Loading...
HomeMy WebLinkAboutShoreline Const. Corp. - 9102362r- MAR 11 191 14:47 FROM NOBILITY HOMES INC a�ply�-6� P AGE . 00 1 �_- STATE OF FLORIDA. DEPARTMENT OF COMMUNITY AFFAIRS 2 7.4 0 C E N T E R V I E W DRIVE • T A L L A H A S S E E, FLORIDA 3 2 3 9 9 008 MARTINEZ November 7. 1990 THOMAS G. PELHAM Cgvwrw Secretary Mr. Michael Jones Nobility Homes 3741 SW 7 Street Ocala, FL 32678 Re: Add -A --Room Approval based on the 88-SC's with 1989 Revisions Mfgs. I.D. No.: NH-179-AAR This Approval Expires December 31, 1991 Dear Mr. Jones: I am pleased to inform you that the Department of Community Affairs has granted Nobility Homes approval to manufacture Add -A -- Rooms for installation throughout the State of Florida except the Florida Keys. This extension is granted pursuant to inspection of your submitted plans which were found by this department and your inspection/plans review agency to in compliance with the applicable codes. Provisions for resistance to uplift and overturning are approved so long a the Add -A -Room is tied down on an adequate foundation, in accordance with the approved plans and specifications. A copy of this letter must -be attached to the approved plans when making application for local building permits. Sincerely, rhK. Hook Codes & Standards Section Administrator RKH/ljf cc: HWC ; EMERGENCY MANAGEMENT • HOUSING AND COMMUNITY DEVELOPMENT • RESOURCE PLANNING AND MANAGEMENT ** TOTAL PAGE.001 * F— 'ON TO TYE REplLl.RF-11ENTS OF THIS PFe�Na . THE i!_RE @1!i/-l?l RE �DOITIONAL RESTRICTIONS dal APPLICX- ' E TO THIS PROPERTY TI-IM MAY BE Fi UW-D IN THE PUBLIC RECORDS OF: ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY DATE s - �' • �.1 PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE NOTICE S NOT TO BE OCCUPIED � BEFORE FINAL APPROVAL . QUJdl_MR OBEPARTMENT L.E ATTACHED CONDITIONS 1\ /i]O61/e Hanle, . i-,aph-,s. FOR OFFICE USE ONLY SPECIAL APPROVALS REQUIRED DATE RECEIVED VEGETATION ENVIRONMENTAL PLANNING/SITE PLAN CODE ENFORCEMENT USA TAZ WATER SUPPLIER SEWER SUPPLIER DER CERTIFICATION FL DNR (CCCL) FL DOT SLC DRIVEWAY PER SLC STORMWATER PER MANGROVE ALT SEA TURTLE PROT ea« 9/-0993 NOT REQUIRED polo REQUIRED FEES $ 31l� , BP VALUE •e PLANS EXAMINING FEE $N A RADON FEE: ROAD IMPACT FEE $ N 1A. ROAD IMPACT DISTRICT ROAD IMPACT ZONE ROAD IMPACT CREDIT: -YES: NO: SCHOOL IMPACT FEE $ A/�jQ DATE PAID: SCHOOL IMPACT CREDIT: YES: NO: SCHOOL BOARD APPROVED EXEMPTION: YES: NO: ALTERNATIVE DEV. FEE $ DATE PAID: ALT. DEV. FEE ZONE: GAS AIR CONDITIONING ELECTRIC PLUMBING SCREEN ENCL/FENCE ROOF SUB PERMITS REQUIRED ZONING CHECKS NOT REQUIRED CHK# CHK# /`t LOT COVERAGE _k1A EASEMENT SPLITS A r.D0571 A ttaa� tt� "I P 1D' 10' DRMC)UT 0(o 14' 10" Co"x l(o~ x 21' 0" 'Z(o10~ FI5EQGL0.1v15 t j DUCT EOAP_) I I OPTIONAL, HVAC FLAN_ (OVEIZIAL-AD DUCT'S /2.,1Z. l AM J J st (I� 1/2" x IL4"X 24D PLti'WD lZIQ'�E BE/aN1 (">> Tr x I Go"x I(n0" PLYWD RIDGE 6EAM ID' (a" `O" 1' O" 3Co"xl8" C�FJ111NL� I I'C0" x 0110"CPFNINU (MAX.) OPT, ACKpLrZ OPT. ^ `� 11 ~= FAAV-� 10'Al>Z51� LY —11I N(Gu 1.1at�s W� FcN_� �' - txzOPOUT c " 141 10" co"TO pC- CILT+� 1 AT I L`( ' OWP 2 e'j " ao~ f+ - �.IoE] (o•`c10-D Room � -De J of _ 592' x 12"x 2D `0* '27'0" �2 Q V METAL DLIGT W I Z-45 In I OVER DUGT 2 (1)24 M'.W -�" (4) 24tS3 5N 1(0 ` 4' D' FLOOR, P LAM. E L-__CTF-1 CAL t H\/ AC, P LAIN 7I-k15 FL00F_ PLAN MAY 5E 5UILT IN A 1=L%7VEV CONVztGUPATION._ I) IZEFETL TO SYSTEM F'KG FOE TYPICAL C0N1bTR.UCT10111 DETAILS t. CR05S SECT 1 OIV . 2') FEEDER WIeE`S IN AUNICT1DN F301LTO Ie FIEM INSTALLED TO POWEIZ 50URLE FROM EXI5TINL-i APPROVED 5TMC'TU OIZ SEDEIIATR INDIV I DUAL C"12RCI=. AAID 11co 511133SL7 TO LOCAU CODE APPROVAL. FASTENER SCHEDULE TYPE I SIZE IF THE ADD -A -ROOM MODULAR DOES NOT HAVEA. SWINGING SIDE HINGE TYPE DOOR, THEN THE MAIN EGRESS DOOR MUST BE A SIDE SWINGING TYPE DOOR AND LOCATED IN EXISTING DWELLING. THE MEANS OF EGRESS TO ROUTE FROM THE ADD -ON ROOM TO THE MAIN EGRESS DOOR MUST BE IN ACCORDANCE WITH THE LIMITATIONS AND REQUIRRMM OF CHAPTER 11 OF THE STANDARD BUILDING CODE AND IS SUBJECT TO LOCAL JURISDICTION APPROVAL. ENERGY CODE COMPLIANCE SHALL BE BASED ON THE ENTIRE BUILDING, INCLUDING ADDITION, IN ACCORDANCE WITH SECTION 901.1(h) OF THE FLORIDA'ENERGY EFFICIANCY CODE FOR BUILDING CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE OWNER TO DEMONSTRATE TO THE BUILDING DEPT . ENERGY COMPLIANCE. ALL DESIGN AND CONSTRUCTION OF ATTACHMENT TO THE EXISTING STRUCTURE IS BY OTHERS, ON SITE, SUBJECT TO LOCAL APPROVAL. STN15 St DE OF UNIT TO 13E. CONNECTED 10 EX15T1NCG (�SING.LE FAMILY DWELLIM--t . T� ? __K "51B99EA1Z1+JALL ' S' PLYW000, 1Za.TED SNEATNINU FASTEM20 �WITH Sd NAIL'.) '540.C. I EDGE`).12"O.C. FIELA. P ( 4' MIN. LENGTW EACU END WALL ') -i=a✓�E 6cn-1 sIoC3 eF --SiI�AL• k/ALL lJ 1Ti; PLYl.i000. LEGEND NUMBER/SPACING t- . .TYPE I SIZE Date ...... -z-14-91 --------------- Plan No. -_-477 =9.it Appeyed By CLAYTON E. BARROWS A [ B F C G D H Modular Building Plans Examiner Florida Certificate No. 017 WINDOW 5r_'lAMUL.P_ 24 x 5's SN . --7 .2 4 GLAZE - '� ;IM V EJUT E LECTQICAL SCIEDULE NM-CU C1KT DC=5K_V.IPTION bVEAKM WIP-51M I GEA1. L1G Ii1A1(a 15 AMP 14 - 2 2 GEM-1-1614TIN6, 15AMP IA-2 SY 1'150 L4.7 -Q-WAU,M WT FIXTURE, Ga 3UNLTIDAI I5Ox :Q:DUPLFX IZECEPT $ SW ITC.1.1 ADD -A - IZOO M I APPROVAL I LISTING AGENCY 'APPROVAL These prints comply witFi the Florida Manufactured Building Act of 1979 Construction Code; and adhere to the following criteria: Const. Type V_ Occupancy Allowable No, .of Floors Wind Velocity 11— 0 .� Fire Rating of Ext. Walls 0 Plan No. 7 - k- Allow. Floor Load Approval Date Manuf. Mo13I0-f • H112-14-91 6APP DATE 5 REVISIONS DRAWN BY: DATE: 11--13-�10 SCALE: 3i1�"_ t•p,. DESCRIPTION l 4 _-71 FLOOR PtAM a ELEC. L 41VAC HWC 162T 991.11111 MYRTLE AVENUE. CLEARWATER. FLORIDA.34616 ld��] NOBILITY HOMES• INC-. OCALA,FLORIDA MODEL -LENGTH -WIDTH PRINT NUMBER FP -ID It -.s ['T 1 NDTE' ZEFE]Z. TO FLOCNZ PLAN FOR.. ACTU4,L L.ENGTN OF UN IT. B" x I V Y Ito" FT(mCON. (TLETE \ FTC Y.P.� � 13' O" MAX. TY P. 'I" 5EAM I I L IL 5'0" MAX. TYP, 8" X a" X I Io" CONGZETE MA5DNAV-Y UNIT LTYP.) 1' O a APPROVAL NOTES : I , FOUNDATION PLAN I5 SUOW M AS A lYP ICAI. STANDARD FOiZ I iFPROV �O • 7-EFEQENC.E ONLY. FOLINDATIOM PLAN INDICATES MINIMUM PIER lZF�2U11ZEMENrh TO RESIST GPAYIZI( LOADS. ACTUAL FOUNMTION CDNSTIZLIC7-I0AJ AND INhTALLATION IS 5U B3 U TO LOCAL CDDE5 AND INSPECTION. OCT 1590 6 0 2 co '�,��.� • : t c _. Q.MIN(MUM 501L 13EAIZIN6 CAPACITY - 2500 PSF. 3. MIN IMUM CONCIZETE CDMPeE55T2EN2 51UE GTW - 500 .P51 AT 70 DAY'5. 4. A� A PIEIz Ehc-H sites oF At,L ExT�p-toK AP pF�NtNC�S 1N EXCts5S of �j'-p�: MATlN&- LINE WAf1. NOTES '. E) FASTENER SCHEDULE LEGEND NUMBER/SPACING 41 9 J 3 8 TYPE SIZE TYPE SIZE 2 7 1 6 A E N APP DATE 5 REVISIONS N0131LITY HOMES, INC. B F DRAWN BY: PALMOZ OCALA.FLORIDA DATE: 9 - 12-90 MODEL -LENGTH -WIDTH SCALE: Im" C G DESCRIPTION PRINT NUMBER D H TYPICAL FOUNDATION F D - {. AP AF30371A r' ATTIC. NET VENTILATION IZIALIIIZEMEW OF I/I'oOTIA OF ROOF AR@A 15ACC.OMPL1514F-D 53Y VENTILATED 50FF1T AT OVEMHANCalb _ APPROVED TRUSS AT 1(c" O.C. DIVMC.TLY OVER WALL gTUDS OR TOP PLATE MUST PEE DOUPBLED. 12 F113E7-L-3LA`-0b OV-A` f"ALT SNINC-,LEE ON (2) LAYEQS�— OF 1'S' Ib. FELT CX4 -7/I1o" ORIENTED STRAND PXIARD, �-- --T — /A.RA.RATED SHPATMINCa, EXIMURE I, 7-4 to. ALUM. 50FFIT ALUMINUM DQIP C;OGE OPTIONAL OVE>Z{iEAD CONT. CTYP.1 - NEAT .DUC-T I X4 C)muDI•e PAIL C.ONT. I114' ,c •TOGA. GAW.9TEEL 5T1ZAP Ko"O.C. W ITIIIN (o'O' OF &ACH ENDWALL.'02.04.ELSEW41EIZE fZ-I'I CEILING INSULATION (TIP) INTERIOIL WALL W / 7 -1(o GA. x-/hv' a 1" STAPLES FIN 1&J1.1 TO 51e EACH END CFWRAP CI-PEN4TMION) 'We)" MIN. GYPSUM C61UN(a f-)OIAIZD OF CIA'-%S "C' ALL WINDOWfo SIZE TO \ 2X4 TOP PLATE CONT. TYP, S-P-F 0'15 OR E56TTM MEET REQUIRED GLAZE�� AREA AND VENT. SEE APPROVED STRUCTURAL FACV,0&q (AND EG(ZEI!�05 Ato IZEn'D.7 Fore- HEADER 7-r--Q 11ILEMENTS . 40" Y •'N4" PUTTY TAPE 02 I C SOU N . AMUND ALL WINDOW O2 I OR DOOR PEN ETQAT IOt15 010, EYTEIZIOIL 510IN6 (TYP.) 1 11 CANT. 15ELT RAIL LOPT,)— ELECTQICAL DADO Vu ITA WIRE PROTECTOR, 2X 4 BOTTOM PLATE CONT, 15-P-F *,a) OR BETTEX �J Z X4 WINDOW 15ILL , S-P-1741 b OR 13ETTE'R / 2X4 5-P-FA")5 C2IPPLE STUDS ilo'O.C.. LTYP.) Q-II FLOOR INSULATION TYPICAL I T X .0 W GALV. STEEL UPLIFT i STRAPS W/ULTIMATE LOAD CAPACITY OF 4725 lb'3. 5,0" O.G. MAX. (TYP.) (SEE NOTE 3) 10" DIA. X 15"DEEP CONC2ETE COLLAV-- v - STEEL ANCHOR TO 15E. CERTIFIED AND TEST&D Ot. jra TO W ITI45TAND W _cc LI3 UPUFT M.IN..- PUTTY TAPS. FOAM TAPD . CALILFUNCa OV- EOLUIV. CONT. 56AL AROUND ENTI2E LENG,TN AND WIDTH OF UNIT MTWEEN IbO %TOM PLATE AND FI.DnZ - TOP PLATE AND CE I L)1U 6 eOAeD AND 'DI IW WALLS TO ENOWAL.LS- FLOOR. COV EPJNL-s TOP CAfZDUT OIL ROLLOA0005 i91112" PLYWOOD FLOM 0ECKINCa,5TURD-I-FLMV-. EXP I.2O"O.C. ::- 2 X 8 x llv PT. 1e" MIN. ":WMAX.! BILL PLATE TYP. , ... L`• • AT (04•" O.C. MAX. ! if %A. Ci�UI� b .•: ,�..,�, 1�OTTOH 12"MIN. :ti•��.e:�: 8"Y ICa-xIto" C-CMCa.FTG. (TYP-1 TO %G- P..EINFOIZCED PER LOCAL CO0fe.2GOUIMMENT AND MUST' I3E P.�ELOW FPOST LINE V0TE5:I),o,LI-- DESIC-*k1 AND cohesTQUGT1bm OF ATTACHM6NIT TO THrE EXI`STINCa STTtUGTUP$ 1'b PSY CTIIIEQ.S A4D Id6 gUF53re. CT TO LOCAL. COOE`7 AND oWizOVAT 2) DELETED '5)714E FIIZ5T FOUNDATIOAI TIE -DOWN STRAP FIZOM ENDWALLS 514ALL NOT EXCEED I/2 THE MAXIMUM SPACIN(a INDICATEE7, �I 41 UNLLQbd5 OTREfLW 15Q SPECIFIED) ALL STEEL MUST COMPLY W IT14 ASTM A'1(0, YEI LO 9TIZENGTt 1 - - C K5l . 5)ALL LAG a�CIZP-W5 MUST COMPLY WIT14 ASTM A 30-7. FASTENER SCHEDULE TYPE I SIZE ---�2X'fo 3015T 1(c"O.C. TYP, S-P-F-a rz R-DUGT6C:OL.LAM ----- OUTZI Gr-39fL5 Co4" O,G. MAX. TYP. MAIN I -BEAM (TYP.) P.T.SNIM FOM LEVELING \15"x8"YI(o" C-ONIC.MA50KIA1ZY UNIT TYP. ..�,. (Q) "�/0" x'b'12" LAG 5C2EW5 LAC-,E TIAVOL1614 FN a_: INTO 2015T AT EACH OUTZIGIhSM. 1=ASTFJII 21nGG FSC�M TO EL>vGN TlZU55 W 1TH 'S-1-SCaA. �/lV" CRGWN `STAPLES. / 1" PENETRATION INTO KING POST OR ECIUIVAL UT FASTENING+. ALUMINUM 'DR1P EDGE CONT. CTYPJ PLYWOOD RIDGE FSFIAM-5EE APPEMP-D STIZUCTU2AU i, PACKACaIG FOR ALL.DWAI3LE %P"Aa . 2 , I'I2s X ")O GA.GALV.'3TEEL cbTQAP I(a" O.C. WITHIN Co`O"OF E�G>1 ENDWALI.,'�'2"O.C. ELStiWNEPE WIT 4 1 - 1(oC�A x /llo"�c I" STAPLES 1EAL.N END OF STRAY C 1" PENETRATION RTcQU\QEp.;1 'Z>C4 TOP PLATE CONT. 1`5 OR LITER. EXTERIOTL 71NISH TO 115E VEQ.TICAC_ METAL, ALUM. LAP OIL VINYL LAP gbIDINC-n WHEN EXPO5ED TO OUTSIDE OR PANEUN(a WHEN CONVECTED TO AN EXI`3TIN6 ST(LUCTUIZS. EXTEIZIOM WALL CbIISATHIAIL-A TO bE %/I31( RED) i 5TIZUCTURAL THERMAL PLY Or- -/13" MIN. ! EXPOSUQQ I PLYWOOD% IZATEO SASATRING Uh6 SLAMS 13PACING ON MATINCa WALL C 44 )AIM. LP-MaTVA AT EACV1 CO(mo?-) M- 1.1 WALL. INSULATION CTYP.I 2X4 g-P-F il 2 5TUD'5 ICo" O.C. CTYPI. 2 X4 PSOTTOM PLATE CONT. 5-P-F3►3 OIZ F3ETTEIL. � P LEGEND NUMBER/SPACING TYPE SIZE A E B F C G D H 21 171 NOJ APP DATE 151 DRAWN BY: PALMFIL DATE: c� - I 1-010 SCALE: 112° - I, o" DESCRIPTION TYPICAL CR055 SECTIOM' i. l NOBILITY HOMES, INC. OCALA,FLORIDA MODEL -LENGTH -WIDTH PRINT NUMBER C S -I i' .�c (3- o