Loading...
HomeMy WebLinkAboutS55/8 X 6 1/2 TITEN HD M.GAL - 6" FROM ENDS & 24" O.C. TIE DOWNS / HANGERS PER TRUSS LAYOUT 2X10 PT TIE BEAM (4) #51' - 0"2"2"MIN 1 1/2" CMU First Floor 0" Entry 18' -11" F3 2' - 0"11' - 7"7' - 8"4'0" 8F8-0B/0T PRE STRESSED LINTEL W/(1) #5 3000# PUMP MIX 8 X 12 FORMED TIE BEAM WITH (4) #5 CONT.1' - 0"First Floor 0" Rear Porch 15' -1" F2 3' - 0"12' - 5"2' - 0"FORMED & POURED BEAM W/(2)#5 TOP, (2) #5 MID, (2)#5 BTM & WIRE TIES/ STIRRUPS 12" O.C. 3000# PUMP MIX CEMENT MIN. 5/8" TWO COAT DECORATIVE STUCCO FINISH 2" X 8" HEMP FIR FASCIA, 1" X 2" PT UNDER DRIP EDGE W/FLAT STUCCO SOFFITS OVER HIGH RIB LATH METAL ROOF (APPLY PER PRODUCT APPROVAL PAGES OVER 19/32" CDX PLYWOOD, ON PRE-ENG. TRUSSES AT 24"c.c. 1/2" DRYWALL 8" X 12" POURED CONCRETE TIE BEAM WITH (4) #5 CONT., LAP 48 DIA. MIN. OR AS NOTED ON FLOOR PLAN 8" X 16" CONC. BLOCK WITH #5 VERT. DOWEL IN CONC. FILLED CELLS AS PER PLAN 1" X 2" P.T. FURRING ON 3/4" R5 RIGID INSULATION 1/2" DRYWALL 10'0" FROM FINISHED FLOORREFER TO ELEVATIONS 4" SLAB 3000# FIBERMESH CLEAN COMPACTED FILL4"SEE PAGE S-6 S P R A Y E D O P E N C E L L F O A M5 1/2 12 REFER TO FOOTER LEGEND REFER TO ROOFING NOTES FOR TYPICAL WALL SECTION WIRE LATH WITH DECORATIVE STUCCO FINISH 8" X 16" CONC. BLOCK OR OTHER AS SPECIFIED TRUSS BEARING POURED CONCRETE BEAM REFER TO TRUSS PLAN A.H.U . PRO ENG. TRUSSES SEE SHOP DRAWINGS FOR EXACT LOCATION OF OPTIONAL COFFER TREADED ROD SUPPORT FOR A.H.U. FROM PRO. ENG. TRUSS ABOVE FASTEN WITH 1/2" WASHER & NUT A.H.U. ABOVE DRAIN PAN CEILING GYM. WALL BOARD (2) MSTA18 (14) 10d NAILS SPHx AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE (2) 2 x STUDS 2 x PT. PLATE (2) 2 x TOP PLATE FINISHED FLOOR 5/8" x 6" EXPANDABLE REDHEAD BOLTS WITH 1/8" x 2" HOT DIPPED GALV. WASHER AT 32" o.c. OR WEDGE ANCHORS FRAMING LUMBER TO BE MIN. 2 x 4 OR AS PER PLAN EXTERIOR FINISH TO BE STUCCO OVER PAPER BACKED RIB LATH (2) 2 x 12 HEADER BOND TOGETHER WITH 16d AT 6" o.c. STAGGERED ATTACH TRUSSES TO TOP PLATE AS PER CONNECTOR SCHDLE FOR EXTERIOR WALL APPLICATION PROVIDE 1/2" C.D.X PLYWOOD ON OUTSIDE FACE OF STUDS, FASTEN PER STRUCTURAL NOTES BTM. OF FTNG. SPHx 16" o.c. 2" X (x)" P.T. STUD ATTACHED TO 8" C.M.U. WITH 1/4"X3 1/4" TAPCON AT 24" o.c. 8" C.M.U. WALL CONCRETE FILLED CELL 5/8" X 6" EXPANEDED REDHED BOLTS WITH 1/8" X 2" WASHER AT 32" o.c. 2" X 4" P.T. PLATE 2" X (x)" STUDS 16" o.c. TOP PLATE (2) 2" X (x)" SPH4 AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE FOR AN EXTERIOR WALL APPLICATION PRIVIDE 1/2" C.D.X. PLYWOOD ON OUTSIDE FACE OF STUDS & FASTEN AS PER STRUCTURAL NOTES 2"X (x)" P.T. PLATE FASTENED TO TIE BEAM WITH (3) 5/8" X 6" EXPANEDED REDHEAD BOLTS WITH 1/8" X 2" WASHER AT 32" o.c. OR 1/2" WEDGE ANCHORS 2" X (x)" STUDS 24" o.c. TOP PLATE (2) 2"X (x)" SPX AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE 2" X STUDS 16" o.c. TOP PLATE(2) 2"X SPX AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE KNEE WALL LUMBER SIZE NEEDS TO BE EQUAL TO WALL SIZE AS NOTED ON TRUSS LAYOUT OR AS SPECIFIED (2) 2 X PLATE SPX AT EVERY STUD WITH (6) 10d NAILS LSTA 24 AT 16"c.c FILL HOLES WITH 10d NAILS 1 x PT WOOD BUCK 1/4" ELCO TAPCON REQUIRED MIN. 1 1/4" CONC. EMBED. TYPICAL HEAD ANCHORAGE USING A 1x PT WOOD BUCK 1 x PT WOOD BUCK TYPICAL JAMB ANCHORAGE USING A 1x PT WOOD BUCK 1/4" ELCO TAPCON REQUIRED MIN. 1 1/4" CONC. EMBED. 2 x PT WOOD BUCK TYPICAL SILL ANCHORAGE USING A 2 x PT WOOD BUCK 1/4" ELCO TAPCON REQUIRED MIN. 1 1/4" CONC. EMBED. 90 DEGREE HOOKS 48 DIA OVERLAP MIN. SOLID POURED CELLS WITH (1)#5 CONTINUOUS REBAR FROM BEAM TO FOOTING FOR HORIZ. TIE BEAM STEEL REQUIREMENTS, SEE TYP. WALL SECTION First Floor 0" Foundation -1' -6" Main Roof 12' -1" Main Roof 2 13' -7" CA 2660-2 2 PW 2620-2 3 3' - 3 1/2"POURED IN PLACE BEAM 3000# PUMP MIX W/(6)#5 8"POURED IN PLACE SILL 3000# PUMP MIX W/(1)#5 TYP. First Floor 0" Main Roof 12' -1" Rear Porch 15' -1" Bedrooms Roof 10' -1"3' - 10"1' - 2"10' - 5"8 X 12 FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. 8 X 14 FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. CMU First Floor 0" Main Roof 12' -1" Rear Porch 15' -1" Bedrooms Roof 10' -1" 48" LINTEL 8U8-0B/0T CMU 8 X 12 FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. 8 X 12 FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C._________________________________ ___________________________________CLIENT'S APPROVAL DATE CLIENT'S APPROVAL DATEAs indicated 12/22/2020 11:47:21 AM S-5xxxx Noble Oaks LanePort Saint Lucie, FL 34981Al & Maria Pereira1 1/2" = 1'-0"1 Ledger & Beam Detail 1/4" = 1'-0"6 Front Entry Right Side 1/4" = 1'-0"7 Rear Raised Porch Beam 1/2" = 1'-0"15 TYPICAL WALL SECTION DETAIL STUCCO (N.T.S.) 1/2" = 1'-0"12 PORCH & ENTRY CEILING - POURED BEAM DETAIL (N.T.S.) 1 : 202 SUSPENDED AIR HANDLER DETAIL (N.T.S.) 1/2" = 1'-0"16 TYPICAL HEADER ATTACHMENT DETAIL (N.T.S.) 1 1/2" = 1'-0"10 WOOD TO MASONRY CONNECTION DETAIL (N.T.S.) 1/2" = 1'-0"8 KNEE WALL TO MASONRY DETAIL (N.T.S.) 1/2" = 1'-0"13 KNEE WALL TO STUD WALL DETAIL (N.T.S.) 3" = 1'-0"3 WINDOW HEAD 3" = 1'-0"4 WINDOW JAMB 3" = 1'-0"5 WINDOW SILL1 1" = 30'-0"11 CHANGE IN BEAM ELEVATION DETAIL (N.T.S.) 1/2" = 1'-0"17 Office Beam 3/8" = 1'-0"14 Rear Porch Ceiling Height Change 3/8" = 1'-0"9 Rear Porch Small Opening