOXIDE DETECTORPUSH BUTTON (1) CAT 6EXHAUST FAN (LESS THAN 2.0 SONES)RECESSED L.E.D. CAN LIGHTPHONE & CABLE OUTLET (1)RG-6 & (1)CAT 6 SURFACE MOUNTED LIGHTCEILING FAN PRE-WIREWALL MOUNTED LIGHT L.E.D. FIXTURE1' x 4' ENCLOSED L.E.D. LIGHTL.E.D. FLOOD LIGHTSDOOR CHIMETHERMOSTATVPTD43SDFBQUAD. RECEPTICALSINGLE RECEPTICALWEATHER PROOF GFCI RECEPTICALGROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNELSHALL BE PROVIDED AS REQUIRED IN 210.8(A) THROUGH (F). THEGROUND-FAULT CIRCUIT INTERRUPTER SHALL BE INSTALLED IN A READILYACCESSIBLE LOCATION.ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES INSTALLED IN THELOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS ORLESS TO GROUND SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTERPROTECTION FOR PERSONNEL.ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY THREE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS, INSTALLED IN THE LOCATIONSSPECIFIED IN 210.8(B)(1) THROUGH (B)(12).SURGE PROTECTION TO THE SERVICE IS MANDATYORY PER NEC 230.67TYPE 1 OR TYPE 2 SPD IS ACCEPTABLEELECTRICAL NOTES:ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C._________________________________ ___________________________________CLIENT'S APPROVAL DATE CLIENT'S APPROVAL DATEAs indicated4/30/2021 10:27:29 AME-2xxxx Noble Oaks LanePort Saint Lucie, FL 34981Al & Maria Pereira1/2" = 1'-0"1First Floor-Electrical Lighting - Kitchen1/4" = 1'-0"2Electrical Riser N.T.S. 300A1/4" = 1'-0"Electrical Legend & Notes